Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Sliding friction and wear behavior of nuclear graphite in high temperature inert environment: Influence of contact load, speed and temperature

Repeated dynamic interactions of graphitic components in pebble-bed gas-cooled nuclear reactors can cause abrasive wear-induced pebble surface damage, generate hazardous fine graphite debris, and alter fuel circulation dynamics due to changes in friction behavior. Comprehensive tribological characterization of nuclear graphitic materials in conditions relevant to reactor operation is needed to assess reactor long-term safety and performance. This work reports sliding friction and wear behavior of self-mated nuclear graphite ET-10 at various elevated temperatures (650 °C and 750 °C), sliding speeds (1 and 10 mm/s) and contact loads (20 and 40 N) in a controlled argon environment. The results revealed nonmonotonic frictional behavior with a higher running-in coefficient of friction (COF) followed by a lower steady-state COF, as a result of transition from two-body abrasion to three-body abrasion along with formation of a tribofilm. A key finding of this work is the sensitivity of the running-in COF to experimental conditions; maximum running-in values were lower at either elevated temperature (0.52–0.54) or reduced sliding speed (0.51–0.54). Conversely, the steady-state COF remained invariant at approximately 0.3 across all tested parameters. Transmission electron microscopy revealed a 0.5–2.0 μm thick nanocrystalline tribofilm that was thought to be formed by the compaction of the graphitic wear debris on the contact surface during the sliding process. The nanocrystalline nature of the tribofilm was further confirmed by Raman spectroscopy. As a result, the combination of tribological testing and morphological characterization provided a mechanistic understanding of the frictional behavior of nuclear graphite upon sliding.

Friction↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Molecular origin of anisotropic shear elastoplasticity in chitin

Chitin nano- and mesoscale structures present in the exoskeleton of crustaceans exhibit exceptional longitudinal stiffness and toughness, rivaling or even exceeding that of many synthetic polymer architectures. Here, we reveal the origin of the asymmetric shear response in chitin multiscale architectures, marked by pronounced anisotropy in deformation. Under shear aligned with the molecular axis, chitin accommodates strain through coherent atomic rearrangements that enable elastic recovery. In contrast, shear applied perpendicular to this axis induces liquid-like plasticity via localized sliding. These results demonstrate the intrinsic mechanical anisotropy of chitin, underpinning a dual function in resisting repetitive loading while dissipating internal stress during high-strain events. Our findings establish the molecular basis of shear elastoplasticity in multiscale chitin structures, wherein axial elasticity supports energy storage in load-bearing regions, whereas transverse plasticity enables controlled energy dissipation. These atomic-scale insights lay a foundation for the predictive design of chitin-based materials with tunable strength-toughness profiles.

Wan, Zhangmin [University of British Columbia, Van↗

Scheduler Modeling of IBR Plants for Providing Ancillary Services [SWR-25-16]

Inverter-based resources (IBRs) have been integral components of modern power systems and their capability in providing grid services have been widely studied. To promote the deployment of IBR grid services in real utility operation, this software proposes a scheduler model for IBRs. The energy and reserve are co-optimized in day-ahead, various ancillary services, including operating reserve provision, peak load reduction, voltage regulation and power factor control are integrated in the model.

Wang, Xiaofei [National Renewable Energy Laborator↗

Project Report: School Retrofit Demonstration of Lighting and Outlet Controls with LED Upgrades

A technology demonstration project funded by the U.S. Department of Energy (DOE) was hosted by Boston Public Schools (BPS). This project evaluated wireless controls technology for lighting systems and plug loads (energy consumed by devices plugged into electrical outlets), implemented along with LED lighting retrofits in two classrooms. This study assesses technology readiness and effectiveness to determine the deployment potential of the technology in schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Explicit Dynamic Impact Analysis of the Building 3525 Packages

This report describes the methodology used for the safety basis analysis of the Building (Bldg.) 3525 casks and presents preliminary results for a selected geometry. The specific problem analyzed is a free fall load case onto an unyielding target at various orientations. The various orientations were analyzed to ensure that the packages were subjected to the orientation that causes the most damage. The analysis approach, material modeling, finite element modeling, and results for the selected case are presented, along with a brief discussion of conservatism and uncertainties. The results for the analyzed load cases show that through selected administrative controls, no breach of the container or loss of shielding will occur in the package.

42 ENGINEERING↗

Spectral proper orthogonal decomposition of active wake mixing dynamics in a stable atmospheric boundary layer

Recent advancements in the use of active wake mixing (AWM) to reduce wake effects on downstream turbines open new avenues for increasing power generation in wind farms. However, a better understanding of the fluid dynamics underlying AWM is still needed to make wake mixing a reliable strategy for wind farm flow control. In this work, a spectral proper orthogonal decomposition (SPOD) is used to analyze the dynamics of coherent flow structures that are induced in the wake through blade pitch actuation. The data are generated using the ExaWind software suite to perform large eddy simulations of an NREL 2.8 MW turbine operating in a stable atmospheric boundary layer. SPOD tracks the modal behavior of flow structures from their generation in the turbine induction field through their growth in the near-wake region and to their subsequent evolution and energy transfers in the far wake. SPOD is shown to be a useful tool in the context of AWM because it translates the wavenumber and frequency inputs to the turbine controller to structures in the wake. A decomposition of the radial shear stress flux in the wake is also developed using SPOD to measure the contribution of coherent flow structures to mean flow turbulent entrainment and wake recovery. The effectiveness of AWM is connected to its ability to excite inherent structures in the wake of the turbine that arise using baseline controls. The effects of AWM on blade loading are also analyzed by connecting the axial force along the blade to the SPOD analysis of the turbine induction field. Lastly, the performance of different AWM strategies is demonstrated in a two-turbine array.

17 WIND ENERGY↗

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Feedforward-feedback ammonia control at a water resource recovery facility based on a digital twin with hybrid model

Ammonia-based aeration control (ABAC) at full-scale Water Resource Recovery Facilities (WRRFs) can be challenged by diurnal loading and transport delays. This work addressed these challenges using a hybrid feedforward–feedback controller built on Activated Sludge Model 1 (ASM1), marking the first full-scale deployment to pair a mechanistic feedforward core with data-driven corrections. The objectives were to improve ammonia setpoint tracking, assess performance of the mechanistic model when enhanced with data-driven corrections, and document full-scale operation. The hybrid model incorporates two data-driven components: (1) a Mechanistic Error Forecasting Engine (MEFE), consisting of a multivariate linear regressor and a long short-term memory (LSTM) ensemble. Defying expectations, low-parameter models outperformed more complex alternatives, reducing the mechanistic error by 71%. (2) A Residual Oscillation Forecasting Engine (ROFE), based on Fast Fourier Transform, reduced the remaining error by another 35%. Two proportional–integral (PI) feedback loops further (i) trim the feedforward output and (ii) eliminate residual controller error in the final aerobic zone. In full-scale operation, the controller reduced mean-squared error (MSE) by 94% over the baseline and produced more stable dissolved oxygen (DO) setpoints. Overall, it was proven that layering multi-timescale data-driven models on a mechanistic core can yield reliable ABAC performance at WRRFs.

54 ENVIRONMENTAL SCIENCES↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

The impact of chromium coatings on Zircaloy cladding deformation behavior under reactivity-initiated accident-like mechanical loading conditions

A reactivity-initiated accident (RIA) occurs when a control rod ejection or control blade drop causes an increase in the fission rate. The injection of energy results in an increase in fuel temperature which in turn causes rapid thermal expansion of the fuel pellet. This thermal expansion may result in pellet-cladding mechanical interaction (PCMI) in which the fuel imparts a mechanical strain to the cladding. PCMI may cause the cladding to fail, and thus, the mechanical response of cladding due to PCMI must be investigated when characterizing new cladding materials. Chromium-coated Zircaloy-4 is a near-term accident-tolerant fuel cladding that exhibits improved high-temperature oxidation resistance. Modified burst testing was utilized to experimentally simulate the effects of PCMI on both uncoated and chromium-coated Zircaloy cladding samples at hot zero power conditions. Samples were coated using either cold spraying or physical vapor deposition to understand the differences in behavior that the coating application method may cause. Digital image correlation was used to analyze images of the deforming specimens to extract the in-situ strain behavior of the cladding. The uncoated specimens burst at hoop strains ranging from 8.8 % to 17.2 %. The cold-spray chromium-coated Zircaloy specimens burst at hoop strains of 7.0 % to 11.0 %. The physical vapor deposition coated tubes burst at hoop strains of 9.1 % to 11.5 %. These results indicate that the chromium coating causes a loss in the ductility of the cladding. Furthermore, the higher burst hoop strains of the physical vapor deposition-coated samples relative to the cold-spray samples indicate that the cold-spraying technique causes more of a loss in ductility than physical vapor deposition. All samples burst at higher hoop strains than those expected to occur in an RIA for fresh cladding.

Accident-tolerant fuel↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Evaluating Function-as-a-Service (FaaS) frameworks for the Accelerator Control System

As particle accelerator control systems evolve in complexity and scale, the need for responsive, scalable, and cost-effective computational infrastructure becomes increasingly critical. Function-as-a-Service (FaaS) offers an alternative to traditional monolithic architecture by enabling event-driven execution, automatic scaling, and fine-grained resource utilization. This paper explores the applicability and performance of FaaS frameworks in the context of a modern particle accelerator control system, with the objective of evaluating their suitability for short lived and triggered workloads. In this paper, we evaluate prominent open-source FaaS platforms in executing functional logic, triggers, and diagnostics routines. Evaluation metrics consist of cold-start latency, scalability, performance, integration with other open-source tools like Kafka. Experimental workloads were designed to simulate real-world control tasks when implemented as stateless FaaS functions. These workloads were benchmarked under various invocation loads and network conditions. Self-hosted FaaS platforms, when deployed within accelerator networks, offer greater control over execution environment, better integration with legacy systems, and support for real-time guarantees when paired with message queues. Based on lessons learned and evaluation metrics, this paper describes reliability of the FaaS framework for the Accelerator Control Systems (ACS).

Jaikar, A. [Fermilab] (ORCID:0000000332046217)↗