Search NASA⌕ Search

SEARCH · Search NASA

Results for “load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

A tri-level distribution locational marginal price-based demand response framework

Here, in this paper, we propose a tri-level, nested, two-stage price-based demand response (PBDR) framework that considers distribution locational marginal price (DLMP) as DR enabler between load-serving entities (LSE), demand response providers (DRPs), and customers in the day-ahead distribution market. It enables LSE and customer interactions by using multiple DRPs, positioned in-between, and independently optimizes their objectives. The problem is formulated using linear power flow with approximated power losses and its application in DLMP as DR pricing. The tri-level problem is solved using a nested reformulation & decomposition (R&D) method and tested on the real Indian-108 bus distribution system under various dynamic pricings. Further, the temporal–spatial variations in DLMPs are assessed using fairness criteria. Numerical analyses demonstrate that DLMP applications can effectively improve economic efficiency, and transparency in DR programs valuation with a favorable fairness margin. The results show that DLMP as DR pricing signal induces (0-2) % variation in DLMP for DR participation up to 10 %. Further, it gives over 90 % fairness over temporal–spatial variation for all the customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Congestion levels on existing infrastructure

Congestion occurs when available least-cost energy cannot be delivered to some loads because transmission facilities do not have sufficient capacity to deliver the energy. When a transmission constraint is binding (i.e., its limit is reached) it has an associated shadow price – the marginal value of relieving the constraint (i.e., of increasing the asset’s flow limit). This report contains one page dedicated to each ISO and RTO in the U.S. documenting empirical outcomes related to binding constraints during 2022 through 2024 for both the day-ahead and real-time markets. For each system operator and market timeline, the report contains two maps of infrastructure elements that are color-coded based on congestion characteristics. The first map provides information on how often each element has a binding constraint, that is, the frequency of congestion on the element. The second map reflects the intensity of congestion, measured as the sum of shadow prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

Synergistic Solvent-Surface Interactions Enable Alkyne Semihydrogenation at Palladium

Enabling higher yield and better selectivity for fine-chemical synthesis through heterogeneous catalysis is intricately linked to the interplay of active sites, reaction conditions, and mass transfer influence provided by the catalyst. Alkyne semihydrogenation is ubiquitous in the production of bulk chemicals in the pharmaceutical, polymer, or fine-chemical industries, but product selectivity remains a major challenge. Here, in this study, we demonstrate that the design of catalysts encompassing nickel (Ni) foams as contiguous monolith supports, decorated with ultralow loading of Pd/PdO x nanoparticles on a carbonized polydopamine interface and tuned with a thin layer of Al 2 O 3 , in conjunction with an optimized reaction environment leads to highly selective alkyne semihydrogenation. The reactions demonstrate good functional group tolerance and applicability to flow reactor systems. Combined computational and experimental studies are presented to describe the synergistic effect between the solvent-surface interaction and the degree of Pd surface reduction that are necessary to promote this selectivity. The system highlights the opportunity for catalyst-solvent codesign as a benign alternative to more complex reactants featuring extrinsic poisons or less-favored dopants.

atomic layer deposition↗

Design and Engineering of LUPIN: A Test-Bed Radio-Frequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is a radio-frequency (RF) inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D neutral beam injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa ⋅ L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Finally, results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Rules for the crystallite size and dislocation density evolution in phases during α-ω transformation in Zr under high-pressure and severe plastic flow

The first in-situ X-ray diffraction (XRD) study of the evolution of the crystallite size and dislocation density in phases during plastic strain-induced phase transformation (PT) is performed utilizing α-ω PT in strongly pre-deformed commercially pure Zr as an important example. Rough diamond anvils (rough-DA) are introduced to intensify all occurring processes during heterogeneous compression of Zr in a diamond anvil cell (DAC). The main rule is found that during α-ω PT the crystallite size and dislocation density in ω-Zr depend solely on the volume fraction of ω-Zr and are independent of pressure, plastic strain tensor, its path, and initial nanostructure. Crystallite size in ω-Zr increases from 10 to 60 nm during the PT, while dislocation density reduces from 1.83×10 15 /m 2 to 0.6×10 15 /m 2 . Rough-DA produce a steady nanostructure in α-Zr before PT with smaller crystallite size and larger dislocation density than smooth-DA, leading to a reduction of the minimum pressure for α-ω PT to a record value 0.67 GPa, 9 times smaller than under hydrostatic loading and 5.1 times lower than the phase equilibrium pressure. In addition to strain, the kinetics of strain-induced PT unexpectedly depends on time. Also, strain-controlled part of kinetics is zero order, in contrast to the first-order kinetics with smooth-DA. The obtained results open a new window for understanding the mutual effects of nanostructure evolution and PT during severe plastic flow in various technological and natural processes. In conclusion, they may bring up economic strategies of producing nanocomposites and single-phase nanostructured materials with optimal properties.

Crystalline size↗

Numerical Investigation of a Small Low-Flow Marine Hydrokinetic (MHK) Turbine for Small Autonomous Unmanned Mobile Recharge Stations (CRADA Final Report)

This project will improve the hydrodynamic performance of the undershot waterwheel turbine with a flow concentrator designed by the Participant, using a computational fluid dynamics study. The influence of different result parameters including the number of blades, turbine profile, submerged depth, tip speed ratio, concentrator geometry and wave + current conditions will be assessed to maximize power performance and minimize structural loads.

16 TIDAL AND WAVE POWER↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Retrofittable Thermal Switches for Dynamic Building Envelopes Integrated with Thermal Energy Storage: Preprint

Buildings in the United States consume about 40 quadrillion BTU of primary energy annually, which accounts for the nation's 40% of total energy use, 75% of all electricity use, and 35% of the net carbon emissions. Deploying thermal energy storage in the form of phase change material (PCM) in building envelopes is an effective method to reduce space heating/cooling loads, provide load shedding, and shift demand to periods of lower energy cost. However, the full potential of PCM-integrated envelopes can only be realized if the PCM undergoes complete phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Conventional thermal insulation (with a fixed thermal resistance) limits PCM utilization, particularly with the increasing emphasis on higher R-value in building envelopes, which negatively affects the energy-saving potential of a PCM-integrated envelope. In contrast, dynamic building envelopes integrated with PCMs provide the option of varying the thermal resistance based on the indoor and outdoor conditions, thereby enhancing utilization of free ambient cooling and heating to charge/discharge the PCM thermal storage, reducing the buildings' heating and cooling load, and shifting the peak energy demand. In this study, we demonstrate innovative retrofittable thermal switches in the form of the insertable plugs inside an insulation to provide variable thermal resistance depending on the operating temperature and direction of temperature gradient, thus allowing preferential directional heat flow. Notably, they are passive in nature, requiring no external power, and work solely based on the ambient temperature.

buildings↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Design and demonstration of a direct air capture system with moisture-driven CO 2 delivery into aqueous medium

Two direct air capture (DAC) systems were designed and demonstrated to passively capture CO 2 from ambient air and use moisture to release the CO2 into an alkaline medium. A bench-scale system delivering ∼1 g CO 2 d –1 was demonstrated in a laminar flow hood, and a small pilot-scale system that could deliver ∼100 g CO 2 d –1 was operated outdoors in a 4.2 m 2 raceway pond. Novel elongated mesh-tube packets containing anion-exchange resin (AER) beads were found to reduce drying and CO 2 loading time 4.3-fold compared to larger mesh bags. Technoeconomic analysis (TEA) estimates the cost of capturing CO 2 into an alkaline solution, suitable for cultivating photosynthetic microorganisms, to be $\$229$ per tonne for a practical scenario based on current results and $\$72$ per tonne for an aspirational scenario considering improvements to sorbent capacity, hydrophobicity, and sorbent lifetime. TEA further estimates an additional $\$110$ per tonne to extract CO 2 from solution, purify it, and compress it to 15 MPa, suitable for sequestration. Furthermore, moisture-driven processes have the potential to use up to 87% less energy than thermal and/or vacuum swing DAC by using energy from water evaporation.

09 BIOMASS FUELS↗