Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Influence of Fiber Content, Thermal Cycles and Creep on Electrical Resistivity Measurements of SiCf/SiC Minicomposites

Fiber-reinforced Ceramic Matrix Composites (CMCs) are currently being used in high-temperature applications such as jet engine components. In such extreme environment applications, materials are exposed to many mechanical and thermal loading cycles during the life of the component. This exposure can degrade the component, and thus, components need to be monitored and inspected during service. The electrical resistivity nondestructive evaluation technique has been shown to be very sensitive to damage in CMCs, and although its performance is highly dependent on temperature, this temperature-dependence is still not well understood. Therefore, this current study aims to establish the influence of thermal cycles, creep, CVI-SiC matrix cracks and fiber volume fraction on the electrical resistance of Hi Nicalon and Hi-Nicalon Type S SiC fiber-reinforced minicomposites with BN interphases. Minicomposites with 97% CVI-SiC matrix volume fraction were used to characterize the electrical resistivity of the CVI-SiC matrix. Next, models were constructed to calculate fiber resistivity and onset and evolution of damage during tensile testing at room-temperature. The thermal cycles were achieved by heating as-received and precracked specimens to 1200°C and then cooling them to room temperature, with or without applied stress on fibers.

creep↗

Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence.

Rummel, W. D.↗

Strain Measurement Using FBG on COPV in Stress Rupture Test

White Sands Test Facility (WSTF) was requested to perform ambient temperature hydrostatic pressurization testing of a Space Transportation System (STS) 40-in. Kevlar Composite Overwrapped Pressure Vessel (COPV). The 40-in. vessel was of the same design and approximate age as the STS Main Propulsion System (MPS) and Orbiter Maneuvering System (OMS) vessels. The NASA Engineering Safety Center (NESC) assembled a team of experts and conducted an assessment that involved a review of national Kevlar COPY data. During the review, the STS COPVs were found to be beyond their original certification of ten years. The team observed that the likelihood of STS COPV Stress rupture, a catastrophic burst before leak failure mode, was greater than previously believed. Consequently, a detailed assessment of remaining stress rupture life became necessary. Prior to STS-114, a certification deviation was written for two flights of OV-103 (Discovery) and OV-104 (Atlantis) per rationale that was based on an extensive review of the Lawrence Livermore National Laboratories, COPV data, and revisions to the STS COPV stress levels. In order to obtain flight rationale to extend the certification deviation through the end of the Program, the Orbiter Project Office has directed an interagency COPV team to conduct further testing and analysis to investigate conservatism in the stress rupture model and evaluate material age degradation. Additional analysis of stress rupture life requires understanding the fiber stresses including stress that occurs due to thru-wall composite compression in COPV components. Data must be obtained at both zero gauge pressure (pre-stress) and at the component operating pressure so that this phenomenon can be properly evaluated. The zero gauge pressure stresses are predominantly a result of the autofrettage process used during vessel manufacture. Determining these pre-stresses and the constitutive behavior of the overwrap at pressure will provide necessary information to better predict the remaining life of the STS COPVs. The primary test objective is obtaining data to verify the hypothesis of a radially oriented thru-thickness stress-riser in the COPV composite whose magnitude is a function of the applied pressure and the load history. The anticipated load dependent response follows from the constitutive behavior of the composite overwrap so data to quantify its nonlinear and time dependent response will be sought. The objective of the Fiber Braggs Gratings (FBGs) were to advance the state-of-the-art by developing techniques using FBG sensors that are capable of assessing stress-rupture degradation in Kevlar COPVs in a health monitoring mode (1). Moreover, they sought to answer questions of how embedded sensors affect overall integrity of the structure. And lastly, they sought to provide an important link in the overall stress rupture study that will help close the loop on the COPV fabrication process. NDE inspection methods will be used from start to finish and FBG will be an integral link within the overall chain.

Banks, Curtis↗

Investigating Additively Manufactured 17-4 PH for Structural Applications

17-4 is used regularly to manufacture force transducers particularly for wind tunnel testing. Such applications place demanding structural requirements on the transducers with static safety factors of 1.5 common and the potential for additional dynamic loads. Additive manufacturing (AM) of transducers is very appealing because of significant potential cost and time savings as well as increased design flexibility. This study looks at the processing of 17-4 powder using selective laser melting by two different facilities using their own best practices. Hot isostatic pressing (HIP) is used by both facilities as part of the thermomechanical processing following printing to explore whether it can improve the consistency of mechanical properties. Results revealed that HIP reduced average porosity of 17-4 parts and that the yield strength of parts following solutionization and aging met wrought material property targets. Strain to failure of one of the facilities parts was less than 5% compared to greater than 9% for the other facility. Inspection of failure surfaces revealed this discrepancy could be attributed to pores (2-4% area fraction) on the failure surface of the low ductility parts. Phase content varied between the facilities with one facility producing fully martensitic parts and the other containing some retained austenite. The phase content of the starting powder and a slower than air cooling rate following the final heat treatment above the austenite eutectoid temperature are likely sources of the retained austenite. Taken together these results suggest that the current state of the art in AM 17-4 processing is sufficient for many NASA force measurement applications, but that attention is required at each stage of processing to assure desired mechanical properties.

Burns, Devin E.↗

Examination, evaluation and repair of laminated wood blades after service on the Mod-OA wind turbine

Laminated wood blades were designed, fabricated, and installed on a 200-KW wind turbine (Mod-OA). The machine uses a two-blade rotor with a diameter of 38.1 m (125 ft). Each blade weights less than 1361 kg (3000 lb). After operating in the field, two blade sets were returned for inspection. One set had been in Hawaii for 17 months (7844 hr of operation) and the other had been at Block Island, Rhode Island, for 26 months (22 months operating - 7564 hr). The Hawaii set was returned because of one of the studs that holds the blade to the hub had failed. This was found to be caused by a combination of improper installation and inadequate corrosion protection. No other problems were found. The broken stud (along with four others that were badly corroded) was replaced and the blades are now in storage. The Block Island set of blades was returned at the completion of the test program, but one blade was found to have developed a crack in the leading edge along the entire span. This crack was found to be the result of a manufacturing process problem but was not structurally critical. When a load-deflection test was conducted on the cracked blade, the response was identical to that measured before installation. In general, the laminate quality of both blade sets was excellent. No significant internal delamination or structural defects were found in any blade. The stud bonding process requires close tolerance control and adequate corrosion protection, but studs can be removed and replaced without major problems. Moisture content stabilization does not appear to be a problem, and laminated wood blades are satisfactory for long-term operation on Mod-OA wind turbines.

Faddoul, J. R.↗

Nondestructive Structural Damage Detection in Flexible Space Structures Using Vibration Characterization

Spacecraft are susceptible to structural damage over their operating life from impact, environmental loads, and fatigue. Structural damage that is not detected and not corrected may potentially cause more damage and eventually catastrophic structural failure. NASA's current fleet of reusable spacecraft, namely the Space Shuttle, has been flown on several missions. In addition, configurations of future NASA space structures, e.g. Space Station Freedom, are larger and more complex than current structures, making them more susceptible to damage as well as being more difficult to inspect. Consequently, a reliable structural damage detection capability is essential to maintain the flight safety of these structures. Visual inspections alone can not locate impending material failure (fatigue cracks, yielding); it can only observe post-failure situations. An alternative approach is to develop an inspection and monitoring system based on vibration characterization that assesses the integrity of structural and mechanical components. A methodology for detecting structural damage is presented. This methodology is based on utilizing modal test data in conjunction with a correlated analytical model of the structure to: (1) identify the structural dynamic characteristics (resonant frequencies and mode shapes) from measurements of ambient motions and/or force excitation; (2) calculate modal residual force vectors to identify the location of structural damage; and (3) conduct a weighted sensitivity analysis in order to assess the extent of mass and stiffness variations, where structural damage is characterized by stiffness reductions. The approach is unique from other existing approaches in that varying system mass and stiffness, mass center locations, the perturbation of both the natural frequencies and mode shapes, and statistical confidence factors for structural parameters and experimental instrumentation are all accounted for directly.

Ricles, James M.↗

Structural analysis of an NDE-inspected carbon-carbon component

In this research, it is demonstrated that the integration of nondestructive evaluation with the finite element method (a quantitative NDE/FEM approach) can be used for analysis and behavior prediction of advanced materials, such as fiber composites, after processing and during in-service testing. First, stress, strain, and energy data were calculated by the finite element method for square plates with a 10 percent difference in the material properties between specified segments, i.e., between the center and the outside section or between two halves of the plate. This demonstrated the efficiency of the method in predicting variations in the structural behavior based on small material property differences. Then, finite element analyses and actual axial compression tests were performed on a Space Shuttle brake stator made from woven carbon-carbon composites. The material properties used in the numerical modeling of the stator were previously characterized at a large number of points on the component by quantitative NDE-procedures, i.e., ultrasonics and radiography. The results from the experimental compressive loading tests were used to verify the NDE/FEM results. Good agreement was found for most parameters.

Striz, A. G.↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Space Shuttle Main Engine - The Relentless Pursuit of Improvement

The Space Shuttle Main Engine (SSME) is the only reusable large liquid rocket engine ever developed. The specific impulse delivered by the staged combustion cycle, substantially higher than previous rocket engines, minimized volume and weight for the integrated vehicle. The dual pre-burner configuration permitted precise mixture ratio and thrust control while the fully redundant controller and avionics provided a very high degree of system reliability and health diagnosis. The main engine controller design was the first rocket engine application to incorporate digital processing. The engine was required to operate at a high chamber pressure to minimize engine volume and weight. Power level throttling was required to minimize structural loads on the vehicle early in flight and acceleration levels on the crew late in ascent. Fatigue capability, strength, ease of assembly and disassembly, inspectability, and materials compatibility were all major considerations in achieving a fully reusable design. During the multi-decade program the design evolved substantially using a series of block upgrades. A number of materials and manufacturing challenges were encountered throughout SSME s history. Significant development was required for the final configuration of the high pressure turbopumps. Fracture control was implemented to assess life limits of critical materials and components. Survival in the hydrogen environment required assessment of hydrogen embrittlement. Instrumentation systems were a challenge due to the harsh thermal and dynamic environments within the engine. Extensive inspection procedures were developed to assess the engine components between flights. The Space Shuttle Main Engine achieved a remarkable flight performance record. All flights were successful with only one mission requiring an ascent abort condition, which still resulted in an acceptable orbit and mission. This was achieved in large part via extensive ground testing to fully characterize performance and to establish acceptable life limits. During the program over a million seconds of accumulated test and flight time was achieved. Post flight inspection and assessment was a key part of assuring proper performance of the flight hardware. By the end of the program the predicted reliability had improved by a factor of four. These unique challenges, evolution of the design, and the resulting reliability will be discussed in this paper.

VanHooser, Katherine P.↗

Reliability Quantification of the Flexure: A Critical Stirling Convertor Component

Uncertainties in the manufacturing, fabrication process, material behavior, loads, and boundary conditions results in the variation of the stresses and strains induced in the flexures and its fatigue life. Past experience and the test data at material coupon levels revealed a significant amount of scatter of the fatigue life. Owing to these facts, the design of the flexure, using conventional approaches based on safety factor or traditional reliability based on similar equipment considerations does not provide a direct measure of reliability. Additionally, it may not be feasible to run actual long term fatigue tests due to cost and time constraints. Therefore it is difficult to ascertain material fatigue strength limit. The objective of the paper is to present a methodology and quantified results of numerical simulation for the reliability of flexures used in the Stirling convertor for their structural performance. The proposed approach is based on application of finite element analysis method in combination with the random fatigue limit model, which includes uncertainties in material fatigue life. Additionally, sensitivity of fatigue life reliability to the design variables is quantified and its use to develop guidelines to improve design, manufacturing, quality control and inspection design process is described.

Shah, Ashwin R.↗

Sprayable Phase Change Coating Thermal Protection Material

NASA has expressed a need for reusable, environmentally friendly, phase change coating that is capable of withstanding the heat loads that have historically required an ablative thermal insulation. The Space Shuttle Program currently relies on ablative materials for thermal protection. The problem with an ablative insulation is that, by design, the material ablates away, in fulfilling its function of cooling the underlying substrate, thus preventing the insulation from being reused from flight to flight. The present generation of environmentally friendly, sprayable, ablative thermal insulation (MCC-l); currently use on the Space Shuttle SRBs, is very close to being a reusable insulation system. In actual flight conditions, as confirmed by the post-flight inspections of the SRBs, very little of the material ablates. Multi-flight thermal insulation use has not been qualified for the Space Shuttle. The gap that would have to be overcome in order to implement a reusable Phase Change Coating (PCC) is not unmanageable. PCC could be applied robotically with a spray process utilizing phase change material as filler to yield material of even higher strength and reliability as compared to MCC-1. The PCC filled coatings have also demonstrated potential as cryogenic thermal coatings. In experimental thermal tests, a thin application of PCC has provided the same thermal protection as a much thicker and heavier application of a traditional ablative thermal insulation. In addition, tests have shown that the structural integrity of the coating has been maintained and phase change performance after several aero-thermal cycles was not affected. Experimental tests have also shown that, unlike traditional ablative thermal insulations, PCC would not require an environmental seal coat, which has historically been required to prevent moisture absorption by the thermal insulation, prevent environmental degradation, and to improve the optical and aerodynamic properties. In order to reduce the launch and processing costs of a reusable space vehicle to an affordable level, refurbishment costs must be substantially reduced. A key component of such a cost effective approach is the use of a reusable, phase change, thermal protection coating.

Richardson, Rod W.↗

Qualification Motor no. 8 (QM-8), volume 1

All inspection and instrumentation data indicate that the QM-8 static test firing conducted 20 January 1989 was successful. Ambient temperature at T-0 was 28 F. With two flights successfully accomplished, this final test in the redesigned solid rocket motor (RSRM) program certified that the design meets motor performance requirements under extreme cold conditions. This test was a prerequisite to the third flight. The entire test article was cold conditioned at 20 to 25 F for approximately 31 days to assure a maximum propellant mean bulk temperature (PMBT) of 40 F, making it the lowest PMBT in the history of the program. This extreme condition also presented the opportunity to certify critical components at low temperatures. Certification of field joint and igniter heaters, adhesive bondline integrity, flex bearing performance, flight instrumentation performance, RSRM seal performance, and LSC and nozzle plug performance was accomplished. Prior to motor ignition, the field joints were maintained between 75 to 130 F, the igniter-to-case joint was maintained between 75 to 123 F, and the case-to-nozzle joint was maintained between 75 to 120 F. QM-8 was tested with induced side loads to simulate the strut loads experienced during ignition and maximum aerodynamic loading conditions. The ability of the safe and arm device to change position from safe-to-arm and arm-to-safe was certified. Ballistics performance was certified at the lower limits. Values were within specification requirements. Nozzle performance was nominal with typical erosion. The use of Fiberite carbon-cloth phenolic was certified. The water deluge system, CO2 quench, and other test equipment performed as planned during all required test operations.

Garecht, D. M.↗

Wormhole Formation in RSRM Nozzle Joint Backfill

The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and predictions. Finally, two candidate replacement materials are being screened and "validated" using the developed test systems.

Stevens, J.↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures

Lightweight, electromagnetic interference (EMI) immune, fiber-optic, sensor- based structural health monitoring (SHM) will play an increasing role in aerospace structures ranging from aircraft wings to jet engine vanes. Fiber Bragg Grating (FBG) sensors for SHM include advanced signal processing, system and damage identification, and location and quantification algorithms. Potentially, the solution could be developed into an autonomous onboard system to inspect and perform non-destructive evaluation and SHM. A novel method has been developed to massively multiplex FBG sensors, supported by a parallel processing interrogator, which enables high sampling rates combined with highly distributed sensing (up to 96 sensors per system). The interrogation system comprises several subsystems. A broadband optical source subsystem (BOSS) and routing and interface module (RIM) send light from the interrogation system to a composite embedded FBG sensor matrix, which returns measurand-dependent wavelengths back to the interrogation system for measurement with subpicometer resolution. In particular, the returned wavelengths are channeled by the RIM to a photonic signal processing subsystem based on powerful optical chips, then passed through an optoelectronic interface to an analog post-detection electronics subsystem, digital post-detection electronics subsystem, and finally via a data interface to a computer. A range of composite structures has been fabricated with FBGs embedded. Stress tensile, bending, and dynamic strain tests were performed. The experimental work proved that the FBG sensors have a good level of accuracy in measuring the static response of the tested composite coupons (down to submicrostrain levels), the capability to detect and monitor dynamic loads, and the ability to detect defects in composites by a variety of methods including monitoring the decay time under different dynamic loading conditions. In addition to quasi-static and dynamic load monitoring, the system can capture acoustic emission events that can be a prelude to structural failure, as well as piezoactuator-induced ultrasonic Lamb-waves-based techniques as a basis for damage detection.

Moslehi, Behzad↗

ME8373 Spring 2015 ICME Proposal ICME Analysis of Fatigue Crack Growth Through a Weld in SA-516 Grade 70 Plate

This paper describes work accomplished to predict the service life of a flexure joint design which is a component of a diffuser duct in the A3 Test Stand, an altitude simulation rocket engine test facility at NASA's Stennis Space Center. The duct has two pressure shells separated by cooling water passages and connected by stiffening ribs and flexure joints. Rocket exhaust flows within the duct and heats the inner pressure shell while the outer pressure shell remains at ambient temperature. The flexure joints allow for differential thermal expansion of the inner and outer pressure shells and are subject to in-service loading by this thermal expansion along with water pressure in the cooling water passage, atmospheric pressure outside the duct, near vacuum conditions within the duct, and vibrational loads from operation of the facility and rocket engine. Figure 1 shows a schematic axisymmetric cross section of the diffuser pressure shells and flexure joints with a zoomed in view of the flexure joint. The flexure joints are expected to eventually fail by fatigue cracking leading to leaks from the cooling water passages to the outside. The zoomed in view in Figure 1 indicates where cracking is expected to occur, namely through a weld bead between two plates of SA-516 Grade 70 steel. This weld bead acts as the fulcrum of the flexure joint and it is clear from inspection of the geometry and loading represented in the zoomed in portion of Figure 1 that inherent in the design there is a severe notch formed between the flexure plate, weld bead, and stiffening ring that will be the site of crack initiation and location from which the crack grows to the outer surface of the weld bead.

Woods, Jody L.↗

Modified Epoxy Matrix Resins for Reduced Dependence on Redundant Fasteners in Secondary-Bonded Composite Structures

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination that can lead to weak bonds. No methods currently exist to measure the strength of an adhesive bond nondestructively. For these reasons, regulating organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to achieve certification for civil transport aircraft. To meet this requirement, manufacturers commonly install redundant fasteners (~105 fasteners in a twin-aisle airframe with composite fuselage and wings), which add tremendous complexity, time and cost, and significantly reduce performance of the airframe. Under NASA’s Convergent Aeronautics Solutions (CAS) Program, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy matrix resins to enable reflow and diffusion of the resin at the interface during a secondary bonding/cure process. The mixing process eliminates the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion across a nearly two-dimensional boundary. The AERoBOND interface is similar to the interlaminar region formed during a co-cure process, so joint performance depends on the cohesive properties of the matrix resin, which can be measured, inspected non-destructively, and certified for flight with fewer redundant fasteners. This presentation describes the ongoing development of stoichiometrically-offset epoxy resins to control the degree of cure in composite joints and enable interfacial mixing during secondary bonding/curing. Details on the resin formulation, laminate fabrication, and mechanical testing will also be presented. The precracked mode-II fracture toughness measured from preliminary AERoBOND joints was similar for joints fabricated with conventional epoxy matrix materials.

thermoset, hardener, prepreg, assembly↗