Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Volcano‐like Activity Trends in Au@Pd Catalysts: The Role of Pd Loading and Nanoparticle Size

The addition of palladium (Pd) to preformed gold nanoparticles (Au NPs) enables the formation of core‐shell structures with enhanced catalytic performance in oxidation reactions. However, predicting the precise palladium content required to achieve maximum catalytic activity remains difficult based on current understanding. Herein, Pd was systematically introduced onto titania‐supported Au NPs (2, 6, and 10 nm) to evaluate their performance in benzyl alcohol oxidation. A volcano‐like trend in catalytic activity was observed, where activity increased with Pd addition, peaked, and then declined. The Pd loading required for maximum activity depended on Au NP size: ≈40 at% Pd/Au for 2.6 nm, ≈20 at% Pd/Au for 6.4 nm, and ≈12.5 at% Pd/Au for 10.6 nm. For Au NPs > 6 nm, peak activity aligned with monolayer Pd coverage, while for smaller NPs (2–3 nm), optimal Pd content was below monolayer predictions. X‐ray absorption spectroscopy revealed a core‐shell structure at low Pd content, but higher Pd loadings led to Pd diffusion into the Au core. This structural transformation likely caused activity decline, indicating that AuPd alloying negatively impacts catalysis. These results highlight that core‐shell Au@Pd catalysts outperform AuPd alloys and provide crucial insights for designing highly active bimetallic catalysts.

X-ray absorption spectroscopy↗

Biocatalytic Carboxylic Acid Reduction and Transamination in Cell‐Free Lysates at High Substrate Loading

Chemoselective reduction of stable carboxylic acids to reactive aldehydes is of interest across many industries. While carboxylic acid reductases (CARs) are promising biocatalysts for this chemistry, poor chemoselectivity and low yield are commonly obtained when using less expensive crude lysate preparations and prerequisite ATP and NADPH regeneration systems. Here, in this work, we developed a highly chemoselective multienzyme cascade featuring a CAR and an ω-transaminase (TA) in crude lysate format, with conversion of the dicarboxylic acid terephthalic acid (TPA) into the diamine para -xylylenediamine (pXDA) as the model chemistry. We improved chemoselectivity for pXDA using engineered aldehyde-stabilizing Escherichia coli strains, though desired product yields remained modest. We next found that CAR activity was limited at high substrate loadings and overcame this bottleneck by modulating the ratio of polyphosphate (polyP 6 ) to Mg 2+ , enabling volumetric scaling and increased substrate loading up to 50 mM TPA. We then showcased the portability of this platform across substrates, resulting in the synthesis of four other high-value amines from carboxylate precursors. The combination of high carboxyl group turnover, up to 93.5 mM under the tested conditions, and the simplicity of crude enzyme preparation is a promising platform for sustainable functional group interconversion.

60 APPLIED LIFE SCIENCES↗

Microgrid design and multi-year dispatch optimization under climate-informed load and renewable resource uncertainty

Microgrids are an increasingly popular solution to provide energy resilience in response to increasing grid dependency and the growing impacts of climate change on grid operations. However, existing microgrid models do not currently consider the uncertain and long-term impacts of climate change when determining a set of design and operational decisions to minimize long-term costs or meet a resilience threshold. In this paper, we develop a novel scenario generation method that accounts for the uncertain effects of (i) climate change on variable renewable energy availability, (ii) extreme heat events on site load, and (iii) population and electrification trends on load growth. Additionally, we develop a two-stage stochastic programming extension of an existing microgrid design and dispatch optimization model to obtain uncertainty-informed and climate-resilient energy system decisions that minimizes long-term costs. Use of sample average approximation to validate our two case studies illustrates that the proposed methodology produces high-quality solutions that add resilience to systems with existing backup generation while reducing expected long-term costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification of [MTBD][beti] loading and its effects on Pt/HSC electrode performance in hydrogen fuel cells

High surface area carbon-supported platinum catalysts (Pt/HSC) are widely used in polymer electrolyte membrane fuel cells but often suffer from limited proton and oxygen transport within porous domains. To address these challenges, we integrate the ionic liquid [MTBD][beti] into Pt/HSC catalyst layers using two deposition methods-one-pot and sequential deposition-to tune IL distribution within micropores and mesopores. A combination of ex situ and in operando techniques were employed to elucidate electrode structure-performance relationships across a range of IL loadings. Sequential deposition achieved more efficient pore filling and higher IL retention at lower IL:C ratios, enabling enhanced proton conductivity and protection of active sites. Compared to the IL-free Pt/HSC, IL-modified electrodes demonstrated up to 28% improvement in mass activity and enhanced high-current-density performance under low relative humidity, while maintaining comparable performance under humidified conditions. Electrochemical impedance spectroscopy and CO displacement experiments reveal that improvements are linked to reduced ionic resistance and lower sulfonate adsorption on Pt sites, rather than changes in electrochemical surface area. However, excessive IL loading leads to mass transport losses. These results highlight the importance of selective pore filling and efficient IL distribution in achieving kinetic gains without compromising ionic and gas transport.

08 HYDROGEN↗

Unsteady aerodynamic loads on pitching aerofoils represented by Gaussian body force distributions

The actuator line model (ALM) is an approach commonly used to represent lifting and dragging devices like wings and blades in large-eddy simulations (LES). The crux of the ALM is the projection of the actuator point forces onto the LES grid by means of a Gaussian regularisation kernel. The minimum width of the kernel is constrained by the grid size; however, for most practical applications like LES of wind turbines, this value is an order of magnitude larger than the optimal value that maximises accuracy. This discrepancy motivated the development of corrections for the actuator line, which, however, neglect the effect of unsteady spanwise shed vorticity. In this work we develop a model for the impact of spanwise shed vorticity on the unsteady loading of an aerofoil modelled as a Gaussian body force distribution, where the model is applicable within the regime of unsteady attached flow. The model solution is derived both in the time and frequency domain and features an explicit dependence on the Gaussian kernel width. We verify the model with ALM-LES for both pitch steps and periodic pitching. The model solution is compared with Theodorsen theory and validated with both computational fluid dynamics using body fitted grids and experiment. It is concluded that the optimal kernel width for unsteady aerodynamics is approximately 40 % of the chord. The ALM is able to predict the magnitude of the unsteady loading up to a reduced frequency of 𝑘 ≈ 0.2.

17 WIND ENERGY↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rational design of high-performance low-loading oxygen reduction catalysts for alkaline fuel cells

The lack of mechanistic understanding and catalyst design principles for alkaline electrolytes, especially for the sluggish oxygen reduction reaction, has impeded the advancement of alkaline fuel cells. Here, in this study, we propose a modified volcano plot and apply this rationale to strategically design Pt nanosheets with PdH x nanosheets substrates. This catalyst exhibited high stability with a specific activity of 1.71 mA cm −2 at 0.95 V versus the reversible hydrogen electrode, surpassing the benchmark of Pt/C by 49-fold. Spectroscopic, electrochemical and electron microscopic characterizations revealed that such performance enhancement originated from tensile-strained Pt{111} facets, improving oxidative stability and suppressing carbon corrosion. In fuel cell testing, the catalyst enabled a peak power density of 1.67 W cm −2 with a loading of 10 µg PGM Cathode cm −2 . Further optimization delivered a peak power density of 21.7 W mg −1 PGM Cathode+Anode with a total specific catalyst cost US$\$$1.27 kW −1 , surpassing the US Department of Energy’s Pt group metal loading and cost targets. This study provides valuable insights into catalyst design for the alkaline oxygen reduction reaction.

36 MATERIALS SCIENCE↗

3D printing of architected sulfur cathodes with dual-site atomic catalysts for accelerated polysulfide kinetics and Li-ion transport in high areal-loading lithium–sulfur batteries

The practical deployment of lithium–sulfur batteries (LSBs) is hindered by fundamental limitations in conventional slurry-cast cathodes, including poor sulfur utilization, sluggish ion transport, and low areal capacity, particularly in thick electrodes required for high energy density. To address these challenges, we present direct ink writing (DIW) as an additive manufacturing strategy to fabricate advanced current-collector-free, 3D-printed sulfur cathodes (3DP S@CoNi-DSACs/NC) with hierarchically porous architectures that enhance lithium-ion diffusion, promote electrolyte penetration, and reduce interfacial resistance. The synergistic effects of Co/Ni dual-atom sites accelerate redox kinetics and mitigate polysulfide shuttling. As a result, the optimized 3DP cathode with a sulfur loading of 5.4 mg cm −2 demonstrated excellent rate capability, delivering a high reversible capacity of 1041.4 mAh g −1 at 1C with 85.5% capacity retention after 1000 cycles, significantly outperforming its cast counterpart. Remarkably, even at a higher sulfur loading of 8.1 mg cm −2 , the 3DP cathode maintains outstanding performance, achieving a discharge capacity of 1538.4 mAh g −1 and an areal capacity of 12.5 mAh cm −2 at 0.1C. This study not only demonstrates the functional integration of catalytically active materials into 3D printable sulfur cathode architectures but also offers a scalable and transformative platform for building high-performance LSBs beyond conventional electrode manufacturing methods.

3D electrode↗

Excessive charge, beam loading, and impedance collapse thresholds for a velvet emitter

Excess emission has been observed from velvet cathodes with total emission times >150 ns. In this diode experiment, we produce a sub-relativistic electron beam with the ability to consistently change γ from 1.2 to 1.5 and β = 0.5–0.75. Electron emission in this particular diode geometry requires electric fields >40 kV/cm. The current increases at steady rates >0.05 A/ns after the head of the pulse, indicating an expansion of the emission surface and reduction in the effective AK gap. Small transients of excess emission (or arcs) are consistently observed for current pulses exceeding 150 ns. The excess emission results in beam loaded levels ≥10 kV on the diode voltage. The effects described here are compounded as diode voltage is increased. The principal objective of these experiments is to quantify electric field emission thresholds, current ramps, excess emission delays, effective beam loading, and impedance collapse.

43 PARTICLE ACCELERATORS↗

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell↗

OC7 Project Phase II: Code Comparison and Experimental Validation of Hydroelastic Effects and Member-Level Loads in Floating Structures

This paper presents results from Phase II of the OC7 project, focusing on hydroelastic modeling and member-level load prediction for a flexible floating offshore structure. Numerical predictions from 11 academic and industrial partners are validated against experimental measurements obtained from a 1:70-scale test of the VolturnUS-S semisubmersible platform. A comprehensive set of verification and validation cases is examined. The results demonstrate that hydrodynamic added mass has a significant impact on predicted elastic natural frequencies. Under regular wave excitation, the numerical models reproduce platform motions and mooring line tensions with good accuracy. Member-level loads are also predicted with reasonable accuracy. Some discrepancies are observed for potential-flow models not accounting for higher-order effects associated with the instantaneous wetted surface.

17 WIND ENERGY↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Grid-Forming Split-Phase Three-Leg Inverter with Unbalanced Loading and Active Power Decoupling

This paper presents a split-phase three-leg inverter that regulates 180-degree phase-shifted AC voltages to support residential house loads under unbalanced loading conditions and decouples double line frequency power pulsation by utilizing the third half-bridge switching leg. The active power decoupling function is added without extra active switching components. The control feasibility and effectiveness are verified through MATLAB Simulink simulation and controller hardware-in-the-loop test.

Kim, Namwon [ORNL] (ORCID:0000000200438489)↗

Study on Conversion from an Existing Alternating Current Medium-Voltage Line to a Direct Current Line: A Case of Load or Source Expansion

Simultaneous increase of power generation through renewable systems and load due owing to the rapid growth in electrified road transportation systems, leads to new challenges in the design, operation, and protection of distribution-level electrical power systems. This paper addresses challenges related to the integration of new sources or loads to a distribution grid through long alternating current lines. The International Council on Large Electric Systems medium-voltage benchmark model developed for North America was used for simulation studies. Use cases were developed to illuminate the issues related to long alternating current lines and the usefulness of medium-voltage direct current lines in a distribution network.

Jaldanki, Sreenivasa↗

Load Matching Potential of Urban Renewables during Extreme Heat in New York City

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on the matter by assessing the feasibility of using offshore wind and rooftop photovoltaic systems to meet electricity demand during a period of thermal stress in New York City—August 2019. A unified modelling framework, based on the Urbanized Weather Research and Forecasting model, is used to simulate climate, renewable resources and energy demand variables. Findings show significant energy load miss-match, ranging from 3 to 5 GW, between the demand and the composite renewable generation outcome. This study provides a transferable framework for evaluating renewable integration in dense urban regions and highlights the need for additional strategies to support grid resilience during extreme heat events, while clarifying the role of local resources in fully managing NYC’s load.

54 ENVIRONMENTAL SCIENCES↗

A Stochastic Framework for Estimating Load Profiles at EV Fast Charging Stations

This paper formulates a methodology for estimating the average daily load profiles of EV fast charging stations over a planning horizon of five to ten years. The developed methodology uses historic vehicle registration data, state-level EV adoption targets, seasonal driving patterns, local demographics, competition, and traffic volume information to predict average station usage. Through Monte Carlo simulations, an average daily load profile is obtained for each month in the planning horizon, and prediction uncertainty is quantified. The proposed framework will facilitate the accurate estimation of energy and demand costs incurred by the charging station over the planning period, thereby informing return-on-investment calculations.

Biswas, Shuchismita↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗