Analysis of a Small Loop Antenna With Inductive Coupling to Nearby Loops
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.
Abstract not provided
The goal of this report is to explain how to estimate the cable voltage in a changing magnetic field surrounded by a metal structure.
Pumped storage hydropower (PSH) is a type of energy storage that uses the pumping and release of water between two reservoirs at different elevations to store water and generate electricity (Figure ES-1). When demand for electricity is low, a PSH project can use low cost energy to pump water from the lower reservoir to the upper reservoir for storage. When demand for electricity is high, a PSH project can release water from the upper reservoir through a powerhouse to generate electricity. Traditionally, this meant that PSH plants generated power during the day and pumped at night, with modest diurnal or seasonal variation.
Explore the source record for details and available documents.
Extension of control function to neighborhood of reference trajectory to obtain feedback control
Four different types of self-tuning regulators were studied for multicyclic control of helicopter vibration. A numerical simulation of the helicopter is made, using a multivariable frequency-domain model, in terms of transfer function with six input control harmonics and six output harmonics. The model characteristics vary with flight speed. An off-line identification of model characteristics is made, using the least-squared-error method and using a succession of input and output measurements. The on-line identification of model characteristics is made using the Kalman filter solution. The optimal controls are calculated from the minimization of quadratic performance function based on response and multicyclic inputs. The performance of various regulators or controllers is judged from the stability, transient response, convergence time, and amplitude of the steady state.
No abstract available
Explore the source record for details and available documents.
No abstract prepared.
In order to investigate the systematics of the loop expansion in high temperature gauge theories beyond the leading order hard thermal loop (HTL) approximation, we calculate the two-loop electron proper self-energy {Sigma} in high temperature QED. The two-loop bubble diagram of {Sigma} contains a linear infrared divergence. Even if regulated with a nonzero photon mass M of order of the Debye mass, this infrared sensitivity implies that the two-loop self-energy contributes terms to the fermion dispersion relation that are comparable to or even larger than the next-to-leading order (NLO) contributions of the one-loop {Sigma}. Additional evidence for the necessity of a systematic restructuring of the loop expansion comes from the explicit gauge-parameter dependence of the fermion damping rate at both one and two loops. The leading terms in the high temperature expansion of the two-loop self-energy for all topologies arise from an explicit hard-soft factorization pattern, in which one of the loop integrals is hard (p{approx_equal}T), nested inside a second loop integral which is soft (0{<=}p < or approx. T for real parts; p{approx_equal}eT for imaginary parts). There are no hard-hard contributions to the two-loop {Sigma} at leading order at high T. Provided the same factorization pattern holds for arbitrary l loops, the NLO high temperature contributions to the electron self-energy come from l-1 hard loops factorized with one soft loop integral. This hard-soft pattern is a necessary condition for the resummation over l to coincide with the one-loop self-energy calculated with HTL dressed propagators and vertices, and to yield the complete NLO correction to {Sigma} at scales {approx}eT, which is both infrared finite and gauge invariant. We employ spectral representations and the Gaudin method for evaluating finite temperature Matsubara sums, which facilitates the analysis of multiloop diagrams at high T.
This report provides an update on the completion of long-lead components procurement of new sodium materials test loop. The loop, designated as SMT-3, is a forced-convection sodium loop to be used for the evaluation of sodium compatibility of advanced Alloy 709 with emphasis on long term exposures of tensile, creep, fatigue, creep fatigue, and fracture toughness ASTM-size specimens in support of ASME Code qualification and NRC licensing. The report is a deliverable (Level 4) in FY18 (M4NT-18AN050503013), under the Work Package NT-18AN05050301, “A709 Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of the Advanced Materials Program for the Advanced Reactor Technology. This work package enables the development of advanced structural materials by providing corrosion, microstructure, and mechanical property data from the standpoint of sodium compatibility of advanced structural alloys. The first sodium loop (SMT-1) with a single tank was constructed in 2011 at ANL and has been in operation for exposure of subsize sheet specimens of advanced alloys at a single temperature. The second sodium loop with dual tanks (SMT-2) was constructed in 2013 and has been in operation for the exposure of subsize sheet specimens of advanced alloys at two different temperatures. The current loop (SMT-3) has been designed to incorporate sufficient chamber capacity to expose a large number of ASTM-size specimens to evaluate the sodium effects on tensile, creep, fatigue, creep-fatigue, and fracture toughness properties, in support of ASME Code Qualification and USNRC Licensing. Three major long lead items were identified: 1) Selection and approval of location for the new loop and installation of the necessary infrastructure, such as transformer, power supply panels, and wiring, that is adequate for the long term operation of the loop, 2) Perform a detailed piping analysis that meets the ANL QA and Safety guidelines as well as complying with ASME Code requirements, and 3) Design and fabrication of the specimen exposure vessels that are capable of at least 42 tensile, creep, and fatigue specimens in each vessel and is compliant and compatible with ASME Code and the piping design analysis. The SMT-3 loop will be located in Building 206 adjacent to the currently operating SMT-2 loop. In addition, we have removed the aged power supply system in Building 206 and installed a new transformer, wiring, and power panels for the new loop. The preliminary loop design was sent to an outside vendor for a detailed piping analysis, to ensure compliance with the ASME Code guidelines. The piping design was completed in FY2017. The construction of components such as cold trap, economizers, piping arrangement etc. will be performed in the central shops at ANL. About 150 liters of sodium for the loop will be procured in early FY2018. The loop system is designed to circulate sodium through the sample tanks and he associated loop without an operator for an extended period of time. With the three sodium loops (i.e., single-tank, dual-tank and four–tank), materials can be tested at different sodium temperatures, and large tensile, creep, fatigue, creep-fatigue, and fracture toughness specimens can be exposed to sodium for extended periods of time and generate data on mechanical properties in support of ASME Code Qualification and USNRC Licensing of advanced Alloy 709 for use as a structural material in SFRs.
Previous characterization of hemophores from Serratia marcescens (HasAs), Pseudomonas aeruginosa (HasAp), and Yersinia pestis (HasA yp ) showed that hemin binds between two loops, where it is axially coordinated by H32 and Y75. The Y75 loop is structurally conserved in all three hemophores and harbors conserved ligand Y75. The other loop contains H32 in HasAs and HasAp, but a noncoordinating Q32 in HasA yp . The H32 loop in apo-HasAs and apo-HasAp is in an open conformation, which places H32 about 30 Å from the hemin-binding site. Hence, hemin binding onto the Y75 loop of HasAs or HasAp triggers a large relocation of the H32 loop from an open- to a closed-loop conformation and enables coordination of the hemin-iron by H32. In comparison, the Q32 loop in apo-HasA yp is in the closed conformation, and hemin binding occurs with minimal reorganization and without coordinative interactions with the Q32 loop. Studies in crystallo and in solution have established that the open H32 loop in apo-HasAp and apo-HasAs is well structured and minimally affected by conformational dynamics. In this study we address the intriguing issue of the stability of the H32 loop in apo-HasAp and how hemin binding triggers its relocation. Specifically, we address this question with a combination of NMR spectroscopy, X-ray crystallography, and molecular dynamics simulations and find that R33 is critical to the stability of the open H32 loop. Replacing R33 with A causes the H32 loop in R33A apo-HasAp to adopt a conformation similar to that of holo-HasAp. Finally, stopped-flow absorption and resonance Raman analyses of hemin binding to apo-R33A HasAp indicate that the closed H32 loop slows down the insertion of the heme inside the binding pocket, presumably as it obstructs access to the hydrophobic platform on the Y75 loop, but accelerates the completion of the heme iron coordination.
Coronal loops on the surface of the sun appear to consist of curved, plasma-confining magnetic flux tubes or “ropes,” anchored at both ends in the photosphere. Toroidal loops carrying current are inherently unstable to expansion in the major radius due to toroidal-curvature-induced imbalances in the magnetic and plasma pressures. An ideal MHD analysis of a simple isolated loop with density and pressure higher than the surrounding corona, based on the theory of magnetically confined toroidal plasmas, shows that the radial force balance depends on the loop internal structure and varies over parameter space. It provides a unified picture of simple loop steady states in terms of the plasma beta β o , the inverse aspect ratio ϵ = a/R o , and the MHD gravitational parameter $\hat{G}$ ≡ ga/v$2\atop{A}$, all at the top of the loop, where g is the acceleration due to gravity, a the average minor radius, and v A the shear Alfvén velocity. In the high and low beta tokamak orderings, β o = 2n o T/(B$2\atop{0}$/2μ o ) ~ ϵ 1 and ϵ 2 , that fit many loops, the solar gravity can sustain nonaxisymmetric steady states at $\hat{G}$ ~ ϵβ o that represent the maximum stable height. At smaller \hat{G} ≤ ϵ 2 β o , the loop is axisymmetric to leading order and stabilized primarily by the two fixed loop ends. Very low beta, nearly force-free, steady states with β o ~ ϵ 3 may also exist, with or without gravity, depending on higher order effects. The thin coronal loops commonly observed in solar active regions have ϵ ≃ 0.02 and fit the high beta steady states. $\hat{G}$ increases with loop height. Fatter loops in active regions that form along magnetic neutral lines and may lead to solar flares and Coronal Mass Ejections have ϵ ≃ 0.1–0.2 and may fit the low beta ordering. Larger loops tend to have $\hat{G}$ > ϵβ o and be unstable to radial expansion because the exponential hydrostatic reduction in the density at the loop-top reduces the gravitational force -ρ$\hat{G}\hat{R}$ below the level that balances expansion, also in agreement with the observation that most sufficiently large loops grow.