Search NASA⌕ Search

SEARCH · Search NASA

Results for “lost load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The structural OFF and ON states of myosin can be decoupled from the biochemical super- and disordered-relaxed states

Abstract There is a growing awareness that both thick-filament and classical thin-filament regulations play central roles in modulating muscle contraction. Myosin ATPase assays have demonstrated that under relaxed conditions, myosin may reside either in a high-energy-consuming disordered-relaxed (DRX) state available for binding actin to generate force or in an energy-sparing super-relaxed (SRX) state unavailable for actin binding. X-ray diffraction studies have shown that the majority of myosin heads are in a quasi-helically ordered OFF state in a resting muscle and that this helical ordering is lost when myosin heads are turned ON for contraction. It has been assumed that myosin heads in SRX and DRX states are equivalent to the OFF and ON states, respectively, and the terms have been used interchangeably. In this study, we use X-ray diffraction and ATP turnover assays to track the structural and biochemical transitions of myosin heads, respectively, induced with either omecamtiv mecarbil (OM) or piperine in relaxed porcine myocardium. We find that while OM and piperine induce dramatic shifts of myosin heads from the OFF to the ON state, there are no appreciable changes in the population of myosin heads in the SRX and DRX states in both unloaded and loaded preparations. Our results show that biochemically defined SRX and DRX can be decoupled from structurally defined OFF and ON states. In summary, while SRX/DRX and OFF/ON transitions can be correlated in some cases, these two phenomena are measured using different approaches, reflect different properties of the thick filament, and should be investigated and interpreted separately.

Jani, Vivek P. (ORCID:0000000238114973)↗

WRATS Integrated Data Acquisition System

The Wing and Rotor Aeroelastic Test System (WRATS) data acquisition system (DAS) is a 64-channel data acquisition display and analysis system specifically designed for use with the WRATS 1/5-scale V-22 tiltrotor model of the Bell Osprey. It is the primary data acquisition system for experimental aeroelastic testing of the WRATS model for the purpose of characterizing the aeromechanical and aeroelastic stability of prototype tiltrotor configurations. The WRATS DAS was also used during aeroelastic testing of Bell Helicopter Textron s Quad-Tiltrotor (QTR) design concept, a test which received international attention. The LabVIEW-based design is portable and capable of powering and conditioning over 64 channels of dynamic data at sampling rates up to 1,000 Hz. The system includes a 60-second circular data archive, an integrated model swashplate excitation system, a moving block damping application for calculation of whirl flutter mode subcritical damping, a loads and safety monitor, a pilot-control console display, data analysis capabilities, and instrumentation calibration functions. Three networked computers running custom-designed LabVIEW software acquire data through National Instruments data acquisition hardware. The aeroelastic model (see figure) was tested with the DAS at two facilities at NASA Langley, the Transonic Dynamics Tunnel (TDT) and the Rotorcraft Hover Test Facility (RHTF). Because of the need for seamless transition between testing at these facilities, DAS is portable. The software is capable of harmonic analysis of periodic time history data, Fast Fourier Transform calculations, power spectral density calculations, and on-line calibration of test instrumentation. DAS has a circular buffer archive to ensure critical data is not lost in event of model failure/incident, as well as a sample-and-hold capability for phase-correct time history data.

Piatak, David J.↗

Photocatalytic CO{sub 2} reduction by CH{sub 4} over montmorillonite modified TiO{sub 2} nanocomposites in a continuous monolith photoreactor

Highlights: • TiO{sub 2}/MMT supported monolith photo-reactor was tested for CO{sub 2} reduction with CH{sub 4}. • MMT inhibited crystal growth and enhanced TiO{sub 2} photo-activity in monolith reactor. • CO{sub 2} was reduced by CH{sub 4} to CO, CH{sub 3}OH, C{sub 2}H{sub 6}, C{sub 3}H{sub 6} and C{sub 3}H{sub 8} in a monolith reactor. • CO yield over TiO{sub 2}/MMT was 237.5 μmol g-catal.{sup −1} h{sup −1}, a 2.52 fold than TiO{sub 2}. • Stability test revealed TiO{sub 2}/MMT partially lost photo-activity in reused cyclic runs. - Abstract: In this study, the performance of montmorillonite (MMT) modified TiO{sub 2} nanocomposites for photocatalytic CO{sub 2} reduction with CH{sub 4} in a continuous monolith photoreactor has been investigated. The MMT modified TiO{sub 2} nanocomposites were dip-coated over monolith channels and were characterized by XRD, SEM, TEM, XPS, N{sub 2}-adsorption–desorption and UV–vis spectroscopy. The MMT produced anatase phase of TiO{sub 2} and reduced TiO{sub 2} crystallite size from 19 nm to 13 nm. CO was the major reduction product with a yield rate of 237.5 μmol g-catal.{sup −1} h{sup −1} over 10 wt.% MMT-loaded TiO{sub 2} at 100 °C, and CO{sub 2}/CH{sub 4} feed ratio 1.0. The photoactivity of MMT-loaded TiO{sub 2} monolithic catalyst was 2.52 times higher than bare TiO{sub 2}. Likewise, low concentrations of C{sub 2}H{sub 6}, CH{sub 3}OH, C{sub 3}H{sub 6} and C{sub 3}H{sub 8} were detected in the products mixture. These results inferred MMT modified TiO{sub 2} and monolith photoreactor were beneficial for enhancing photocatalysis process with appreciable productivity. The stability test revealed photoactivity of MMT-loaded TiO{sub 2} nanocomposites partially diminished in recycle runs.

36 MATERIALS SCIENCE↗

Exergy Analysis of a Two-Stage Ground Source Heat Pump with a Vertical Bore for Residential Space Conditioning under Simulated Occupancy

This twelve-month field study analyzes the performance of a 7.56W (2.16- ton) water-to-air-ground source heat pump (WA-GSHP) to satisfy domestic space conditioning loads in a 253 m 2 house in a mixed-humid climate in the United States. The practical feasibility of using the ground as a source of renewable energy is clearly demonstrated. Better than 75% of the energy needed for space heating was extracted from the ground. The average monthly electricity consumption for space conditioning was only 40 kWh at summer and winter thermostat set points of 24.4°C and 21.7°C, respectively. The WA-GSHP shared the same 94.5 m vertical bore ground loop with a separate water-to-water ground-source heat pump (WW-GSHP) for meeting domestic hot water needs in the same house. Sources of systemic irreversibility, the main cause of lost work are identified using Exergy and energy analysis. Quantifying the sources of Exergy and energy losses is essential for further systemic improvements. The research findings suggest that the WA-GSHPs are a practical and viable technology to reduce primary energy consumption and greenhouse gas emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources.

15 GEOTHERMAL ENERGY↗

Improving Flexibility and Performance of Staged Pressurized Oxy-Combustion

Staged pressurized oxy-combustion (SPOC) is a novel coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Oxy-combustion plants operate by removing most of the nitrogen contained in air prior to combustion, thereby burning fuel in a near-pure oxygen stream instead of air. This combustion produces a flue gas containing primarily carbon dioxide (CO 2 ) and water vapor that allows relatively straightforward CO 2 capture. First-generation, atmospheric oxy-combustion technology relies on a flue gas recycle (FGR) diluent to reduce the peak temperatures achieved and the resulting high thermal radiation levels that would otherwise occur in a fuel/oxygen only flame. In contrast, by staging the combustion in several steps, SPOC reduces the peak temperatures of combustion without resorting to a high degree of FGR to control flame temperatures. The SPOC process operates by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given combustion module. Subsequently the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. While the staging controls the heat release profile in SPOC, operating in a pressurized condition yields a more compact system, reducing modular boiler size and delivering enhanced heat transfer. Additionally, operating at elevated pressures ensures that the latent heat of moisture available from moisture in the fuel and generated by the combustion of the hydrogen content in the fuel can be captured as useful thermal energy for steam turbine integration. This is possible due to elevated dew point from the high partial pressure of the moisture generated in this process, which allows substantial feedwater heater bypassing to be achieved. The inclusion of this thermal energy, normally lost to the atmosphere in traditional combustion processes or to cooling systems in atmospheric oxy-combustion, allows the resultant net efficiency of the SPOC system to be up to 6 percentage points greater than first-generation systems. To begin the process of developing this technology for full-scale application, the Electric Power Research Institute, Inc. teamed up with WUSTL, American Air Liquide, Doosan Babcock, and the U.S. Department of Energy to investigate a practical and workable boiler design concept that would minimize process risks where possible. The SPOC system offers unique process flexibility opportunities due to the staged nature of the combustion, making it a prime candidate for future primary energy delivery where the ability to operate at reduced load in an efficient manner and ramp rapidly will be valuable for balancing intermittent renewable electricity generation. The efficiency of traditional coal-fired power plants is lower at reduced loads below the steam temperature control range due to the challenges in balancing the heat pickup between radiative and convective superheater and reheater surface. Introducing additional heating surface for optimal extended controlled low load operation will likely lead to excessive attemperation at high loads, ultimately leading to a poorer overall cycle efficiency. The SPOC process can facilitate the adjustment of fuel firing rates between stages, targeting heat pickup to where it is most needed and potentially can shut down stages for low-load operation, facilitating an increased steam temperature control range on turndown. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the potential resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Parameters being investigated include flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. These are being carried out for a range of inlet gas conditions and compositions and at multiple load conditions to investigate combustion stability at reduced load. The results of this testing inform the modeling of the large-scale system, that was sized at 550 MWe to allow direct comparison with the National Energy Technology Laboratory baseline cases for atmospheric oxy-combustion, air firing, and air firing with post-combustion capture.

20 FOSSIL-FUELED POWER PLANTS↗

Stripping Uranium from Seawater-Loaded Sorbents with the Ionic Liquid Hydroxylammonium Acetate in Acetic Acid for Efficient Reuse

A new stripping and recovery process was developed to harvest the uranium recovered from seawater with amidoxime-functionalized polyethylene fiber sorbents and allow reuse of the sorbent without loss of capacity and without the need to recondition the sorbent before reuse. Hydroxylammonium acetate ([NH 3 OH][OAc])/aqueous acetic acid (AcOH) solutions were used as weakly acidic stripping agents and the stripped uranium as a soluble acetate was further immobilized on shrimp shells. These solutions also stripped the vanadium and other metal ions coadsorbed, which reduce capacity through competition with uranium for sorbent binding and can resist stripping even by strong acids. [NH 3 OH][OAc]/AcOH was found to allow recovery of more than 85% of the uranium although at a substantial longer time than the current 0.5 M HCl-stripping solutions, (less than 12 h vs 48-72 h, respectively); however, the use of HCl severely compromises the capacity of the sorbent in subsequent reuse (a 50% lost was observed on the third reuse of the fiber). Both [NH 3 OH][OAc] and the acetic acid were necessary to achieve high uranium recovery without sacrificing the sorbent’s capacity on reuse. Finally, the ability to reuse the sorbent without pretreatment and with minimal capacity loss could be an important step toward making the extraction of uranium from seawater energy-efficient and economically viable.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Phase 1 Final Technical Report - MgB2 Synthesis for High Field Performance

Accelerator Technology Corp. (ATC) has successfully completed its Phase 1 effort to devel-op rf plasma torch synthesis of MgB2 superconducting powder. The overall objective is to de-velop a way to introduce homogeneous alloying of C and SiC impurities into phase-pure MgB2. Several groups have attained remarkable benefits from such alloying in raising the upper critical field Hc2 from ~14 T to ~30 T (bulk) and ~50 T (thin films). But no one has succeeded in pro-ducing that benefit homogeneously, so that current transport in a practical powder-in-tube (PIT) conductor is largely the same as without the alloying. ATC has conceived the possibility of attaining such homogeneity by passing aerosol suspen-sions of reactant powders through an rf plasma torch, with each reactant transported on a stream-line that heats it to an optimum temperature for the synthesis reaction. This procedure would uniquely access non-equilibrium kinetics for the synthesis reaction, and would provide the possi-bility to separately control the temperature and stoichiometry of each reactant as it enters the mixing region where synthesis occurs. It also facilitates the introduction of seed particles (e.g. nanoscale SiC) to dramatically enhance the rate of the synthesis reaction compared to gas-phase synthesis in rf plasma reported by Canfield and others. During the Phase 1 effort ATC commissioned its 60 kW 5 MHz rf source for a manufactur-ing-scale rf plasma torch. This effort required repair of numerous elements, integration of cooling and input circuits, and tuning of the load characteristics. The effort was successful, and the source has now been tested to ~full power. Also in the Phase 1 effort we encountered a subsidiary but very important problem: the world is running out of the only present supply of phase-pure amorphous boron. The starting boron powder must be in the amorphous phase in order for the synthesis reaction to produce phase-pure MgB2. Even small contamination with crystalline boron results in the formation of parasitic phases such as MgB4, MgB7, etc. Such parasitic phases are a primary element of the connectivity problem, in which even though a sample powder may contain grains of high-quality MgB2, adjacent grains are surrounded by intergrowths of parasitic phases so that current trans-port is badly degraded. The best results to date have been obtained using boron powder produced long ago for a rocket propellant development project. The synthesis process was complex and is now largely lost, and the manufacturing equipment has long since been scrapped. The last batch of the powder has been used during recent years to support MgB2 R&D at several labs, but supplies are dwindling. ATC has identified a first application of its plasma torch to synthesize phase-pure amorphous boron flake using a rapid-quench splat technique. Inexpensive technical-grade boron would be purified of contaminants, then dispersed as an aerosol in inert gas and passed through the plasma torch to melt it into a spray. The spray would be splat-condensed on a rotating drum to form pure amorphous flake. The process would begin with technical-grade boron powder, having good stoichiometric purity, nanoscale particles, but significant contamination of MgO and crystalline boron. We used wet chemistry to remove B2O3 completely and reduced the MgO impurity, and analyzed the particle size distribution using a Coulter counter and the phase composition using X-ray diffrac-tion (XRD). The next step will be to build an rf plasma torch with a recirculating single-component aerosol feed and the cooled splat drum and collector, and undertake process devel-opment for amorphous boron powder. This revised goal has two benefits. First, it is an easier technology than our ultimate goal of a multi-component laminar flow torch. We have been counseled by those experienced in plasma torch technology that our ultimate goal will require a torch that should be feasible but has never been attempted. It may require an extended period of R&D for both the torch itself and the gas dynamics in the reaction region. Second, this simpler single-component process will yield a product powder that is important today for the many groups undertaking powder-metallurgy routes to MgB2. The above success and learning curve has brought us to a significant shift of strategy from what was originally set out in the Phase 1 plan. But this shift has brought us to within sight of a powder product that will itself be an enabling boost for the community of MgB2 developers.

25 ENERGY STORAGE↗

Axial mass fraction measurements in a 300kA dense plasma focus

The dynamics and characteristics of the plasma sheath during the axial phase in a ~300 kA, ~2 kJ dense plasma focus using a static gas load of Ne at 1–4 Torr are reported. The sheath, which is driven axially at a constant velocity ~10 5 m/s by the j × B force, is observed using optical imaging, to form an acute angle between the electrodes. This angle becomes more acute (more parallel to the axis) along the rundown. The average sheath thickness nearer the anode is 0.69 ± 0.02 mm and nearer the cathode is 0.95 ± 0.02 mm. The sheath total mass increases from 1 ± 0.02 μg to 6 ± 0.02 μg over the pressure range of 1–4 Torr. However, the mass fraction (defined as the sheath mass/total mass of cold gas between the electrodes) decreases from 7% to 5%. In addition, the steeper the plasma sheath, the more mass is lost from the sheath, which is consistent with radial and axial motion. Lastly, experimental results are compared to the Lee code when 100% of the current drives the axial and radial phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Damaged Fuel in the United States

Over the years of commercial nuclear power plant operations in the United States (U.S.), many fuel assemblies have lost the capability to perform all of their desired functions. These assemblies have lost the capability to be handled, stored, or transported to meet regulations resulting in them being classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in a damaged fuel can that will be used in conjunction with a storage and/or transportation system. The storage and transportation systems have a limit on how many slots can be filled with damaged fuel cans. A damaged fuel can is generally a stainless steel container that confines damaged SNF and is closed on its end by screened openings. These screened openings allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of an abundance of caution a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S., because the regulations for storage and transport do not specify exactly how to classify damaged fuel. Instead the regulations license/certify packages that specify approved contents. Damaged fuel must be included in the approved contents to be a viable option. In many cases damaged SNF is encapsulated in a damaged fuel can to ensure it can confine gross fuel particles, debris, and or damaged assemblies to a known volume within a loaded cask. This damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation design system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was performed by the U.S. Energy Information Administration (EIA) and used data from U.S. reactors concluding in June 30th 2013 to produce Form GC-859, “Nuclear Fuel Data Survey”. Based on this form there were 136,821 boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies for a total of 241,468 SNF assemblies in the U.S. Out of these 241,468 SNF assemblies, 4,521 assemblies were classified as failed. Some assemblies were also disassembled and the fuel rods or pieces of fuel rods were combined together to make a consolidated assembly. A consolidated assembly may include damaged fuel, or it could have been consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing between 0 and 264 whole fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in a damaged fuel can. In addition to the consolidated assemblies, 2,391 uncanistered fuel rod pieces exist, which were removed from 494 assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Induction Linac Pulsers

The pulsers used in most of the induction linacs evolved from the very large body of work that was done in the U.S. and Great Britain during the development of the pulsed magnetron for radar. The radar modulators started at {approx}100 kW and reached >10 MW by 1945. A typical pulse length was 1 {mu}s at a repetition rate of 1,000 pps. A very comprehensive account of the modulator development is Pulse Generators by Lebacqz and Glasoe, one of the Radiation Laboratory Series. There are many permutations of possible modulators, two of the choices being tube type and line type. In earlier notes I wrote that technically the vacuum tube pulser met all of our induction linac needs, in the sense that a number of tubes, in series and parallel if required, could produce our pulses, regulate their voltage, be useable in feed-forward correctors, and provide a low source impedance. At a lower speed, an FET array is similar, and we have obtained and tested a large array capable of >10 MW switching. A modulator with an electronically controlled output only needs a capacitor for energy storage and in a switched mode can transfer the energy from the capacitor to the load at high efficiency. Driving a full size Astron induction core and a simulated resistive 'beam load' we achieved >50% efficiency. These electronically controlled output pulses can produce the pulses we desire but are not used because of their high cost. The second choice, the line type pulser, visually comprises a closing switch and a distributed or a lumped element transmission line. The typical switch cannot open or stop conducting after the desired pulse has been produced, and consequently all of the initially stored energy is dissipated. This approximately halves the efficiency, and the original cost estimating program LIACEP used this factor of two, even though our circuits are usually worse, and even though our inveterate optimists often omit it. The 'missing' energy is that which is reflected back into the line from mismatches, the energy left in the accelerator module's capacitance, the energy lost in the switch during switching and during the pulse, and the energy lost in the pulse line charging circuit. For example, a simple resistor-limited power supply dissipates as much energy as it delivers to the pulse forming line, giving a factor if two by itself, therefore efficiency requires a more complicated charging system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aging Processes of Silver Mordenite and Silver Functionalized Aerogel in Dry Air, Humid Air and NO/N{sub 2}

One major problem in the treatment of nuclear-fuel reprocessing off-gas streams is the loss of capacity of the adsorbents exposed to off-gas streams containing air, I{sub 2} vapor, H{sub 2}O vapor, NO and NO{sub 2} over extended periods of time. These aging processes decrease the adsorption capacity of the reduced silver exchanged mordenite (Ag{sup 0}Z) and silver functionalized silica aerogel (Ag{sup 0}-aerogel) columns during the long processing time of iodine adsorption. Significant work has been performed over the past few years at ORNL on Ag{sup 0}Z and Ag{sup 0}-aerogel aging. The Ag{sup 0}Z and Ag{sup 0}-aerogel were aged in 4 different gas streams at 150 deg. C for periods of time up to 6 months. The aging samples were then loaded with I{sub 2} to determine the capacity loss after the aging. The results are summaries in Tab. 1. It was found that both Ag{sup 0}Z and Ag{sup 0}-aerogel had different amounts of capacity loss in different gases. For example, 40% and 22% capacity loss were observed for Ag{sup 0}Z and Ag{sup 0}-aerogel when aged in dry air for 6 months, while 78% and 43% capacity loss were observed when aged in 1% NO{sub 1} for 2 months. In addition, it was found that Ag{sup 0}Z and Ag{sup 0}-aerogel had a different capacity loss when aged at the same conditions. For example, after aged in 2% NO{sub 2} for 2 months, Ag{sup 0}Z lost 30% iodine capacity, but there was no capacity loss for Ag{sup 0}- aerogel. The differences in capacity loss should be due to different aging processes occurred when Ag{sup 0}Z and Ag{sup 0}- aerogel were exposed to different gases. The mechanisms of the aging processes have not been determined and need to be studied with proper chemical and physical characterization methods. Towards this objective, experimental work is proposed and on-going to obtain data to determine the mechanisms of the aging processes of Ag{sup 0}Z and Ag{sup 0}-aerogel in different aging gas streams. In addition, models will be developed to describe the deactivation process of the adsorbents when exposed to off gases. The deactivation model will be included in the transport models for predicting the adsorption processes over these long-time periods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Damaged Fuel in the United States - 20325

Throughout the history of commercial nuclear power plant operations in the U.S., many fuel assemblies have lost the capability to perform all of their desired functions. Since they can no longer be handled, stored, or transported in accordance with established regulations, they are classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in damaged fuel cans to be used in conjunction with storage and/or transportation systems. These systems have a limited number of slots that can be filled with damaged fuel cans. A damaged fuel can is generally a stainless-steel container that confines damaged spent nuclear fuel (SNF) and is closed at one end by mesh endpoints that allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of extreme caution, a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S. because relevant regulations do not specify exactly how to classify damaged fuel. Instead, these regulations license/certify packages that specify approved contents. Damaged fuel must be included among the approved contents to be considered acceptable. In many cases, damaged SNF is encapsulated in damaged fuel cans to ensure it can confine gross fuel particles, debris, and/or damaged assemblies to known volumes within loaded casks. A damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was published by the U.S. Energy Information Administration (EIA), which used data from U.S. reactors compiled from 1968 to June 30, 2013, to produce Form GC-859, 'Nuclear Fuel Data Survey.' According to this form, there were 136,821 boiling water reactor (BWR) SNF assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies, for a combined total of 241,468. Of these, 4,521 were classified as failed. Some were also disassembled and the fuel rods or pieces of fuel rods combined to make consolidated assemblies. These consolidated assemblies may include damaged fuel or were perhaps consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing 0 - 264 entire fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in each damaged fuel can. In addition to the consolidated assemblies, 2,391 un-canistered fuel rod pieces exist, which were removed from 494 assemblies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Delamination failure in a unidirectional curved composite laminate

Delamination failure in a unidirectional curved composite laminate was investigated. The curved laminate failed unstably by delaminations developing around the curved region of the laminate at different depths through the thickness until virtually all bending stiffness was lost. Delamination was assumed to initiate at the location of the highest radial stress in the curved region. A closed form curved beam elasticity solution and a 2D finite element analysis (FEA) were conducted to determine this location. The variation in the strain energy release rate, G, with delamination growth was then determined using the FEA. A strength-based failure criteria adequately predicted the interlaminar tension failure which caused initial delamination onset. Using the G analysis the delamination was predicted to extend into the arm and leg of the laminate, predominantly in mode I. As the initial delamination grew around the curved region, the maximum radial stress in the newly formed inner sublaminate increased to a level sufficient to cause a new delamination to initiate in the sublaminate with no increase in applied load. This failure progression was observed experimentally.

Martin, Roderick H.↗

Delamination failure in a unidirectional curved composite laminate

Delamination failure in a unidirectional curved composite laminate was investigated. The curved laminate failed unstably by delaminations developing around the curved region of the laminate at different depths through the thickness until virtually all bending stiffness was lost. Delamination was assumed to initiate at the location of the highest radial stress in the curved region. A closed form curved beam elasticity solution and a 2-D finite element analysis (FEA) were conducted to determine this location. The variation in the strain energy release rate, G, with delamination growth was then determined using the FEA. A strength-based failure criteria adequately predicted the interlaminar tension failure which caused initial delamination onset. Using the G analysis the delamination was predicted to extend into the arm and leg of the laminate, predominantly in mode I. As the initial delamination grew arould the curved region, the maximum radial stress in the newly formed inner sublaminate increased to a level sufficient to cause a new delamination to initiate in the sublaminate with no increase in applied load. This failure progression was observed experimentally.

Martin, Roderick H.↗

Complete Initial Scoping Tests on the Incorporation of Novel Loaded Iodine Getters into GCM

This study encompasses initial scoping tests on the incorporation of a novel iodine loaded getter material into the Sandia developed low temperature sintering glass ceramic material (GCM) waste form. In particular, we studied the PNNL Ag-I-Aerogel. Optical microscopy indicates inhomogenous samples based on particle sizes and variations in color (AgI vs Ag/AgO on silica). TGA/MS data when heated in air indicates loss of iodine and organics (CO2) between 250-450°C a total of ~15wt% loss, with additional / small iodine loss when during 550°C hold for 1 hr. TGA/MS data when heated in N2 indicates less organic and slightly less iodine loss below 550°C, with no loss of iodine in 550°C 1 hour hold. Furthermore, a substantial mass loss of sulfur containing compounds is observed (m/e of 34 and 36) between 150 – 550°C in both air and N2 sintering atmospheres. In an effort to capture iodine lost to volatilization during heating (at temps below glass sintering temperature of 550°C), we added 5 wt% Ag flake to the AgIaerogel. Resulting data indicates the iodine is retained with the addition of the Ag flake, resulting in only a small iodine loss (< 1wt%) at ~350°C. No method of curtailing loss of sulfur containing compounds due to heating was successful in this scoping study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of gravitoinertial force on ocular counterrolling.

The effect of G loading on the magnitude of ocular counterrolling at various angles of tilt up to 63 deg. was measured on normal subjects and compared with the effect on persons with severe or complete loss of vestibular function. The group of six normal subjects manifested a compensatory eye roll which increased as a direct and essentially linear function of the component of the gravitoinertial force acting laterally on the subject. This increase in response was not observed in the five deaf subjects with severe or complete bilateral loss of their vestibular organs. These findings confirmed similar results found by other authors using other measuring techniques which show that the reflex eye movement is dependent on and limited to the magnitude of the gravitoinertial stimulus (within the range used) when the otolithocular system is functioning normally. However when this function is severely impaired or lost, the magnitude of the compensatory eye roll is limited to that manifested at 1 G and possibly to nonotolithic contributions. These findings offer means for differentiation between otolithic-defective and ?normal' persons who exhibit little counterrolling.

Miller, E. F., II↗

Low-temperature carbon monoxide oxidation catalysed by regenerable atomically dispersed palladium on alumina

Catalysis by single isolated atoms of precious metals has attracted much recent interest since it promises the ultimate economy in atom efficiency. Previous reports have been confined to reducible oxide supports such as FeO x , TiO₂ or CeO₂. Here we show that isolated Pd atoms can be stabilized on industrially relevant gamma-alumina supports. At low Pd loadings (≤0.5 wt%) these catalysts contain exclusively atomically dispersed Pd species. The addition of lanthanum-oxide to the alumina, long known for its ability to improve alumina stability, is found to also help in the stabilization of isolated Pd atoms. Aberration-corrected scanning transmission electron microscopy (AC-STEM) confirms the presence of intermingled Pd and La on the gamma-alumina surface. Operando X-ray absorption spectroscopy, performed on Pd/La-alumina and Pd/gamma-alumina (0.5 wt% Pd) demonstrates the presence of catalytically active atomically dispersed ionic Pd in the Pd/La-doped gamma-alumina system. CO oxidation reactivity measurements show onset of catalytic activity at 40 °C, indicating that the ionic Pd species are not poisoned by CO. The reaction order in CO and O₂ is positive, suggesting a reaction mechanism that is different from that on metallic Pd. The catalyst activity is lost if the Pd species are reduced to their metallic form, but the activity can be regenerated by oxidation at 700 °C in air. The high-temperature stability of these ionic Pd species on commercial alumina supports makes this catalyst system of potential interest for low-temperature exhaust treatment catalysts.

Environmental Molecular Sciences Laboratory↗