Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Propulsion challenges and opportunities for high-speed transport aircraft

For several years there was a growing interest in the subject of efficient sustained supersonic cruise technology applied to a high-speed transport aircraft. The major challenges confronting the propulsion community for supersonic transport (SST) applications are identified. Both past progress and future opportunities are discussed in relation to perceived technology shortfalls for an economically successful SST that satisfies environmental constraints. A very large improvement in propulsion system efficiency is needed both at supersonic and subsonic cruise conditions. Toward that end, several advanced engine concepts are being considered that, together with advanced discipline and component technologies, promise at least 40 percent better efficiency that the Concorde engine. The quest for higher productivity through higher speed is also thwarted by the lack of a conventional, low-priced fuel that is thermally stable at the higher temperatures associated with faster flight. Airport noise remains a tough challenge because previously researched concepts fall short of achieving FAR 36 Stage 3 noise levels. Innovative solutions may be necessary to reach acceptably low noise. While the technical challenges are indeed formidable, it is reasonable to assume that the current shortfalls in fuel economy and noise can be overcome through an aggressive propulsion research program.

Strack, William C.↗

Rosat observations of FK comae berenices

We obtained ROSAT PSPC observations of FK Com over a period of 24.4 h, or 0.42 rotation. During the observations the x-ray flux increased by a factor of at least 5 before declining toward its previous level. A single temperature Raymond-Smith model is adequate to model the low signal-to-noise ratio spectrum from each observation interval. Initially the spectrum was that of a 8.5 x 10(exp 6) K plasma, with L9sub x)=0.66 x 10(exp 31) erg s(exp -1). When the x-ray flux was greatest, the model plasma temperature rose to 2.5 x 10(exp 7) K, and L(sub x)=3.46 x 10(exp 31) ergs(exp -1). During the post-maximum decline in luminosity the plasma temperature was approximately 12 x 10(exp 6) K. We conclude that the increase of x-ray flux recorded by ROSAT was due to an x-ray flare with a 1.5 h decline time scale.

Welty, Alan D.↗

A technique for computation of noise temperature due to a beam waveguide shroud

Direct analytical computation of the noise temperature of real beam waveguide (BWG) systems, including all mirrors and the surrounding shroud, is an extremely complex problem and virtually impossible to achieve. Yet the DSN antennas are required to be ultra low-noise in order to be effective, and a reasonably accurate prediction is essential. This article presents a relatively simple technique to compute a real BWG system noise temperature by combining analytical techniques with data from experimental tests. Specific expressions and parameters for X-band (8.45-GHz) BWG noise computation are obtained for DSS 13 and DSS 24, now under construction. These expressions are also valid for various conditions of the BWG feed systems, including horn sizes and positions, and mirror sizes, curvatures, and positions. Parameters for S- and Ka-bands (2.3 and 32.0 GHz) have not been determined; however, those can be obtained following the same procedure as for X-band.

Veruttipong, W.↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conversion gain and noise of niobium superconducting hot-electron-mixers

A study has been done of microwave mixing at 20 GHz using the nonlinear (power dependent) resistance of thin niobium strips in the resistive state. Our experiments give evidence that electron-heating is the main cause of the nonlinear phenomenon. Also a detailed phenomenological theory for the determination of conversion properties is presented. This theory is capable of predicting the frequency-conversion loss rather accurately for arbitrary bias by examining the I-V-characteristic. Knowing the electron temperature relaxation time, and using parameters derived from the I-V-characteristic also allows us to predict the -3 dB IF bandwidth. Experimental results are in excellent agreement with the theoretical predictions. The requirements on the mode of operation and on the film parameters for minimizing the conversion loss (and even achieving conversion gain) are discussed in some detail. Our measurements demonstrate an intrinsic conversion loss as low as 1 dB. The maximum IF frequency defined for -3 dB drop in conversion gain, is about 80 MHz. Noise measurements indicate a device output noise temperature of about 50 K and SSB mixer noise temperature below 250 K. This type of mixer is considered very promising for use in low-noise heterodyne receivers at THz frequencies.

CONVERSION GAIN↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic probe for low-noise, high-frequency electronic measurements

The design and performance of a low-noise, modular cryogenic probe, which is applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields, is presented. The design of the probe facilitates the exchange of sample holders and sample-stage amplifiers, which, combined with its characteristic low transmission and reflection loss, make this design suitable for high precision or low sensitivity measurements. The specific example of measuring the shot noise of magnetic tunnel junctions is discussed. We highlight various design characteristics chosen specifically to expand the applicability of the probe to measurement techniques such as nuclear magnetic resonance.

47 OTHER INSTRUMENTATION↗

Nimbus-earth radiation budget sensor characterization for improved data reduction fidelity

Detailed characterizations of flight spare earth flux sensors from the Nimbus Earth Radiation Budget (ERB) program have been performed which, when coupled with a more careful accounting of the orbital instrument environment, provide the potential for improved accuracy in the final data products. The characterizations included detailed field-of-view mappings, responses to transient long and short wavelength radiation, and response to sensor temperature changes. These sensor and environment characterizations, along with the outstanding low noise and stability properties of the ERB instrument signal processing system, promise improvement of the data accuracy to levels sufficient for long-term budget and climatological purposes. The combined data sets from Nimbus 6 and 7 are expected to span a period in excess of 10 years. The improvements in data accuracy are particularly significant over zonal latitude bands because the corrections are strongly latitude dependent.

Maschhoff, R.↗

Non-linearity in measurement systems: Evaluation method and application to microwave radiometers

A simple method for determination and correction of nonlinaearity in measurement systems is presented. The technique is applicable to a wide range of measuring systems. The basic concept, an analysis, and a sample application are given. Nonlinearity of the Goldstone DSS 13 low noise HEMT 2.3 GHz (S-band) radiometer system results in noise temperature measurement errors. These errors are successfully correct with this method.

Stelzried, C. T.↗

Infrared ground-based astronomy with the Hughes 256 X 256 PtSi array

It is shown that large format PtSi Schottky diode infrared arrays, the Hughes 256 X 256 hybrid Schottky array in particular, are competitive alternatives to the smaller format photovoltaic arrays for ground-based astronomy. The modest quantum efficiency of the PtSi compared to the photovoltaic devices is more than compensated for by the larger format. The use of hybrid technology yields effective fill factors of nearly 100 percent, and the low dark current, noise, excellent imaging characteristics, cost, and solid nitrogen operating temperature add to the effectiveness of this array for ground-based imaging. In addition to discussing the characteristics of this array, researchers present laboratory test data and astronomical results achieved at Kitt Peak.

Fowler, A.↗

Metglas 2714A for Low Temperature Transformer Core and EMI Filter

We have measured the real and imaginary parts of the relative permeability of Metglas 2714A. The magnetization noise density of a toroid made of this material is also measured with a SQUID magnetometer. This noise density is found to agree very well with the fluctuation dissipation theorem, implying that superconducting transformers with predictable noise characteristic can be designed. We also find that the relative permeability is larger than 10,000 at liquid helium temperature and at frequencies from DC to 100 kHz, making it suitable to be used as EMI filter material. Its usage should be similar to that of ferrites, with the exception that it is also effective at low temperatures.

Quach, Hung↗

A low temperature gravitational radiation detector

The beginning design of an experiment is discussed for studying gravitational radiation by using massive detectors which are cooled to ultralow temperatures in order to improve the signal to noise ratios and the effective range and stability of the detectors. The gravitational detector, a low detection system, a cooled detector, magnetic support, superconducting shielding, and superconducting accelerometer detector are described.

Hamilton, W. O.↗

Hemispherical variance anomaly and reionization optical depth

ABSTRACT Cosmic microwave background (CMB) full-sky temperature data show a hemispherical asymmetry in power nearly aligned with the Ecliptic, with the Northern hemisphere displaying an anomalously low variance, while the Southern hemisphere appears consistent with expectations from the best-fitting theory, Lambda Cold Dark Matter (ΛCDM). The low signal-to-noise ratio in current polarization data prevents a similar comparison. Polarization realizations constrained by temperature data show that in ΛCDM the lack of variance is not expected to be present in polarization data. Therefore, a natural way of testing whether the temperature result is a fluke is to measure the variance of CMB polarization components. In anticipation of future CMB experiments that will allow for high-precision large-scale polarization measurements, we study how the variance of polarization depends on ΛCDM-parameter uncertainties by forecasting polarization maps with Planck’s Markov chain Monte Carlo chains. We show that polarization variance is sensitive to present uncertainties in cosmological parameters, mainly due to current poor constraints on the reionization optical depth τ, which drives variance at low multipoles. We demonstrate how the improvement in the τ measurement seen between Planck’s two latest data releases results in a tighter constraint on polarization variance expectations. Finally, we consider even smaller uncertainties on τ and how more precise measurements of τ can drive the expectation for polarization variance in a hemisphere close to that of the cosmic-variance-limited distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of Understanding for Gear Materials

Today's gear designer has a large selection of possible gear materials to choose from. The choice of which material to use should be based on the requirements of the application and will include the operating conditions of load, speed, and temperature in addition to reliability, weight, noise limitation, accuracy, and cost. The plastic materials are generally low in cost with low strength capabilities and are suitable for many light-duty applications. Die-cast alloy and sintered powder-metal gears are also fairly inexpensive and will operate at higher loads and temperatures than plastic gears. The three types of cast iron offer a medium-strength gear at a cost that varies with the accuracy of machining requirements. Gears can be manufactured from several aluminum alloys for lightweight and medium cost and may be anodized for improved load capacity. The copper alloys, bronze and brass, are more costly but have good sliding and wear properties that are useful for worm gear applications. The hot-forged powder-metal gears have the advantage of medium cost with good accuracy and high strength. Several low- to medium alloy steels are available for gear design and most can be heat treated for added strength. The medium-alloy gear materials offer high strength when case hardened and will satisfy most high-load medium-temperature applications. For more severe load, speed, and temperature requirements the advanced high temperature alloys must be used. These include EX-53, CBS 600, Vasco X-2, Super Nitralloy (5Ni-2Al), and forged AISI M-50. As the requirements become more stringent, the cost will also increase. It is necessary that the gear designer have a working knowledge of the various gear materials in order to match the most economical material with the design requirements.

Dennis P Townsend↗

A Search for FeH in Hot-Jupiter Atmospheres with High-dispersion Spectroscopy

Most of the molecules detected thus far in exoplanet atmospheres, such as water and CO, are present for a large range of pressures and temperatures. In contrast, metal hydrides exist in much more specific regimes of parameter space, and so can be used as probes of atmospheric conditions. Iron hydride (FeH) is a dominant source of opacity in low-mass stars and brown dwarfs, and evidence for its existence in exoplanets has recently been observed at low resolution. We performed a systematic search of archival CARMENES near-infrared data for signatures of FeH during transits of 12 exoplanets. These planets span a large range of equilibrium temperatures (600 ≲ T eq ≲ 4000 K) and surface gravities (2.5 ≲ logg ≲ 3.5). We did not find a statistically significant FeH signal in any of the atmospheres, but obtained potential low-confidence signals (signal-to-noise ratio ~ 3) in two planets, WASP-33b and MASCARA-2b. Previous modeling of exoplanet atmospheres indicate that the highest volume mixing ratios (VMRs) of 10 -7 to 10 -9 are expected for temperatures between 1800 and 3000 K and log g≳3. The two planets for which we find low-confidence signals are in the regime where strong FeH absorption is expected. We performed injection and recovery tests for each planet and determined that FeH would be detected in every planet for VMRs ≫10 -6 , and could be detected in some planets for VMRs as low as 10 -9.5 . Additional observations are necessary to conclusively detect FeH and assess its role in the temperature structures of hot-Jupiter atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗