Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Quantum Sensing and Imaging of Spin–Orbit-Torque-Driven Spin Dynamics in the Non-Collinear Antiferromagnet Mn 3 Sn

Novel non-collinear antiferromagnets with spontaneous time-reversal symmetry breaking, non-trivial band topology, and unconventional transport properties have received immense research interest over the past decade due to their rich physics and enormous promise in technological applications. One of the central focuses in this emerging field is exploring the relationship between the microscopic magnetic structure and exotic material properties. Nanoscale imaging of both spin–orbit-torque-induced deterministic magnetic switching and chiral spin rotation in non-collinear antiferromagnet Mn 3 Sn films using nitrogen-vacancy (NV) centers are reported. Direct evidence of the off-resonance dipole–dipole coupling between the spin dynamics in Mn 3 Sn and proximate NV centers is also demonstrated by NV relaxometry measurements. These results demonstrate the unique capabilities of NV centers in accessing the local information of the magnetic order and dynamics in these emergent quantum materials and suggest new opportunities for investigating the interplay between topology and magnetism in a broad range of topological magnets.

36 MATERIALS SCIENCE↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

Dual-scale folding in cutting of commercially pure aluminum alloys

We examine a, hitherto, little-studied and curious machining chip morphology, with tell-tale signs of folding at two different length scales, that is common in cutting of certain ductile and highly strain-hardening metals like soft aluminum alloys, tantalum and niobium. This chip morphology does not appear in the usual catalogues of common chip types. The mechanics of formation of the “dual-scale folded chip” is studied in model material systems of commercially pure aluminum alloys (AA 1100 and AA 8040), that prominently exhibit this chip morphology. The flow, folding and associated plastic instabilities are investigated using micro/macro structure observations of the chip in a plane-strain cutting framework, with high-speed in situ imaging and image analysis of material flow; and force measurements. The smaller-scale folding is shown to develop in the primary deformation zone while the larger-scale folding occurs as the chip traverses the rake face of the tool. The resulting chip is composed of irregularly-spaced large folds, superimposed onto which are the quasi periodic small folds. The representative wavelengths of the two folds differ on average by an order of magnitude, 0.1 mm vs. 2 mm. The observations reveal a direct coupling between the material flow and chip morphology, and how specific attributes of the dual-scale folded chip arise from the flow mechanism. Plastic buckling is found to play a key role in the folding at both length scales. The small-scale folds are characteristic of a sinuous plastic flow mode, while the large-scale folding is characterized by buckling and stick-slip along the tool rake face, triggered by adhesive pinning of the chip to the tool. Important consequences of the dualscale folding are very large cutting forces, and force oscillations of large amplitude, despite the alloys being very soft, only ~ 25 HV. Here, the dual-scale folding is why many of these alloys are classified as “gummy” to machine. Since the dual-scale folded chip is associated with large cutting forces and poor surface quality, there is much to be gained by disrupting this flow type in practical machining applications. Methods for controlling the folding to improve machining performance with the gummy alloys are briefly discussed.

36 MATERIALS SCIENCE↗

Convolutional Neural Network for Segmenting Micro-X-ray Computed Tomography Images of Wood Cellular Structures

To further enhance the performance of wood products, improved tools are needed to study in situ cellular scale phenomena like mechanical deformations and moisture swelling. Micro-X-ray computed tomography (μXCT) using brilliant synchrotron light sources now has the spatial and temporal resolution for real-time visualization of phenomena in three-dimensional cellular structures. However, the tradeoff for speed includes the loss of intensity contrast between different types of materials within the imaged structure, such as cell wall and air in wood. This loss of contrast prevents traditional histogram-based segmentation methods from being used effectively. A new convolutional neural network (CNN) approach was therefore developed to segment fast μXCT images of wood into cell wall and air volumes. The fast μXCT and segmentation were demonstrated in the study of moisture swelling in loblolly pine (Pinus taeda) earlywood and latewood cellular structures conditioned at 0%, 33%, 75%, and 95% relative humidity (RH). The CNN segmentation results had a mean intersection over union (IoU) metric accuracy of 96%. Initial analysis of the swelling in the latewood revealed cell walls swelled about 25% when conditioned from 0% to 95% RH. Additionally, the widths of ray cell lumina in the transverse plane of latewood could be observed to increase at higher RH. The segmentation method presented here will facilitate future quantitative analyses in in situ μXCT studies of wood and other similar cellular materials.

Arzola-Villegas, Xavier (ORCID:0000000305369766)↗

Resolution-enhanced X-ray fluorescence microscopy via deep residual networks

Abstract Multimodal hard X-ray scanning probe microscopy has been extensively used to study functional materials providing multiple contrast mechanisms. For instance, combining ptychography with X-ray fluorescence (XRF) microscopy reveals structural and chemical properties simultaneously. While ptychography can achieve diffraction-limited spatial resolution, the resolution of XRF is limited by the X-ray probe size. Here, we develop a machine learning (ML) model to overcome this problem by decoupling the impact of the X-ray probe from the XRF signal. The enhanced spatial resolution was observed for both simulated and experimental XRF data, showing superior performance over the state-of-the-art scanning XRF method with different nano-sized X-ray probes. Enhanced spatial resolutions were also observed for the accompanying XRF tomography reconstructions. Using this probe profile deconvolution with the proposed ML solution to enhance the spatial resolution of XRF microscopy will be broadly applicable across both functional materials and biological imaging with XRF and other related application areas.

36 MATERIALS SCIENCE↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Geometrically stabilized skyrmionic vortex in FeGe tetrahedral nanoparticles

The concept of topology has dramatically expanded the research landscape of magnetism, leading to the discovery of numerous magnetic textures with intriguing topological properties. A magnetic skyrmion is an emergent topological magnetic texture with a string-like structure in three dimensions and a disk-like structure in one and two dimensions. Skyrmions in zero dimensions have remained elusive due to challenges from many competing orders. Here, by combining electron holography and micromagnetic simulations, we uncover the real-space magnetic configurations of a skyrmionic vortex structure confined in a B20-type FeGe tetrahedral nanoparticle. An isolated skyrmionic vortex forms at the ground state and this texture shows excellent robustness against temperature without applying a magnetic field. Furthermore, our findings shed light on zero-dimensional geometrical confinement as a route to engineer and manipulate individual skyrmionic metastructures.

36 MATERIALS SCIENCE↗

Neutron imaging of hydrogenous gases in porous-carbon materials around phase transitions

Focus herein is on hydrogenous gases interacting with porous-carbon materials on activated biochar at pressures ranging from 0 to 100 bar and temperatures from room (ambient) to cryogenic. Neutron radiography was conducted using a custom-made cell system to simultaneously image pure gas and gas interacting with the porous carbon. From neutron attenuation, the cross sections of methane and ethane and number concentrations were determined for different pressures and temperatures and compared with corresponding reference data. Sorption properties of the porous materials were investigated in situ with methane, ethane, and propane.

Ossler, Frederik [Lund University, Sweden]↗

Mapping Competitive Reduction upon Charging in LiNi 0.8 Co 0.15 Al 0.05 O 2 Primary Particles

Side reactions involving surface reduction play a critical role in the failure of LiNi 0.8 Co 0.15 Al 0.05 O 2 to reach its theoretical capacity as a cathode material for Li-ion batteries. While macroscopic consequences are known, the underlying nanoscopic mechanisms are not fully elucidated. By coupling X-ray spectroscopy with several X-ray microscopy modalities, we have spatially resolved the extent of Ni oxidation at several states of charge and uncovered heterogeneity that is hidden when considering ensemble measurements alone. The use of morphologically controlled particles enabled high-resolution imaging of these materials, uncovering gradients of Ni oxidation states within individual primary particles. At high states of charge, these gradients revealed regions of possible oxygen deficiency extending deeper into the particle than previously observed. Surface-sensitive X-ray coupled scanning tunneling microscopy allows oxidation states to be measured at the material's surface, showing predominantly Ni II in the first atomic layer and mixtures of Ni II with Ni III /Ni IV already appearing 1.5 nm into the particle. These results reveal the subtle interplay between irreversible surface transformations and the bulk reactions that ultimately define function, which will refine strategies of surface passivation that are key to overcoming current performance limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Experiments of Local Non–Linear Behavior in Ferroelectric Materials

An automated experiment in multimodal imaging to probe structural, chemical, and functional behaviors in complex materials and elucidate the dominant physical mechanisms that control device function is developed and implemented. Here, the emergence of non-linear electromechanical responses in piezoresponse force microscopy (PFM) is explored. Non-linear responses in PFM can originate from multiple mechanisms, including intrinsic material responses often controlled by domain structure, surface topography that affects the mechanical phenomena at the tip-surface junction, and the presence of surface contaminants. Using an automated experiment to probe the origins of non-linear behavior in ferroelectric lead titanate (PTO) and ferroelectric Al 0.93 B 0.07 N films, it is found that PTO shows asymmetric nonlinear behavior across a/c domain walls and a broadened high nonlinear response region around c/c domain walls. In contrast, for Al 0.93 B 0.07 N, well-poled regions show high linear piezoelectric responses, when paired with low non-linear responses regions that are multidomain show low linear responses and high nonlinear responses. It is shown that formulating dissimilar exploration strategies in deep kernel learning as alternative hypotheses allows for establishing the preponderant physical mechanisms behind the non-linear behaviors, suggesting that automated experiments can potentially discern between competing physical mechanisms. Furthermore, this technique can also be extended to electron, probe, and chemical imaging.

36 MATERIALS SCIENCE↗

Applications and Deployment of Neutron Scatter Cameras in Nuclear Safeguards Scenarios

Neutron scatter cameras (NSCs) are a type of directionally sensitive neutron detector that rely on two consecutive neutron scattering events to localize a source of neutrons. NSCs can be used to locate, image, and identify unknown neutron sources or verify the geometry and identity of known sources. Much technical progress has been made in improving NSC designs, but little literature exists exploring the full range of practical application of neutron scatter cameras. This paper seeks to identify scenarios related to nuclear security and non-proliferation where deployment of NSCs may be useful. These situations could include: limited searches for sources during cargo screening, counting nuclear warheads for treaty verification, verification of special nuclear material during inspections, imaging nuclear contamination, imaging nuclear reactor cores, searching for lost sources, and matching neutron images in shipper/receiver or inventory management scenarios. These scenarios are examined with respect to existing NSC designs and proposed designs in terms of usefulness and practicality of deployment when compared to currently used detection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗