Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical note: Optimizing the in situ cosmogenic 36 Cl extraction and measurement workflow for geologic applications

Abstract. In situ cosmogenic 36Cl analysis by accelerator mass spectrometry (AMS) is routinely employed to date Quaternary surfaces and assess rates of landscape evolution. However, standard laboratory preparation procedures for 36Cl dating require the addition of large amounts of isotopically enriched chlorine spike solution; these solutions are expensive and increasingly difficult to acquire from commercial sources. In addition, the typical workflow for 36Cl dating involves measuring both 35Cl/37Cl and 36Cl/Cl concurrently on the high-energy (post-accelerator) end of the AMS system, but 35Cl/37Cl determinations using this technique can be complicated by isotope fractionation and system memory during measurement. The traditional workflow also does not provide 36Cl extraction laboratories with the data needed to calculate native Cl concentrations in advance of 36Cl/Cl measurements. In light of these concerns, we present an improved workflow for extracting and measuring chlorine in geologic materials. Our initial step is to characterize 35Cl/37Cl on sample aliquots of up to ∼1 g prepared in Ag(Cl, Br) matrices, which greatly reduces the amount of isotopically enriched spike solution required to measure native Cl content in each sample. To avoid potential issues with isotope fractionation through the accelerator, 35Cl/37Cl is measured on the low-energy, pre-accelerator end of the AMS line. Then, for 36Cl/Cl measurements, we extract Cl as AgCl or Ag(Cl, Br) in analytical batches with a consistent total Cl load across all samples; this step is intended to minimize source memory effects during 36Cl/Cl measurements and allows the preparation of AMS standards that are customized to match known Cl contents in the samples. To assess the efficacy of this extraction and measurement workflow, we compare chlorine isotope ratio measurements on seven geologic samples prepared using standard procedures and the updated workflow. Measurements of 35Cl/37Cl and 36Cl/Cl are consistent between the two workflows, and 35Cl/37Cl values measured using our methods have considerably higher precision than those measured following standard protocols. The chemical preparation and measurement workflow presented here (1) reduces the amount of isotopically enriched chlorine spike used per rock sample by up to 95 %; (2) identifies rocks with high native Cl concentrations, which may be lower priority for 36Cl surface exposure dating, at an early stage of analysis; and (3) allows laboratory users to maintain control over the total chlorine content within and across analytical batches. These methods can be incorporated into existing laboratory and AMS protocols for 36Cl analyses and will increase the accessibility of 36Cl dating for geologic applications.

58 GEOSCIENCES↗

A software‐defined networks ‐based measurement method of network traffic for 6G technologies

Abstract In software‐defined networks (SDN) for 6G technologies, the controller should accurately and efficiently measure the flow traffic in switches for traffic engineering. Fine‐grained flow measurement can more accurately describe the traffic in the network, but it also consumes much more resources. To reduce the overhead incurred in the measurement process and obtain the approximate fine‐grained measurements, we propose a novel lightweight measurement scheme that runs in the controller. The novel lightweight measurement architecture consists of two parts: coarse‐grained measurement and interpolation‐optimization. In the first part, based on the SDN architecture, we use the pull‐based random sampling method to quickly obtain the coarse‐grained measurement of flow traffic through OpenFlow protocol. In the second part, we insert some discrete values into the coarse‐grained measurement with the interpolation theory, then we optimize interpolation results until finding the optimal fine‐grained flow traffic measurement by utilizing the multiconstraint method. We verified the feasibility of the proposed measurement method, and simulation results show that the measurement error of the proposed method is under 25%, but the flow measurement overhead of this method occupies only 3.3% compared with that of the fine‐grained method.

Huo, Liuwei↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

The Impact of Increased Requirements for Verification Measurements of Category III and IV Receipts

As part of the regular nuclear material accounting and control process, sites that have accountable nuclear material regularly perform measurements of the material in their possession. The expectation for the type of measurements and their frequency is set out in Department of Energy (DOE) Order 474.2, and further detailed in each site’s respective material control and accountability (MC&A) plan and associated controlling documents. The measurements of interest in this report are those performed on external (between DOE sites) transfer receipts of Category III or IV accountable materials. In 2020, a revision of DOE Order 474.2 was proposed that would significantly increase the requirement that measurements be performed upon receipt of material, and further, that those measurements be quantitative verification (rather than qualitative confirmatory) measurements. A survey was performed of DOE sites to discuss the impact on their MC&A measurements program if more rigorous verification measurements requirements for Category III and IV receipts were implemented. An assessment of nondestructive assay (NDA) measurement instruments to meet those needs was also performed. Across the board, sites indicated that personnel and budget would cause the largest impact. Sites which are qualified as Category I/II indicated a reduced impact as these sites already have the measurement capabilities and some personnel but would require the acquisition of additional measurement systems. Category III/IV sites indicated a much larger impact as these sites generally have smaller MC&A programs. A few smaller sites stated a measurement program would need to be created to handle the demand. Calorimetry, quantitative gamma spectroscopy and neutron coincidence counting systems were identified as common systems that could meet the verification measurement requirements. The other, and perhaps larger issue is the need for calibration standards for the calorimetry and neutron coincidence counting systems. It is proposed that a comparative study be performed for ISOCS and ISOTOPICS, qualification of a COTS calorimetry system be performed, and development of an AWCC system that uses a neutron generator.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Snow ALbedo eVOlution (SALVO) Campaign Spectral Albedo and Related Measurements from April - June, 2024 in Utqiagivk, AK

A field-portable spectroradiometer, referred to herein as an ‘ASD’, was used to make spatially-distributed spectral albedo (350 – 2500 nm) measurements on tundra and sea ice surfaces. The ASD detector is carried in a backpack and controlled via a computer mounted on the front of the operator (see Figure 1). The ASD measures the spectral irradiance from a fiber optic cable that is routed from the backpack to a custom, gooseneck cosine collector mounted on the end of a 1-m long boom (Grenfell and Perovich, 2008). The boom was held at hip height (approximately 1 m) and had an integrated bubble level for levelling. To make an albedo measurement, first the operator collect an incident (down-welling) irradiance, followed by a reflected (up-welling) measurement. The time between incident and reflected measurements was typically between 11 and 26 seconds (interquartile range). For each measurement, 10 spectra are averaged together. Albedo is calculated as the ratio of the reflected to incident measurement, which obviates the need for absolute radiometric calibration. Albedo measurements were taken parallel to the 200-m albedo lines at 5-m increments (41 measurements) ~1 m south of the line. While the ASD operator was making measurements, an assistant kept notes on the scan number associated with each measurement, the surface type (see below), and collected photos of each measurement (see companion oblique photos data archive). Measurements were made within 3 hours of solar noon.

ASD Spectroradiometer↗

MESOSCALE THERMAL TRANSPORT MEASUREMENTS OF MULTI-PHASE AND POROUS NUCLEAR FUELS USING A SQUARE-WAVE PULSE THERMOREFLECTANCE TECHNIQUE

The safe and efficient operation of nuclear reactors require accurate knowledge of peak temperatures in the fuel assemblies. The temperature profiles are governed by the thermal transport properties of the fuel, namely the thermal conductivities (k) and thermal diffusivities (D). These values can be very difficult to measure as they are known to vary considerably from the measured bulk values of the fresh fuel, and quickly degrade with increasing burnup [1 -3] . Laser-based techniques have been effectively used for non-destructive and non-contact thermal transport measurements of a wide variety of materials, including nuclear materials [4-6] that would otherwise prove too hazardous or difficult to measure otherwise. In this study, a new thermoreflectance technique known as square-pulse transient thermoreflectance (SPTR) is described and used to determine the mesoscale thermal diffusivity of both uranium sesquisilicide (U3Si2) and uranium nitride (UN) phases in a composite fuel with micron level spatial resolution [7]. This technique employs a rapid train of square-wave pulses from an excitation laser to create a periodic heat flux on a gold coated sample surface. Surface adsorption results in transient film temperatures and hence rapid fluctuations in thermoreflectance that can be measured via a detection laser coupled with a digital oscilloscope. The lasers are coaxially focused on the sample surface, allowing for a sample measurement area of a single convolved laser spot size (~2 µm). A sensitivity analysis was conducted to identify key measurement parameters of this technique using reference materials with a range of thermal conductivities comparable to those of both ceramic, composite, and metal nuclear fuel types (1.4 – 27.2 W/m-K). The reference materials were measured using the new technique as well as a spatial-domain thermoreflectance technique (SDTR) previously reported for a comparison [8]. Additionally, measurements of several U3Si2 and UN phase regions of a polished UN/U3Si2 (70/30 vol.%) sample were taken, and the resulting calculated D values are reported, with both techniques showing excellent agreement between samples. This technique was used to scan a multiphase region at 5 micron increments to generate a local diffusivity map, demonstrating the utility of the techniques for measuring thermal transport properties in specimens with precipitates and secondary phases. Furthermore, the technique is currently being applied to measure thermal properties of Fast Flux Test Reactor (FFTR) irradiated metal fuel specimens whose porous microstructure make it very difficult to measure using other techniques. Comparison of the local scale measurements are compared with the pre-irradiated fuel samples to show the degradation of thermal transport in fuels due to pores from fission gas bubbles and other irradiation induced defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sodium Void Worth and Control Rod Worth Measurements in ZPPR 15

Sodium void worth and control rod worth were measured in Phases A, B, C and D of the ZPPR15 experimental program. Sodium voiding was simulated by replacing stainless steel cans containing sodium by empty stainless steel cans of the same sizes. The control rod worth measurements were measurements of simulated control rods (CRs) and simulated empty control rod positions (CRPs). A CRP consisted of a 2 x 2 array of drawers filled with sodium plates. A CR consisted of a 2 x 2 array of drawers containing alternating columns of boron carbide plates and sodium plates in the front 18 inches and just sodium plates in the back 18 inches. The ZPPR staff published the measured sodium void worths and control rod worths and the statistical uncertainties in the measured values. In reality, the published uncertainty for each of these measurements is only one component of the total uncertainty. There are additional contributions from uncertainties related to measurement technique, plate compositions and reproducibility. However, the dominant uncertainty for the sodium void worth and control rod worth measurements is the uncertainty in βeff which is required to convert from the natural measurement units, cents, to the calculation units, pcm or Δ/k 1 k 2 . A full uncertainty analysis was performed for the sodium void worth and control rod worth measurements. The significant uncertainties were quantified, and a total uncertainty was derived for each sodium void worth or control rod worth measurement. The ZPPR-15 experimental records were used to create detailed as-built Monte Carlo models of the sodium void worth and control rod worth configurations. These models were used to compute the sodium void worths and control rod worths. (C/E – 1) and the related uncertainty in (C/E – 1) were derived for the measured worths.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reaction Rate Distribution Measurements in ZPPR-15

Small metal foils were irradiated in ZPPR-15 to measure distributions for 239 Pu(n,f), 235 U(n,f), 238 U(n,f), 238 U(n,γ), 115 In(n,n’) and 115 In(n,γ) reaction rates in ZPPR-15. The measured data were reported as basic reaction rate distributions for individual foils, cell-averaged reaction rate distributions and spectral indices or reaction rate ratios. All of the measured data were analyzed and tabulated in such a manner that the data can be readily compared with computed values. The published uncertainties for ZPPR-15 the reaction rate measurements include the statistical uncertainties in the measurements, reproducibility uncertainty and small uncertainties related to corrections for items such as foil compositions and post-irradiation decay between reactor shutdown and foil measurement. There are additional uncertainty components related to detector calibration that are not included in the published uncertainties. A full uncertainty analysis was performed for each foil measurement and for quantities derived from the basic foil measurements. The significant uncertainties were quantified, and a total uncertainty was derived for each measured value. The ZPPR-15 experimental records were used to create detailed as-built Monte Carlo models for the foil reaction rate measurements in ZPPR-15 loadings 123, 134 and 203 and for the fission chamber measurements of 237 Np and 242 Pu fission rates in ZPPR-15 loading 141. Because there were many foils distributed in the ZPPR-15 assembly and because an individual foil occupies a negligible volume in the ZPPR-15 assembly, direct Monte Carlo calculations of the measured foil reaction rates would require an impractical computational effort. The as-built Monte Carlo models and related files were prepared for conversion to deterministic models that can be calculated with realistic computational effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: PM Modulair 1

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Quant-AQ MODULAIR. Mounted external to the instrument container, near the GCVI inlet. The MODULAIR™ air quality monitor uses the same patent-pending PM sensor found in the MODULAIR™-PM and adds four gas-phase measurements (CO, NO, NO2, and O3) to provide an all-in-one solution. Files data_10sec_Quant_Gas.csv, data_10min_Quant_Gas.csv Header: - CO[ppb]: Concentration of carbon monoxide (CO) measured at the time of sampling, expressed in parts per billion (ppb) - NO[ppb]: Concentration of nitric oxide (NO) measured at the time of sampling, expressed in parts per billion (ppb). - O3[ppb]: Concentration of ozone (O3) measured at the time of sampling, expressed in parts per billion (ppb). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. Files data_10sec_Quant_PM.csv, data_10min_Quant_PM.csv Header: - PM1[ug/m3]: Concentration of particulate matter with a diameter of 1 micron or less, measured in micrograms per cubic meter (µg/m³). - PM2-5[ug/m3]: Concentration of particulate matter with a diameter of 2.5 microns or less measured in micrograms per cubic meter (µg/m³). - PM10[ug/m3]: Concentration of particulate matter with a diameter of 10 microns or less, measured in micrograms per cubic meter (µg/m³). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage.

54 ENVIRONMENTAL SCIENCES↗

Charge exchange recombination spectroscopy measurements of DIII-D poloidal rotation with poloidal asymmetry in angular rotation

Sixteen new tangential views for the charge exchange recombination (CER) spectroscopy diagnostic at DIII-D were installed in 2019 on the high-field side (HFS) of the tokamak with the main goal being the measurement of main-ion (deuterium) poloidal rotation. Eight of the new views are connected to spectrometers, which view the main-ion spectrum, adding main-ion measurements where there were previously none, and another eight new views increased the spatial resolution of existing impurity (carbon) measurements on the HFS. When combined with the existing low-field side measurements, measurements at two locations on flux surfaces out to a normalized minor radius of ≈0.6 are possible. The new tangential views have been used to measure the deuterium poloidal rotation directly for the first time using the Poloidal Asymmetry in Angular Rotation (PAAR) method. Furthermore, these new measurements enable further testing of the validity of neoclassical poloidal rotation predictions. Separate measurements of the radial electric field can be made for an impurity ion and the main-ion by combining the PAAR measurements with additional CER measurements of toroidal rotation, temperature, and density. These independent measurements of the radial electric field agree reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗