Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

Flight Motor Set 360L003 (STS-29R)

The redesigned solid rocket motor (RSRM) flight set 360L003 was launched on March 13, 1989 as part of NASA space shuttle mission STS-29R. As was the case with flight sets 360L001 and 360L002 (STS-26R and STS-27R), both motors (360L003A and 360L003B) performed in an excellent manner. Evaluation of the ground environment instrumentation measurements verified thermal model analysis data and showed agreement with predicted environmental effects. The right-hand aft field joint primary heater failed during the countdown; the secondary heater was activated and performed as designed. All other field joint heaters and aft skirt thermal conditioning systems had no anomalies. Shuttle thermal imager infrared readings compared favorably with measured ground environment instrumentation data. No thermal launch commit criteria violations occurred at any time. Evaluation of the development flight instrumentation showed exceptional propulsion performance. All ballistic parameters closely matched the predicted values and were well within the required specification levels. Girth and biaxial strain gage measurements compared closely with corresponding gages on previous flight motors, static tests, and with preflight predictions. Adequate safety factors were verified. (Some ignition transient spiking was noted in a few girth gages; the spiking was determined not to be representative of actual case behavior, but an instrumentation phenomena.) The accelerometers again measured high vibration amplitude levels during the ignition transient and the reentry Max Q phases. Postflight inspection showed that all combustion gas was contained by the insulation in the field and case-to-nozzle joints. No anomalous insulation erosion patterns were found, and the seals that did directly contain motor pressure showed no heat effects, erosion, or blowby. All anomalies identified were a result of splashdown damage, with the exception of fretting in the case field joint interference (nonsealing) surfaces and a prelaunch field joint heater failure. The disposition of all anomalies and the complete results are reported.

Riehr, Glen A.↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A lidar instrument to measure H2O and aerosol profiles from the NASA ER-2 aircraft

Plans to develop the Lidar Atmospheric Sensing Experiment (LASE) instrument to conduct scientific experiments aboard a NASA U-2 (ER-2) aircraft are described. The LASE measurement objectives are listed, and the design of the LASE instrument is discussed, including performance criteria for the laser transmitter, wavemeter, telescope, optical receiver, and associated electronics. The instrument function is depicted with a block diagram, and layouts of various components are presented.

Vaughan, W. R.↗

System-Level Experimental Validations for Supersonic Commercial Transport Aircraft Entering Service in the 2018-2020 Time Period

This report describes the work conducted by The Boeing Company under American Recovery and Reinvestment Act (ARRA) and NASA funding to experimentally validate the conceptual design of a supersonic airliner feasible for entry into service in the 2018 to 2020 timeframe (NASA N+2 generation). The report discusses the design, analysis and development of a low-boom concept that meets aggressive sonic boom and performance goals for a cruise Mach number of 1.8. The design is achieved through integrated multidisciplinary optimization tools. The report also describes the detailed design and fabrication of both sonic boom and performance wind tunnel models of the low-boom concept. Additionally, a description of the detailed validation wind tunnel testing that was performed with the wind tunnel models is provided along with validation comparisons with pretest Computational Fluid Dynamics (CFD). Finally, the report describes the evaluation of existing NASA sonic boom pressure rail measurement instrumentation and a detailed description of new sonic boom measurement instrumentation that was constructed for the validation wind tunnel testing.

Magee, Todd E.↗

An instrument to measure the solar spectrum from 170 to 3200 nm on board Spacelab

This instrument, at the present time in development, will fly on board Spacelab I in May 1983. Other flights are foreseen during the following missions. The instrument is composed of three double monochromators covering the range 170 to 3200 nm. The spectrometers have bandpasses of 1 nm up to 900 nm and 20 nm from 850 to 3200 nm with an accuracy 1/100 nm. Calibration lamps are included in the instrument to monitor any change of its sensitivity and wavelength scale.

Thuiller, G.↗

Active-passive airborne ocean color measurement. I - Instrumentation

The instrumentation used in a multichannel lidar fluorosensor spectrometer functioning concurrently as a passive spectroradiometer for measuring upwelling ocean color radiance is discussed. The instrument calibration techniques are addressed, including the absolute passive calibration technique, the importance of relative channel-to-channel calibration for accurate ocean color measurement, and active mode calibration techniques using passive calibration transfer methods. Ground and flight test results from the dual-mode active-passive ocean color sensor are discussed.

Hoge, F. E.↗

A 2-lambda laser-induced flurorescence field instrument for ground-based and airborne measurements of atmospheric OH

A number of techniques have been proposed for detecting atmospheric OH radicals. Of these, the laser-induced fluorescence (LIF) technique has been used by the largest number of investigators. One of the problems arising in connection with the implementation of this technique is related to the perturbing effect of the UV (lambda approximately 282 nm) laser beam used for OH monitoring, while another problem relates to signal extraction. Several new LIF approaches have been or are currently under development with the objective to bring both problems under control. The present paper deals with the experimental features of one of these new approaches. The considered approach is referred to as 2-lambda laser-induced fluorescence (2-lambda LIF). It is shown that the 2-lambda LIF system provides significant advantages over earlier 1-lambda LIF OH measurement instruments operating at ambient pressure.

Rodgers, M. O.↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cross beam weather watch study

An optical cross beam correlation method has been proposed as a remote measuring system for atmospheric studies. Atmospheric measurements are limited due to the difficulty of placing measuring instruments at the desired location. Although meteorological towers and balloon flights are able to obtain wind data, they are greatly limited in their location. Thus, a real need exists for remote-sensing instrumentation in atmospheric measurements. Previous methods proposed to remotely sense atmospheric conditions include several types of microwave units, acoustic sounders, infrared sensors, optical sensors, and related laser techniques. The evaluation of a simple visible optical technique as a possible remote measuring system is discussed. A feasibility study of field tests of the instrumentation at meteorological sites is reported.

Sandborn, V. A.↗

Measuring the activity of BioBrick promoters using an in vivo reference standard

The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101) to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU) in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement conditions and instruments. Furthermore, these improvements are sufficient to begin to support the measurement of promoter activities across many laboratories. Additional in vivo reference standards for other types of biological functions would seem likely to have similar utility, and could thus improve research on the design, production, and reuse of standard biological parts.

59 BASIC BIOLOGICAL SCIENCES↗

Precise Measurement of Effective Focal Length

Computerized instrument measures effective focal lengths to 0.01 percent accuracy. Laser interferometers measure mirror angle and stage coordinate y in instrument for accurate measurment of focal properties of optical systems. Operates under computer control to measure effective focal length, focal surface shape, modulation transfer function, and astigmatism.

Wise, T. D.↗

Measurement technology: A compilation

Technical information is presented on measurement techniques and instruments, measurement applications for inspection activities, measurement sensors, and data conversion methods. Photographs or diagrams are included for each instrument or method described, and where applicable, patent information is given.

Source record↗

Instrumentation for measurements of solar irradiance and atmospheric optical properties

The Active Cavity Radiometer (ACR), an accurate absolute pyrheliometer, has been developed for measurements of total solar irradiance. It has been used to discover a -2.2% error in the International Pyrheliometric Scale and to make measurements in balloon flight experiments yielding a solar constant value of 136.6 (+ or - 0.7) mW/sq cm. New ACRs are being developed to monitor the total output of solar optical radiation in balloon, satellite and space shuttle experiments with long-term absolute uncertainty of + or - 0.1% or less. In a separate program, instrumentation for the measurement of the scattering and extinction of solar radiation by the atmosphere is being constructed to provide data for modeling atmospheric aerosol content. The aerosol models will facilitate computation of radiative transfer effects yielding quantitative net fluxes useful in evaluating the climatological impact of aerosols.

Willson, R. C.↗

Pressure instrumentation for gas turbine engines - A review of measurement technology

Many types and designs of pressure measuring instrumentation are used during the development and testing of gas turbine engines. This paper provides an overview of more commonly available pressure transducers and their characteristics. Probe designs for use in both steady-state and dynamic pressure measurement systems are reviewed. Techniques used to qualify instrument probes and the methods used to calibrate pressure transducers during engine testing are described.

Armentrout, E. C.↗