Search NASA⌕ Search

SEARCH · Search NASA

Results for “membrane reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Membrane Bioreactor Pretreatment of High-Salinity O&G Produced Water

Produced water (PW) from oil and gas production contains variable constituents that are difficult to remove with conventional treatment processes. The focus of this study was to explore the long-term performance of a membrane bioreactor (MBR) for the removal of organic constituents from PW and how performance and microbial community composition are affected by progressively increasing salinity and introduction of PW from different shale basins around the United States. Dissolved organic carbon removal from the PW remained consistent throughout the study, averaging 86% from the Denver-Julesburg basin PW and 66% removal from the Permian basin PW. Surfactant removal was less consistent, showing 87% removal of poly(ethylene glycols) (PEGs) at a total dissolved solid (TDS) concentration of 40 g/L but only 58% removal at a TDS concentration of 100 g/L. Diversity in the microbial community decreased during reactor establishment but increased at TDS concentrations above 80 g/L. Finally, the results of this study suggest that MBRs can be effective PW pretreatment processes even at high salinities.

42 ENGINEERING↗

Using Domain Insertion to Create Sulfite Reductases That Present Chemical-Dependent Activities

Domain insertion can be used to create oxidoreductases whose activities are dependent upon analyte binding. To date, most domain insertion studies have targeted relatively small oxidoreductases of known structure, so it remains unclear how to apply this protein engineering approach to large hetero-oligomeric proteins that require dynamic conformational changes for catalysis. To address this question, we studied the effects of peptide and domain insertions on the activity of NADPH-dependent sulfite reductase (SiR) from Escherichia coli, a dodecameric oxidoreductase containing four hemoprotein and eight flavoprotein subunits. SiR mutational tolerance was first evaluated using systematic octapeptide insertion and a cellular selection, which identified regions across the hemoprotein structure that retain parent-like activity following insertion. When a ligand-binding domain was inserted at backbone locations tolerant to peptide insertion, including sites proximal and distal from the intersubunit interfaces, ∼90% retained catalytic activity, and >50% presented activity that is regulated by an endocrine disruptor. With one domain insertion variant, the conditional production of sulfide could be monitored electrochemically from cells using a bioelectrochemical reactor. These results show how systematic peptide insertion can be used to inform domain insertion in a large heterooligomeric protein complex, and they illustrate how SiR can be engineered to convert chemical information in the environment into a redox-active metabolite that diffuses across the cell membrane.

bacteria↗

Silver Ion Biocide Delivery System for Water Disinfection

U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

Slote, Benjamin M.↗

Thin-sheet zeolite membrane and methods for making the same

Zeolite membrane sheets for separation of mixtures containing water are provided, as well as methods for making the same. Thin, but robust, zeolite membrane sheets having an inter-grown zeolite crystal film directly on a thin, less than 200 micron thick, porous support sheet free of any surface pores with a size above 10 microns. The zeolite membrane film thickness is less than about 10 microns above the support surface and less than about 5 microns below the support surface. Methods of preparing the membrane are disclosed which include coating of the support sheet surface with a seed coating solution containing the parent zeolite crystals with mean particle sizes from about 0.5 to 2.0 microns at loading of 0.05-0.5 mg/cm2 and subsequent growth of the seeded sheet in a growth reactor loaded with a growth solution over a temperature range of about 45° C. to about 120° C.

Liu, Wei↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A directional electrode separator improves anodic biofilm current density in a well-mixed single-chamber bioelectrochemical system

In this study, a directional electrode separator (DES) was designed and incorporated into a single-chamber bioelectrochemical system (BES) to reduce migration and reoxidation of hydrogen. This issue arises when H 2 , generated at the cathode, travels to the anode where anodic biofilms use H 2 . To test the feasibility of our design, a 3D-printed BES reactor equipped with a DES was inoculated with anaerobic digestor granules and operated under fed-batch conditions using fermented corn stover effluent. The DES equipped reactor achieved significantly higher current densities (~53 A/m²) compared to a conventional single-chamber BES without a separator (~16 A/m²), showing a 3.3 times improvement. Further, control abiotic electrochemical experiments revealed that the DES exhibited significantly higher proton conductivity (456±127 µS/mm) compared to a proton exchange membrane (67±21 µS/mm) with a statistical significance of P=0.03. The DES also effectively reduced H 2 migration to the anode by 21-fold relative to the control. Overall, incorporating a DES in a single-chamber BES enhanced anodic current density by reducing H 2 migration to the anode.

3D printed BES↗

Devices and methods for hydrogen generation via ammonia decomposition

Systems and methods for hydrogen generation via ammonia decomposition that utilize a fixed bed reactor configured to receive inflows of NH 3 and oxidant and to produce an outflow of high purity H 2 . The fixed bed reactor contains a fixed bed of a NH 3 decomposition catalyst wherewith the NH 3 decomposes to form N 2 and H 2 ; a plurality of ceramic hollows fibers with a high surface to volume ratio disposed in the fixed bed, the hollow fibers having an H 2 selective membrane disposed thereon for extracting H 2 from N 2 and to form a permeate of the high purity H 2 and a retentate of primarily N 2 ; and a catalytic H 2 burner also disposed in the fixed bed, the catalytic H 2 burner for burning a portion of the H 2 with the oxidant to provide thermal energy for the NH3 decomposition.

Li, Shiguang↗

Atmospheric Processing Module for Mars Propellant Production

The multi-NASA center Mars Atmosphere and Regolith COllector/PrOcessor for Lander Operations (MARCO POLO) project was established to build and demonstrate a methane/oxygen propellant production system in a Mars analog environment. Work at the Kennedy Space Center (KSC) Applied Chemistry Laboratory is focused on the Atmospheric Processing Module (APM). The purpose of the APM is to freeze carbon dioxide from a simulated Martian atmosphere containing the minor components nitrogen, argon, carbon monoxide, and water vapor at Martian pressures (approx.8 torr) by using dual cryocoolers with alternating cycles of freezing and sublimation. The resulting pressurized CO2 is fed to a methanation subsystem where it is catalytically combined with hydrogen in a Sabatier reactor supplied by the Johnson Space Center (JSC) to make methane and water vapor. We first used a simplified once-through setup and later employed a HiCO2 recycling system to improve process efficiency. This presentation and paper will cover (1) the design and selection of major hardware items, such as the cryocoolers, pumps, tanks, chillers, and membrane separators, (2) the determination of the optimal cold head design and flow rates needed to meet the collection requirement of 88 g CO2/hr for 14 hr, (3) the testing of the CO2 freezer subsystem, and (4) the integration and testing of the two subsystems to verify the desired production rate of 31.7 g CH4/hr and 71.3 g H2O/hr along with verification of their purity. The resulting 2.22 kg of CH4/O2 propellant per 14 hr day (including O2 from electrolysis of water recovered from regolith, which also supplies the H2 for methanation) is of the scale needed for a Mars Sample Return mission. In addition, the significance of the project to NASA's new Mars exploration plans will be discussed.

Muscatello, Anthony↗

Atmospheric Processing Module for Mars Propellant Production

The multi-NASA center Mars Atmosphere and Regolith COllector/PrOcessor for Lander Operations (MARCO POLO) project was established to build and demonstrate a methane/oxygen propellant production system in a Mars analog environment. Work at the Kennedy Space Center (KSC) Applied Chemistry Laboratory is focused on the Atmospheric Processing Module (APM). The purpose of the APM is to freeze carbon dioxide from a simulated Martian atmosphere containing the minor components nitrogen, argon, carbon monoxide, and water vapor at Martian pressures (~8 torr) by using dual cryocoolers with alternating cycles of freezing and sublimation. The resulting pressurized CO2 is fed to a methanation subsystem where it is catalytically combined with hydrogen in a Sabatier reactor supplied by the Johnson Space Center (JSC) to make methane and water vapor. We first used a simplified once-through setup and later employed a HiCO2 recycling system to improve process efficiency. This presentation and paper will cover (1) the design and selection of major hardware items, such as the cryocoolers, pumps, tanks, chillers, and membrane separators, (2) the determination of the optimal cold head design and flow rates needed to meet the collection requirement of 88 g CO2/hr for 14 hr, (3) the testing of the CO2 freezer subsystem, and (4) the integration and testing of the two subsystems to verify the desired production rate of 31.7 g CH4/hr and 71.3 g H20/hr along with verification of their purity. The resulting 2.22 kg of CH4/O2 propellant per 14 hr day (including O2 from electrolysis of water recovered from regolith, which also supplies the H2 for methanation) is of the scale needed for a Mars Sample Return mission. In addition, the significance of the project to NASA's new Mars exploration plans will be discussed.

Muscatello, Anthony↗

RECLAIM: Electrochemical Lithium and Nickel Extraction with Concurrent Carbon Dioxide Mineralization

This project aims to develop technologies toward the production of Li and Ni from CO 2 -reactive minerals and rocks that contain Ca and Mg, while sequestering CO 2 . The technologies include acoustic stimulation and electrolytic proton production, which use electricity to liberate valuable metal ions from the surrounding mineral matrix at sub-boiling temperatures (~20-80°C). Feedstocks include Li/Ni/Ca/Mg-rich igneous and sedimentary rocks and minerals such as holmquistite, hectorite, lateritic Ni ores enriched in Mg-rich serpentine. Other examples of feedstocks that could be used include coarse grained orthocumulate, mine tailings, etc. In the first step, the electrolytic breakdown of water to H + and OH – (as well as O 2 and H 2 ) will be induced by applying an electric potential to simultaneously produce acidity and alkalinity. The solid feedstocks will be dissolved in the acidic anolyte under acoustic stimulation. Solubilized species will then undergo separation using our unique Li + -selective membranes driven by electrodialysis, leading to concentration of Li as soluble lithium silicate, from which Li 2 CO 3 can be derived by reaction with CO 2(g) while supplying cathode alkalinity. Also at the cathode, stepwise electrolytic precipitation of metal hydroxides, including Ni(OH) 2 , Ca(OH) 2 , and Mg(OH) 2 is performed along a cascade reactor in which both the applied potential and pH increase downstream, thereby simultaneously extracting and separating the metals. Finally, exposure of Ca(OH) 2 and Mg(OH) 2 to dilute CO 2 will result in CO 2 uptake in the form of Ca and Mg carbonates. The primary accomplishments include sample procurement and characterization. Progress has been made on precursor identification and mapping, establishing protocols for assessing metal extractability under sonication, and preliminary technoeconomic analysis (TEA) and life cycle analysis (LCA).

36 MATERIALS SCIENCE↗

Electrically enhanced thermochemical cycles for hydrogen generation

In two-step metal-oxide (MO) solar thermochemical cycles, high temperature solar thermal energy is first converted to chemical energy in the form of a reduced MO. The reduced MO is then reoxidized in a second step with steam (or carbon dioxide) to produce hydrogen (or carbon monoxide) at a lower temperature. Solar thermochemical cycles of this type circumvent heat-to-electrical conversion required for electrochemical water splitting and promise high efficiencies. However, significant challenges remain to implementation. Ultra-high temperatures and efficiency-sapping low per-cycle conversion stand out as particularly difficult hurdles. Hybrid approaches utilizing both thermal and electrical energy provide some of the advantages of each, and can facilitate lower temperature operation and offer better per-pass utilization than thermochemical alone. However, early concepts for implementing the thermo-electrochemical approach introduced substantial new challenges including difficult separations, corrosive environments, and energy losses from large temperature swings and phase changes. We are currently investigating two different options for implementation. In the first, a MO that reduces at lower temperature is selected. As the reduced MO lacks the full thermodynamic driving force to effectively split water, the reaction is driven forward by an electrically-assisted proton-conducting membrane that separates and recovers hydrogen as it is produced. This approach produces a pure hydrogen stream, is mechanically simple, and has unique thermodynamic advantages. The second option seeks to more directly couple the electrical boost to the solid MO to drive either the reduction or oxidation step, or both, through the utilization of layered MO materials and advanced reactors. This approach could be applied to both water and carbon dioxide splitting. The results of process modeling and optimization will be presented, and progress towards demonstrating the concepts at the laboratory scale will be discussed.

08 HYDROGEN↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atmospheric Processing Module for Mars Propellant Production

The multi-NASA center Mars Atmosphere and Regolith COllectorPrOcessor for Lander Operations (MARCO POLO) project was established to build and demonstrate a methaneoxygen propellant production system in a Mars analog environment. Work at the Kennedy Space Center (KSC) Applied Chemistry Laboratory is focused on the Atmospheric Processing Module (APM). The purpose of the APM is to freeze carbon dioxide from a simulated Martian atmosphere containing the minor components nitrogen, argon, carbon monoxide, and water vapor at Martian pressures (8 torr) by using dual cryocoolers with alternating cycles of freezing and sublimation. The resulting pressurized CO(sub 2) is fed to a methanation subsystem where it is catalytically combined with hydrogen in a Sabatier reactor supplied by the Johnson Space Center (JSC) to make methane and water vapor. We first used a simplified once-through setup and later employed a H(sub 2)CO(sub 2) recycling system to improve process efficiency. This presentation and paper will cover (1) the design and selection of major hardware items, such as the cryocoolers, pumps, tanks, chillers, and membrane separators, (2) the determination of the optimal cold head design and flow rates needed to meet the collection requirement of 88 g CO(sub 2) hr for 14 hr, (3) the testing of the CO(sub 2) freezer subsystem, and (4) the integration and testing of the two subsystems to verify the desired production rate of 31.7 g CH(sub 4) hr and 71.3 g H(sub 2)O hr along with verification of their purity. The resulting 2.22 kg of CH(sub 2)O(sub 2) propellant per 14 hr day (including O(sub 2) from electrolysis of water recovered from regolith, which also supplies the H(sub 2) for methanation) is of the scale needed for a Mars Sample Return mission. In addition, the significance of the project to NASAs new Mars exploration plans will be discussed.

waste treatment↗

Atmospheric Processing Module for Mars Propellant Production

The multi-NASA center Mars Atmosphere and Regolith COllector/PrOcessor for Lander Operations (MARCO POLO) project was established to build and demonstrate a methaneoxygen propellant production system in a Mars analog environment. Work at the Kennedy Space Center (KSC) Applied Chemistry Laboratory is focused on the Atmospheric Processing Module (APM). The purpose of the APM is to freeze carbon dioxide from a simulated Martian atmosphere containing the minor components nitrogen, argon, carbon monoxide, and water vapor at Martian pressures (approx. 8 torr) by using dual cryocoolers with alternating cycles of freezing and sublimation. The resulting pressurized CO(sub 2) is fed to a methanation subsystem where it is catalytically combined with hydrogen in a Sabatier reactor supplied by the Johnson Space Center (JSC) to make methane and water vapor. We first used a simplified once-through setup and later employed a H(sub 2)CO(sub 2) recycling system to improve process efficiency. This presentation and paper will cover (1) the design and selection of major hardware items, such as the cryocoolers, pumps, tanks, chillers, and membrane separators, (2) the determination of the optimal cold head design and flow rates needed to meet the collection requirement of 88 g CO(sub 2) hr for 14 hr, (3) the testing of the CO(sub 2) freezer subsystem, and (4) the integration and testing of the two subsystems to verify the desired production rate of 31.7 g CH(sub 4) hr and 71.3 g H(sub 2)O hr along with verification of their purity. The resulting 2.22 kg of CH(sub 2)O(sub 2) propellant per 14 hr day (including O(sub 2) from electrolysis of water recovered from regolith, which also supplies the H(sub 2) for methanation) is of the scale needed for a Mars Sample Return mission. In addition, the significance of the project to NASAs new Mars exploration plans will be discussed.

hydrocarbon fuel production↗

Reaction–Diffusion Coupling Facilitates the Sequential Precipitation of Metal Ions from Battery Feedstock Solutions

Here, the development of new technologies for chemical separations is urgently needed to meet the surging demand for critical materials that has strained resources and caused environmental challenges. Inspired by the classic Liesegang experiment, we demonstrated the separation of critical metal ions based on the coupling of ion diffusion and precipitation kinetics. For this purpose, a model feedstock solution simulating dissolved battery electrodes was placed on top of a hydrogel loaded with a precipitating agent, namely sodium hydroxide. As the lithium, manganese, cobalt, and nickel ions diffused into the gel, a gradient of precipitates formed along the length of the reactor. Elemental analysis of the spatially distributed precipitates showed the enrichment of nickel near the gel-solution interface, followed by the formation of an almost pure (>96%) manganese product further along the reactor. Optimization experiments revealed that a sodium hydroxide concentration of 10 mM and a gel/solution volume ratio of 2:1 favored efficient separations. The robustness of the method was demonstrated in four out of five feedstock compositions of typically used battery cathodes. Our proof-of-concept experiments present a paradigm for critical materials separations that does not require specialty chemicals, binding agents, membranes, or toxic solvents.

25 ENERGY STORAGE↗

Parametric Study of the Vacuum Permeator for the Tritium Extraction eXperiment

Tritium breeding is a critical component of any self-sustaining future fusion reactor. The liquid metal eutectic, PbLi, is of particular interest as a tritium breeder material due to its favorable thermophysical and neutronic properties. One of the several remaining challenges facing PbLi breeder blankets is the need to design and validate a highly efficient tritium extraction system. The vacuum permeator is a promising extraction concept that utilizes tritium permeation through a highly permeable metal membrane. The Tritium Extraction eXperiment (TEX) is a forced-convection PbLi loop constructed to investigate tritium extraction from PbLi with vacuum permeators. Accurate thermal-hydraulic and tritium transport models are required to establish appropriate test matrices, predict experiment outcomes, and analyze data. However, the hydrogen transport properties of PbLi and permeator materials have large uncertainties. A database is collected, and a parametric analysis is conducted on the effect of hydrogen transport material properties: diffusivity of H in PbLi and permeator, solubility of H in PbLi and permeator, and permeator surface recombination constant on the expected tritium extraction efficiency for a vacuum permeator installed in TEX. As a result, we observe solubility of H in PbLi and the permeator and the recombination constant of the permeator have the largest effect on the extraction efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

High Data Rate Detector for Neutron Reflectometer

Neutron reflectometers are a class of instruments that employ neutron diffraction for measuring the structure of thin films. The technique provides valuable information over a wide variety of scientific and technological applications including chemical aggregation, polymer and surfactant adsorption, structure of thin film magnetic systems, biological membranes, etc. Such instruments are considered to be one of the most important in the neutron science field. Newer facilities place growing demands on the count rate capability of the specialized neutron detectors required. Proportional Technologies completed the Phase I effort successfully with a fully operational prototype detector built at PTI and tested at the CG1A neutron beam of the High Flux Isotope Reactor (HFIR, Oak Ridge, TN). The prototype incorporated 3 panels of 14 copper-walled cells each (total of 42 cells), each lined with 1.3 μm of 10B4C. The detector was tested for efficiency, spatial resolution, count rate linearity, uniformity, overlap and scatter. Testing revealed stable operation, uniform response across cells, and successful resolution of individual cells. The maximum count rate tested in the 3 panels combined was 590 kHz, limited by a deadtime of about 1 μs in the digital electronics. The local rate measured in a single cell showed no deadtime losses up to 810 cps/mm2, indicating that a rate of 20 Mhz can be supported in the 308-cell detector planned for Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗