Search NASA⌕ Search

SEARCH · Search NASA

Results for “metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Creation of depth-confined, shallow nitrogen-vacancy centers in diamond with tunable density

Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly sensitive single defects and ensembles with coherence limited by NV–NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. Here, we anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale nuclear magnetic resonance to entanglement-enhanced metrology.

Chemical vapor deposition↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

Entanglement-enhanced ac magnetometry in the presence of Markovian noise

Entanglement is a resource to improve the sensitivity of quantum sensors. In an ideal case, using an entangled state as a probe to detect target fields, we can beat the standard quantum limit by which all classical sensors are bounded. However, since entanglement is fragile against decoherence, it is unclear whether entanglement-enhanced metrology is useful in a noisy environment. Its benefit is indeed limited when estimating the amplitude of dc magnetic fields under the effect of parallel Markovian decoherence, where the noise operator is parallel to the target field. In this paper, on the contrary, we show an advantage to using an entanglement over the classical strategy under the effect of parallel Markovian decoherence when we try to detect ac magnetic fields. We consider a scenario to induce a Rabi oscillation of the qubits with the target ac magnetic fields. Although we can, in principle, estimate the amplitude of the ac magnetic fields from the Rabi oscillation, the signal becomes weak if the qubit frequency is significantly detuned from the frequency of the ac magnetic field. We show that, by using the Greenberger-Horne-Zeilinger (GHZ) states, we can significantly enhance the signal of the detuned Rabi oscillation even under the effect of parallel Markovian decoherence. Further, our method is based on the fact that the interaction time between the GHZ states and ac magnetic fields scales as 1/L to mitigate the decoherence effect, where L is the number of qubits, which contributes to improving the bandwidth of the detectable frequencies of the ac magnetic fields. Our results pave the way for new applications of entanglement-enhanced ac magnetometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combining quantum noise reduction resources: A practical approach

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. Here, we demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

Optomechanics↗

Dissipative Superradiant Spin Amplifier for Enhanced Quantum Sensing

Quantum metrology protocols exploiting ensembles of N two-level systems and Ramsey-style measurements are ubiquitous. However, in many cases excess readout noise severely degrades the measurement sensitivity; in particular in sensors based on ensembles of solid-state defect spins. We present a dissipative “spin-amplification” protocol that allows us to dramatically improve the sensitivity of such schemes, even in the presence of realistic intrinsic dissipation and noise. Our method is based on exploiting collective (i.e., superradiant) spin decay, an effect that is usually seen as a nuisance because it limits spin-squeezing protocols. We show that our approach can allow a system with a highly imperfect spin readout to approach standard-quantum-limit-like scaling in N within a factor of 2, without needing to change the actual readout mechanism. Our ideas are compatible with several state-of-the-art experimental platforms where an ensemble of solid-state spins (NV centers, SiV centers) is coupled to a common microwave or mechanical mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generating entangled steady states in multistable open quantum systems via initial state control

Entanglement underpins the power of quantum technologies, yet it is fragile and typically destroyed by dissipation. Paradoxically, the same dissipation, when carefully engineered, can drive a system toward robust entangled steady states. However, this engineering task is nontrivial, as dissipative many-body systems are complex, particularly when they support multiple steady states. Here, we derive analytic expressions that predict how the steady state of a system evolving under a Lindblad equation depends on the initial state, without requiring integration of the dynamics. These results extend Refs. [V. V. Albert and L. Jiang, Phys. Rev. A 89, 022118 (2014); V. V. Albert et al., Phys. Rev. X 6, 041031 (2016)], showing that while the steady-state manifold is determined by the Liouvillian kernel, the weights within it depend on both the Liouvillian and the initial state. We identify a special class of Liouvillians for which the steady state depends only on the initial overlap with the kernel. Our framework provides analytical insight and a computationally efficient tool for predicting steady states in open quantum systems. As an application, we propose schemes to generate metrologically useful entangled steady states in spin ensembles via balanced collective decay.

Dissipative dynamics↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Operando XPS in reactive plasmas: The importance of the wall reactions

In this article, advancements in differential pumping and electron optics over the past few decades have enabled x-ray photoelectron spectroscopy (XPS) measurements at (near-)ambient pressures, bridging the pressure gap for characterizing realistic sample chemistries. Recently, we have demonstrated the capabilities of an ambient pressure XPS setup for in situ plasma environment measurements, allowing plasma-surface interactions to be studied in operando rather than using the traditional before-and-after analysis approach. This new “plasma-XPS” technique facilitates the identification of reaction intermediates critical for understanding plasma-assisted surface processes relevant to semiconductor nanomanufacturing, such as physical vapor deposition, etching, atomic layer deposition, and many other plasma applications. In this paper, we apply the plasma-XPS approach to monitor real-time surface chemical changes on a model Ag(111) single crystal exposed to oxidizing and reducing plasmas. We correlate surface-sensitive data with concurrent gas-phase XPS measurements and residual gas mass-spectrum analysis of species generated during plasma exposure, highlighting the significant role of plasma-induced chamber wall reactions. Ultimately, we demonstrate that plasma-XPS provides comprehensive insights into both surface and gas-phase chemistry, establishing it as a versatile and dynamic characterization tool with broad applications in microelectronics research. Finally, we outline potential enhancements and future metrology directions to advance plasma-XPS investigations further.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Transmission estimation at the quantum Cramér-Rao bound with macroscopic quantum light

The field of quantum metrology seeks to apply quantum techniques and/or resources to classical sensing approaches with the goal of enhancing the precision in the estimation of a parameter beyond what can be achieved with classical resources. Theoretically, the fundamental minimum uncertainty in the estimation of a parameter for a given probing state is bounded by the quantum Cramér-Rao bound. From a practical perspective, it is necessary to find physical measurements that can saturate this fundamental limit and to show experimentally that it is possible to perform measurements with the required precision to do so. Here we perform experiments that saturate the quantum Cramér-Rao bound for transmission estimation over a wide range of transmissions when probing the system under study with a continuous wave bright two-mode squeezed state. To properly take into account the imperfections in the generation of the quantum state, we extend our previous theoretical results to incorporate the measured properties of the generated quantum state. For our largest transmission level of 84%, we show a 62% reduction over the optimal classical protocol in the variance in transmission estimation when probing with a bright two-mode squeezed state with -8 dB of intensity-difference squeezing. Given that transmission estimation is an integral part of many sensing protocols, such as plasmonic sensing, spectroscopy, calibration of the quantum efficiency of detectors, etc., the results presented promise to have a significant impact on a number of applications in various fields of research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser ultrasonic imaging of subsurface defects with the linear sampling method

Laser ultrasonics is a remote nondestructive evaluation technique suitable for real-time monitoring of fabrication processes in semiconductor metrology, advanced manufacturing, and other applications where non-contact, high fidelity measurements are required. Here we investigate laser ultrasonic data processing approaches to reconstruct images of subsurface side drilled holes in aluminum alloy specimens. We demonstrate through simulation that the model-based linear sampling method (LSM) can perform accurate shape reconstruction of single and multiple holes and produce images with well-defined boundaries. We experimentally confirm that LSM produces images that represent the internal geometric features of an object, some of which may be missed by conventional imaging.

42 ENGINEERING↗

Statistical methods for design and testing of 3D-printed polymers

Different statistical methods are used in various fields to qualify processes and products, especially in emerging technologies like Additive Manufacturing (AM) or 3D printing. Since several statistical methods are being employed to ensure quality production of the 3D-printed parts, an overview of these methods used in 3D printing for different purposes is presented in this paper. The advantages and challenges, to understanding the importance it brings for design and testing optimization of 3D-printed parts are also discussed. The application of different metrology methods is also summarized to guide future researchers in producing dimensionally-accurate and good-quality 3D-printed parts. Here, this review paper shows that the Taguchi Methodology is the commonly-used statistical tool in optimizing mechanical properties of the 3D-printed parts, followed by Weibull Analysis and Factorial Design. In addition, key areas such as Artificial Intelligence (AI), Machine Learning (ML), Finite Element Analysis (FEA), and Simulation require more research for improved 3D-printed part qualities for specific purposes. Future perspectives are also discussed, including other methods that can help further improve the overall quality of the 3D printing process from designing to manufacturing.

36 MATERIALS SCIENCE↗

Workshop on Ultra-Precision Control for Ultra-Efficient Devices (Workshop Report)

On April 21–23, the U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office (AMO) within the office of Energy Efficiency and Renewable Energy (EERE) held the second in a series of workshops on different topics related to semiconductor research and development (R&D) to increase energy efficiency. This workshop focused on ultra-energy-efficient devices and the ultra-precision manufacturing (UPM) processes and next-generation control and metrology technologies needed to manufacture these devices. In addition to the industry needs and RDD&D opportunities, AMO’s new goal on greenhouse gas (GHG) reduction was addressed. The output of this workshop will inform AMO’s future R&D portfolio investments; provide perspectives on trends, drivers, and challenges for ultra-energy-efficient devices and enabling technologies; and help the stakeholder community understand the opportunities on the horizon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation, UQ, and Sensitivity Analysis for a New Diagnostic Setup [Slides]

This is for an early career talk I am giving at the Association for Women in Math’s Research Symposium. It provides a general overview of three projects: the first focuses on velocity measurements from optical laser diagnostics, the second focuses on probe alignment and location (metrology), and the third is my Site-Directed Research and Development (SDRD) which focuses on neural networks for image datasets. All three projects have strong uncertainty quantification components.

97 MATHEMATICS AND COMPUTING↗

Characterization of Contact Degradation in Crystalline Silicon Photovoltaic Modules (Final Technical Report)

In this project, the aim was to develop highly-automated metrology methods that can provide more insights into degradation and failure, while still relying on the types of measurements the PV industry and RD communities are comfortable with (e.g., I – V and EL). In particular, our focus was to develop techniques to better understand contact and interconnect degradation in crystalline silicon (c-Si) PV modules and apply those techniques to conventional and emerging c-Si cell architectures and cell interconnection technologies.

14 SOLAR ENERGY↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗