Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro-CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

NDE for Characterizing Oxidation Damage in Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter s thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using NDE methods. These specimens were heat treated in air at 1143 and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3 mm. Single-sided NDE methods were used since they might be practical for on-wing inspection, while x-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally-cracked coating and subsequent oxidation damage was also studied with x-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating. The results of that study are briefly reviewed in this article as well. Additionally, a short discussion on the future role of simulation to aid in these studies is provided.

Roth, Don J.↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 C and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3mm. Single-sided NDE methods were used because they might be practical for on-wing inspection, while X-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally cracked coating and subsequent oxidation damage was also studied with X-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Preserving the Science Legacy from the Apollo Missions to the Moon

Six Apollo missions landed on the Moon from 1969-72, returning to Earth 382 kg of lunar rock, soil, and core samples-among the best documented and preserved samples on Earth that have supported a robust research program for 45 years. From mission planning through sample collection, preliminary examination, and subsequent research, strict protocols and procedures are followed for handling and allocating Apollo subsamples. Even today, 100s of samples are allocated for research each year, building on the science foundation laid down by the early Apollo sample studies and combining new data from today's instrumentation, lunar remote sensing missions and lunar meteorites. Today's research includes advances in our understanding of lunar volatiles, lunar formation and evolution, and the origin of evolved lunar lithologies. Much sample information is available to researchers at curator.jsc.nasa.gov. Decades of analyses on lunar samples are published in LPSC proceedings volumes and other peer-reviewed journals, and tabulated in lunar sample compendia entries. However, for much of the 1969-1995 period, the processing documentation, individual and consortia analyses, and unpublished results exist only in analog forms or primitive digital formats that are either inaccessible or at risk of being lost forever because critical data from early investigators remain unpublished. We have initiated several new efforts to rescue some of the early Apollo data, including unpublished analytical data. We are scanning NASA documentation that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical database called Moon DB. To populate this database, we are working with prominent lunar PIs to organize and transcribe years of both published and unpublished data. Other initiatives include micro-CT scanning of complex lunar samples to document their interior structure (e.g. clasts, vesicles); linking high-resolution scans of Apollo film products to samples; and new procedures for systematic high resolution photography of samples before additional processing, enabling detailed 3D reconstructions of the samples. All of these efforts will provide comprehensive access to Apollo samples and support better curation of the samples for decades to come.

Evans, Cindy↗

Small Particle Impact Damage on Different Glass Substrates

Impact experiments using sand particles were performed on four distinct glass substrates. The sand particles were characterized using the X-Ray micro-CT technique; 3-D reconstruction of the particles was followed by further size and shape analyses. High-speed video footage from impact tests was used to calculate the incoming and rebound velocities of the individual sand impact events, as well as particle volume. Further, video analysis was used in conjunction with optical and scanning electron microscopy to relate the incoming velocity and shape of the particles to subsequent fractures, including both radial and lateral cracks. Analysis was performed using peridynamic simulations.

Waxman, R.↗

From Tomography to Material Properties of Thermal Protection Systems

A NASA Ames Research Center (ARC) effort, under the Entry Systems Modeling (ESM) project, aims at developing micro-tomography (micro-CT) experiments and simulations for studying materials used in hypersonic entry systems. X-ray micro-tomography allows for non-destructive 3D imaging of a materials micro-structure at the sub-micron scale, providing fiber-scale representations of porous thermal protection systems (TPS) materials. The technique has also allowed for In-situ experiments that can resolve response phenomena under realistic environmental conditions such as high temperature, mechanical loads, and oxidizing atmospheres. Simulation tools have been developed at the NASA Ames Research Center to determine material properties and material response from the high-fidelity tomographic representations of the porous materials with the goal of informing macroscopic TPS response models and guiding future TPS design.

Tomography↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗

Bridging the Gap Between Microscale Modeling and Additive Manufacturing for TPS

An overview of the now open-source NASA ARC software PuMA will be provided. On top of the well-documented ability to import and compute material properties from micro-CT images, PuMA has the ability to design microstructures and compute/predict material properties such as: porosity, permeability, tortuosity, thermal and electrical conductivity, tensile strength, etc. Therefore, a whole new range of capabilities is available, and provides users with the ability to build TPS materials (both fibrous and woven types) and optimize their properties based on missions and requirements. This talk will aim to provide a seed to start bridging the gap between microscale modeling of TPS materials and additive manufacturing.

Conductivity↗

Multiscale Modeling of Reconstructed Tricalcium Silicate using NASA Multiscale Analysis Tool

To study microstructure characteristics of cementitious materials hydrated in space; previously, cement binder formations were processed under microgravity conditions and was further compared against ground-based experiments. For accurate estimation of process-structure-property linkage, particularly on samples hydrated in the microgravity environment, it is desired to have a high-fidelity volumetric representation of the microstructure. However, owing to small sample size and high porosity of the space-returned samples, conventional experimental characterization techniques are not viable. Hence, a deep learning-based reconstruction algorithm was employed to obtain high fidelity 3D volumes from sparse high resolution 2D Scanning Electron Microscopy (SEM) images, as inputs to micromechanics-based modeling. This machine learning-based reconstruction methodology validated against low-order statistical descriptors, captured the microstructural topology of both sample types (ground, 1g and microgravity, μg). Due to the lack of gravity, hydration products of the samples processed in space differed from those processed-on ground. Such AI-generated virtual samples were analyzed in a multiscale recursive micromechanics approach using the NASA Multiscale Analysis Tool (NASMAT). Here, we present a methodology to rapidly integrate and evaluate these AI-generated volumes in NASMAT. The synthesized microstructural volumes are directly employed as Representative Volume Elements (RVEs) to preserve the fidelity (1 pixel = 0.54 m). Invariably, analysis of such largescale problems (5123 voxels) requires huge amount of computational resources. By taking advantage of the NASMAT architecture, we also focused on systematic multiscale integration of these AI-reconstructed virtual volumes to reduce the computational demands. In this work, this methodology is demonstrated on the ground-based, 1g samples. The estimated stiffness value of 15.90 GPa is comparable to experimentally obtained modulus of hydrated tricalcium silicate sample. The workflow presented here paves the way for utilizing the NASMAT tool to perform multiscale analyses of other multi-phase material systems using either 3D virtual datasets synthesized using AI or obtained via micro-CT.

Machine Learning↗

AI-Enhanced Computational Tools for Entry Systems Modeling

To advance the understanding of complex atmospheric entry phenomena, NASA’s Entry Systems Modeling (ESM) team [1] has developed high-fidelity computational tools addressing multiscale challenges, from material microstructures to full-scale heatshield response. This abstract highlights a subset of ESM tools, focusing on AI integration to enhance workflows and predictive modeling. - PuMA [2] computes effective material properties from high-resolution micro-CT scans, supporting TPS analysis for NASA missions. - TomoSAM [3] automates 3D tomography dataset segmentation for PuMA using the Segment Anything Model, reducing manual effort and improving accuracy. - PATO [4] models porous reactive materials under extreme conditions, with advancements such as unified solvers, mechanical erosion, and TPS coatings for NASA missions. - arcjetCV [5] employs deep learning to analyze arc jet test footage, measuring recession rates, shape changes, and shock standoff distances, bridging simulations, and experiments to reveal TPS ablation behavior. - ARCHeS [6] simulates arc heater plasma flows, modeling turbulence, radiation, and electromagnetic interactions to optimize arc heater performance, validate TPS under extreme conditions, and serve as a foundation for developing digital twins of arc heater facilities. - SPARTA [7] simulates rarefied hypersonic flows and gas-surface interactions for planetary entry missions, leveraging GPU architectures for scalable and efficient aerothermal and ablation analyses. AI-driven solutions, such as deep learning segmentation, have streamlined workflows in ESM tools and still hold significant potential to further accelerate processes and enhance automation in entry systems modeling. [1] Haskins, J.B. (2023), [2] Ferguson, J.C. (2018), [3] Meurisse, J.B.E. (2018), [4] Semeraro, F. (2023), [5] Quintart, A. (2024) [6] Meurisse, J.B.E. (2022), [7] Plimpton, S.J. (2019)

Predictive Modeling↗

Investigation of Lunar-Inspired Geopolymer Concrete Formulations Mixed and Cured in Microgravity on the International Space Station (ISS)

The research outlined in this presentation investigates the use of various lunar regolith simulants in geopolymer lunar concrete mixes mixed and cured on the International Space Station (ISS). The motivation for this work is to study the effects of gravity on the microstructure of alkali-activated materials cured with heat, and to develop materials for the construction of long-term infrastructure on the lunar surface with in-situ resource utilization (ISRU). ISRU for construction materials reduces the cost and mass of payloads related to lunar construction. The advantage of geopolymer concrete as opposed to traditional portland cement concrete is that water acts as a medium for the polymerization reaction and leaves the system throughout the process, reducing its demand. Twelve samples of lunar regolith simulant and a solution composed of sodium hydroxide and sodium silicate were sent to the ISS. The three simulants were OPRH2N, OPRL2N, and JSC-1AF, using only particles less than 53 µm in diameter to increase reactivity of the simulant. Simulant to solution ratios were determined by workability while mixing. The simulant and solution were sealed Burst Pouches® along with 2 other sealed bags to prevent material from leaking. Crew member F-14 conducted testing on the ISS by introducing the solution to the simulant in the Burst Pouch®, mixing the sample with a spatula, and then clamping the specimen in the fresh state to prevent flow inside the Burst Pouch®. These specimens were then put in a thermos heated to 80C via sealed drinking water bags to cure for 24 hours with a temperature logger. The cured specimens remained in microgravity for at least 28 days and were returned from the ISS in February 2025. The specimens were then brought to the NASA Marshall Space Flight Center (MSFC) to analyze. Material characterization consisted of conducting Micro-CT tests of entire samples in their sealed apparatus to a resolution of 25µm. 2D image slices were saved in each orthogonal direction of each specimen at a 0.03 mm step size from the 3D model to conduct analytical porosity calculations. Representative samples from each specimen were sampled to perform helium gas pycnometery and were then mounted in resin for SEM imaging, EDS, and nanoindentation. Porosity was analyzed analytically using micromechanics modelling with the assistance of the NASA Multiscale Analysis Tool (NASMAT), as well as the NASA Advanced Supercomputing (NAS) servers (V. Saseendran & N. Yamamoto, 2024). Density was measured using helium gas pycnometery and was then compared to the theoretical density for experimental porosity calculation. Due to the samples’ non-uniform shape being cured in a pouch, traditional compression and tensile strength testing could not be performed. Nanoindentation was conducted at Clarkson University to determine the microhardness and reduced modulus of elasticity. Results from flight samples can be compared to ground samples currently in DLR’s possession to determine the effect on microstructure from being mixed and cured in microgravity. This study gives further insight and understanding of geopolymer lunar concrete and its viability as a lunar construction material with ISRU.

Adam Johnson↗

Synchrotron‐source micro‐x‐ray computed tomography for examining butterfly eyes

Comparative anatomy is an important tool for investigating evolutionary relationships among species, but the lack of scalable imaging tools and stains for rapidly mapping the microscale anatomies of related species poses a major impediment to using comparative anatomy approaches for identifying evolutionary adaptations. We describe a method using synchrotron source micro-x-ray computed tomography (syn-μXCT) combined with machine learning algorithms for high-throughput imaging of Lepidoptera (i.e., butterfly and moth) eyes. Our pipeline allows for imaging at rates of ~15 min/mm 3 at 600 nm 3 resolution. Image contrast is generated using standard electron microscopy labeling approaches (e.g., osmium tetroxide) that unbiasedly labels all cellular membranes in a species-independent manner thus removing any barrier to imaging any species of interest. To demonstrate the power of the method, we analyzed the 3D morphologies of butterfly crystalline cones, a part of the visual system associated with acuity and sensitivity and found significant variation within six butterfly individuals. Despite this variation, a classic measure of optimization, the ratio of interommatidial angle to resolving power of ommatidia, largely agrees with early work on eye geometry across species. We show that this method can successfully be used to determine compound eye organization and crystalline cone morphology. Our novel pipeline provides for fast, scalable visualization and analysis of eye anatomies that can be applied to any arthropod species, enabling new questions about evolutionary adaptations of compound eyes and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Using synchrotron X-ray phase-contrast micro-computed tomography to study tissue damage by laser irradiation: STUDY TISSUE DAMAGE BY LASER IRRADIATION

Background and Objective: The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. Study Design/Materials and Methods: A surgical CO2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phasecontrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. Results: We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumeswere performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. Conclusion: We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues.

Ablation↗

Quantifying the heterogeneity of shale through statistical combination of imaging across scales

Shale is a highly heterogeneous material across multiple scales. A typical shale consists of nanometer-scale pores and minerals mixed with macro-scale fractures and particles of varying size. High-resolution imaging is crucial for characterizing the composition and microstructure of this rock. Yet, it is generally not feasible to image a large sample of shale at a high resolution over a large field of view (FOV), thus limiting a full characterization of the microstructure of this material. We present a stochastic framework based on multiple-point statistics that uses high-resolution training images to enhance low-resolution images obtained over a large FOV. Here, we demonstrate the approach using X-ray micro-tomography images of organic-rich Woodford shale obtained at two different resolutions and FOV. Results show that the proposed technique can generate realistic high-resolution images of the microstructure of shale over a large FOV.

58 GEOSCIENCES↗

Gas pore correlations in laser powder bed fusion of Al6061

Additive manufacturing (AM) of metal materials based on powder bed fusion technology is widely used now in many industries. A known limitation of this type of manufacturing is the formation of gas pores in the bulk material. Here we present a combined X-ray imaging and mid-infrared pyrometry study of pore formation in side-by-side tracks of Al6061 for different processing conditions using both in-situ and post-processing analysis. By carefully quantifying the distributions and correlations of pore positions, we show that an existing pore in one track often catalyzes the formation of another pore in an adjacent track. In a raster scan strategy commonly used to construct bulk material, this phenomenon has the result of forming subsurface perforations, or lines of pores transverse to the scanning direction in a rastered patch. If controlled, this effect can be eliminated to improve the yield strength of the build, or exploited to create programmable failures for specific purposes.

36 MATERIALS SCIENCE↗

Simulation toolkit for digital material characterization of large image-based microstructures

In this paper, an efficient image-based simulation toolkit for material characterization is presented, which is scalable to work from personal computers to workstations. The effective thermal conductivity, elasticity, and permeability are evaluated employing a computational homogenization framework based on the Finite Element Method (FEM). Two complementary open-source packages are presented: one developed in Python, which can convert digital images into voxel meshes (pyTomoviewer); the other developed in Julia, that can run numerical simulations to compute effective material properties (chpack). Also, a CUDA C version of chpack is provided (chfem_gpu). They were designed to deal with large multi-phase models, so strategies were devised to minimize their memory footprint, while avoiding a high toll on execution time. The voxel-based approach significantly simplifies the FEM meshes and allows efficient matrix-free implementations. In that sense, to handle large linear systems of equations, the element-by-element (EBE) technique is adopted, in conjunction with a low-memory implementation of the Preconditioned Conjugate Gradient (PCG) method. Finally, the code was thoroughly tested on an artificial geometry made of a square array of cylinders, for which analytical solutions exist, as well as on a real micro-tomographic reconstruction of FiberForm TM , a carbon preform commonly used in thermal protection systems.

36 MATERIALS SCIENCE↗

Characterization of paste microstructure for durability properties of concrete

In this study, paste samples from different cementitious systems were characterized by using X-Ray Micro Computed Tomography (µ-CT) and Fluorescence Microscopy techniques. Quantitative and qualitative aspects of defects from paste samples were investigated to develop indicators of durability related properties of corresponding concrete samples. In the first phase of this study, hour glass shaped 3D printed molds were used to investigate five cementitious combinations consisting of three cement types (Coarse Ground portland cement, Type IL Portland Limestone Cement and Type I/II ordinary portland cement) and fly ash as a supplementary cementitious material. In the second phase, metal molds were used to compare the results of Coarse Ground portland cement with Type I ordinary portland cement, 5% of which was replaced with colloidal nanosilica. Potential correlations between paste and concrete have been presented. This work was supported by US Department of Energy and North Dakota Department of Commerce.

36 MATERIALS SCIENCE↗