Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

On-axis 3D microscope for x-ray beamlines at NSLS-II

A series of versatile on-axis X-ray microscopes with large working distances, high resolution and large magnification have been developed at NSLS-II [1,2]. These microscopes use reflective optics, which minimizes dispersion, and allows imaging from Ultraviolet (UV) [3] to Infrared (IR) with specifically chosen objective components (coatings, etc.). Additional customizations can be implemented to provide dual-view with high/low magnification [4], 3-D imaging, long working range, as well as ruby fluorescence measurement for high pressure samples. In this publication we discuss 3D imaging enhancement to on-axis microscopes.

47 OTHER INSTRUMENTATION↗

Microscopic calculation of fission fragment energies for the 239 Pu( n th ,f ) reaction

We calculate the total kinetic and excitation energies of fragments produced in the thermal-induced fission of 239 Pu. This result is a proof-of-principle demonstration for a microscopic approach to the calculation of fission-fragment observables for applied data needs. In addition, the calculations highlight the application of a fully quantum mechanical description of scission, and the importance of exploring scission configurations as a function of the moments of the fragments, rather than through global constraints on the moments of the fissioning nucleus. Using a static microscopic calculation of configurations at and near scission, we have identified fission fragments for the 239 Pu ( n th ,f ) reaction and extracted their total kinetic and excitation energies. Comparison with data shows very good overall agreement between theory and experiment. Beyond their success as a proof of principle, these calculations also highlight the importance of local constraints on the fragments themselves in microscopic calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Microscopic Materials Limitations of Superconducting RF Cavities

The high-field performance of SRF cavities is often limited by breakdown events below the intrinsic limiting surface fields of Nb, and there is abundant evidence that these breakdown events are localized in space inside the cavity. Also, there is a lack of detailed understanding of the causal links between surface treatments and ultimate RF performance at low temperatures. An understanding of these links would provide a clear roadmap for improvement of SRF cavity performance, and establish a cause-and-effect ‘RF materials science’ of Nb. We propose two specific microscopic approaches to addressing these issues. First is a spatially-resolved local microwave-microscope probe that operates at SRF frequencies and temperatures to discover the microscopic origins of breakdown, and produce quantitative measurements of RF critical fields of coatings and films. Second, RF Laser Scanning Microscopy (LSM) has allowed visualization of RF current flow and sources of nonlinear RF response in superconducting devices with micro-meter spatial resolution. The LSM will be used in conjunction with surface preparation and characterization techniques to create definitive links between physical and chemical processing steps and ultimate cryogenic microwave performance. We propose to develop RF laser scanning microscopy of small-sample Nb pieces to establish surface-processing / RF performance relations through measurement of RF current distributions on micron-length scales and low temperatures.

36 MATERIALS SCIENCE↗

Search for Microscopic Black Hole Signatures at the Large Hadron Collider

A search for microscopic black hole production and decay in proton-proton collisions at a center-of-mass energy of 7 TeV has been conducted using Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider. A total integrated luminosity of 35 pb -1 data sample, taken by CMS Collaboration in year 2010, has been analyzed. A novel background estimation for multi-jet events beyond TeV scale has been developed. A good agreement with standard model backgrounds, dominated by multi-jet production, is observed for various final-state multiplicities. Using semi-classical approximation, upper limits on minimum black hole mass at 95% confidence level are set in the range of 3.5 - 4.5 TeV for values of the Planck scale up to 3 TeV. Model-independent limits are provided to further constrain microscopic black hole models with additional regions of parameter space, as well as new physics models with multiple energetic final states. These are the first limits on microscopic black hole production at a particle accelerator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic Investigation of Materials Limitations of Superconducting RF Cavities

Our overall goal is to contribute to the understanding of defects that limit the high accelerating gradient performance of Nb SRF cavities. Our approach is to develop a microscopic connection between materials defects and SRF performance. We developed a near-field microwave microscope to establish this connection. The microscope is based on magnetic hard drive write heads, which are designed to create very strong rf magnetic fields in very small volumes on a surface.

36 MATERIALS SCIENCE↗

Development of the Tagger Microscope & Analysis of Spin Density Matrix Elements in gamma-p -> phi-p for the GlueX Experiment

The quark model has been successful in classifying the spectrum of mesons observed since the 1960s, however, it fails to explain some of the measured bound states. Lattice QCD predictions have shown that an excited gluonic field may contribute to the quantum numbers of the bound state and form hybrid mesons, qq-bar-g, where g is a constituent gluon. It is possible for some hybrids to possess quantum numbers forbidden by the quark model and are known as \smoking gun" hybrids due to their lack of mixing with conventional qq-bar states. The GlueX photoproduction experiment at Jefferson Lab in Newport News, VA is designed to study hybrid mesons and to map their spectrum. A 12 GeV electron beam produces 9 GeV linearly polarized photons via coherent bremsstrahlung in a diamond radiator which are incident on a liquid H2 target. In order to determine the photon energy, the use of a tagging spectrometer which measures the energy of the post-bremsstrahlung electron is required. The tagger microscope is a scintillating fiber detector designed to measure the energy of electrons corresponding to the polarized photons. The main focus of this work is the design and construction of the tagger microscope electronics as well as the calibration of the microscope within the experiment. Additionally, the analysis of the reaction gamma-p -> phi-p, where phi (1020) -> K+K-, is discussed. This analysis provides a high-level calibration for GlueX in regards to understanding the acceptance and sensitivity of the detectors to mesons with strange quark content. By studying the phi with linearly polarized photons, information on the production mechanism can be extracted. The measurement of the phi spin-density matrix elements are shown and compared with past data which are found to be in agreement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vibrational Sum Frequency Generation Spectroscopy Microscope

Vibrational sum frequency generation spectroscopy has the benefit of being very surface-specific, aiding in the the investigation of a given material’s surface chemical and physical properties. As such, the goal of this project was to construct a sum frequency generation microscope that would enable the investigation of surface phenomena on a microscopic scale. Currently, the microscope hardware has been assembled and programmed, and simple spectral images were taken with elastically scattered 532 nm light. These images indicate an image resolution near 3 µm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and implementation of an in situ high-resolution isotopic microscope for measuring metabolic interactions in soil mesocosms (Final Report)

Many of our planet’s ecosystems rely on the activities of soil microbial communities. These microbes have significant and wide-ranging effects: they metabolize carbon and other nutrients, interact with plants and fungi, and perform other processes important to soil health. However, our ability to directly observe the enzymatic and metabolic activities of microbes within soil is currently limited, not only by the complexity of soil microbial communities themselves, but also by the lack of experimental tools to study them and their molecular interactions in situ. These challenges hinder our understanding of the life-sustaining processes of biomass decomposition and the manner in which it contributes to the movement of freed carbon within soil ecosystems. Here we aimed to develop a novel ultrahigh-resolution isotopic microscope that combines complementary imaging modalities to gain insights into metabolic cycling in soil. This final report covers both the portion of this work that was initially completed at the University of North Carolina at Chapel Hill from 2018 to 2019 (as award DE-SC0019012) and then from 2020 to 2022 (2023 in NCE) at the University of Massachusetts Chan Medical School. This goal was to build an integrated platform consisting of fluorescence microscopy, Raman microspectroscopy, and nanospray desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoDESI-FTICR-MS) to directly investigate microbial activities and molecular transformations occurring in soil by exploiting the use of both fluorescent labels and stable isotope probing. Specifically, our instrument was conceived as integrating: (A) fluorescence detection to localize soil microbes, identify bacteria taking up polysaccharides, and monitor gene expression of enzymes involved in decomposition; (B) Raman microspectroscopy to determine which microbes incorporate decomposition products into their biomass, as well as which decomposers are metabolically active; and (C) nanoDESI-FTICR-MS imaging to spatially probe, in real-time, the metabolites in the surrounding area, which we expect will reveal the distributions of the products of the enzymatic breakdown of polysaccharides, as well as specialized metabolites acting as cell-cell signals between decomposers. To enable these measurements, we exploited fluorescence-based probes to map the microbes that are enzymatically active (per A) and utilized stable isotope-labeled substrates to visualize both the microbial and molecular fate of decomposed biomass (B and C, respectively). To accomplish our goal, we combined the expertise of a multidisciplinary group of scientists to pursue the construction of this microscope and to investigate scientific questions that would be facilitated by such a capability. We aimed to employ this spatially informative, high-resolution isotopic microscope to visualize the critical steps of biomass degradation and the molecular fate of other environmentally relevant substrates within soil mesocosms. Accordingly, this technology will enhance our understanding of the microbial and metabolic interactions occurring within soil communities that are relevant to carbon degradation and other soil processes. The instrument has been developed and housed at EMSL, where it will be available to the entire EMSL User Base, enabling a variety of related DOE-relevant systems to be interrogated in the future by diverse scientific research groups.

59 BASIC BIOLOGICAL SCIENCES↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Spectro-Microscopic Measurements of Carbonaceous Aerosol Aging in Central California

Carbonaceous aerosols are responsible for large uncertainties in climate models, degraded visibility, and adverse health effects. The Carbonaceous Aerosols and Radiative Effects Study (CARES) was designed to study carbonaceous aerosols in the natural environment of Central Valley, California, and learn more about their atmospheric formation and aging. This paper presents results from spectro-microscopic measurements of carbonaceous particles collected during CARES at the time of pollution accumulation event (June 27-29, 2010), when in situ measurements indicated an increase in the organic carbon content of aerosols as the Sacramento urban plume aged. Computer controlled scanning electron microscopy coupled with an energy dispersive X-ray detector (CCSEM/EDX) and scanning transmission X-ray microscopy coupled with near edge X-ray absorption spectroscopy (STXM/NEXAFS) were used to probe the chemical composition and morphology of individual particles. It was found that the mass of organic carbon on individual particles increased through condensation of secondary organic aerosol. STXM/NEXAFS indicated that the number fraction of homogenous organic particles lacking inorganic inclusions (greater than ~50 nm diameter) increased with plume age as did the organic mass per particle. Comparison of the CARES spectro-microscopic data set with a similar dataset obtained in Mexico City during the MILAGRO campaign showed that individual particles in Mexico City contained twice as much carbon as those sampled during CARES. The number fraction of soot particles at the Mexico City urban site (30%) was larger than at the CARES urban site (10%) and the most aged samples from CARES contained less carbon-carbon double bonds. Differences between carbonaceous particles in Mexico City and California result from different sources, photochemical conditions, gas phase reactants, and secondary organic aerosol precursors. The detailed results provided by these spectro-microscopic measurements will allow for a comprehensive evaluation of aerosol process models used in climate research.

Environmental Molecular Sciences Laboratory↗

Cryogenic immersion microscope

A cryogenic immersion microscope whose objective lens is at least partially in contact with a liquid reservoir of a cryogenic liquid, in which reservoir a sample of interest is immersed is disclosed. When the cryogenic liquid has an index of refraction that reduces refraction at interfaces between the lens and the sample, overall resolution and image quality are improved. A combination of an immersion microscope and x-ray microscope, suitable for imaging at cryogenic temperatures is also disclosed.

Le Gros, Mark↗

Apparatus and methods for controlling electron microscope stages

Methods and apparatus for generating an image of a specimen with a microscope (e.g., TEM) are disclosed. In one aspect, the microscope may generally include a beam generator, a stage, a detector, and an image generator. A plurality of crystal parameters, which describe a plurality of properties of a crystal sample, are received. In a display associated with the microscope, an interactive control sphere based at least in part on the received crystal parameters and that is rotatable by a user to different sphere orientations is presented. The sphere includes a plurality of stage coordinates that correspond to a plurality of positions of the stage and a plurality of crystallographic pole coordinates that correspond to a plurality of polar orientations of the crystal sample. Movement of the sphere causes movement of the stage, wherein the stage coordinates move in conjunction with the crystallographic coordinates represented by pole positions so as to show a relationship between stage positions and the pole positions.

42 ENGINEERING↗

Spiking retina microscope

A spiking retina microscope comprising microscope optics and a neuromorphic imaging sensor. The microscope optics are configured to direct a magnified image of a specimen onto the neuromorphic imaging sensor. The neuromorphic imaging sensor comprises a plurality of sensor elements that are configured to generate spike signals in response to integrated light from the magnified image reaching a threshold. The spike signals may be processed by a processor unit to generate a result, such as tracking biological particles in a specimen comprising biological material.

Severa, William Mark↗

Quantum dot microscope apparatus comprising a nanoscale semiconductor on the tip of a fiber, a tunneling electrical lead and a capacitive electrical lead on the fiber

A quantum dot microscope apparatus is provided. A further aspect employs a tilted or tapered end or tip on a microscopic probe. Another aspect of the present apparatus employs a probe including a quantum dot with only one tunneling lead connected to a power source. A manufacturing aspect includes creating a tapered or asymmetrically shaped specimen-facing end of a probe where a quantum dot is located on the end. A further manufacturing aspect includes using focused ion-beam milling to create a tip or end of a quantum dot microscope probe.

Tessmer, Stuart Holden↗

Pushing the limits: characterisation and performance of the prototype multilayer Laue lenses fluorescence microscope with a view to achieve nm-scale spatial resolution

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics. We utilised the Imaging and Coherence beamline (I13) at Diamond Light Source to perform X-ray testing of the scanning microscope.

36 MATERIALS SCIENCE↗

Avoided Level Crossing and Entangled States of Interacting Hydrogen Molecules Detected by the Quantum Superposition Microscope

Pump–probe measurements by ultrashort THz pulses can be used to excite and follow the coherence dynamics in the time domain of single hydrogen molecules (H 2 ) in the junction of a scanning tunneling microscope (STM). By tailoring the resonance frequency through the sample bias, we identified two spectral signatures of the interactions among multiple H 2 molecules. First, the avoided level crossing featured by energy gaps ranging from 20 to 80 GHz was observed because of the level repulsion between two H 2 molecules. Second, the tip can sense the signal of H 2 outside the junction through the projective measurement on the H 2 inside the junction, owing to the entangled states created through the interactions. A dipolar-type interaction was integrated into the tunneling two-level system model of H 2 , enabling accurate reproduction of the observed behaviors. Furthermore, our results obtained by the quantum superposition microscope reveal the intricate quantum mechanical interplay among H 2 molecules and additionally provide a 2D platform to investigate unresolved questions of amorphous materials.

36 MATERIALS SCIENCE↗

Measurement of Semiconductor Surface Potential using the Scanning Electron Microscope

We calibrate the secondary electron signal from a standard scanning electron microscope to voltage, yielding an image of the surface or near-surface potential. Data on both atomically abrupt heterojunction GaInP/GaAs and diffused homojunction Si solar cell devices clearly show the expected variation in potential with position and applied bias, giving depletion widths and locating metallurgical junctions to an accuracy better than 10 nm. In some images, distortion near the p-n junction is observed, seemingly consistent with the effects of lateral electric fields (patch fields). Reducing the tube bias removes this distortion. This approach results in rapid and straightforward collection of near-surface potential data using a standard scanning electron microscope.

14 SOLAR ENERGY↗

Nanoscale Energy-Filtered Scanning Confocal Electron Microscopy Using a Double-Aberration-Corrected Transmission Electron Microscope

We demonstrate that a transmission electron microscope fitted with two spherical-aberration correctors can be operated as an energy-filtered scanning confocal electron microscope. A method for establishing this mode is described and initial results showing 3D chemical mapping with nanoscale sensitivity to height and thickness changes in a carbon film are presented. Importantly, uncorrected chromatic aberration does not limit the depth resolution of this technique and moreover performs an energy-filtering role, which is explained in terms of a combined depth and energy-loss response function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗