Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Large area fabrication of plasmonic nanoparticle grating structure by conventional scanning electron microscope

Plasmonic nanoparticle grating (PNG) structure of different periods has been fabricated by electron beam lithography using silver halide based transmission electron microscope film as a substrate. Conventional scanning electron microscope is used as a fabrication tool for electron beam lithography. Optical microscope and energy dispersive spectroscopy (EDS) have been used for its morphological and elemental characterization. Optical characterization is performed by UV-Vis absorption spectroscopic technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new apparatus for electron tomography in the scanning electron microscope

The three-dimensional reconstruction of a microscopic specimen has been obtained by applying the tomographic algorithm to a set of images acquired in a Scanning Electron Microscope. This result was achieved starting from a series of projections obtained by stepwise rotating the sample under the beam raster. The Scanning Electron Microscope was operated in the scanning-transmission imaging mode, where the intensity of the transmitted electron beam is a monotonic function of the local mass-density and thickness of the specimen. The detection strategy has been implemented and tailored in order to maintain the projection requirement over the large tilt range, as required by the tomographic workflow. A Si-based electron detector and an eucentric-rotation specimen holder have been specifically developed for the purpose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of large area plasmonic nanoparticle grating structure on silver halide based transmission electron microscope film and its application as a surface enhanced Raman spectroscopy substrate

The plasmonic responses of silver nanoparticle grating structures of different periods made on silver halide based electron microscope film are investigated. Raster scan of the conventional scanning electron microscope (SEM) is used to carry out electron beam lithography for fabricating the plasmonic nanoparticle grating (PNG) structures. Morphological characterization of the PNG structures, carried out by the SEM and the atomic force microscope, indicates that the depth of the groove decreases with a decrease in the grating period. Elemental characterization performed by the energy dispersive spectroscopy and the x-ray diffraction shows the presence of nanoparticles of silver in the PNG grating. The optical characterization of the gratings shows that the localized surface plasmon resonance peak shifts from 366 to 378 nm and broadens with a decrease in grating period from 10 to 2.5 μm. The surface enhanced Raman spectroscopy of the Rhodamine-6G dye coated PNG structure shows the maximum enhancement by two orders of magnitude in comparison to the randomly distributed silver nanoparticles having similar size and shape as the PNG structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of process-induced damage in Cu/low-k interconnect structure by microscopic infrared spectroscopy with polarized infrared light

Microscopic Fourier-transform infrared (FT-IR) spectra are measured for a Cu/low-k interconnect structure using polarized IR light for different widths of low-k spaces and Cu lines, and for different heights of Cu lines, on Si substrates. Although the widths of the Cu line and the low-k space are 70 nm each, considerably smaller than the wavelength of the IR light, the FT-IR spectra of the low-k film were obtained for the Cu/low-k interconnect structure. A suitable method was established for measuring the process-induced damage in a low-k film that was not detected by the TEM-EELS (Transmission Electron Microscope-Electron Energy-Loss Spectroscopy) using microscopic IR polarized light. Based on the IR results, it was presumed that the FT-IR spectra mainly reflect the structural changes in the sidewalls of the low-k films for Cu/low-k interconnect structures, and the mechanism of generating process-induced damage involves the generation of Si-OH groups in the low-k film when the Si-CH{sub 3} bonds break during the fabrication processes. The Si-OH groups attract moisture and the OH peak intensity increases. It was concluded that the increase in the OH groups in the low-k film is a sensitive indicator of low-k damage. We achieved the characterization of the process-induced damage that was not detected by the TEM-EELS and speculated that the proposed method is applicable to interconnects with line and space widths of 70 nm/70 nm and on shorter scales of leading edge devices. The location of process-induced damage and its mechanism for the Cu/low-k interconnect structure were revealed via the measurement method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A framed, 16-image Kirkpatrick–Baez x-ray microscope

A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2- to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an ultrafast wide-field microscope for single-shot laser-driven shock and ablation studies

We build an ultrafast wide-field microscope that captures single-shot events at near-optical diffraction limit for time-resolved studies of ablation and shock compression. Here, we provide insights on how the imaging and spectroscopic modalities of our single-shot microscope are impacted by the depth of field of a microscope objective. At high spatial resolution, the depth of field can critically impede these experiments and novel strategies must be implemented to acquire high-quality optical micrographs at high throughput. Here, we highlight how custom lithography-prepared samples enable us to rectify optical artifacts that arise during sample motion. With a complete knowledge of how the mechanical and optical components couple together, we can then extract critical spatial and temporal features of our ablation and shock compression experiments. For example, during the ablation processes, we show that shock waves created in metal thin films form Newton’s interference rings, whose evolution can be recorded with picosecond temporal resolution and at near optical diffraction-limit resolution.

Ultrafast microscopy↗

Microscopic dynamics underlying the stress relaxation of arrested soft materials

Arrested soft materials such as gels and glasses exhibit a slow stress relaxation with a broad distribution of relaxation times in response to linear mechanical perturbations. Although this macroscopic stress relaxation is an essential feature in the application of arrested systems as structural materials, consumer products, foods, and biological materials, the microscopic origins of this relaxation remain poorly understood. Here, we elucidate the microscopic dynamics underlying the stress relaxation of such arrested soft materials under both quiescent and mechanically perturbed conditions through X-ray photon correlation spectroscopy. By studying the dynamics of a model associative gel system that undergoes dynamical arrest in the absence of aging effects, we show that the mean stress relaxation time measured from linear rheometry is directly correlated to the quiescent superdiffusive dynamics of the microscopic clusters, which are governed by a buildup of internal stresses during arrest. We also show that perturbing the system via small mechanical deformations can result in large intermittent fluctuations in the form of avalanches, which give rise to a broad non-Gaussian spectrum of relaxation modes at short times that is observed in stress relaxation measurements. These findings suggest that the linear viscoelastic stress relaxation in arrested soft materials may be governed by nonlinear phenomena involving an interplay of internal stress relaxations and perturbation-induced intermittent avalanches.

36 MATERIALS SCIENCE↗

Microscopic description of dissipative dynamics of a level-crossing transition

We analyze the effect of a dissipative bosonic environment on the Landau-Zener-Stueckelberg-Majorana (LZSM) level crossing model by using a microscopic approach to derive the relevant master equation. For an environment at zero temperature and weak dissipation, our microscopic approach confirms the independence of the survival probability on the decay rate that has been predicted earlier by the simple phenomenological LZSM model. For strong decay the microscopic approach predicts a notable increase of the survival probability, which signals dynamical decoupling of the initial state. Unlike the phenomenological model, our approach makes it possible to study the dependence of the system dynamics on the temperature of the environment. In the limit of very high temperature we find that the dynamics is characterized by a very strong dynamical decoupling of the initial state--the temperature-induced quantum Zeno effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic model versus systematic low-energy effective field theory for a doped quantum ferromagnet

We consider a microscopic model for a doped quantum ferromagnet as a test case for the systematic low-energy effective field theory for magnons and holes, which is constructed in complete analogy to the case of quantum antiferromagnets. In contrast to antiferromagnets, for which the effective field theory approach can be tested only numerically, in the ferromagnetic case, both the microscopic and the effective theory can be solved analytically. In this way, the low-energy parameters of the effective theory are determined exactly by matching to the underlying microscopic model. The low-energy behavior at half-filling as well as in the single- and two-hole sectors is described exactly by the systematic low-energy effective field theory. In particular, for weakly bound two-hole states the effective field theory even works beyond perturbation theory. This lends strong support to the quantitative success of the systematic low-energy effective field theory method not only in the ferromagnetic but also in the physically most interesting antiferromagnetic case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rotation and shape changes in {sup 151}Tb and {sup 196}Pb: Probes of nuclear structure and tunneling process in warm nuclei. II. Microscopic Monte Carlo simulation

A Monte Carlo simulation of the {gamma} decay of superdeformed nuclei has been developed. It is based on microscopic calculations for the energy levels, E2 decay probabilities, collective mass parameters, and potential energy barriers. The use of microscopically calculated quantities largely reduces the parameters of the simulation, allowing one to focus on the basic ingredients of the physical processes. Calculations are performed for the warm rotating superdeformed nuclei {sup 151}Tb and {sup 196}Pb, for which high statistics Euroball IV data are available. The dependence on the simulation parameters is investigated, together with the basic features of the microscopic calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{sup 6}He+{sup 12}C elastic scattering using a microscopic optical potential

The {sup 6}He+{sup 12}C elastic scattering data at beam energies of 3,38.3, and 41.6 MeV/nucleon are studied utilizing the microscopic optical potentials obtained by a double-folding procedure and also by using those inherent in the high-energy approximation. The calculated optical potentials are based on the neutron and proton density distributions of colliding nuclei established in an appropriate model for {sup 6}He and obtained from the electron scattering form factors for {sup 12}C. The depths of the real and imaginary parts of the microscopic optical potentials are considered as fitting parameters. At low energy the volume optical potentials reproduce sufficiently well the experimental data. At higher energies, generally, additional surface terms having the form of a derivative of the imaginary part of the microscopic optical potential are needed. The problem of ambiguity of adjusted optical potentials is resolved requiring the respective volume integrals to obey the determined dependence on the collision energy. Estimations of the Pauli blocking effects on the optical potentials and cross sections are also given and discussed. Conclusions on the role of the aforesaid effects and on the mechanism of the considered processes are made.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved microscopic-macroscopic approach incorporating the effects of continuum states

The Woods-Saxon-Strutinsky method (the microscopic-macroscopic method) combined with the Kruppa prescription for positive-energy levels, which is necessary to treat neutron-rich nuclei, is studied to clarify the reason for its success and to propose improvements for its shortcomings. The reason why the plateau condition is met for the Nilsson model but not for the Woods-Saxon model is understood in a new interpretation of the Strutinsky smoothing procedure as a low-pass filter. Essential features of the Kruppa level density is extracted in terms of the Thomas-Fermi approximation modified to describe spectra obtained from diagonalization in truncated oscillator bases. A method is proposed, which weakens the dependence on the smoothing width by applying the Strutinsky smoothing only to the deviations from a reference level density. The BCS equations are modified for the Kruppa spectrum, which is necessary to treat the pairing correlation properly in the presence of a continuum. The potential depth is adjusted for the consistency between the microscopic and macroscopic Fermi energies. It is shown, with these improvements, that the microscopic-macroscopic method is now capable to reliably calculate binding energies of nuclei far from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic description of proton scattering at 295 MeV from Pb isotopes

Microscopic analysis of the recently reported 295-MeV-proton scattering data from Pb isotopes and {sup 58}Ni is presented within the framework of the Brueckner-Hartree-Fock theory. The effective interaction (g matrix) has been calculated using three Hamiltonians with Urbana v-14, Argonne v-18, and Ried93 internucleon potentials. The microscopic optical potential is calculated by folding the effective interactions over nucleon density distributions obtained in the relativistic mean field framework. The Argonne v-18 and Ried93 interactions have been used for the first time to calculate the nucleon-nucleus optical potential. The calculations reproduce the experiment well thus revalidating the use of microscopic optical potential in such analyses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear shape evolution based on microscopic level densities

Here, by combining microscopically calculated level densities with the Metropolis walk method, we develop a consistent framework for treating the energy and angular-momentum dependence of the nuclear shape evolution in the fission process. For each nucleus under consideration, the level density is calculated microscopically for each of more than five million shapes with a recently developed combinatorial method. The method employs the same single-particle levels as those used for the extraction of the pairing and shell contributions to the macroscopic-microscopic deformation-energy surface. Containing no new parameters, the treatment is suitable for elucidating the energy dependence of the dynamics of warm nuclei on pairing and shell effects. It is illustrated for the fission fragment mass distribution for several uranium and plutonium isotopes of particular interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic core-quasiparticle coupling model for spectroscopy of odd-mass nuclei

Predictions of the spectroscopic properties of low-lying states are critical for nuclear structure studies but are problematic for nuclei with an odd nucleon due to the interplay of the unpaired single particle with nuclear collective degrees of freedom. To predict the spectroscopic properties of odd-mass medium-heavy and heavy nuclei with a model that treats single-particle and collective degrees of freedom within the same microscopic framework. A microscopic core-quasiparticle coupling (CQC) model based on the covariant density functional theory is developed that contains the collective excitations of even-mass cores and spherical single-particle states of the odd nucleon as calculated from a quadrupole collective Hamiltonian combined with a constrained triaxial relativistic Hartree-Bogoliubov model. Additionally, predictions of the new model for excitation energies, kinematic and dynamic moments of inertia, and transition rates are shown to be in good agreement with results of low-lying spectroscopy measurements of the axially deformed odd-proton nucleus 159 Tb and the odd-neutron nucleus 157 Gd. A microscopic CQC model based on covariant density functional theory is developed for odd-mass nuclei and shown to give predictions that agree with measurements of two medium-heavy nuclei. Future studies with additional nuclei are planned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗