Search NASA⌕ Search

SEARCH · Search NASA

Results for “microwave spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Visualization, Analysis and Subsetting Tools for EOS Aura Data Products in HDF-EOS5

Aura data products are among the first to use the new version 5 of the Hierarchical Data Format for the Earth Observing System, or HDF-EOS5. This presentation discusses the common HDF-EOS5 file layout that is adopted for most of the EOS Aura standard data products. Details of the various tools that can be used to access, visualize and subset these data will also be provided. Aura, the NASA Earth Observing System's atmospheric chemistry mission, was successfully launched July 15, 2004. The Aura spacecraft includes four instruments: the High Resolution Dynamics Limb Sounder (HIRDLS), the Microwave Limb Sounder (MLS), the Ozone Monitoring Instrument (OMI), and the Tropospheric Emission Spectrometer (TES). Data from the HIRDLS, MLS and OMI will be archived at the NASA Goddard Earth Sciences (GES) Distributed Active Archive Center (DAAC), while TES data will be archived at the NASA Langley Research Center DAAC. For more information see http://daac.gsfc.nasa.gov/.

Johnson, J.↗

Learning from GES DISC's MLS and OMI Data Users: Metrics Matter

It has been over 15 years since Aura research satellite launched in 2004 to observe the Earth's ozone layer, air quality, and climate from four different instruments - the High Resolution Dynamics Limb Sounder (HIRDLS), the Microwave Limb Sounder (MLS), the Ozone Monitoring Instrument (OMI), and the Tropospheric Emission Spectrometer (TES). Observations from the Aura mission have established a concrete understanding of the changing chemistry of our atmosphere.The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) is the official archive and distribution center for the HIRDLS, MLS, and OMI instruments. This presentation will report metrics of data usage and services on these instruments. Key to GES DISC's mission to provide better data support is gaining a better understanding of our users' needs and behaviors as they discover, access and utilize these data. We will summarize the users' needs from these instruments based on user inquiry information collected over the Aura mission lifetime and present findings from this ensemble metrics.

Metrics↗

Faster Tropical Upper Stratospheric Upwelling is Driving Changes in Ozone Chemistry

Trends in N2O and the chlorofluorocarbons (CFCs) cause trends in O3 through changes in their reactive product gases, NOx and ClOx, but transport plays an important role because it controls the distribution of the long‐lived source gases that produce ozone‐destroying radicals. In this study we show that increased tropical upwelling 10‐5 hPa from 2013‐2021 has changed upper stratospheric (UpS) composition and shifted the balance of O3 loss processes. We use N2O, HNO3, NOx, temperature and O3 data from the Aura Microwave Limb Sounder (MLS) and the SCI‐Sat Atmospheric Chemistry Experiment Fourier Transport Spectrometer (ACE‐FTS) over a 16‐year period to show how changes in reactive nitrogen species affected gas phase ozone chemistry above 30 hPa between June 2013‐May 2021 compared to the previous 8 years, June 2005‐May 2013. We use 2 simulations of the Global Modeling Initiative (GMI) chemistry transport model (CTM), with and without time varying MERRA2 meteorology, to understand how dynamical changes during this 16‐yr period affected O3 through changes in loss via the NOx and ClOx cycles. We also identify the role that the quasi‐biennial oscillation (QBO) in tropical zonal winds plays in the UpS composition changes. We find large increases in tropical upwelling and poleward transport in the northern branch of the UpS transport circulation since 2013 that dramatically increased the abundance of the N2O and its odd nitrogen product gases, NOx and HNO3. O3 loss by NOx in the Arctic UpS increased due to dynamically driven composition change, explaining the observed weak O3 recovery in that region since 2005. The increased upwelling also drove decreases in tropical NOx, leading to increased tropical O3 from 12‐6 hPa.

middle atmosphere chemistry and composition↗

Solid state microwave electronics

The research for improving the resolution and stability in the CEC 21-110 double-focusing mass spectrometer is reported. The types of experiments beyond the performance capability of the present instrument are given, and a control system that introduces changes in the magnetic field to maintain the position of a given mass peak is described for stabilizing the instrument.

Penfield, P. L., Jr.↗

Infrared and millimeter wave techniques for the Cosmic Background Explorer Satellite

The Cosmic Background Explorer Satellite will employ infrared and microwave techniques to gain information about the very early universe. Three instruments will cover the spectral range from 8 microns to 13 mm, determining both the spectrum and angular distribution of the large scale background radiation fields. A cryogenic polarizing Michelson interferometric spectrometer will measure the spectrum of the 3 deg K relic radiation from the big bang with precision. Four differential microwave radiometers will map the sky from 23 to 90 GHz in a search for anisotropy of the universe. A broadband cryogenic IR photometer will map zodiacal dust emission, galactic dust, and an extragalactic residual component.

Mather, J. C.↗

Broad-Bandwidth FPGA-Based Digital Polyphase Spectrometer

With present concern for ecological sustainability ever increasing, it is desirable to model the composition of Earth s upper atmosphere accurately with regards to certain helpful and harmful chemicals, such as greenhouse gases and ozone. The microwave limb sounder (MLS) is an instrument designed to map the global day-to-day concentrations of key atmospheric constituents continuously. One important component in MLS is the spectrometer, which processes the raw data provided by the receivers into frequency-domain information that cannot only be transmitted more efficiently, but also processed directly once received. The present-generation spectrometer is fully analog. The goal is to include a fully digital spectrometer in the next-generation sensor. In a digital spectrometer, incoming analog data must be converted into a digital format, processed through a Fourier transform, and finally accumulated to reduce the impact of input noise. While the final design will be placed on an application specific integrated circuit (ASIC), the building of these chips is prohibitively expensive. To that end, this design was constructed on a field-programmable gate array (FPGA). A family of state-of-the-art digital Fourier transform spectrometers has been developed, with a combination of high bandwidth and fine resolution. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved analog-to-digital converters (ADCs). This 6-Gsps (gigasample per second) digital representation of the analog signal is then processed through an FPGA-based streaming fast Fourier transform (FFT). Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers.

Jamot, Robert F.↗

Microwave and hard X-ray observations of a solar flare with a time resolution of better than 100 MS

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-Ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Observatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model.

Kaufmann, P.↗

Microwave and hard X-ray observations of a solar flare with a time resolution better than 100 ms

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Obervatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240 ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model. Previously announced in STAR as N82-30215

Kaufmann, P.↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Simple waveguide reflection maser with broad tunability

The design and performance of a simple two-stage reflection maser for use between 9 and 10 GHz are described. The maser is used to improve the sensitivity of a transmission electron spin resonance spectrometer. A ruby-filled waveguide structure permits broad tunability and straightforward construction. All microwave components except the ruby section are at room temperature.

Flesner, L. D.↗

The Berkeley tunable far infrared laser spectrometers

A detailed description is presented for a tunable far infrared laser spectrometer based on frequency mixing of an optically pumped molecular gas laser with tunable microwave radiation in a Schottky point contact diode. The system has been operated on over 30 laser lines in the range 10-100/cm and exhibits a maximum absorption sensitivity near one part in a million. Each laser line can be tuned by + or - 110 GHz with first-order sidebands.

Blake, G. A.↗

In situ amplification of spin echoes within a kinetic inductance parametric amplifier

The use of superconducting microresonators together with quantum-limited Josephson parametric amplifiers has enhanced the sensitivity of pulsed electron spin resonance (ESR) measurements by more than four orders of magnitude. So far, the microwave resonators and amplifiers have been designed as separate components due to the incompatibility of Josephson junction–based devices with magnetic fields. This has produced complex spectrometers and raised technical barriers toward adoption of the technique. Here, we circumvent this issue by coupling an ensemble of spins directly to a weakly nonlinear and magnetic field–resilient superconducting microwave resonator. We perform pulsed ESR measurements with a 1-pL mode volume containing 6 × 10 7 spins and amplify the resulting signals within the device. When considering only those spins that contribute to the detected signals, we find a sensitivity of 2.8 x 10 3 spins / $\sqrt{Hz}$ for a Hahn echo sequence at a temperature of 400 mK. In situ amplification is demonstrated at fields up to 254 mT, highlighting the technique’s potential for application under conventional ESR operating conditions.

42 ENGINEERING↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

A study of flare buildup from simultaneous observations in microwave, H-alpha, and UV wavelengths

The results of high-resolution observations of the solar preflare activity of June 25, 1980 are analyzed. The observations were carried out simultaneously in the UV microwave, and H-alpha wavelengths using the VLA, the Ottawa River photoheliograph, and the Solar Max spectrometer and polarimeter instruments. Increases were observed in the intensitiy and polarization of compact sources at a wavelength of 6-cm during the preflare hour. The increases were associated with rising and twisting motions in the magnetic loops near the sight of the subsequent flare. Consistent with this process, analysis of the transverse and Doppler motions observed in the H-alpha filament before disruption showed that the filament was activated internally by the motions of evolving magnetic flux patterns. Ultraviolet data for C IV brightenings and upflows at the first appearance of the H-alpha filament indicated the presence of rising magnetic loops and material rising within the loops. The complete VLA, microwave and H-alpha data sets are given.

Kundu, M. R.↗

Evidence for beamed electrons in a limb X-ray flare observed by Hard X-Ray Imaging Spectrometer (HXIS)

The limb flare of November 18, 1980, 14:51 UT, was investigated on the basis of X-ray images taken by the Hard X-ray Imaging Spectrometer (HXIS) and of X-ray spectra from the Hard X-Ray Burst Spectrometer (HXRBS) aboard the Solar Maximum Mission (SMM). The impulsive burst was also recorded at microwave frequencies between 2 and 20 GHz whereas no optical flare and no radio event at frequencies below 1 GHz were reported. The flare occurred directly at the SW limb of the solar disk. Taking advantage of the spatial resolution of HXIS images, the time evolution of the X-radiation originating from relatively small source regions can be studied. Using Monte Carlo computations of the energy distribution of energetic electrons traversing the solar plasma, the bremsstrahlung spectra produced by the electrons were derived.

Haug, Eberhard↗

Geologic mapping in Death Valley, California/Nevada using NASA/JPL airborne systems (AVIRIS, TIMS, and AIRSAR)

A multi-sensor aircraft campaign called the Geologic Remote Sensing Field Experiment (GRSFE) conducted during 1989 resulted in acquisition of high quality multispectral images in the visible, near infrared, shortwave infrared, thermal infrared, and microwave regions of the electromagnetic spectrum. The airborne data sets include the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), the Thermal Infrared Multispectral Scanner (TIMS), and the Airborne Synthetic Aperture Radar (SAR). Ancillary data include Landsat Thematic Mapper, laboratory and field spectral measurements, and traditional geologic mapping. The GRSFE data for a site in the northern Death Valley, (California and Nevada) region were calibrated to physical units and geometrically registered to a map base. Various aspects of this experiment are briefly discussed.

Kruse, Fred A.↗

Evidence for Highly Inhomogeneous mm-Wave Sources During the Impulsive Flare of May 9, 1991

In this paper multiwavelength observations of an impulsive flare of May 9, 1991 are presented. This event was observed with the 48 GHz multibeam focal array used at the Itapetinga radio telescope, the microwave patrol telescopes at Bem and the BATSE high time resolution hard X-ray spectrometer on board CGRO. While spatially unresolved low sensitivity observations show two major impulsive peaks, the mm-wave observations with the ability of spatially high resolved tracking of the emission centroids suggest a primarily bipolar source configuration. For the first time two mm-wave sources with a spacing below the HPBW could be separated with the multibeam technique. The general features of the observations are explained as emission of partially trapped electrons. Furthermore we present evidence for highly inhomogeneous substructures within one of the two mm-wave sources for which the positional scatter of the emission center, within 2s, is less than 2".

Hermann, R.↗