Grout testing to support tank closure at the Savannah River Site - 15370
Final operational closure of the Savannah River Site (SRS) waste tanks is performed by filling the voids inside the tanks with a series of tailored grout formulas thereby stabilizing the remaining residuals. These tailored grout formulas were each developed to meet the demands of the closure process. The needs identified for the closure process include (1) a flowable, self-consolidating, reducing grout for tank fill, (2) a highly flowable grout capable of filling the 7-1/4 kilometers (4-1/2 miles) of 5-centimeter (2-inch) diameter cooling coils inside the tank, and (3) a highly flowable grout capable of filling equipment remaining in the tank. The specific characteristics of each of the grout formulations were tested to ensure they would function as required during implementation. Performance testing was also done on some of the grout formulations to confirm mix effectiveness and improve worker handling proficiency and conducted additional testing on the bulk fill grout to expand the placement capabilities of the grout. This paper focuses on the evolution of the closure process' identified needs, formulation development, and the subsequent testing of the tailored grout formulations utilized in the past tank closure processes at SRS. (authors)