Search NASA⌕ Search

SEARCH · Search NASA

Results for “monitored quantum systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Laser-Induced Dynamical Chirality and Intramolecular Energy Flow in the CH Chromophore

We review the quantum dynamics of intramolecular energy flow during and after coherent infrared multiphoton excitation of the CH organic chromophore. The understanding of the underlying dynamics is of central importance for a wide range of systems in molecular physics, chemistry and biology, due to the experimentally supported assumption that the chromophore dynamics is weakly-dependent on a specific environment, in particular on sub-picosecond time scale. The excitation process due to the interaction with the laser field is studied by computationally monitoring the wave packet motion in the configuration sub-space relevant to femtosecond dynamics, using global analytical potential energy and electric dipole functions previously developed. The features of the intramolecular vibrational energy redistribution and the related dynamical time scales are investigated. In particular, we discuss the generation of dynamical chirality in methane istopomers, the corresponding stereomutation and racemization phenomena on the femtosecond time scale, and their relation to intramolecular vibrational energy redistribution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thematic Mapper Image Processing System (TIPS) Processing Status

Radiometric and geometric correction performance is considered. A one quantum level requirement was met in all spectral bands with an occasional band 7 exception. Initial post launch calibration was accomplished. An absolute radiometric calibration is in progress including an investigation of low impact solution to scan striping. Initial and three downstream updates as well as coordination with LANDSAT D' instrument calibration are planned. Methods and problems in measuring geometric correction performance are examined with an emphasis on temporal registration, geodetic registrtion, and the modeling error budget. Planned efforts include eliminating band 2, band 5 chips; continued performance monitoring; calibration of profile, misalignment angles, and filer parameters; studying the need for seasonal geodetic control points; and improvement of the subpixel correlation technique.

Brooks, J.↗

Uncovering the Role of Hole Traps in Promoting Hole Transfer from Multiexcitonic Quantum Dots to Molecular Acceptors

The understanding of electronic dynamics in multiexcitonic quantum dots (QDs) is important for designing efficient systems useful in high power scenarios, such as solar concentrators and multielectron charge transfer. The multiple charge carriers within a QD can undergo undesired Auger recombination events, which rapidly annihilate carriers on picosecond time scales and generate heat from absorbed photons instead of useful work. Compared to the transfer of multiple electrons, the transfer of multiple holes has proven to be more difficult due to slower hole transfer rates. To probe the competition between Auger recombination and hole transfer in CdSe, CdS, and CdSe/CdS QDs of varying sizes, we synthesized a phenothiazine derivative with optimized functionalities for binding to QDs as a hole accepting ligand and for spectroscopic observation of hole transfer. Transient absorption spectroscopy was used to monitor the photoinduced absorption features from both trapped holes and oxidized ligands under excitation fluences where the averaged initial number of excitons in a QD ranged from ~1 to 19. We observed fluence-dependent hole transfer kinetics that last around 100 ps longer than the predicted Auger recombination lifetimes, and the transfer of up to 3 holes per QD. Theoretical modeling of the kinetics suggests that binding of hole acceptors introduces trapping states significantly different from those in native QDs passivated with oleate ligands. Holes in these modified trap states have prolonged lifetimes, which promotes the hole transfer efficiency. These results highlight the beneficial role of hole-trapping states in devising hole transfer pathways in QD-based systems under multiexcitonic conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Color center in β -Ga 2 O 3 emitting at the telecom range

Transition metal (TM) ions incorporated into a host from a wide bandgap semiconductor are recognized as a promising system for quantum technologies with enormous potential. In this work, we report on a TM color center in β-Ga 2 O 3 with physical properties attractive for quantum information applications. The center is found to emit at 1.316 μm and exhibits weak coupling to phonons, with optically addressable higher-lying excited states, beneficial for single-photon emission within the telecom range (O-band). Using magneto-photoluminescence (PL) complemented by time-resolved PL measurements, we identify the monitored emission to be internal 1 E→ 3 A 2 spin-forbidden transitions of a 3d 8 TM ion with a spin-triplet ground state—a possible candidate for a spin qubit. We tentatively attribute this color center to a complex involving a sixfold coordinated Cu 3+ ion.

36 MATERIALS SCIENCE↗

Using stochastic activity networks to study the energy feasibility of automatic weather stations

Automatic Weather Stations (AWSs) are systems equipped with a number of environmental sensors and communication interfaces used to monitor harsh environments, such as glaciers and deserts. Designing such systems is challenging, since designers have to maximize the amount of sampled and transmitted data while considering the energy needs of the system that, in most cases, is powered by rechargeable batteries and exploits energy harvesting, e.g., solar cells and wind turbines. To support designers of AWSs in the definition of the software tasks and of the hardware configuration of the AWS we designed and implemented an energy-aware simulator of such systems. The simulator relies on the Stochastic Activity Networks (SANs) formalism and has been developed using the Möbius tool. In this paper we first show how we used the SAN formalism to model the various components of an AWS, we then report results from an experiment carried out to validate the simulator against a real-world AWS and we finally show some examples of usage of the proposed simulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of atomic radical monitoring probe and its application to spatial distribution measurements of H and O atomic radical densities in radical-based plasma processing

Atomic radicals such as hydrogen (H) and oxygen (O) play important roles in process plasmas. In a previous study, we developed a system for measuring the absolute density of H, O, nitrogen, and carbon atoms in plasmas using vacuum ultraviolet absorption spectroscopy (VUVAS) with a compact light source using an atmospheric pressure microplasma [microdischarge hollow cathode lamp (MHCL)]. In this study, we developed a monitoring probe for atomic radicals employing the VUVAS with the MHCL. The probe size was 2.7 mm in diameter. Using this probe, only a single port needs to be accessed for radical density measurements. We successfully measured the spatial distribution of the absolute densities of H and O atomic radicals in a radical-based plasma processing system by moving the probe along the radial direction of the chamber. This probe allows convenient analysis of atomic radical densities to be carried out for any type of process plasma at any time. We refer to this probe as a ubiquitous monitoring probe for atomic radicals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, October 2006

Topics covered include: Protein Sensors Based on Optical Ring Resonators; Phase Sensor for Aligning a Segmented Telescope Mirror; Control Software for Advanced Video Guidance Sensor; Generating Control Commands From Gestures Sensed by EMG; Multiple-Flat-Panel System Displays Multidimensional Data; 3D X-Ray Luggage-Screening System; Probe Station and Near-Field Scanner for Testing Antennas; Photodetector Arrays for Multicolor Visible/Infrared Imaging; Semiconductor Bolometers Give Background-Limited Performance; Multichannel X-Band Dielectric-Resonator Oscillator; Automatic Alignment of Displacement-Measuring Interferometer; Earth Observing System Data Gateway; Power User Interface; Mercury Shopping Cart Interface; Cassini Archive Tracking System; Architecture Adaptive Computing Environment; Computing Fault Displacements from Surface Deformations; Oxygen-Permeable, Hydrophobic Membranes of Silanized alpha-Al2O3; SiC Composite Turbine Vanes; Retaining Device for the Interior Structure of a Spacecraft Payload; Tool for Torquing Circular Electrical-Connector Collars; System for Continuous Deaeration of Hydraulic Oil; Solar-Powered Cooler and Heater for an Automobile Interior; Improved Oxygen-Beam Texturing of Glucose-Monitoring Optics; Tool for Two Types of Friction Stir Welding; Stationary Apparatus Would Apply Forces of Walking to Feet; Instrument Would Detect and Collect Biological Aerosols; Boundary Condition for Modeling Semiconductor Nanostructures; Miniature Distillation Column for Producing LOX From Air; Even Illumination from Fiber-Optic-Coupled Laser Diodes; Optically Driven Deformable Mirrors; Algorithm for Automated Detection of Edges of Clouds; Exploiting Quantum Resonance to Solve Combinatorial Problems; Hybrid Terrain Database; On Release of Microbe-Laden Particles from Mars Landers; A Concept for Run-Time Support of the Chapel Language; Thermoelectric Inhomogeneities in (Ag(sub 1-y)SbTe2)(sub x)(PbTe)(sub 1-x); and Spacecraft Escape Capsule.

Source record↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of spatially nonuniform gain on lasing modes in weakly scattering random systems

A study on the effects of optical gain nonuniformly distributed in one-dimensional random systems is presented. It is demonstrated numerically that even without gain saturation and mode competition, the spatial nonuniformity of gain can cause dramatic and complicated changes to lasing modes. Lasing modes are decomposed in terms of the quasimodes of the passive system to monitor the changes. As the gain distribution changes gradually from uniform to nonuniform, the amount of mode mixing increases. Furthermore, we investigate new lasing modes created by nonuniform gain distributions. We find that new lasing modes may disappear together with existing lasing modes, thereby causing fluctuations in the local density of lasing states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonclassical Velocity Statistics in a Turbulent Atomic Bose-Einstein Condensate

In a recent experiment Paoletti et al. [Phys. Rev. Lett. 101, 154501 (2008)] monitored the motion of tracer particles in turbulent superfluid helium and inferred that the velocity components do not obey the Gaussian statistics observed in ordinary turbulence. Motivated by their experiment, we create a small 3D turbulent state in an atomic Bose-Einstein condensate, compute directly the velocity field, and find similar nonclassical power-law tails. We obtain similar results in 2D trapped and 3D homogeneous condensates, and in classical 2D vortex points systems. This suggests that non-Gaussian turbulent velocity statistics describe a fundamental property of quantum turbulence. We also track the decay of the vortex tangle in the presence of the thermal cloud.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum nondemolition measurements - Comment on recent developments

The limitations of the detectability of extremely weak signals (gravitational radiation for instance) imposed by Heisenberg's uncertainty principle on the sequential determination of those signals have been explored recently. A variety of schemes have been proposed to circumvent these limitations. Although all of the earlier attempts have been proven fruitless a recent proposal seems to be quite promising. The scheme, consisting of two harmonic oscillators interacting with each other in a peculiar way, allows for an exact analytical solution which is derived here. If it can be assumed that the expectation value of one of the canonical variables of the total system suffices to monitor the weak signal it can be shown that, in the absence of thermal noise, arbitrarily weak signals can in principle be measured without interference from the uncertainty principle.

Von Roos, O.↗

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

System and methods to determine and monitor changes in microstructural properties

A system and methods with which changes in microstructure properties such as grain size, grain elongation, texture, and porosity of materials can be determined and monitored over time to assess conditions such as stress and defects. An example system includes a number of ultrasonic transducers configured to transmit ultrasonic waves towards a target region on a specimen, a voltage source configured to excite the first and second ultrasonic transducers, and a processor configured to determine one or more properties of the specimen.

36 MATERIALS SCIENCE↗

Non-invasive in situ plasma monitoring of reactive gases using the floating harmonic method for inductively coupled plasma etching application

The floating harmonic method was developed for in situ plasma diagnostics of allowing real time measurement of electron temperature (T{sub e}) and ion flux (J{sub ion}) without contamination of the probe from surface modification by reactive species. In this study, this novel non-invasive diagnostic system was studied to characterize inductively coupled plasma of reactive gases monitoring T{sub e} and J{sub ion} for investigating the optimum plasma etching conditions and controlling of the real-time plasma surface reaction in the range of 200-900 W source power, 10-100 W bias power, and 3-15 mTorr chamber pressure, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optically induced changes in the band structure of the Weyl charge-density-wave compound (TaSe 4 ) 2 I

Collective modes are responsible for the emergence of novel quantum phases in topological materials. In the quasi-one dimensional (1D) Weyl semimetal (TaSe 4 ) 2 I , a charge density wave (CDW) opens band gaps at the Weyl points, thus turning the system into an axionic insulator. Melting the CDW would restore the Weyl phase, but 1D fluctuations extend the gapped regime far above the 3D transition temperature (T CDW = 263 K), thus preventing the investigation of this topological phase transition with conventional spectroscopic methods. Here we use a non-equilibrium approach: we perturb the CDW phase by photoexcitation, and we monitor the dynamical evolution of the band structure by time- and angle-resolved photoelectron spectroscopy. We find that, upon optical excitation, electrons populate the linearly dispersing states at the Fermi level (E F ), and fill the CDW gap. The dynamics of both the charge carrier population and the band gap renormalization (BGR) show a fast component with a characteristic time scale of a few hundreds femtoseconds. However, the BGR also exhibits a second slow component on the µs time scale. The combination of an ultrafast response and of persistent changes in the spectral weight at E$_\mathrm{F}$, and the resulting sensitivity of the linearly dispersing states to optical excitations, may explain the high performances of (TaSe 4 ) 2 I as a material for broadband infrared photodetectors.

36 MATERIALS SCIENCE↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗