Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

In situ determination of the static inductance and resistance of a plasma focus capacitor bank

The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L{sub 0}, and resistance r{sub 0} to be obtained using lightly damped sinusoid equations given the bank capacitance C{sub 0}. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peer Review of "Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions," Antoun, et al, 2011 Monitoring Research Review

The following is primarily a review of 'Analysis and Simulation of Near-Field Wave Motion Data from the Source Physics Experiment Explosions,' Antoun, et al, published by Lawrence Livermore National Laboratory (LLNL) after SPE-1 in 2011 (Ref. 1). However, LLNL analysis of SPE-2 (Ref. 2) will also be discussed. A review by Los Alamos National Laboratory (LANL) personnel of Reference 1 finds both the evidence of the effects of joints on the data and the correlation of calculations with the data weak. This conclusion is made on three separate levels: (1) Fundamental observations made of the various referenced figures taken as presented; (2) Observations made following corrections to errors and omissions to the selected data; and (3) Observations made after considering likely errors in the raw data set. The evidence presented in the referenced papers relies on subjective interpretation of various figures. This is the nature of this technical field of study and, indeed, much of our observation is also subjective.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Inertia driven radial breathing and nonlinear relaxation in cylindrically confined pure electron plasma

The dynamics of cylindrically trapped electron plasma has been investigated using a newly developed 2D Electrostatic PIC code that uses unapproximated, mass-included equations of motion for simulation. Exhaustive simulations, covering the entire range of Brillouin ratio, were performed for uniformly filled circular profiles in rigid rotor equilibrium. The same profiles were then loaded away from equilibrium with an initial value of rigid rotation frequency different from that required for radial force balance. Both these sets of simulations were performed for an initial zero-temperature or cold load of the plasma with no spread in either angular velocity or radial velocity. The evolution of the off-equilibrium initial conditions to a steady state involve radial breathing of the profile that scales in amplitude and algebraic growth with Brillouin fraction. For higher Brillouin fractions, the growth of the breathing mode is followed by complex dynamics of spontaneous hollow density structures, excitation of poloidal modes, leading to a monotonically falling density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-163: Evaluation of Dose Distributions Recalculated with Per-Field Measurement Data Under the Condition of Respiratory Motion During IMRT for Liver Cancer

Purpose: The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. Methods: The 4DCT data for 10 patients who had been treated with Gate-IMRT for liver cancer were selected to create ITV-IMRT plans. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The period and range of respiratory motion were recorded in all patients from 4DCT-generated movie data, and the same period and range were applied when operating the dynamic phantom to realize coincident respiratory conditions in each patient. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array and compared with the DVHs calculated for the Gate-IMRT plan. Results: Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Conclusion: Because Gate-IMRT cannot always be considered an ideal method with which to correct the respiratory motional effect, given the dosimetric variations in the gating system application and the increased treatment time, a prior analysis for optimal IMRT method selection should be performed while considering the patient's respiratory condition and IMRT plan results.

60 APPLIED LIFE SCIENCES↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

Large-Amplitude Motion Platform: A New Ocean Simulator Can Help Technologies Succeed

Offshore renewable energy technologies - like wave energy devices, wind turbines, floating solar panels, and hybrid systems - can help decarbonize our power grids as well as offshore activities like international shipping and seafood farming. But it's not always easy to build technologies hearty enough to operate in a powerful ocean environment. And subjecting promising prototypes to real ocean waves can be an expensive, time-consuming, and risky way to get these technologies ready for the high seas. Now, with the National Renewable Energy Laboratory's (NREL's) new testing platform, called the large-amplitude motion platform (or LAMP for short), our experts can replicate powerful ocean waves in a low-risk laboratory setting. The LAMP, coupled with NREL's diverse array of testing instrumentation, can help technology developers rapidly hone their prototypes before embarking on a potentially costly and time-consuming ocean trial.

marine energy↗

Statistical Modeling of CTV Motion and Deformation for IMRT of Early-Stage Rectal Cancer

Purpose: To derive and validate a statistical model of motion and deformation for the clinical target volume (CTV) of early-stage rectal cancer patients. Methods and Materials: For 16 patients, 4 to 5 magnetic resonance images (MRI) were acquired before each fraction was administered. The CTV was delineated on each MRI. Using a leave-one-out methodology, we constructed a population-based principal component analysis (PCA) model of the CTV motion and deformation of 15 patients, and we tested the model on the left-out patient. The modeling error was calculated as the amount of the CTV motion-deformation of the left-out-patient that could not be explained by the PCA model. Next, the PCA model was used to construct a PCA target volume (PCA-TV) by accumulating motion-deformations simulated by the model. A PCA planning target volume (PTV) was generated by expanding the PCA-TV by uniform margins. The PCA-PTV was compared with uniform and nonuniform CTV-to-PTV margins. To allow comparison, geometric margins were determined to ensure adequate coverage, and the volume difference between the PTV and the daily CTV (CTV-to-PTV volume) was calculated. Results: The modeling error ranged from 0.9 ± 0.5 to 2.9 ± 2.1 mm, corresponding to a reduction of the CTV motion-deformation between 6% and 60% (average, 23% ± 11%). The reduction correlated with the magnitude of the CTV motion-deformation (P<.001, R=0.66). The PCA-TV and the CTV required 2-mm and 7-mm uniform margins, respectively. The nonuniform CTV-to-PTV margins were 4 mm in the left, right, inferior, superior, and posterior directions and 8 mm in the anterior direction. Compared to uniform and nonuniform CTV-to-PTV margins, the PCA-based PTV significantly decreased (P<.001) the average CTV-to-PTV volume by 128 ± 20 mL (49% ± 4%) and by 35 ± 6 mL (20% ± 3.5%), respectively. Conclusions: The CTV motion-deformation of a new patient can be explained by a population-based PCA model. A PCA model-generated PTV significantly improved sparing of organs at risk compared to uniform and nonuniform CTV-to-PTV margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Dynamics Within a MITL Containing a Load

In this paper, we derive the vacuum electric fields within specific cylindrically symmetric magnetically insulated transmission lines (MITLs) in the limit of an infinite speed of light for an arbitrary time-dependent current. We focus our attention on two types of MITLs: the radial MITL and a spherically curved MITL. We then simulate the motion of charged particles, such as electrons, present in these MITLs due to the vacuum fields. In general, the motion of charged particles due to the vacuum fields is highly nonlinear since the fields are nonlinear functions of spatial coordinates and depend on an arbitrary time-dependent current drive. Using guiding center theory, however, one can describe the gross particle kinetics using a combination of $\textbf {E} \times \textbf {B}$ and $\nabla B$ drifts. In addition, we compare our approximate inner MITL field models and particle kinetics with those from a fully electromagnetic simulation code. We find that the agreement between the approximate model and the electromagnetic simulations is excellent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Driven responses of periodically patterned superconducting films

Here, we simulate the motion of a commensurate vortex lattice in a periodic lattice of artificial circular pinning sites having different diameters, pinning strengths, and spacings using the time-dependent Ginzburg-Landau formalism. Above some critical DC current density J c , the vortices depin, and the resulting steady-state motion then induces an oscillatory electric field E (t) with a defect "hopping" frequency f 0 , which depends on the applied current density and the pinning landscape characteristics. The frequency generated can be locked to an applied AC current density over some range of frequencies, which depends on the amplitude of the DC as well as the AC current densities. Both synchronous and asynchronous collective hopping behaviors are studied as a function of the supercell size of the simulated system and the (asymptotic) synchronization threshold current densities determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci—Sat AM: Stereo — 04: Evaluation of VMAT interplay effect for lung SABR using TrueBeam 10XFFF beam

During a VMAT treatment delivery, the interplay effect between the moving target and varying machine parameters result in dose distributions that are different from those initially planned. In this work, we investigate this effect for lung SABR by using 4D dose calculation derived from the Varian TrueBeam trajectory log file. The impact of treatment start phase is also evaluated. A QUASAR™ respiratory motion phantom was scanned with motion amplitudes of 0.4, 1, 2 and 3 cm with a 4 second period. MIP and the average dataset were generated from the 4DCT. A static CT was also acquired with the tumor in its centre position. Plans were optimized with 10X FFF beam until PTV and fictitious critical structures met the dose constraints. Ten temporally interleaved plans were constructed with the temporal machine parameter information from the trajectory log file. Ten plans were calculated with isocentre shifts to simulate respiratory motion and then summed. For each motion amplitude, three separate sum plans were created with various phase shifts (no phase shift, maximum inhalation and maximum exhalation) to assess the impact of treatment start phase. For all the phase shifts investigated, the DVH for PTV demonstrated good dose coverage. However, a careful review of slice by slice plan comparison indicates dose “holes” are observed within PTV. The PTV dose difference between various treatment start phases can be as high as 19%. This assumes all treatment fractions have identical treatment start phase. Our future work includes evaluation of interplay effect for various breathing periods.

60 APPLIED LIFE SCIENCES↗

MCNP6 Study of Spatial Fidelity Required for ROC Curve Convergence

The detection of special nuclear material at ports and borders is one of the primary missions of the Department of Homeland Security's (DHS) Domestic Nuclear Detection Office (DNDO). In support of this mission a large-scale modeling and simulation effort has been undertaken with the goal of providing a comprehensive tool-kit that addresses the complexity of problems involved with developing and maintaining technologies deployed to global nuclear detection architecture (GNDA) nodes. An important objective of DNDO's mission is to characterize detector system performance before deployment. In the effort to support this mission, the latest version of MCNP has been used to perform detectability studies of highly enriched uranium (HEU) to populate a database that will be used for the tool-kit. The characterization method used in the implementation of the database is the receiver operating characteristic (ROC). A ROC curve shows the limits of detectability of a given system as well as an overall metric of the efficacy of a detection system. This is accomplished by comparing total detector count distributions to the count distribution produced by background alone. For an in-depth explanation of the theory behind the MCNP production of ROC curves please refer to the paper, 'How To Use The Receiver Operating Characteristic Tally Option in MCNP6'. Building a useful database requires an expansive parameter space. The current tool-kit use nine parameters, which if varied with just 5 options each, results in nearly two million simulations to run. Depending on the set of parameters these simulations can take a few hours or a few weeks to complete. This computational cost necessitates the use of scaling algorithms to interpolate between the data contained in the database. The tool-kit employs a discrete event method to simulate the movement and detector response of special nuclear material (SNM) through a GNDA node. Given the nature of a discrete event simulation, constant motion of SNM must be split up in to discrete spatial detection points. The fidelity required of the spatial splitting to achieve a properly converged answer is investigated here for a neutron detection system. The detector used was a SNAP-3 neutron detector in front of a sphere of SNM in the presence of background radiation. A parameter study has been performed to determine the spatial fidelity required for ROC curve convergence for moving objects in a discrete event simulator. It appears that 5 points is the minimum number of detection points with 7 points needed for one of the parameter sets. The convergence worsens with increases to detection length but appears to improve with increasing detector distance. These results will help future work involving quantifying the accuracy based on given tolerances and parameters. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetron-driven microton-injector of a terahertz free electron laser

A magnetron-driven microtron injector has been developed for a terahertz free electron laser (FEL). An internal injection system was chosen for the microtron to achieve a compact and inexpensive design. The system provides acceleration of electrons with low emittance and energy spread that is highly important for the FEL. However, the intrapulse instabilities of the accelerated current and the bunch repetition rate inherent to the injection system make problems for the FEL operation. Simulations of the beam dynamics and the transient process allow one to compute the load characteristic of the accelerating cavity and the time-dependent accelerated current. The simulation techniques also allow one to calculate time-dependent deviations of the magnetron frequency in the coupled system of the accelerating and magnetron cavities, as well as deviations in the bunch repetition rate. The computations validate proposed concepts for increasing the intrapulse current stability with appropriate time-dependent variation of the magnetron power and decreasing the bunch repetition rate instability through a simple microwave scheme utilizing the microtron accelerating cavity concurrently as an external stabilizing resonator for the magnetron. The realized concepts and optimization of the microtron regimes using the simulated phase motion of the accelerated bunch provide stable operation of the terahertz FEL, tunable in the range of 1-3 THz with extracted macropulse power up to 50 Watts at the macropulse energy of -0.2 mJ.

43 PARTICLE ACCELERATORS↗

Overview of the SCEC/USGS Community Stress Drop Validation Study Using the 2019 Ridgecrest Earthquake Sequence

We present initial findings from the ongoing Community Stress Drop Validation Study to compare spectral stress-drop estimates for earthquakes in the 2019 Ridgecrest, California, sequence. This study uses a unified dataset to independently estimate earthquake source parameters through various methods. Stress drop, which denotes the change in average shear stress along a fault during earthquake rupture, is a critical parameter in earthquake science, impacting ground motion, rupture simulation, and source physics. Spectral stress drop is commonly derived by fitting the amplitude-spectrum shape, but estimates can vary substantially across studies for individual earthquakes. Sponsored jointly by the U.S. Geological Survey and the Statewide (previously, Southern) California Earthquake Center our community study aims to elucidate sources of variability and uncertainty in earthquake spectral stress-drop estimates through quantitative comparison of submitted results from independent analyses. The dataset includes nearly 13,000 earthquakes ranging from M 1 to 7 during a two-week period of the 2019 Ridgecrest sequence, recorded within a 1° radius. Here, in this article, we report on 56 unique submissions received from 20 different groups, detailing spectral corner frequencies (or source durations), moment magnitudes, and estimated spectral stress drops. Methods employed encompass spectral ratio analysis, spectral decomposition and inversion, finite-fault modeling, ground-motion-based approaches, and combined methods. Initial analysis reveals significant scatter across submitted spectral stress drops spanning over six orders of magnitude. However, we can identify between-method trends and offsets within the data to mitigate this variability. Averaging submissions for a prioritized subset of 56 events shows reduced variability of spectral stress drop, indicating overall consistency in recovered spectral stress-drop values.

58 GEOSCIENCES↗

Estimating nonrigid motion from inconsistent intensity with robust shape features

Purpose: To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Methods: Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, and regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. Results: To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided qualitatively appealing results, demonstrating good feasibility and applicability of the proposed method. Conclusions: The authors have developed a novel method to estimate the nonrigid motion of GOIs in the presence of spatial intensity and contrast variations, taking advantage of robust shape features. Quantitative analysis and qualitative evaluation demonstrated good promise of the proposed method. Further clinical assessment and validation is being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variational Symplectic Integrator for Long-Time Simulations of the Guiding-Center Motion of Charged Particles in General Magnetic Fields

A variational symplectic integrator for the guiding-center motion of charged particles in general magnetic fields is developed for long-time simulation studies of magnetized plasmas. Instead of discretizing the differential equations of the guiding-center motion, the action of the guiding-center motion is discretized and minimized to obtain the iteration rules for advancing the dynamics. The variational symplectic integrator conserves exactly a discrete Lagrangian symplectic structure, and has better numerical properties over long integration time, compared with standard integrators, such as the standard and variable time-step fourth order Runge-Kutta methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variational Symplectic Integrator for Long-Time Simulations of the Guiding-Center Motion of Charged Particles in General Magnetic Fields

A variational symplectic integrator for the guiding-center motion of charged particles in general magnetic fields is developed for long-time simulation studies of magnetized plasmas. Instead of discretizing the differential equations of the guiding-center motion, the action of the guiding-center motion is discretized and minimized to obtain the iteration rules for advancing the dynamics. The variational symplectic integrator conserves exactly a discrete Lagrangian symplectic structure, and has better numerical properties over long integration time, compared with standard integrators, such as the standard and variable time-step fourth order Runge-Kutta methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical formulation and numerical algorithm for simulating N immiscible incompressible fluids involving general order parameters

We present a family of physical formulations, and a numerical algorithm, based on a class of general order parameters for simulating the motion of a mixture of N (N⩾2) immiscible incompressible fluids with given densities, dynamic viscosities, and pairwise surface tensions. The N-phase formulations stem from a phase field model we developed in a recent work based on the conservations of mass/momentum, and the second law of thermodynamics. The introduction of general order parameters leads to an extremely strongly-coupled system of (N−1) phase field equations. On the other hand, the general form enables one to compute the N-phase mixing energy density coefficients in an explicit fashion in terms of the pairwise surface tensions. We show that the increased complexity in the form of the phase field equations associated with general order parameters in actuality does not cause essential computational difficulties. Our numerical algorithm reformulates the (N−1) strongly-coupled phase field equations for general order parameters into 2(N−1) Helmholtz-type equations that are completely de-coupled from one another. This leads to a computational complexity comparable to that for the simplified phase field equations associated with certain special choice of the order parameters. We demonstrate the capabilities of the method developed herein using several test problems involving multiple fluid phases and large contrasts in densities and viscosities among the multitude of fluids. In particular, by comparing simulation results with the Langmuir–de Gennes theory of floating liquid lenses we show that the method using general order parameters produces physically accurate results for multiple fluid phases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An efficient algorithm for incompressible N-phase flows

We present an efficient algorithm within the phase field framework for simulating the motion of a mixture of N (N⩾2) immiscible incompressible fluids, with possibly very different physical properties such as densities, viscosities, and pairwise surface tensions. The algorithm employs a physical formulation for the N-phase system that honors the conservations of mass and momentum and the second law of thermodynamics. We present a method for uniquely determining the mixing energy density coefficients involved in the N-phase model based on the pairwise surface tensions among the N fluids. Our numerical algorithm has several attractive properties that make it computationally very efficient: (i) it has completely de-coupled the computations for different flow variables, and has also completely de-coupled the computations for the (N−1) phase field functions; (ii) the algorithm only requires the solution of linear algebraic systems after discretization, and no nonlinear algebraic solve is needed; (iii) for each flow variable the linear algebraic system involves only constant and time-independent coefficient matrices, which can be pre-computed during pre-processing, despite the variable density and variable viscosity of the N-phase mixture; (iv) within a time step the semi-discretized system involves only individual de-coupled Helmholtz-type (including Poisson) equations, despite the strongly-coupled phase–field system of fourth spatial order at the continuum level; (v) the algorithm is suitable for large density contrasts and large viscosity contrasts among the N fluids. Extensive numerical experiments have been presented for several problems involving multiple fluid phases, large density contrasts and large viscosity contrasts. In particular, we compare our simulations with the de Gennes theory, and demonstrate that our method produces physically accurate results for multiple fluid phases. We also demonstrate the significant and sometimes dramatic effects of the gravity, density ratios, pairwise surface tensions, and drop sizes on the N-phase configurations and dynamics. The numerical results show that the method developed herein is capable of dealing with N-phase systems with large density ratios, large viscosity ratios, and pairwise surface tensions, and that it can be a powerful tool for studying the interactions among multiple types of fluid interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗