Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM↗

Dynamically triggered slip leading to sustained fault gouge weakening under laboratory shear conditions

We investigate dynamic wave-triggered slip under laboratory shear conditions. The experiment is composed of a three-block system containing two gouge layers composed of glass beads and held in place by a fixed load in a biaxial configuration. When the system is sheared under steady state conditions at a normal load of 4 MPa, we find that shear failure may be instantaneously triggered by a dynamic wave, corresponding to material weakening and softening if the system is in a critical shear stress state (near failure). Following triggering, the gouge material remains in a perturbed state over multiple slip cycles as evidenced by the recovery of the material strength, shear modulus, and slip recurrence time. This work suggests that faults must be critically stressed to trigger under dynamic conditions and that the recovery process following a dynamically triggered event differs from the recovery following a spontaneous event.

58 GEOSCIENCES↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring quasiparticle dynamics for particle impact reconstruction in a superconducting qubit chip

Quasiparticle poisoning following particle impacts poses a significant challenge to the development of fault-tolerant superconducting quantum computers, as a sudden excess of quasiparticles can simultaneously degrade the coherence of multiple qubits across large device arrays. In this work, we present a statistical analysis that models the time evolution of radiation-induced qubit energy relaxation through quasiparticle density dynamics. This study provides insight into quasiparticle loss processes by distinguishing between recombination and trapping decay channels and assessing their respective impact on qubit performance. We precisely measure quasiparticle recombination in multiple transmon qubits and uncover an unexpected dependence of qubit relaxation dynamics on deposited energy. By linking correlated relaxation events across qubits to ballistic phonon propagation, we introduce a statistical localization approach to extract the energy deposited in the substrate, which is in good agreement with Monte Carlo simulation. This work establishes the quantitative framework for using an arbitrary subset of superconducting transmon qubits in a QPU as energy-resolving witness particle detectors.

Celi, E. [Northwestern U.]↗

Structural Orientations Adjacent to Some Colorado Geothermal Systems

Structural orientations (fractures, joints, faults, lineaments, bedding orientations, etc.) were collected with a standard Brunton compass during routine field examinations of geothermal phenomena in Colorado. Often multiple orientations were taken from one outcrop. Care was taken to ensure outcrops were "in place". Point data was collected with a hand-held GPS unit. The structural data is presented both as standard quadrant measurements and in format suitable for ESRI symbology

15 GEOTHERMAL ENERGY↗

GHOST (Grid Hardware Open Source Testbed) [SWR-18-32]

The software was developed for the purpose of Microgrid Controller Procurement where multiple Microgrid Controller vendors were competing to prove the best performance. Each microgrid controller was connected to Real-Time Simulator (Opal-RT) where the Real-Time model of microgrid was simulated. Microgrid controllers were able to control most of the assets in the model. To be able to fairly compare controller's performance each controller was evaluated using exactly the same model, with the same initial conditions and exactly the same test sequence. The microgrid evaluation test sequence lasted 100 minutes and consist of various grid disturbances to which a microgrid controller must respond. The microgrid and power system will experience multiple types of disturbances while performing dispatch functions. Many functions are tested in grid-connected and islanded modes such as unexpended failures of generators, energy storage trip events, and large load fluctuations. The test sequence focuses on fault scenarios that cause the highest short-circuit fault current contribution; force a swing bus or generator capable of being a swing bus offline; cause the most reconfigurations; and cause conflicting objectives for the microgrid controller. During the test sequence execution multiple datapoints are being recorded and stored. During data postprocessing key performance parameters are extracted allowing quantitative comparison of performance on multiple aspects including: resiliency, fuel utilization, grid interconnection, ancillary services and power quality and eventually after summing all key performance parameters by comparing the overall result. To be able to perform such testing multiple tools had to be developed included in this repository including: - Real time model of microgrid (Urban-Banshee, Remote-smaller model) - Test sequence configuration tools - Test execution real-time scripts - Post processing scripts - Human Machine Interface software

Koralewicz, Przemyslaw↗

Evidence for a Single Holocene Paleoseismic Event on the Pajarito Fault, Northern New Mexico

Low-slip rate fault systems tend to be less studied than their high-slip rate counterparts, and paleoseismic techniques used to study them may pose challenges in interpretation that differ from high-slip rate systems. A good example of this is the Pajarito fault system (PFS), a normal fault complex within the Rio Grande rift. Despite numerous previous paleoseismic trenching studies conducted on the PFS between 1990 and 2003, considerable uncertainty remains regarding its Holocene paleoseismic history, particularly for the primary Pajarito fault (PF). To further clarify the PF paleoseismic history, we present data from paleoseismic investigations of 6 trenches at 3 distinct locations along the PF. Though the totality of the age and structural data obtained in this study is complex and not entirely consistent with any one interpretation, a single Holocene paleoearthquake occurring younger than ∼1,600 to 2,300 kcal yr BP is the simplest interpretation. It is possible that the PF records two Holocene events, with a penultimate event 6.9–2.4 kcal yr BP event and the aforementioned most recent event (MRE) between 2.3 and 1.6 kcal yr BP. However, only a single wall of one trench, out of a total of 12 walls in our 6 trenches, provides evidence supporting that interpretation. This study finds evidence of a single late Holocene paleoseismic event on the PF and sparse evidence for 2 Holocene paleoseismic events on the PF and highlights the benefits of logging multiple trench walls to better understand the complexity that results from this low-slip rate, low-deposition-rate fault system.

58 GEOSCIENCES↗

Tolerating Correlated Failures for Generalized Cartesian Distributions via Bipartite Matching

Faults are expected to play an increasingly important role in how algorithms and applications are designed to run on future extreme-scale systems. A key ingredient of any approach to fault tolerance is effective support for fault tolerant data storage. A typical application execution consists of phases in which certain data structures are modified while others are read-only. Often, read-only data structures constitute a large fraction of total memory consumed. Fault tolerance for read-only data can be ensured through the use of checksums or parities, without resorting to expensive in-memory duplication or checkpointing to secondary storage. In this paper, we present a graph-matching approach to compute and store parity data for read-only matrices that are compatible with fault tolerant linear algebra (FTLA). Typical approaches only support blocked data distributions with each process holding one block with the parity located on additional processes. The matrices are assumed to be blocked by a cartesian grid with each block assigned to a process. We consider a generalized distribution in which each process can be assigned arbitrary blocks. We also account for the fact that multiple processes might be part of the same failure unit, say an SMP node. The flexibility enabled by our novel application of graph matching extends fault tolerance support to data distributions beyond those supported by prior work. We evaluate the matching implementations and cost to compute the parity and recover lost data, demonstrating the low overhead incurred by our approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preferred orientation of phyllosilicates: Comparison of fault gouge, shale and schist

Samples of fault gouge from the San Andreas Fault drill hole (SAFOD), a shale from the North Sea sedimentary basin and schists from metamorphic rocks in the Alps have been analyzed with high energy synchrotron X-rays to determine preferred orientation of mica and clay minerals. The method relies on obtaining 2D diffraction images which are then processed with the crystallographic Rietveld method, implemented in the software MAUD, allowing for deconvolution of phases and extraction of their orientation distributions. It is possible to distinguish between detrital illite/muscovite and authigenic illite/smectite, kaolinite and chlorite, and muscovite and biotite, with strongly overlapping peaks in the diffraction pattern. The results demonstrate that phyllosilicates show large texture variations in various environments, where different mechanisms produce the rock microfabrics: fault gouge fabrics are quite weak and asymmetric with maxima for (001) in the range of 1.5-2.5 multiples of random distribution (m.r.d.). This is attributed to heterogeneous deformation with randomization, as well as dissolution-precipitation reactions. Shale fabrics have maxima ranging from 3 to 9 m.r.d. and this is due to sedimentation and compaction. The strongest fabrics were observed in metamorphic schists (10-14 m.r.d.) and developed by deformation as well as recrystallization in a stress field. In the analyzed samples, fabrics of co-existing quartz are weak. All phyllosilicate textures can be explained by orientation of (001) platelets, with no additional constraints on a-axes.

43 PARTICLE ACCELERATORS↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced High-Performance Computational Modeling of the Seismic Response of High-Hazard and/or Nuclear Facilities and Critical Infrastructure at the NNSS

New methods for predicting the amplitude and variability of ground shaking from earthquakes (and explosions) are needed for seismic hazard analysis for buildings, nuclear power plants, and critical infrastructure at the NNSS. We are comparing existing 1-D and new 3-D geophysical methods for estimating the shear-wave velocity structure in the upper 30 meters of the ground surface (Vs30), which plays a major role in ground motion amplification and seismic response of buildings. We evaluate the performance of these methodologies at the U1a Complex at the NNSS and develop simple 1-D and high-resolution 3-D Vs30 models. We then emplace these high-resolution models into a background seismic velocity model. We will collaborate with Lawrence Livermore National Laboratory (LLNL) to conduct numerical modeling of the ground shaking at the NNSS using their high-performance computing technology and state-of-the-art ground motion simulation methodology. The primary work that was completed in FY 2019 was to acquire the seismic systems and familiarize staff at the NNSS with their use. We also worked on developing a collection plan with the Device Assembly Facility (DAF) at the NNSS, but due to time constraints and other ongoing projects at the DAF, we had to use U1a as a backup. We were able to coordinate the seismic survey, and we will complete the collection of seismic data in FY 2020. Additionally, during FY 2019, we completed the geologic framework model (GFM) for the U1a Complex and modeled the Yucca fault. LLNL worked with us through FY 2019 to prepare the data files for their modeling software and tested the software for reliability. In FY 2020 we will develop the end-to-end capability so that any facility could easily be modeled and the expected shaking from a local earthquake understood. The work in FY 2020 will include building fault models from the GFM and finalizing the velocity model analysis. The final simulations will be run for multiple rupture models, and final assessments will demonstrate the seismic hazard at the U1a Complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Crack fault diagnosis of rotating machine in nuclear power plant based on ensemble learning

Crack faults in rotating machines can cause machine shutdown or scrapping, endangering the normal operation and safety of nuclear power plants. Intelligent diagnostic techniques based on machine learning have the potential to diagnose crack faults. However, problems such as scarcity of field fault data and high noise of plant measurements pose challenges to the application of machine learning. Here this study proposes an ensemble learning approach to mitigate the negative impacts of the problems. Ensemble learning is a strategy for combining multiple machine learning models into a composite model. The basic idea of ensemble learning is that even if one model makes a mistake, other models can correct it. Case studies based on bearing and gear system fault experiments show that the proposed ensemble learning models have better diagnostic results than the single model in the presence of noise and small data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Probabilistic Approach to Enable Extreme-Scale Simulations under Uncertainty and System Faults. Final Technical Report

The current project develops a novel approach that uses a probabilistic description to capture the current state of knowledge about the computational solution. To effectively spread the computational effort over multiple nodes, the global computational domain is split into many subdomains. Computational uncertainty in the solution translates into uncertain boundary conditions for the equation system to be solved on those subdomains, and many independent, concurrent subdomain simulations are used to account for this bound- ary condition uncertainty. By relying on the fact that solutions on neighboring subdomains must agree with each other, a more accurate estimate for the global solution can be achieved. Statistical approaches in this update process make it possible to account for the effect of system faults in the probabilistic description of the computational solution, and the associated uncertainty is reduced through successive iterations. By combining all of these elements, the probabilistic reformulation allows splitting the computational work over very many independent tasks for good scalability, while being robust to system faults.

97 MATHEMATICS AND COMPUTING↗

Technical Requirements for Application of Operator Support Technology across Multiple Plant Systems

Argonne National Laboratory (ANL) and Idaho National Laboratory (INL) are jointly developing and evaluating operator aids to: (i) facilitate more timely response to plant faults and grid disturbances; (ii) achieve better management of plant upsets and improved operator performance; and (iii) ultimately improve nuclear plant safety, production, and cost management. The overall objective of the collaborative effort in this third and final year of the project was to conduct human performance tests using nuclear plant operators in the Human Systems Simulation Laboratory (HSSL) control room at INL to assess the value of a computerized operator support system (COSS) as an aid to the operator. This report describes the work performed by ANL. A companion report describes the work performed by INL and the results of the human performance tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗