Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Simulations of the WFIRST Supernova Survey and Forecasts of Cosmological Constraints

The Wide Field InfraRed Survey Telescope (WFIRST) was the highest-ranked large space-based mission of the 2010 New Worlds, New Horizons decadal survey. It is now a NASA mission in formulation with a planned launch in the mid 2020s. A primary mission objective is to precisely constrain the nature of dark energy through multiple probes, including Type Ia supernovae (SN Ia). Here, we present the first realistic simulations of the WFIRST SN survey based on current hardware specifications and using open-source tools. We simulate SN light curves and spectra as viewed by the WFIRST wide-field channel (WFC) imager and integral field channel (IFC) spectrometer, respectively. We examine 11 survey strategies with different time allocations between the WFC and IFC, two of which are based upon the strategy described by the WFIRST Science Definition Team, which measures SN distances exclusively from IFC data. We propagate statistical and, crucially, systematic uncertainties to predict the Dark Energy Task Force figure of merit (FoM) for each strategy. Of the strategies investigated, we find the most successful to be WFC focused. However, further work in constraining systematics is required to fully optimize the use of the IFC. Even without improvements to other cosmological probes, the WFIRST SN survey has the potential to increase the FoM by more than an order of magnitude from the current values. Although the survey strategies presented here have not been fully optimized, these initial investigations are an important step in the development of the final hardware design and implementation of the WFIRST mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Design and Performance of Low Cost Haptic Interfaces to Control Precision Nuclear Robotic System - 18351

Nuclear decommissioning environments are challenging and hazardous, typically involving high temperatures, pressures and extreme radiation. Robotic devices are commonly used to complete tasks within challenging environments, which would otherwise pose a risk to human health, however remotely operating robots without full three-dimensional vision is challenging, and operators of robotic systems require extensive training to enable precise navigation through three-dimensional environments using multiple two-dimensional views for feedback. This project explores the possibility of using a human arm as a master device for controlling a variety of low-cost slave robots, with the aim of reducing training times whilst providing a cheaper, more intuitive control system. Virtual Reality (VR) and haptics are used as an aid for navigation of the remote environment, whilst also providing a digital twin for the operator to enable real-time feedback from the slave robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Low Power ARM Processors for Monte Carlo Particle Transport: MCNP6 on the ARM Cortex-A8 - Paper 83

In the push towards exascale computing, the limiting factors are power requirements and heat dissipation. Using current technology, the power required to drive an exascale supercomputer would near 400-MW. Clearly, future computing hardware will have to be more energy efficient in order to achieve exascale performance. Most of the current research in advanced computing architectures is in the use of standard CPUs with accelerators. However, these accelerators are not generally supported by the traditional scientific programming languages (C, C++, and Fortran) and the scientific software must be tailored specifically to take advantage of the accelerators. Large scale scientific software (hundreds-of-thousand to millions of lines of code) can not be easily ported to the computing platform du jour. The widespread use of low power ARM based processors in the mobile computing market offer a low power alternative to accelerators that are also supported by the traditional scientific programming languages and programming paradigms such as MPI and OpenMP. Computing architectures for scientific computing are often assessed using standard benchmarks such as LINPACK benchmark or using suites of mini-applications that are greatly simplified stand-ins for scientific software. Often the real applications that will deployed on the scientific supercomputers are not ported or tested until delivery of the machines. In order to evaluate the use of ARM processors for scientific computing the Monte Carlo particle transport code, MCNP version 6 was compiled on the ARM Cortex-A8 and a set of benchmark problems were used to assess performance in comparison to an Intel Xeon E5-2670 and the low power Intel Atom N270. MCNP is a continuous energy Monte Carlo particle transport code in development at Los Alamos National Laboratory since 1977. MCNP is used to transport neutrons, photon, electrons, and charged particles using continuous energy interaction data. It is commonly used in fields of nuclear power, nuclear medicine, radiation protection, and high-energy physics through-out the world. MCNP version 6 is approximately 450 thousand lines of code, written primary in Fortran90, with some C and C++. MCNP supports distributed multiprocessing using MPI and threading with OpenMP. The ARM Cortex-A8 executes MCNP6 using about twice as much power as the Intel Xeon E5-2670 and about the same amount of power as the Intel Atom N270. However, these results are encouraging for the use of low-power ARM chips in future supercomputers. The ARM Cortex-A8 is a 32-bit CPU and it's NEON general-purpose SIMD (single-instruction multiple data) engine does not support double-precision floating-point arithmetic. More recent ARM processors (ARM Cortex-A53 and Cortex-A57) support 64-bit addressing and have NEON co-processors that support double-precision floating-point arithmetic. ARM claims that the A50 series delivers a performance increase of 15 times the Cortex-A8 performance for similar power usage. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Dijet Acoplanarity Tomography of the Chromo Structure of Perfect QCD Fluids

Dijet acoplanarity is dominated by vacuum (Sudakov) pQCD radiation even in Pb+Pb collisions, but future higher precision measurements of the tails of the acoplanarity distributions can help to resolve separately the medium opacity, χ=L/λ and the color screening scale μ 2 from the path averaged BDMS saturation scale Q$^2_s$[χ,μ]=∫dL$\hat{q}$(E,T(L))∝μ 2 L/λ that is already well constrained by nuclear modification factor data on R AA (p T ). We compare Gaussian (BDMS) and non-Gaussian (GLV) models of medium broadening of vacuum (Sudakov) induced acoplanarity distributions in A+A. With few percent accuracy on the ratio of A+A to p+p distributions, experiments can easily identify non-Gaussian Landau and Rutherford tails due to multiple collisions. However, we find that sub-percent precision will be required to constrain χ and μ separately from Q s .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fully Robotic Hot Cell Crane for Target Hall Operations at Isotope Research Facility - 18329

There are many types of equipment used in high radiation environments, but the super-sized and high precision lifting requirements for an isotope research facility in the USA called for one of the largest fully robotic cranes in the US. The 20 Ton Remote Handling Bridge Crane provided by PaR Systems met many challenging requirements for accuracy, repeatability and unique lifting motions in the radiation-shielded target hall of this facility. This robotic system was designed to address four main issues. The first is that the crane needed to be operated remotely due to high radioactivity during the time when it is needed most. Second is that high precision is needed due to the complex fit of multiple heavy shielding blocks. Third problem is that automated routines and exclusion areas were needed due to the remote operation of the system around high capital cost equipment. Lastly is the survivability of the equipment due to the high radiation environment. The facility robotic crane is an overhead top running multiple girder hot cell bridge crane (hereafter referred to as the system). The system is intended to be used in either manually operated or automated operation under computer control. Under automated control, the system provides highly accurate motion control in three linear axes as well as hook rotation. Using motion control programming, this highly accurate system ensures safe, remote movement of in-cell components. The system was designed to be remotely operated by a technician from the remote handling control room in the facility. This is facilitated by computer control using the System Graphical User Interface with feedback from a facility supplied video system. It can also be operated using a wireless hand held controller. The system will be used to place sensitive components with high precision in locations that will be difficult to observe directly. In order to accomplish this, it is critical that the system be capable of moving its payload with minimal swing, and with high accuracy, repeatability and reliability. The system will be operating in an environment where it will be exposed to both high energy neutrons and gamma radiation. Under beam-off conditions, the target hall will be hands-on accessible to accommodate crane maintenance. The system was installed and tested in early 2017 in advance of the live operations of the facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PARSEC-SCALE RADIO EMISSION FROM THE LOW-LUMINOSITY ACTIVE GALACTIC NUCLEUS IN THE DWARF STARBURST GALAXY HENIZE 2-10

A candidate accreting massive black hole (BH) with M{sub BH} {approx} 10{sup 6} M{sub Sun} has recently been identified at the center of the dwarf starburst galaxy Henize 2-10 (He 2-10). This discovery offers the first possibility of studying a growing BH in a nearby galaxy resembling those in the earlier universe, and opens up a new class of host galaxies to search for the smallest supermassive BHs. Here we present very long baseline interferometry observations of He 2-10 taken with the Long Baseline Array (LBA) at 1.4 GHz with an angular resolution of {approx}0.''1 Multiplication-Sign 0.''03. A single compact radio source is detected at the precise location of the putative low-luminosity active galactic nucleus. The physical size of the nuclear radio emission is {approx}<3 pc Multiplication-Sign 1 pc, an order of magnitude smaller than previous constraints from the Very Large Array (VLA), and the brightness temperature of T{sub B} > 3 Multiplication-Sign 10{sup 5} K confirms a non-thermal origin. These LBA observations indicate that the nuclear radio emission originates from a single object, and exclude the possibility of multiple supernova remnants as the origin of the nuclear radio emission previously detected with the VLA at lower resolution. A weaker, more extended, off-nuclear source is also detected with the LBA and a comparison with multi-wavelength ancillary data indicate that, unlike the nuclear source, the off-nuclear source is co-spatial with a super star cluster, lacks a detectable X-ray point-source counterpart, and is almost certainly due to a supernova remnant in the host star cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of needle and armature dynamics in a gasoline direct injector by high-speed neutron imaging

In modern spark ignition engines, precise delivery of fuel with gasoline direct injection has become increasingly important in the effort to meet ever stricter efficiency and emissions regulations. Use of multiple small close-coupled injections has become more common in attempt to precisely control fuel distribution in the cylinder, but these strategies are hindered by nonlinear injection effects due to operation in the ballistic region of the solenoid-operated valve and due to armature bounce at the end of injection. Understanding the internal dynamics of the injector is crucial to minimizing and controlling non-linearity and shot-to-shot variation, but the experimental techniques available to date are capable only of tracking the position of either the top of the needle (via laser sensors or by monitoring current and voltage in the solenoid coil) or the bottom of the needle (via transparent nozzles or high-speed x-ray imaging). Furthermore, a complete picture of the axial and radial motion of valve needle has until now remained elusive. In this work, we present high-speed ensemble neutron transmission imaging of an entire 8-hole gasoline direct injector operating at 200 bar, allowing for both visualization and quantification of the actuation dynamics including lift and wobble of the valve ball, oscillation and bending of the valve needle, lift, rocking, and bounce of the armature, compression of the springs, and radial swelling of the solenoid during energization. Because neutrons offer high penetration through the metal injector while also being sensitive to the 1 H nuclei in fuel molecules, it is also possible to simultaneously see the fluid dynamics of the injection process, including filling of the sac volume, emanation of the spray through the nozzle holes and into the downstream gas, and the formation and evolution of fuel films on the tip of the injector and the walls of the spray container.

33 ADVANCED PROPULSION SYSTEMS↗

Understanding Mixed Precision GEMM with MPGemmFI: Insights into Fault Resilience

Emerging deep learning workloads urgently need fast general matrix multiplication (GEMM). Thus, one of the critical features of machine-learning-specific accelerators such as NVIDIA Tensor Cores, AMD Matrix Cores, and Google TPUs is the support of mixed-precision enabled GEMM. For DNN models, lower-precision FP data formats and computation offer acceptable correctness but significant performance, area, and memory footprint improvement. While promising, the mixed-precision computation on error resilience remains unexplored. To this end, we develop a fault injection framework that systematically injects fault into the mixed-precision computation results. We investigate how the faults affect the accuracy of machine learning applications. Based on the characteristics of error resilience, we offer lightweight error detection and correction solutions that significantly improve the overall model accuracy by 75% if the models experience hardware faults. The solutions can be efficiently integrated into the accelerator's pipelines.

Fang, Bo↗

Efficient Mixed-Precision Matrix Factorization of the Inverse Overlap Matrix in Electronic Structure Calculations with AI-Hardware and GPUs

In recent years, a new kind of accelerated hardware has gained popularity in the artificial intelligence (AI) community which enables extremely high-performance tensor contractions in reduced precision for deep neural network calculations. In this article, we exploit Nvidia Tensor cores, a prototypical example of such AI-hardware, to develop a mixed precision approach for computing a dense matrix factorization of the inverse overlap matrix in electronic structure theory, S –1 . This factorization of S –1 , written as ZZT = S –1 , is used to transform the general matrix eigenvalue problem into a standard matrix eigenvalue problem. Here we present a mixed precision iterative refinement algorithm where Z is given recursively using matrix–matrix multiplications and can be computed with high performance on Tensor cores. To understand the performance and accuracy of Tensor cores, comparisons are made to GPU-only implementations in single and double precision. Additionally, we propose a nonparametric stopping criteria which is robust in the face of lower precision floating point operations. The algorithm is particularly useful when we have a good initial guess to Z, for example, from previous time steps in quantum-mechanical molecular dynamics simulations or from a previous iteration in a geometry optimization.

36 MATERIALS SCIENCE↗

Towards Precision-Aware Fault Tolerance Approaches for Mixed-Precision Applications

Graphics Processing Units (GPUs), the dominantly adopted accelerators in HPC systems, are susceptible to transient hardware fault. New generation of GPUs feature mixed-precision architectures such as NVIDIA Tensor Cores to accelerate matrix multiplications. While being widely adapted, how would they behave under transient hardware faults remain unclear. In this study, we conduct a large-scale fault injection experiments on GEMM kernels implemented with different floating-point data types on the V100 and A100 Tensor Cores, and show distinct error resilience characteristics for the GEMMS with different formats. In the future, we plan to explore this space by building precision-aware floating-point fault tolerance techniques for applications such as DNNs that exercise low-precision computations.

Fang, Bo↗

An Optimal Parameterization Framework for Infrasonic Tomography of the Stratospheric Winds Using Non-Local Sources

A method is developed to apply acoustic tomography methods to a localized network of infrasound arrays with intention of monitoring the atmosphere state in the region around the network using non-local sources without requiring knowledge of the precise source location or non-local atmosphere state. Closely spaced arrays provide a means to estimate phase velocities of signals that can provide limiting bounds on certain characteristics of the atmosphere. Larger spacing between such clusters provide a means to estimate celerity from propagation times along multiple unique stratospherically or thermospherically ducted propagation paths and compute more precise estimates of the atmosphere state. In order to avoid the commonly encountered complex, multimodal distributions for parametric atmosphere descriptions and to maximize the computational efficiency of the method, an optimal parametrization framework is constructed. This framework identifies the ideal combination of parameters for tomography studies in specific regions of the atmosphere and statistical model selection analysis shows that high quality corrections to the middle atmosphere winds can be obtained using as few as three parameters. Lastly, comparison of the resulting estimates for synthetic data sets shows qualitative agreement between the middle atmosphere winds and those estimated from infrasonic traveltime observations.

58 GEOSCIENCES↗

A COMPLETE SAMPLE OF ULTRALUMINOUS X-RAY SOURCE HOST GALAXIES

One hundred seven ultraluminous X-ray sources (ULXs) with 0.3-10.0 keV luminosities in excess of 10{sup 39} erg s{sup -1} are identified in a complete sample of 127 nearby galaxies. The sample includes all galaxies within 14.5 Mpc above the completeness limits of both the Uppsala Galaxy Catalogue and the Infrared Astronomical Satellite survey. The galaxy sample spans all Hubble types, a four-decade range in mass, 7.5 < log (M/M{sub sun}) < 11.4, and in star formation rate, 0.0002 < SFR(M{sub sun} yr{sup -1}) {<=} 3.6. ULXs are detected in this sample at rates of one per 3.2 Multiplication-Sign 10{sup 10} M{sub sun}, one per {approx}0.5 M{sub sun} yr{sup -1} star formation rate, and one per 57 Mpc{sup 3} corresponding to a luminosity density of {approx}2 Multiplication-Sign 10{sup 37} erg s{sup -1} Mpc{sup -3}. At these rates we estimate as many as 19 additional ULXs remain undetected in fainter dwarf galaxies within the survey volume. An estimated 14 objects, or 13%, of the 107 ULX candidates are expected to be background sources. The differential ULX luminosity function shows a power-law slope {alpha} {approx} -0.8 to -2.0 with an exponential cutoff at {approx}20 Multiplication-Sign 10{sup 39} erg s{sup -1} with precise values depending on the model and on whether the ULX luminosities are estimated from their observed numbers of counts or, for a subset of candidates, from their spectral shapes. Extrapolating the observed luminosity function predicts at most one very luminous ULX, L{sub X} {approx} 10{sup 41} erg s{sup -1}, within a distance as small as 100 Mpc. The luminosity distribution of ULXs within the local universe cannot account for the recent claims of luminosities in excess of 2 Multiplication-Sign 10{sup 41} erg s{sup -1}, requiring a new population class to explain these extreme objects.

79 ASTRONOMY AND ASTROPHYSICS↗

CALORIMETER-BASED ADJUSTMENT OF MULTIPLICITY DETERMINED 240PU EFF KNOWN-A ANALYSIS FOR THE ASSAY OF PLUTONIUM

In nuclear material processing facilities, it is often necessary to balance the competing demands of accuracy and throughput. While passive neutron multiplicity counting is the preferred method for relatively fast assays of plutonium, the presence of low-Z impurities (fluorine, beryllium, etc.) rapidly erodes the assay precision of passive neutron counting techniques, frequently resulting in unacceptably large total measurement uncertainties. Conversely, while calorimeters are immune to these impurity effects, the long count times required for high accuracy can be a hindrance to efficiency. The higher uncertainties in passive neutron measurements of impure material are driven by the resulting large (>>2) {alpha}-values, defined as the ({alpha},n):spontaneous fission neutron emission ratio. To counter impurity impacts for high-{alpha} materials, a known-{alpha} approach may be adopted. In this method, {alpha} is determined for a single item using a combination of gamma-ray and calorimetric measurements. Because calorimetry is based on heat output, rather than a statistical distribution of emitted neutrons, an {alpha}-value determined in this way is far more accurate than one determined from passive neutron counts. This fixed {alpha} value can be used in conventional multiplicity analysis for any plutonium-bearing item having the same chemical composition and isotopic distribution as the original. With the results of single calorimeter/passive neutron/gamma-ray measurement, these subsequent items can then be assayed with high precision and accuracy in a relatively short time, despite the presence of impurities. A calorimeter-based known-{alpha} multiplicity analysis technique is especially useful when requiring rapid, high accuracy, high precision measurements of multiple plutonium bearing items having a common source. The technique has therefore found numerous applications at the Savannah River Site. In each case, a plutonium (or mixed U/Pu) bearing item is divided into multiple containers. A single item from that batch is then selected for both neutron and calorimetric measurements; all remaining items undergo a neutron measurement only. Using the technique mentioned above, the 'true' {alpha} value determined from the first (calorimeter and passive neutron measured) item is used in multiplicity analysis for all other items in the batch. The justification for using this {alpha} value in subsequent calculations is the assumption that the chemical composition and isotopic distribution of all batch items are the same, giving a constant ({alpha},n):spontaneous fission ratio. This analysis method has been successfully applied to the KIS Facility, significantly improving measurement uncertainties and reducing processing times for numerous items. Comprehensive plans were later developed to extend the use of this method to other applications, including the K-Area Shuffler and the H-Area Pu-Blending Project. While only the feasibility study for the Shuffler has been completed, implementation of the method in the H-Area Pu-Blending Project is currently in progress and has been successfully applied to multiple items. This report serves to document the details of this method in order to serve as a reference for future applications. Also contained herein are specific examples of the application of known-{alpha} multiplicity analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Singular perturbation techniques in the gravitational self-force problem

Much of the progress in the gravitational self-force problem has involved the use of singular perturbation techniques. Yet the formalism underlying these techniques is not widely known. I remedy this situation by explicating the foundations and geometrical structure of singular perturbation theory in general relativity. Within that context, I sketch precise formulations of the methods used in the self-force problem: dual expansions (including matched asymptotic expansions), for which I identify precise matching conditions, one of which is a weak condition arising only when multiple coordinate systems are used; multiscale expansions, for which I provide a covariant formulation; and a self-consistent expansion with a fixed worldline, for which I provide a precise statement of the exact problem and its approximation. I then present a detailed analysis of matched asymptotic expansions as they have been utilized in calculating the self-force. Typically, the method has relied on a weak matching condition, which I show cannot determine a unique equation of motion. I formulate a refined condition that is sufficient to determine such an equation. However, I conclude that the method yields significantly weaker results than do alternative methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum error correction in the black hole interior

We study the quantum error correction properties of the black hole interior in a toy model for an evaporating black hole: Jackiw-Teitelboim gravity entangled with a non-gravitational bath. After the Page time, the black hole interior degrees of freedom in this system are encoded in the bath Hilbert space. We use the gravitational path integral to show that the interior density matrix is correctable against the action of quantum operations on the bath which (i) do not have prior access to details of the black hole microstates, and (ii) do not have a large, negative coherent information with respect to the maximally mixed state on the bath, with the lower bound controlled by the black hole entropy and code subspace dimension. Thus, the encoding of the black hole interior in the radiation is robust against generic, low-rank quantum operations. For erasure errors, gravity comes within an O (1) distance of saturating the Singleton bound on the tolerance of error correcting codes. For typical errors in the bath to corrupt the interior, they must have a rank that is a large multiple of the bath Hilbert space dimension, with the precise coefficient set by the black hole entropy and code subspace dimension.

2D gravity↗

High-precision determination of iron oxidation state in silicate glasses using XANES

Fe K-edge X-ray absorption near-edge structure (XANES) and Moessbauer spectra were collected on natural basaltic glasses equilibrated over a range of oxygen fugacity (QFM - 3.5 to QFM + 4.5). The basalt compositions and fO{sub 2} conditions were chosen to bracket the natural range of redox conditions expected for basalts from mid-ocean ridge, ocean island, back-arc basin, and arc settings, in order to develop a high-precision calibration for the determination of Fe{sup 3+}/{Sigma}Fe in natural basalts. The pre-edge centroid energy, corresponding to the 1s {yields} 3d transition, was determined to be the most robust proxy for Fe oxidation state, affording significant advantages compared to the use of other spectral features. A second-order polynomial models the correlation between the centroid and Fe{sup 3+}/{Sigma}Fe, yielding a precision of {+-} 0.0045 in Fe{sup 3+}/{Sigma}Fe for glasses with Fe{sup 3+}/{Sigma}Fe > 8%, which is comparable to the precision of wet chemistry. This high precision relies on a Si (311) monochromator to better define the Fe{sup 2+} and Fe{sup 3+} transitions, accurate and robust modeling of the pre-edge feature, dense fO{sub 2}-coverage and compositional appropriateness of reference glasses, and application of a non-linear drift correction. Through re-analysis of the reference glasses across three synchrotron beam sessions, we show that the quoted precision can be achieved (i.e., analyses are reproducible) across multiple synchrotron beam sessions, even when spectral collection conditions (detector parameters or sample geometry) change. Rhyolitic glasses were also analyzed and yield a higher centroid energy at a given Fe{sup 3+}/{Sigma}Fe than basalts, implying that major variations in melt structure affect the relationship between centroid position and Fe{sup 3+}/{Sigma}Fe, and that separate calibrations are needed for the determination of oxidation state in basalts and rhyolites.

43 PARTICLE ACCELERATORS↗