Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

LANDSAT-4 Thematic Mapper Calibration and Atmospheric Correction

In order to utilize the quantitative accuracy built into the Thematic Mapper effectively, more attention must be paid to calibration before launch, changes of calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Recent experience with the Coastal Zone Color Scanner (CZCS) program has led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wave lengths, with lesser changes as wave length increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, will give an accurate correction for this portion of the atmospheric contribution to the signal.

Hovis, W. A.↗

Profile modeling for crop discrimination

A complete automatic unsupervised classification approach has been developed to estimate the proportion of corn, soybeans, and other crops in a Landsat 5-by-6-nanometer segment. The technique involves extracting crop growth variables that are predictable from agromet models, it provides a signature extension not possible before. The technique has been applied in 3 years (1978-1980) for 56 segments and shows neither a year-to-year effect nor any geographic effect. The results to date are considered far better than those obtainable from any other currently available technique. Nontheless, the technique can be improved to reduce the bias.

Badhwar, G. D.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

Observational parameters for remote sensing in the next decade

The spectral and spatial requirements for remote sensing in the next decade are presented. The requirements presented were obtained through extensive literature research and discussions with leading members of the various remote sensing research communities. In the 0.35-2.5 micron region of the spectrum, numerous bands will be needed at bandwidths as narrow as 10-20 nanometers. There is also growing interest in the thermal infrared (8-14 microns). Spatial resolution (instantaneous field of view) of 5 to 10 meters will be of great benefit to many fields of remote sensing.

Vane, G.↗

Liquid chromatographic analysis of a formulated ester from a gas-turbine engine test

Size exclusion chromatography (SEC) utilizing mu-Bondagel and mu-Styragel columns with a tetrahydrofuran mobile phase was used to determine the chemical degradation of lubricant samples from a gas-turbine engine test. A MIL-L-27502 candidate, ester-based lubricant was run in a J57-29 engine at a bulk oil temperature of 216 C. In general, the analyses indicated a progressive loss of primary ester, additive depletion, and formation of higher molecular weight material. An oil sample taken at the conclusion of the test showed a reversal of this trend because of large additions of new oil. The high-molecular-weight product from the degraded ester absorbed strongly in the ultraviolet region at 254 nanometers. This would indicate the presence of chromophoric groups. An analysis of a similar ester lubricant from a separate high-temperature bearing test yielded qualitatively similar results.

Jones, W. R., Jr.↗

Observed ozone response to variations in solar ultraviolet radiation

During the winter of 1979, the solar ultraviolet irradiance varied with a period of 13.5 days and an amplitude of 1 percent. The zonal mean ozone values in the tropics varied with the solar irradiance, with an amplitude of 0.25 to 0.60 percent. This observation agrees with earlier calculations, although the response may be overestimated. These results imply changes in ozone at an altitude of 48 kilometers of up to 12 percent over an 11-year solar cycle. Interpretation of ozone changes in the upper stratosphere will require measurements of solar ultraviolet radiation at wavelengths near 200 nanometers.

Gille, J. C.↗

LANDSAT-4 Thematic Mapper Calibration and Atmospheric Correction

The LANDSAT-4 thematic mapper, with its wide spectral coverage and digitization to 8 bits per word, is a large step forward in the direction of quantitative radiometry from the multispectral scanner (MSS). In order to utilize the quantitative accuracy built into the thematic mapper effectively, more attention must be paid to calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Experience with the coastal zone color scanner (CZCS) program led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances, despite errors in sensor calibration, solar spectral irradiance measurements, and reported values of Rayleigh optical depth. These techniques offer sensitive tests for change in calibration, especially at shorter wavelengths. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wavelengths, with lesser changes as wavelength increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, should give an accurate correction for this portion of the atmospheric contribution to the signal.

Hovis, W. A.↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, W. T.↗

Airborne imaging spectrometer - A new tool for remote sensing

The first of a new class of remote sensing instruments is described. The Airborne Imaging Spectrometer represents the first use of two-dimensional area arrays in a scientific application. The instrument images 32 cross-track pixels simultaneously, each in 128 spectral bands in the 1.2 to 2.4 micro region. The IFOV of the instrument is 1.9 mrad and the spectral sampling interval is 9.6 nanometers. Plans include upgrading the detector from the current 32 x 32 element HgCdTe CCD array to a 64 x 64 element array in 1984. Science and engineering data are currently being actively gathered with the instrument.

Vane, G.↗

Mechanical-contact-induced transformation from the amorphous to the partially crystalline state in metallic glass

Friction and wear tests were conducted with 3.2- and 6.4-millimeter-diameter aluminum oxide spheres sliding, in reciprocating motion, on a Fe67Co18B14Si1 metallic foil. Crystallites with a size range of 10 to 150 nanometers were produced on the wear surface of the amorphous alloy. A strong interaction between transition metals and metalloids such as silicon and boron results in strong segregation during repeated sliding, provides preferential transition metal-metalloid clustering in the amorphous alloy, and subsequently produces the diffused honeycomb structure formed by dark grey bands and primary crystals, that is, alpha-Fe in the matrix. Large plastic flow occurs on an amorphous alloy surface with sliding and the flow film of the alloy transfers to the aluminum oxide pin surface. Multiple slip bands due to shear deformation are observed on the side of the wear track. Two distinct types of wear debris were observed as a result of sliding: an alloy wear debris, and/or powdery-whiskery oxide debris.

Miyoshi, K.↗

Etching Silicon Films With Xenon Difluoride

Microscopic circuit structures prepared for probing. Xenon difluoride removes relatively large amounts of silicon from integratedcircuit or solar-cell structures while leaving SiO2, Si3N4, Al2O3, and other compounds intact. In Etching Apparatus, solid XeF2 sublimated in vacuum, then allowed to flow over sample at controlled rate and pressure. Wafer etched from back to expose SiO2 and Al layers for spectroscopic analysis of SiO2/Al interface. Using XeF2 technique, silicon wafer with oxide layer reduced in thickness from standard 300 micrometer to as little as 10 nanometer without adversely affecting oxide.

Hecht, M. H.↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, B.↗

Structural characterization and gas reactions of small metal particles by high-resolution TEM and TED

The interaction of 100 and 200 keV electron beams with amorphous alumina, titania, and aluminum nitride substrates and nanometer-size palladium particulate deposits was investigated for the two extreme cases of (1) large-area electron-beam flash-heating and (2) small-area high-intensity electron-beam irradiation. The former simulates a short-term heating effect with minimum electron irradiation exposure, the latter simulates high-dosage irradiation with minimum heating effect. All alumina and titania samples responded to the flash-heating treatment with significant recrystallization. However, the size, crystal structure, shape, and orientation of the grains depended on the type and thickness of the films and the thickness of the Pd deposit. High-dosage electron irradiation also readily crystallized the alumina substrate films but did not affect the titania films. The alumina recrystallization products were usually either all in the alpha phase, or they were a mixture of small grains in a number of low-temperature phases including gamma, delta, kappa, beta, theta-alumina. Palladium deposits reacted heavily with the alumina substrates during either treatment, but they were very little effected when supported on titania. Both treatments had the same, less prominent localized crystallization effect on aluminum nitride films.

Heinemann, K.↗

Mechanical-contact-induced transformation from the amorphous to the partially crystalline state in metallic glass

Friction and wear tests were conducted with 3.2- and 6.4-millimeter-diameter aluminum oxide spheres sliding, in reciprocating motion, on a Fe67Co18B14Si1 metallic foil. Crystallites with a size range of 10 to 150 nanometers were produced on the wear surface of the amorphous alloy. A strong interaction between transition metals and metalloids such as silicon and boron results in strong segregation during repeated sliding, provides preferential transition metal-metalloid clustering in the amorphous alloy, and subsequently produces the diffused honeycomb structure formed by dark grey bands and primary crystals, that is, alpha-Fe in the matrix. Large plastic flow occurs on an amorphous alloy surface with sliding and the flow film of the alloy transfers to the aluminum oxide pin surface. Multiple slip bands due to shear deformation are observed on the side of the wear track. Two distinct types of wear debris were observed as a result of sliding: an alloy wear debris, and/or powdery-whiskery oxide debris.

Miyoshi, K.↗

Multiband selection device

Current science projections for future earth-imaging instruments indicate the need for as many as 25 spectral bands, with bandwidths as narrow as 20 nanometers. The desire for a multiplicity of bands has led researchers to study various spectrally dispersive instrument designs as a means of providing the desired future capability. These instrument designs, however, are costly, complex, and of high technical risk. This paper describes a 'multiband selection device' containing several spectral filters that can be placed at the exit faces of a broadband multiport beam splitter and thereby provide a multiplicity of spectral bands with a high degree of spatial coregistration while utilizing state-of-the-art linear array detectors. Fabrication of the multiband selection device has been successfully accomplished, and the design and test results are described.

Richard, H. L.↗

Direct investigation of subsurface interface electronic structure by ballistic-electron-emission microscopy

A new technique for spectroscopic investigation of subsurface interface electronic structure has been developed. The method, ballistic-electron-emission microscopy (BEEM), is based on scanning tunneling microscopy. BEEM makes possible, for the first time, direct imaging of subsurface interface properties with nanometer spatial resolution. The first application of BEEM to subsurface Schottky-barrier interfaces is reported.

Kaiser, W. J.↗

A new laboratory source of ozone and its potential atmospheric implications

Although 248-nm radiation falls 0.12 eV short of the energy needed to dissociate O2, large densities of ozone (O3) can be produced from unfocused 248-nm KrF excimer laser irradiation of pure O2. As soon as any O3 is present, it strongly absorbs the 248-nanometer radiation and dissociates to vibrationally excited ground state O2 (among other products), with a quantum yield of 0.1 to 0.15. During the laser pulse, a portion of these molecules absorb a photon and dissociate, which results in the production of three oxygen atoms for one O3 molecule destroyed. Recombination then converts these atoms to O3, and thus O3 production in the system is autocatalytic. A deficiency exists in current models of O3 photochemistry in the upper stratosphere and mesosphere, in that more O3 is found than can be explained. A detailed analysis of the system as it applies to the upper atmosphere is not yet possible, but with reasonable assumptions about O2 vibrational distributions resulting from O3 photodissociation and about relaxation rates of vibrationally excited O2, a case can be made for the importance of including this mechanism in the models.

Slanger, T. G.↗

Plume spectrometry for liquid rocket engine health monitoring

An investigation of Space Shuttle Main Engine (SSME) testing failures identified optical events which appeared to be precursors of those failures. A program was therefore undertaken to detect plume trace phenomena characteristic of the engine and to design a monitoring system, responsive to excessive activity in the plume, capable of delivering a warning of an anomalous condition. By sensing the amount of extraneous material entrained in the plume and considering engine history, it may be possible to identify wearing of failing components in time for a safe shutdown and thus prevent a catastrophic event. To investigate the possibilities of safe shutdown and thus prevent a monitor to initiate the shutdown procedure, a large amount of plume data were taken from SSME firings using laboratory instrumentation. Those data were used to design a more specialized instrument dedicated to rocket plume diagnostics. The spectral wavelength range of the baseline data was about 220 nanometers (nm) to 15 micrometer with special attention given to visible and near UV. The data indicates that a satisfactory design will include a polychromator covering the range of 250 nM to 1000 nM, along with a continuous coverage spectrometer, each having a resolution of at least 5A degrees. The concurrent requirements for high resolution and broad coverage are normally at odds with one another in commercial instruments, therefore necessitating the development of special instrumentation. The design of a polychromator is reviewed herein, with a detailed discussion of the continuous coverage spectrometer delayed to a later forum. The program also requires the development of applications software providing detection, variable background discrimination, noise reduction, filtering, and decision making based on varying historical data.

Powers, William T.↗