Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanosecond pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Thermal Properties of Polymer Hole-Transport Layers Influence the Efficiency Roll-off and Stability of Perovskite Light-Emitting Diodes

While the performance of metal halide perovskite light-emitting diodes (PeLEDs) has rapidly improved in recent years, their stability remains a bottleneck to commercial realization. Here, we show that the thermal stability of polymer hole-transport layers (HTLs) used in PeLEDs represents an important factor influencing the external quantum efficiency (EQE) roll-off and device lifetime. We demonstrate a reduced EQE roll-off, a higher breakdown current density of approximately 6 A cm -2 , a maximum radiance of 760 W sr -1 m -2 , and a longer device lifetime for PeLEDs using polymer HTLs with high glass-transition temperatures. Furthermore, for devices driven by nanosecond electrical pulses, a record high radiance of 1.23 MW sr -1 m -2 and an EQE of approximately 1.92% at 14.6 kA cm -2 are achieved. Thermally stable polymer HTLs enable stable operation of PeLEDs that can sustain more than 11.7 million electrical pulses at 1 kA cm -2 before device failure.

14 SOLAR ENERGY↗

Electrical manipulation of skyrmions in a chiral magnet

Writing, erasing and computing are three fundamental operations required by any working electronic device. Magnetic skyrmions could be essential bits in promising in emerging topological spintronic devices. In particular, skyrmions in chiral magnets have outstanding properties like compact texture, uniform size, and high mobility. However, creating, deleting, and driving isolated skyrmions, as prototypes of aforementioned basic operations, have been a grand challenge in chiral magnets ever since the discovery of skyrmions, and achieving all these three operations in a single device is even more challenging. Here, by engineering chiral magnet Co 8 Zn 10 Mn 2 into the customized micro-devices for in-situ Lorentz transmission electron microscopy observations, we implement these three operations of skyrmions using nanosecond current pulses with a low current density of about 10 10 A·m -2 at room temperature. A notched structure can create or delete magnetic skyrmions depending on the direction and magnitude of current pulses. We further show that the magnetic skyrmions can be deterministically shifted step-by-step by current pulses, allowing the establishment of the universal current-velocity relationship. These experimental results have immediate significance towards the skyrmion-based memory or logic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time tracking of protein unfolding with time-resolved x-ray solution scattering

The correct folding of proteins is of paramount importance for their function, and protein misfolding is believed to be the primary cause of a wide range of diseases. Protein folding has been investigated with time-averaged methods and time-resolved spectroscopy, but observing the structural dynamics of the unfolding process in real-time is challenging. Here, we demonstrate an approach to directly reveal the structural changes in the unfolding reaction. We use nano- to millisecond time-resolved x-ray solution scattering to probe the unfolding of apomyoglobin. The unfolding reaction was triggered using a temperature jump, which was induced by a nanosecond laser pulse. We demonstrate a new strategy to interpret time-resolved x-ray solution scattering data, which evaluates ensembles of structures obtained from molecular dynamics simulations. We find that apomyoglobin passes three states when unfolding, which we characterize as native, molten globule, and unfolded. The molten globule dominates the population under the conditions investigated herein, whereas native and unfolded structures primarily contribute before the laser jump and 30 μs after it, respectively. The molten globule retains much of the native structure but shows a dynamic pattern of inter-residue contacts. Our study demonstrates a new strategy to directly observe structural changes over the cause of the unfolding reaction, providing time- and spatially resolved atomic details of the folding mechanism of globular proteins.

59 BASIC BIOLOGICAL SCIENCES↗

BioCARS: Synchrotron facility for probing structural dynamics of biological macromolecules

A major goal in biomedical science is to move beyond static images of proteins and other biological macromolecules to the internal dynamics underlying their function. This level of study is necessary to understand how these molecules work and to engineer new functions and modulators of function. Stemming from a visionary commitment to this problem by Keith Moffat decades ago, a community of structural biologists has now enabled a set of x-ray scattering technologies for observing intramolecular dynamics in biological macromolecules at atomic resolution and over the broad range of timescales over which motions are functionally relevant. Many of these techniques are provided by BioCARS, a cutting-edge synchrotron radiation facility built under Moffat leadership and located at the Advanced Photon Source at Argonne National Laboratory. BioCARS enables experimental studies of molecular dynamics with time resolutions spanning from 100 ps to seconds and provides both time-resolved x-ray crystallography and small- and wide-angle x-ray scattering. Structural changes can be initiated by several methods—UV/Vis pumping with tunable picosecond and nanosecond laser pulses, substrate diffusion, and global perturbations, such as electric field and temperature jumps. Studies of dynamics typically involve subtle perturbations to molecular structures, requiring specialized computational techniques for data processing and interpretation. In this review, we present the challenges in experimental macromolecular dynamics and describe the current state of experimental capabilities at this facility. As Moffat imagined years ago, BioCARS is now positioned to catalyze the scientific community to make fundamental advances in understanding proteins and other complex biological macromolecules.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic field effects on laser energy deposition and filamentation in magneto-inertial fusion relevant plasmas

We report on experimental measurements of how an externally imposed magnetic field affects plasma heating by kJ-class, nanosecond laser pulses. The experiments reported here took place in gas cells analogous to magnetized liner inertial fusion targets. We observed significant changes in laser propagation and energy deposition scale lengths when a 12T external magnetic field was imposed in the gas cell. We find evidence that the axial magnetic field reduces radial electron thermal transport, narrows the width of the heated plasma, and increases the axial plasma length. Reduced thermal conductivity increases radial thermal gradients. This enhances radial hydrodynamic expansion and subsequent thermal self-focusing. Our experiments and supporting 3D simulations in helium demonstrate that magnetization leads to higher thermal gradients, higher peak temperatures, more rapid blast wave development, and beam focusing with an applied field of 12T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven quasi-static B-fields for magnetized high-energy-density experiments

We present measurements of magnetic fields generated in laser-driven coil targets irradiated by laser pulses of nanosecond duration, 1.053 μm wavelength, 500 J energy, and ∼1015 W/cm2 intensity, at the LULI2000 facility. Using two perpendicular probing axes, proton deflectometry is used to characterize the coil current and static charge at different times. Results reveal various deflection features that can be unambiguously linked to a looping quasi-steady current of well-understood polarity or to a static charging of the coil surface. Measured currents are broadly consistent with predictions from a laser-driven diode-current source and lumped circuit model, supporting the quasi-steady assessment of the discharges. Peak magnetic fields of ∼50 T at the center of 500-μm-diameter coils, obtained at the moderate laser intensity, open up the use of such laser-driven coil targets at facilities worldwide to study numerous phenomena in magnetized high-energy-density plasmas, and its potential applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

White-line evolution in shocked solid Ta evidenced by synchrotron x-ray absorption spectroscopy

Time-resolved x-ray absorption experiments have been performed on shocked tantalum. Using a single 100 ps synchrotron x-ray pulse, nanosecond-lived equilibrium states of shocked solid Ta have been measured by L 3 -edge absorption spectroscopy. The energy shift and intensity change of the white line were measured up to 130 GPa and 2000 K. The experimental results are discussed in light of density functional theory calculations and FEFF simulations. Lastly, the absence of occurrence of the hcp-ω phase is suggested from the analysis of the shape of the white line.

36 MATERIALS SCIENCE↗

Voltage Loss Comparison in CdSe/CdTe Solar Cells and Polycrystalline CdSeTe Heterostructures

Cd(Se)Te solar cells have considerable headroom to increase voltage. Voltage losses occur due to incomplete absorption above bandgap E_g and band tail absorption below E_g; such losses are quantified using radiative voltage. The largest voltage losses are attributed to nonradiative recombination, which is quantified via carrier lifetime and radiative efficiency. We compare radiative voltage, radiative efficiency, and carrier lifetime for Cu-doped CdSe/CdTe solar cells and for undoped polycrystalline CdSeTe heterostructures passivated with Al_2O_3. Using external quantum efficiency spectrum and a CdSeTe absorption spectrum obtained from absolute photoluminescence (PL), we show that the radiative voltage is greater than 1.1 V. Time-resolved PL experiments and modeling show that a major part of voltage losses can be attributed to recombination in the absorber bulk. The front interface recombination makes a larger impact within the first few nanoseconds after pulsed excitation, and the comparison of time-gated and time-integrated PL can be used to assess relative contributions of front interface and bulk recombination rates.

14 SOLAR ENERGY↗

Investigation of the effects of passive pre-chamber nozzle pattern and ignition system on engine performance and emissions

The impact of passive pre-chamber (PC) internal volume, nozzle hole pattern (i.e. with and without a central axial nozzle), and PC igniter plug type on performance and emissions was investigated in an optically accessible, single-cylinder, gasoline research engine. The two PC igniter plugs investigated were a conventional inductive coil spark plug and a nanosecond repetitively pulsed (NRP) plasma discharge system previously demonstrated to accelerate early flame propagation. The baseline PC design featured a funnel shaped internal volume with a PC tip that contained six radial nozzles and a larger central axial nozzle. Two additional PC tip geometries were evaluated where either the baseline internal volume was increased or the axial nozzle was removed and the radial nozzle diameters were increased. A sweep of charge equivalence ratios ( ϕ) from nearly stoichiometric to the lean limit was performed for a fixed engine speed (1300 revolutions per minute), and engine load (3.5 bar gross indicated mean effective pressure). Time-resolved PC and main chamber (MC) pressure data as well as MC emissions data were collected to analyze engine performance and emissions characteristics. Combustion in the MC was further investigated using high-speed excited methylidyne radical (CH*) chemiluminescence imaging. Collected results highlighted that while all PC tips and ignition systems exhibited similar performance and emissions down to ϕ = 0.8, relevant differences in thermal efficiency and emissions for leaner charge mixtures were observed, with the results highly dependent on the nozzle pattern and ignition system. Major deviations were correlated to preferential de-pressurization of the PC through the axial nozzle for lean conditions that was not observed for mixture conditions closer to stoichiometric. Results show that a combination of radial and axial nozzle patterns in the PC extended lean-stability limits at the low-load condition evaluated. Further benefits were observed with the use of NRP ignition systems due to faster combustion within the PC volume provided that the volume was sufficiently large.

Di Sabatino, Francesco↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.

43 PARTICLE ACCELERATORS↗

Nanosecond radar observations of the ocean surface from a stable platform

The measurement of ocean surface waves with a nanosecond radar pulse from a fixed platform at vertical incidence is discussed. By reducing the pulse width of radar until the pulse width resolves the vertical water wave structure, a set of radar returns is available to describe the ocean surface characteristics which differs from returns obtained by conventional radars. A block diagram of the radar and the principles of operation are presented.

Yaplee, B. S.↗

Stimulated Raman-scattering threshold behavior of binary mixture micrometer-sized droplets

Stimulated Raman scattering (SRS) from binary liquid mixture micrometer-sized droplets irradiated by nanosecond laser pulses exhibits previously unreported features. SRS emission at wavelength shifts corresponding to combination frequencies of the individual component Stokes shifts are observed in droplets but not in bulk mixtures. Furthermore, droplet SRS thresholds are determined by component refractive indices and concentrations, in contrast to bulk thresholds, for which self-focusing likely plays a dominant role.

Biswas, Abhijit↗

Ranging performance of satellite laser altimeters

Topographic mapping of the earth, moon and planets can be accomplished with high resolution and accuracy using satellite laser altimeters. These systems employ nanosecond laser pulses and microradian beam divergences to achieve submeter vertical range resolution from orbital altitudes of several hundred kilometers. Here, we develop detailed expressions for the range and pulse width measurement accuracies and use the results to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. Our analysis includes the effects of the target surface characteristics, spacecraft pointing jitter and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 mu rad or less.

Gardner, Chester S.↗

CHOMPTT (CubeSat Handling of Multisystem Precision Timing Transfer): From Concept to Launch Pad

Here we present the evolution of a student satellite mission: CHOMPTT (CubeSat Handling of Multisystem Precision Time Transfer), from its original concept as a candidate for the University NanoSatellite Program 8 (UNP8), to a spacecraft ready for launch in Fall of 2017 on ELaNa XIX (Educational Launch of Nanosatellites). The 3U CubeSat houses a 1 kg, 1U OPTI (Optical Precision Timing Instrument) payload, designed and built at the University of Florida, and a 1.5U EDSNNODeS-derived bus from NASA Ames Research Center. The OPTI payload comprises of: 1) a supervisor board that handles payload data, power regulation, and mode settings, 2) an optics assembly of six 1 cm retroreflectors and four laser beacon diodes for ground-tracking; and 3) two fully redundant timing channels, each consisting of: a chip-scale atomic clock, a microprocessor with clock counter, a picosecond event timer, and an avalanche photodetector (APD) with band-pass filter. Several iterations of OPTI have been developed, tested, and designed to achieve its current functionality and design a laboratory breadboard design, a 1.5U high altitude balloon design, engineering unit design, and its current flight unit design. In-lab testing of the current OPTI design indicates a short-term precision of 100 ps, equivalent to a range accuracy of 3 cm necessary to achieve our primary objective of 200 ps time transfer error, and a long-term timing accuracy of 20 ns over one orbit (1.5 hours). After the spacecraft reaches its nominal 500 km orbit at a 85 degree inclination, an experimental laser ranging facility at Kennedy Space Center in Florida, will track and emit 1064 nm nanosecond optical pulses at the CHOMPTT spacecraft. The laser pulses will then reflect off the retroreflector array mounted on the nadir face of CHOMPTT, and return the pulse to the laser ranging facility where the laser ranging facility will record the round-trip duration of the laser pulses. At the same time the pulse arrives at the spacecraft and is reflected by the array, an APD will record the arrival time of the pulses at the nanosatellite. By comparing the arrival of the pulse at the CubeSat and the duration of the round-trip of the laser pulse, the clock discrepancy between the ground and CubeSat atomic clocks can be determined, in addition to the CubeSats range from the facility. The design and verification of the flight version of CHOMPTT will be reviewed and an overview of the lifetime development and progression of CHOMPTT from the inception to launch pad will be presented.

CHOMPTT↗

Plasma Activated Water for Crewed Transit and Planetary Habitation: A Study of Gas Type, Electrode Material, and Power Supply Selection and the Impact on the Final Frontier - FY21 CIF

An in-depth study of plasma activated water (PAW) generation was conducted to link changes in power supply, electrode material, input gas, and treatment time to the resulting reaction chemistry. These changes in chemistry can help tailor PAW for different space applications. An AC, DC, and nanosecond (ns) pulsed power supply were each used to generate PAW with stainless steel, copper, tungsten, or platinum (Pt) electrodes while utilizing air, nitrogen (N2), carbon dioxide (CO2), helium (He), or argon (Ar) as the feed gas. Tap or deionized (DI) water was treated for 1 to 15 minutes, and the generated PAW was tested for changes in pH, conductivity, oxidation reduction potential, nitrates (NO3-), ammonium (NH4+), and peroxide. Calculations showed that the production of reactive nitrogen species was the leading cause of pH and conductivity changes. The DC generated air plasma was able to reduce the pH of DI water and generate NO3‑. The pulsed supply, operating at 20% of the input power of the DC supply, lowered the pH generated NO3‑. When a simulated Martian gas mixture of 95% CO2 and 5% N2 was used as the feed gas, NO3‑ was generated with the DC and pulsed supplies, respectively. Mixing PAW with plasma generated ash from inedible biomass allowed pH control, thus enhancing PAW’s potential use for sanitation applications. The large shift in pH was used to study sanitation effects of Escherichia coli (E. coli) reduction and Staphylococcus aureus (S. aureus), in which log reductions were found to be negligible. Additionally, the plasma generated ash in combination with PAW was also implemented in 10-day microgreen growth trials, in which PAW and ash resulted in quicker emergence of the microgreens compared to the standard growth conditions and comparable dry masses to Hoagland’s nutrient solution treated samples.

plasma activated water (PAW)↗