Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutrinoless double beta decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Search for two-neutrino double-beta decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba with the complete EXO-200 dataset*

A new search for two-neutrino double-beta (2νββ) decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90% confidence level half-life sensitivity of 2νββ decay to the $0$$^{+}_{1}$ state of 136 Ba is 2.9 x 10 24 yr using a total 136 Xe exposure of 234.1 kg yr. Furthermore, no statistically significant evidence for 2νββ decay to the $0$$^{+}_{1}$ state is observed, leading to a lower limit of $T$$^{2v}_{1/2}$(0 + → $0$$^{+}_{1}$) > 1.4 x 10 24 yr at 90% confidence level, improved by 70% relative to the current world's best constraint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CUORE: The first bolometric experiment at the ton scale for the search for neutrino-less double beta decay

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most massive bolometric experiment searching for neutrino-less double beta (0νββ) decay. The detector consists of an array of 988 TeO 2 crystals (742 kg) arranged in a compact cylindrical structure of 19 towers. Here, this paper will describe the CUORE experiment, including the cryostat, and present the detector performance during the first year of running. Additional detail will describe the effort made in improving the energy resolution in the 130 Te 0νββ decay region of interest (ROI) and the suppression of backgrounds. A description of work to lower the energy threshold in order to give CUORE the sensitivity to search for other rare events, such as dark matter, will also be provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-β decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work, we showcase light detectors based on an alternative Ir-Pt bilayer transition-edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of < 100 eV rms. Our detectors have risetimes of approximately 180μs and measured timing jitter of < 20μs for the expected signal to noise at the Q value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-β decay pile-up events. In conclusion, the current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Large Enriched Germanium Experiment for Neutrinoless ββ Decay (LEGEND-1000 Preconceptual Design Report)

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless ββ Decay. This experiment is an international project designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the 76 Ge isotope of interest operated in a liquid argon active shield at a deep underground lab. The experiment is designed to achieve a discovery potential that covers the inverted-ordering neutrino mass scale region. The baseline design assumes installation in the SNOLAB cryopit. A similar experimental setup could also be realized at the LNGS alternative site.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical analysis for the neutrinoless double-β-decay matrix element of 48 Ca

Neutrinoless double-β-decay (0⁢vββ) nuclear matrix elements (NME) are the object of many theoretical calculation methods, and are very important for analysis and guidance of a large number of experimental efforts. However, there are large discrepancies between the NME values provided by different methods. Here, in this paper, we propose a statistical analysis of the 48 Ca 0v⁢ββ NME using the interacting shell model, emphasizing the range of the NME probable values and their correlations with observables that can be obtained from the existing nuclear data. Based on this statistical analysis with three independent effective Hamiltonians, we propose a common probability distribution function for the 0⁢vββ NME, which has a range of (0.45–0.95) at 90% confidence level, and a mean value of 0.68.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large- N c analysis of two-nucleon neutrinoless double-β decay and charge-independence-breaking contact terms

The interpretation of experiments that search for neutrinoless double- β decay relies on input from nuclear theory. Cirigliano et al. [Phys. Rev. Lett. 120, 202001 (2018)] recently showed that, for the light Majorana exchange formalism, effective field theory calculations require a nn → ppe - e - contact term at leading order. They estimated the size of this contribution by relating it to measured charge-independence-breaking (CIB) nucleon-nucleon interactions and making an assumption about the relative sizes of CIB operators. We show that the assumptions underlying this approximation are justified in the limit of the number of colors, N c , being large. Finally, we also obtain a large-N c hierarchy among CIB nucleon-nucleon interactions that is in agreement with phenomenological results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive study of radon progeny attachment to surfaces

Low energy, low rate experiments, such as searches for neutrinoless double β decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. 210 Po driven, neutron induced background, caused by nuclear (α, n) reactions on low-Z materials, direct background contributions of the 210 Po α radiation and desorption of the 210 Pb progeny 210 Bi from surfaces into the detector medium are of particular of concern. These backgrounds depend on details of the components’ exposure to radon-loaded laboratory air and, thus, their handling history. The attachment rates of airborne radon progeny to surfaces, needed for the estimation of these background rates, are poorly understood. This article reports the results of a campaign comprising of more than 1200 attachment measurements, performed for nine different materials. Correlations of the attachment with environmental parameters such as air exchange rate, electrical surface potential, temperature, atmospheric pressure, and relative humidity have been studied and found to be significant only in case of the first two. Attachment modeling, using the Jacobi model, is compared to data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent charge barrier height of amorphous germanium contact detector

The exploration of germanium (Ge) detectors with amorphous Ge (a-Ge) contacts has drawn attention to the searches for rare-event physics such as dark matter and neutrinoless double-beta decay. The charge barrier height (CBH) of the a-Ge contacts deposited on the detector surface is crucial to suppress the leakage current of the detector in order to achieve a low-energy detection threshold and high-energy resolution. The temperature-dependent CBH of a-Ge contacts for three Ge detectors is analyzed to study the bulk leakage current (BLC) characteristics. The detectors were fabricated at the University of South Dakota using homegrown crystals. The CBH is determined from the BLC when the detectors are operated in the reverse bias mode with a guard-ring structure, which separates the BLC from the surface leakage current (SLC). Here the results show that CBH is temperature dependent. The direct relation of the CBH variation to temperature is related to the barrier inhomogeneities created on the interface of a-Ge and crystalline Ge. The inhomogeneities that occur at the interface were analyzed using the Gaussian distribution model for three detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. Furthermore, this paper describes this database application, explains how it functions, and discusses how it streamlines the design of the experiment.

47 OTHER INSTRUMENTATION↗

Demonstration of Selective Single-Barium Ion Detection with Dry Diazacrown Ether Naphthalimide Turn-on Chemosensors

Single-molecule fluorescence imaging (SMFI) of gas-phase ions has been proposed for “barium tagging,” a burgeoning area of research in particle physics to detect individual barium daughter ions. This has potential to significantly enhance the sensitivity of searches for neutrinoless double-beta decay (0νββ) that is obscured by background radiation events. The chemistry required to make such sensitive detection of Ba 2+ by SMFI in dry Xe gas at solid interfaces has implications for solid-phase detection methods but has not been demonstrated. Here, we synthesized simple, robust, and effective Ba 2+ -selective chemosensors capable of function within ultrapure high-pressure 136 Xe gas. Turn-on fluorescent naphthalimide-(di)azacrown ether chemosensors were Ba 2+ -selective and achieved SMFI in a polyacrylamide matrix. Here, fluorescence and NMR experiments supported a photoinduced electron transfer mechanism for turn-on sensing. Ba 2+ selectivity was achieved with computational calculations correctly predicting the fluorescence responses of sensors to barium, mercury, and potassium ions. With these molecules, dry-phase single-Ba 2+ ion imaging with turn-on fluorescence was realized using an oil-free microscopy technique for the first time—a significant advance toward single-Ba 2+ ion detection within large volumes of 136 Xe, plausibly enabling a background-independent technique to search for the hypothetical process of 0νββ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter–antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ) decay. Here we show results from the search for 0νββ decay of 130 Te, using the latest advanced cryogenic calorimeters with the CUORE experiment3. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultralow temperatures, operational longevity, and the low levels of ionizing radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ decay and set a lower bound of the process half-life as 2.2 × 10 25 years at a 90 percent credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultralow-temperature cryogenic environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ( 0νββ ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0νββ decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0νββ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

experimental nuclear physics↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗