Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron shield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Light Ion Double-Differential Cross Sections for Space Radiation

Neutrons and light ions have been shown to make large contributions to space radiation dose equivalent for realistic shielding scenarios. However, there are considerable uncertainties in the calculation of light ion production. Efficient and accurate calculation of light ion double-differential cross sections are required for input into space radiation transport codes. A thermal proton cross section model is developed which includes proton production from the 3 sources of projectile, central fireball, and target. It is shown that this 3-source model is able to explain the low-momentum, small-angle shoulder seen in proton spectra. Using the coalescence model, the thermal proton model is used to calculate light ion double-differential cross sections for use in space radiation transport codes. The 3-source model is also seen to be essential to explain the light ion shoulders, which are even more pronounced than the proton shoulders. Extensive comparisons between models and experimental measurements are shown and necessary future work is discussed.

Norbury, John W.↗

High-Energy Space Propulsion Based on Magnetized Target Fusion

Magnetized target fusion is an approach in which a magnetized target plasma is compressed inertially by an imploding material wall. A high energy plasma liner may be used to produce the required implosion. The plasma liner is formed by the merging of a number of high momentum plasma jets converging towards the center of a sphere where two compact toroids have been introduced. Preliminary 3-D hydrodynamics modeling results using the SPHINX code of Los Alamos National Laboratory have been very encouraging and confirm earlier theoretical expectations. The concept appears ready for experimental exploration and plans for doing so are being pursued. In this talk, we explore conceptually how this innovative fusion approach could be packaged for space propulsion for interplanetary travel. We discuss the generally generic components of a baseline propulsion concept including the fusion engine, high velocity plasma accelerators, generators of compact toroids using conical theta pinches, magnetic nozzle, neutron absorption blanket, tritium reprocessing system, shock absorber, magnetohydrodynamic generator, capacitor pulsed power system, thermal management system, and micrometeorite shields.

Thio, Y. C. F.↗

The Radiation Environment in Free Space and Inside Low-Earth Spacecraft's

There are three main sources of radiation in free space. These are the trapped protons and electrons, solar energetic particles, and the galactic cosmic rays. For human mission to Mars or moon, the trapped protons and electrons are of a minor concern. The flux of trapped particles at a fixed spacecraft altitude, and of galactic cosmic rays, decreases as the solar activity increases; however, the probability of a solar particle event increases as the solar activity increases. As these particles interact with the shielding material of the spacecraft and human body, they produce secondary particles, such as lighter fragments, target fragments, and neutrons. These particles can have far more damaging effect on cells than the primary particles. Thus, the radiation environment is very complex and varies with time. In this paper, we review the sources of charged-particles that contribute significantly to radiation risk to the astronauts, and estimates of exposure for some typical missions, such as Space Shuttle, International Space Station, and a human mission to Mars.

Badhwar, Gautam D.↗

Space Weather Nowcasting of Atmospheric Ionizing Radiation for Aviation Safety

There is a growing concern for the health and safety of commercial aircrew and passengers due to their exposure to ionizing radiation with high linear energy transfer (LET), particularly at high latitudes. The International Commission of Radiobiological Protection (ICRP), the EPA, and the FAA consider the crews of commercial aircraft as radiation workers. During solar energetic particle (SEP) events, radiation exposure can exceed annual limits, and the number of serious health effects is expected to be quite high if precautions are not taken. There is a need for a capability to monitor the real-time, global background radiations levels, from galactic cosmic rays (GCR), at commercial airline altitudes and to provide analytical input for airline operations decisions for altering flight paths and altitudes for the mitigation and reduction of radiation exposure levels during a SEP event. The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) model is new initiative to provide a global, real-time radiation dosimetry package for archiving and assessing the biologically harmful radiation exposure levels at commercial airline altitudes. The NAIRAS model brings to bear the best available suite of Sun-Earth observations and models for simulating the atmospheric ionizing radiation environment. Observations are utilized from ground (neutron monitors), from the atmosphere (the METO analysis), and from space (NASA/ACE and NOAA/GOES). Atmospheric observations provide the overhead shielding information and the ground- and space-based observations provide boundary conditions on the GCR and SEP energy flux distributions for transport and dosimetry simulations. Dose rates are calculated using the parametric AIR (Atmospheric Ionizing Radiation) model and the physics-based HZETRN (High Charge and Energy Transport) code. Empirical models of the near-Earth radiation environment (GCR/SEP energy flux distributions and geomagnetic cut-off rigidity) are benchmarked against the physics-based CMIT (Coupled Magnetosphere- Ionosphere-Thermosphere) and SEP-trajectory models.

Mertens, Christopher J.↗

Gravitational Waves and Gamma-Rays from a Binary Neutron Star Merger: GW170817 and GRB 170817A

On 2017 August 17, the gravitational-wave event GW170817 was observed by the Advanced LIGO and Virgo detectors, and the gamma-ray burst (GRB) GRB170817A was observed independently by the Fermi Gamma-ray Burst Monitor, and the Anti-Coincidence Shield for the Spectrometer for the International Gamma-Ray Astrophysics Laboratory. The probability of the near-simultaneous temporal and spatial observation of GRB 170817A and GW170817 occurring by chance is 5.0 x 10(exp -8). We therefore confirm binary neutron star mergers as a progenitor of short GRBs. The association of GW170817 and GRB 170817A provides new insight into fundamental physics and the origin of short GRBs. We use the observed time delay of (+1.74 +/- 0.05) s between GRB170817A and GW170817 to: (i) constrain the difference between the speed of gravity and the speed of light to be between -3 x 10(exp-16) times the speed of light, (ii) place new bounds on the violation of Lorentz invariance, (iii) present a new test of the equivalence principle by constraining the Shapiro delay between gravitational and electromagnetic radiation. We also use the time delay to constrain the size and bulk Lorentz factor of the region emitting the gamma-rays. GRB170817A is the closest short GRB with a known distance, but is between 2 and 6 orders of magnitude less energetic than other bursts with measured redshift. A new generation of gamma-ray detectors, and subthreshold searches in existing detectors, will be essential to detect similar short bursts at greater distances. Finally, we predict a joint detection rate for the Fermi Gamma-ray Burst Monitor and the Advanced LIGO and Virgo detectors of 0.1 - 1.4 per year during the 2018--2019 observing run and 0.3 - 1.7 per year at design sensitivity.

Gravitational wave↗

Preliminary Analysis: Am-241 RHU/TEG Electric Power Source for Nanosatellites

The Februay 2013 Space Works Commercial report indicates a strong increase in nano/microsatellite (1-50 kg) launch demand globally in future years. Nanosatellites (NanoSats) are small spacecraft in the 1-10 kg range, which present a simple, low-cost option for developing quickly-deployable satellites. CubeSats, a special category of NanoSats, are even being considered for interplanetary missions. However, the small dimensions of CubeSats and the limited mass of the NanoSat class in general place limits of capability on their electrical power systems (especially where typical power sources such as solar panels are considered) and stored energy reserves; restricting the power budget and overall functionality. For example, leveraging NanoSat clusters for computationally intensive problems that are solved collectively becomes more challenging with power related restrictions on communication and data-processing. Further, interplanetary missions that would take NanoSats far from the sun, make the use of solar panels less effective as a power source as their required area would become quite large. To overcome these limitations, americium 241 (Am-241) has been suggested as a low power source option. The Idaho National Laboratory, Center for Space Nuclear Research reports that:  (Production) requires small quantities of isotope - 62.5 g of Pu-238; 250 g Am- 241 (for 5 We); Am-241 is available at around 1 kg/yr commercially; Am-241 produces 59 kev gammas which are stopped readily by tungsten so the radiation field is very low. Whereby, an Am-241 source could be placed in among the instruments and the waste heat used to heat the platform; and  amounts of isotope are so low that launch approval may be easier, especially with tungsten encapsulation. As further reported, Am-241 has a half-life that is approximately five times greater than that of Pu- 238 and it has been determined that the neutron yield of a 241-AmO(sub 2) source is approximately an order of magnitude lower than that of a 238-PuO(sub 2) source of equal mass and degree of (sup 16)O enrichment. Also it has been demonstrated that shielded heat sources fuelled by oxygen-enriched 238-PuO(sub 2) have masses that are up to 10 times greater than those fuelled by oxygenenriched 241-AmO(sub 2) with equivalent thermal power outputs and neutron dose rates at 1 m radii. For these reasons, Am-241 is well suited to missions that demand long duration electrical power output, such as deep spaceflight missions and similar missions that use radiation-hard electronics and instrumentation that are less susceptible to neutron radiation damage.

Robertson, Glen A.↗

A high-resolution measurement of the 2.223 MeV neutron capture line in a solar flare

An intense solar flare lasting 40 s was observed by the HEAO 3 gamma-ray spectrometer on November 9, 1979, at 3:05 UT. The flare was observed in four high-resolution germanium detectors as well as in five CsI shield detectors over an energy range of 100 keV to above 5 MeV. Of particular interest is a line feature at 2.2248 + or - 0.0010 MeV. The precise energy measurement provides unambiguous evidence that this is the (H-1)(n, gamma)(H-2) line resulting from neutron capture on hydrogen. An upper limit of 5 keV is found for the natural line width. The time dependence of the neutron capture line is discussed as well as the overall characteristics of the November 9 flare.

Prince, T. A.↗

Monte-Carlo Simulations of Heavy Ions Track Structures and Applications

In space, astronauts are exposed to protons, high ]energy heavy (HZE) ions that have a high charge (Z) and energy (E), and secondary radiation, including neutrons and recoil nuclei produced by nuclear reactions in spacecraft walls or in tissue. The astronauts can only be partly shielded from these particles. Therefore, on travelling to Mars, it is estimated that every cell nucleus in an astronaut fs body would be hit by a proton or secondary electron (e.g., electrons of the target atoms ionized by the HZE ion) every few days and by an HZE ion about once a month. The risks related to these heavy ions are not well known and of concern for long duration space exploration missions. Medical ion therapy is another situation where human beings can be irradiated by heavy ions, usually to treat cancer. Heavy ions have a peculiar track structure characterized by high levels of energy ]deposition clustering, especially in near the track ends in the so ]called eBragg peak f region. In radiotherapy, these features of heavy ions can provide an improved dose conformation with respect to photons, also considering that the relative biological effectiveness (RBE) of therapeutic ions in the plateau region before the peak is sufficiently low. Therefore, several proton and carbon ion therapy facilities are under construction at this moment

Plante, Ianik↗

An Improved Neutron Transport Algorithm for Space Radiation

A low-energy neutron transport algorithm for use in space radiation protection is developed. The algorithm is based upon a multigroup analysis of the straight-ahead Boltzmann equation by using a mean value theorem for integrals. This analysis is accomplished by solving a realistic but simplified neutron transport test problem. The test problem is analyzed by using numerical and analytical procedures to obtain an accurate solution within specified error bounds. Results from the test problem are then used for determining mean values associated with rescattering terms that are associated with a multigroup solution of the straight-ahead Boltzmann equation. The algorithm is then coupled to the Langley HZETRN code through the evaporation source term. Evaluation of the neutron fluence generated by the solar particle event of February 23, 1956, for a water and an aluminum-water shield-target configuration is then compared with LAHET and MCNPX Monte Carlo code calculations for the same shield-target configuration. The algorithm developed showed a great improvement in results over the unmodified HZETRN solution. In addition, a two-directional solution of the evaporation source showed even further improvement of the fluence near the front of the water target where diffusion from the front surface is important.

Heinbockel, John H.↗

Radiation: Physical Characterization and Environmental Measurements

In this session, Session WP4, the discussion focuses on the following topics: Production of Neutrons from Interactions of GCR-Like Particles; Solar Particle Event Dose Distributions, Parameterization of Dose-Time Profiles; Assessment of Nuclear Events in the Body Produced by Neutrons and High-Energy Charged Particles; Ground-Based Simulations of Cosmic Ray Heavy Ion Interactions in Spacecraft and Planetary Habitat Shielding Materials; Radiation Measurements in Space Missions; Radiation Measurements in Civil Aircraft; Analysis of the Pre-Flight and Post-Flight Calibration Procedures Performed on the Liulin Space Radiation Dosimeter; and Radiation Environment Monitoring for Astronauts.

Source record↗

TPSAS-NF1676L-10829-DND

Galactic cosmic rays (GCR) and solar energetic particles (SEP) are the primary sources of human exposure to high linear energy transfer (LET) radiation in the atmosphere. High-LET radiation is effective at directly breaking DNA strands in biological tissue, or producing chemically active radicals in tissue that alter the cell function, both of which can lead to cancer or other adverse health effects. A prototype operational nowcast model of air-crew radiation exposure is currently under development and funded by NASA. The model predicts air-crew radiation exposure levels from both GCR and SEP that may accompany solar storms. The new air-crew radiation exposure model is called the Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) model. NAIRAS will provide global, data-driven, real-time exposure predictions of biologically harmful radiation at aviation altitudes. Observations are utilized from the ground (neutron monitors), from the atmosphere (the NCEP Global Forecast System), and from space (NASA/ACE and NOAA/GOES). Atmospheric observations characterize the overhead mass shielding and the ground- and space-based observations provide boundary conditions on the incident GCR and SEP particle flux distributions for transport and dosimetry calculations. Radiation exposure rates are calculated using the NASA physics-based HZETRN (High Charge (Z) and Energy TRaNsport) code. An overview of the NAIRAS model is given: the concept, design, prototype implementation status, data access, and example results. Issues encountered thus far and known and/or anticipated hurdles to research to operations transition are also discussed.

Christopher J Mertens↗

Large solar flare radiation shielding requirements for manned interplanetary missions

Estimates are given for the radiation shielding thicknesses required to protect astronauts on interplanetary missions from the effects of large solar flares, on the basis of the integral proton fluences for several past solar particle events. NASA-Langley's nucleon transport deterministic computer code, BRYNTRN, is used to transport primary protons and secondary protons and neutrons through any number of layers of target material of arbitrary thickness and composition. The results of each flare are presented as estimates of dose equivalents to the skin, eyes, and blood-forming organs behind various thicknesses of aluminum shielding.

Townsend, Lawrence W.↗

A study of heavy-heavy nuclear reactions

Calculations are presented for the reaction products in high energy collisions and of the atmospheric transport of particles such as protons, neutrons and other nucleons. The magnetic moments of charmed baryons are examined. Total cross sections which are required for cosmic heavy ion transport and shielding studies are also examined.

Khandelwal, G. S.↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

Induction of Micronuclei in Human Fibroblasts from the Los Alamos High Energy Neutron Beam

The space radiation field includes a broad spectrum of high energy neutrons. Interactions between these neutrons and a spacecraft, or other material, significantly contribute to the dose equivalent for astronauts. The 15 degree beam line in the Weapons Neutron Research beam at Los Alamos Nuclear Science Center generates a neutron spectrum relatively similar to that seen in space. Human foreskin fibroblast (AG1522) samples were irradiated behind 0 to 20 cm of water equivalent shielding. The cells were exposed to either a 0.05 or 0.2 Gy entrance dose. Following irradiation, micronuclei were counted to see how the water shield affects the beam and its damage to cell nuclei. Micronuclei induction was then compared with dose equivalent data provided from a tissue equivalent proportional counter.

Cox, Bradley↗