Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Supporting Data for "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mössbauer spectroscopy"

Contents of this DOI are data for the research paper "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mossbauer spectroscopy" by the authors: George Yumnam, et. al. The dataset contains data from inelastic x-ray scattering measurements of RuO2 single crystals performed at the Advanced Photon Source in Argonne National Lab. This dataset also contains data from inelastic neutron scattering experiments of RuO2 powder performed at the ARCS spectrometer at Spallation Neutron Source at ORNL. Supporting theoretical calculations based on density functional theory with r2SCAN and DFT+U methods is also included in this dataset. Please see the README.txt files for more information of the dataset and file contents. For comments and questions, please contact: George Yumnam (yumnamg@ornl.gov) and/or Raphael P Hermann (hermannrp@ornl.gov)

density functional theory↗

Supporting Data for "On the magnetic contribution of itinerant electrons to neutron diffraction in the topological antiferromagnet CeAlGe"

Contents of this DOI are data for the research paper "On the magnetic contribution of itinerant electrons to neutron diffraction in the topological antiferromagnet CeAlGe" by the authors: V. Pomjakushin et al. The dataset contains raw data from neutron scattering experiments of CeAlGe powder performed at the CNCS spectrometer at Spallation Neutron Source at ORNL.

36 MATERIALS SCIENCE↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Neutron Spectrum Determination for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a Multi-Sphere Spectrometer

This report presents the work that was performed to determine the neutron energy spectrum (spectrum) of the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) with a neutron Multi-Sphere Spectrometer (MSS). The spectrometer measurements were performed when the generator is in an INL Materials and Fuels Complex (MFC) laboratory. The measurements were used in a spectrum unfolding software to calculate the neutron spectrum. Based on initial testing of the MSS spectrometer and experience with the unfolding software, an MMRTG spectrum is reported and a justification for the spectrum is provided.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Solar neutron emissivity during the large flare on 1982 June 3

For the solar neutron event on June 3, 1982, it is shown here that the combined SMM Gamma Ray Spectrometer and Jungfraujoch neutron monitor data require a time-extended emission of neutrons at the sun with energies of 100 MeV to about 2 GeV. The solar neutron emissivity spectrum is shown to have a strong downward curvature or truncation between 2 and 4 GeV. A Bessel function and truncated power law give acceptable fits to the observational data, but only the power law can explain the rapid rise of the neutron monitor count rate. The integrated emissivity of neutrons above E(n) of 100 MeV is strongly constrained at 8 x 10 to the 28th neutrons/sr and is essentially independent of neutron spectral shape. At neutron energies of about 100 MeV, good agreement is found for both spectral forms with observations of neutron decay protons.

Chupp, E. L.↗

Segmented Ge detector rejection of internal beta activity produced by neutron irradiation

Future Ge spectrometers flown in space to observe cosmic gamma-ray sources will incorporate segmented detectors to reduce the background from radioactivity produced by energetic particle reactions. To demonstrate the effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity, a laboratory experiment has been carried out in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 (36.5 percent of natural Ge) in the detector itself, Ge-75 (t sub 1/2 = 82.78 min), which decays by beta emission with a maximum electron kinetic energy of 1188 keV. By requiring that an ionizing event deposit energy in two or more of the five segments of the detector, each about 1-cm thick, the beta particles, which have a range of about 1-mm, are rejected, while most external gamma rays incident on the detector are counted. Analysis of this experiment indicates that over 85 percent of the beta events from the decay of Ge-75 are rejected, which is in good agreement with Monte Carlo calculations.

Varnell, L. S.↗

Phonon density of states in uranium Laves phases UNi 2 and UCo 2

Recent computational work evaluated the phase stability of UCo 2 and UNi 2 in the C14, C15, and C36 Laves phases and reported their computationally determined phonon density of states. To corroborate these computational findings, we report the experimentally determined phonon density of states for UCo 2 and UNi 2 using inelastic neutron scattering at the wide angular-range chopper spectrometer at the Spallation Neutron Source at Oak Ridge National Laboratory. We found excellent agreement between experimental and computational results for UNi 2 and noted that some differences were observed for UCo 2 . Furthermore, by comparing the phonon density of states of UCo 2 with that of other U-bearing Laves phases, we found that UCo 2 showed distinct vibrational properties. From the one-phonon density of states, we calculated the lattice contribution to the specific heat of UNi 2 and UCo 2 . Finally, we bound the electronic contribution to the specific heat in UNi 2 .

Actinides↗

Inelastic Neutron Scattering Data for FeSn

Inelastic neutron scattering data from FeSn collected with the SEQUOIA spectrometer at the Spallation Neutron Source located at Oak Ridge National Laboratory. A 4.43 g sample of FeSn was used for the measurements as described in doi: https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data were collected with an incident energy of 500 meV. The Fermi chopper frequency was 480 Hz, which provides a resolution of 38.2 meV (FWHM) for elastic scattering. Additional details are available in https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data may be viewed and analyzed with the software packages Mantid (http://dx.doi.org/10.5286/SOFTWARE/MANTID) and Dave (doi: 10.6028/jres.114.025). Sample angles measured: -20 deg to 20 deg and 160 deg to 200 deg where 0 deg is defined for ki//c* Sample Orientation vectors: ‘u': '-0.0032, 0.0201, -1.0' ‘v': '-1.0, 0.0278, -0.0059'

Inelastic Neutron Scattering↗

NEAR Gamma Ray Spectrometer Characterization and Repair

This report covers the work completed in the third year of the contract. The principle activities during this period were (1) the characterization of the NEAR 2 Gamma Ray Spectrometer using a neutron generator to generate complex gamma ray spectra and a large Ge Detecter to identify all the major peaks in the spectra; (2) the evaluation and repair of the Engineering Model Unit of the Gamma Ray Spectrometer for the NEAR mission; (3) the investigation of polycapillary x-ray optics for x-ray detection; and (4) technology transfer from NASA to forensic science.

Groves, Joel Lee↗

First demonstration of a triton beam using target normal sheath acceleration

Tritiated titanium targets were irradiated by the short-pulse OMEGA EP laser (1.25 kJ, 10 ps) to generate a laser accelerated pulsed beam of tritons by target normal sheath acceleration. Using a Thomson parabola, the beam was found to contain 10 12 tritons per pulse, with a mean energy of 2.2 MeV and an exponential tail reaching up to 10 MeV. In a separate experiment, the triton beam was directed onto a secondary deuterated polyethylene (CD) target to induce deuterium–tritium (D–T) nuclear reactions. Using neutron time-of-flight spectrometers, approximately 10 8 D–T fusion neutrons were observed per laser pulse. Furthermore, this triton beam presents new research opportunities for the study of the 3 H(t, 2n) 4 He reaction and di-neutron transfers to lithium and beryllium that may produce exotic neutron-rich nuclei of interest to basic nuclear science, astrophysics, and inertial confinement fusion technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Global Distribution of Shallow Water on Mars: Neutron Mapping of Summer-Time Surface by HEND/Odyssey

Orbital mapping of induced neutrons and gamma-rays by Odyssey has recently successfully proven the applicability of nuclear methods for studying of the elementary composition of Martian upper-most subsurface. In particular, the suite of Gamma-Ray Spectrometer (GRS) has discovered the presence of large water-ice rich regions southward and northward on Mars. The data of neutron mapping of summer-time surface are presented below from the Russian High Energy Neutron Spectrometer (HEND), which is a part of GRS suite. These maps represent the content of water in the soil for summer season at Southern and Northern hemispheres, when the winter deposit of CO2 is absent on the surface. The seasonal evolution of CO2 coverage on Mars is the subject of the complementary paper.

Mitrofanov, I. G.↗

Reconciling the MOLA, TES, and Neutron Observations of the North Polar CO2 Mass Budget on Mars

There are now three independent observations of the CO2 polar cap mass budget of Mars' north polar cap. The first is based elevation changes detected by the Mars Orbiter Laser Altimeter (MOLA) on the Mars Global Surveyor (MGS). The second is based on MGS Thermal Emission Spectrometer (TES) broadband observations of the solar and infrared radiation fields at the top of the atmosphere. The third is based on neutron counts measured by the neutron spectrometer (NS) on Odyssey. If one assumes a cap density of 910 kg/cu m, then the peak mass loading poleward of 85 N inferred from the MOLA data is approx. 1090 kg/sq m, which compares to approx. 1150 kg/sq m inferred from TES for the same region, and 700 kg/sq m from the NS data. TES and MOLA are in good agreement, but are about 60% higher than the NS data. Is there a way to reconcile these discrepancies?

Haberle, Robert M.↗

Reconciling the MOLA, TES, and Neutron Observations of the North Polar CO2 Mass Budget on Mars

There are now three independent observations of the CO2 polar cap mass budget of Mars' north polar cap. The first is based elevation changes detected by the Mars Orbiter Laser Altimeter (MOLA) on the Mars Global Surveyor (MGS). The second is based on MGS Thermal Emission Spectrometer (TES) broadband observations of the solar and infrared radiation fields at the top of the atmosphere. The third is based on neutron counts measured by the neutron spectrometer (NS) on Odyssey. The TES data are based on an energy balance. The net radiative loss (gain) in a column is balanced by latent heating due condensation (sublimation) of CO2. In calculating the mass budget, the other main energy sources, atmospheric heat transport and subsurface conduction, were neglected. At the pole, atmospheric heat transport is indeed a small term. However, subsurface heat conduction can be significant because at the North Pole water ice, which has a high thermal conductivity compared to bare soil, is a dominant component of the subsurface. Thus, heat conducted down into the ice during summer will slowly bleed back out during fall and winter reducing the amount of CO2 that condenses on the pole. We have taken a first cut at quantifying this effect by fitting a curve to Paige's estimates of the conducted energy flux in his analysis of Viking IRTM data.

Haberle, R. M.↗