Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Verification of the sensitivity and uncertainty-based criticality safety validation techniques: ORNL’s SCALE case study

The use of sensitivity and uncertainty-based techniques has been well-developed in the neutronic community for criticality safety applications. Sensitivity techniques calculate the first-order relative variations in keff due to relative cross-section variations by isotope, reaction type, and incident neutron energy. The result is a vector of sensitivity coefficients which is folded with prior cross-section uncertainties to calculate the so-called similarity indices. Similarity indices are integral quantities which serve as useful mathematical measures for assessing the relevance of existing or new experiments to given application conditions, representing design systems for which the models are to be validated. Despite their importance for a wide range of validation activities, the peer-reviewed literature is non-existent on the development of rigorous verification analysis for their calculated values. Thus, this manuscript proposes a simple non-intrusive method to calculate similarity indices, serving as an independent verification tool for their evaluation. The manuscript derives the theoretical basis for the proposed verification analysis. Next, the verification analysis is applied to the ORNL’s SCALE code suite which employs adjoint-based methods to calculate similarity indices. Numerical experiments using a number of well-known benchmark experiments are employed to verify the calculation of the similarity indices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

Machine Learning assisted optimization and parameter space exploration dataset of spin ice Hamiltonian

This repository contains both simulated and experimental structure factor data for the data challenge involving the inverse scattering problem. The simulated data were generated during a machine-learning-assisted optimization routine described in ref[1]. The experimental structure factor was measured on a rare-earth oxide, Dy2Ti2O7 using diffuse neutron scattering from time-of-flight techniques on the CORELLI instrument at the Spallation Neutron Source, Oak Ridge National Laboratory. A Metropolis Monte Carlo code implemented to run in a High-performance computing setting was used to calculated simulated structure factors for the spin-ice Hamiltonian at 680 mK, which is the same temperature as for the experimental data. The total size of all the files in this repository is 5.12 GB. A detailed description of the files is given below. ExperimentalData_630mK.dat – A linearized version of 3-dimensional experimental data of size 61×81×21. This data was processed to remove an estimation of non-magnetic background, including nuclear scattering signal and instrumentation background. Parameters.dat – 6700 samples were evaluated over the 4-dimensional parameter space (J_1, J_2, J_3 and J_(3^' )). There is an additional parameter, D in the spin Hamiltonian to mimic the dipolar interaction between magnetic ions. However, this parameter, D was fixed to a value determined by prior work. This file contains five columns for the parameters J_1, J_2, J_3, J_(3^' ) and D respectively. 3D_Simulation_Data.dat – The simulated structure factor, S(Q) data are included in this file. Each raw contains a linearized array of 3D volumes of S(Q) calculated for the parameter set given in the corresponding row of the file Parameters.dat. The size of the volume data was matched to the experimental data. Qx(h,-h,0).dat, Qy(k,k,-2k).dat, Qz(l,l,l).dat – These files contain the h, k, and l values along with the reciprocal vectors [h,-h,0], [k,k,-2k] and [l,l,l] respectively.

36 MATERIALS SCIENCE↗

Multiple shape coexistence near {sup 118}Sn: First 0+ 3 lifetime measurement

The intruder bands in Sn isotopes, built on the 2p-2h excitation across the Z = 50 proton shell gap, are well-known examples of shape coexistence near the neutron mid-shell region. Spectroscopic signatures for shape coexistence include enhanced E0 transitions between the 0+ band heads. However, the underlying shape coexistence and mixing has been unclear because lifetime information for the excited 0+ states was incomplete in 118Sn. We thus present here the first measurement of the 0+ 3 lifetime in 118Sn using the fast-timing technique following thermal-neutron capture. The observed enhancement in ρ2(E0;0+ 3 → 0+ 2 ) of 150(30) milliunits provides compelling indications for multiple shape coexistence in 118Sn. Additionally, three distinct shapes in 116,118,120Sn naturally emerged in theoretical calculations based on the quantum-number-projected generator coordinate method employing a relativistic energy density functional.

Wu, F.↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beta-Delayed Neutron Emission of 𝑁=84 132Cd

Using the time-of-flight technique, we measured the beta-delayed neutron emission of 132 Cd . From our large-scale shell model (LSSM) calculation using the N3⁢LO interaction [, Phys. Rev. Lett. 131, 022501 (2023)], we suggest the decay is dominated by the transformation of a neutron in the 𝑔7/2 orbital, deep below the Fermi surface, into a proton in the 𝑔9/2 orbital. We compare the beta-decay half-lives and neutron branching ratios of nuclei with 𝑍<50 and 𝑁 ≥82 obtained with our LSSM with those of leading “global” models such as finite-range droplet model (FRDM). Our calculations match known half-lives and neutron branching ratios well and suggest that current leading models overestimate the yet-to-be-measured half-lives. Our model, backed by the 132 Cd decay data presented here, offers robust predictive power for nuclei of astrophysical interest such as 𝑟-process waiting points.

Madurga, M [Department of Physics and Astronomy, U↗

Novel Measurement of the Neutron Magnetic Form Factor from A=3 Mirror Nuclei

The electromagnetic form factors of the proton and neutron encode information on the spatial structure of their charge and magnetization distributions. While measurements of the proton are relatively straightforward, the lack of a free neutron target makes measurements of the neutron's electromagnetic structure more challenging and more sensitive to experimental or model-dependent uncertainties. Various experiments have attempted to extract the neutron form factors from scattering from the neutron in deuterium, with different techniques providing different, and sometimes large, systematic uncertainties. We present results from a novel measurement of the neutron magnetic form factor using quasielastic scattering from the mirror nuclei 3 H and 3 He, where the nuclear effects are larger than for deuterium but expected to largely cancel in the cross-section ratios. We extracted values of the neutron magnetic form factor for low-to-modest momentum transfer, 0.6 < Q 2 < 2.9 GeV 2 , where existing measurements give inconsistent results. The precision and Q 2 range of these data allow for a better understanding of the current world’s data and suggest a path toward further improvement of our overall understanding of the neutron’s magnetic form factor.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods for neutron diffraction studies on hydride superconductors and other metal hydrides

High-pressure neutron diffraction is an extremely useful technique in the quest for making and understanding novel hydride superconductors. Neutron diffraction can be used to directly determine elemental stoichiometries and atomic positions of many light elements such as hydrogen or deuterium, even in the presence of heavy elements such as rare-earth metals. In this work, we report on the current status and ongoing developments on high-pressure neutron diffraction for hydride superconductors and other metal hydrides with a special focus on current advancements at the Spallation Neutrons and Pressure (SNAP) beamline of the Spallation Neutron Source at Oak Ridge National Laboratory. For broader context, an overview of high-pressure neutron diffractometers and pressure cells is included together with insight into critical sample considerations. There, attention is given to the requirements for powdered hydride samples and the need for deuterium rather than hydrogen. Additionally, the advantages of angular access and data representation as possible at SNAP are described. We demonstrate the current capability for high-pressure neutron diffraction on two different samples created via hydrogen gas loading, specifically pure deuterium and nickel-deuteride. The deuterium example highlights the usefulness of adding sample materials that facilitate the formation of a good powder while the nickel-deuteride example demonstrates that atomic deuterium positions and stoichiometry can be directly determined. Both examples highlight the importance of large scattering apertures. These enable investigation of the data resolved by scattering angle that is needed to identify parasitic peaks and background features. Finally, future directions beyond current high-pressure neutron powder diffraction are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of Gaussian Bayes classifier to differentiate chlorine-based chemical agents

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector. One of the difficult technical challenges is to discriminate the chlorine-based chemical agents. Especially, CN, CNB, CNS and CG have similar chemical compositions to make it hard to discriminate them with a higher confidence. Current identification algorithms for PINS systems with 252-Cf sources have been improved and updated continuously as more field data became available, and new algorithms was studied to complement the current algorithms by adopting the Gaussian Bayes classifier. These new algorithms were intended to be applied to a subset of chlorine-based chemical agents, and their main goal is discriminate CN, CNB, CNS and CG with their ratios of the chlorine neutron inelastic 1763keV peak to the chlorine thermal neutron capture 1959keV peak, which is referred to as the “Cl i/c” or “clic” ratio in this study. The Cl i/c ratios were assumed to follow Gaussian distributions with the means and the standard deviations unique to their corresponding chemical agents. The prior probabilities of these four chemical agents were optimized with a collection of field data to achieve the best performance in terms of precision or positive predictive value (PPV). Finally, their posterior probabilities as functions of the Cl i/c ratio were implemented in the current version of PINS analysis software in order to be tested with more field data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spin-textured neutron beams with orbital angular momentum

In this work, we present a rigorous theoretical framework underpinning the technique of spin-echo modulated small-angle neutron scattering (SEMSANS), and show how the technique can be extended in order to generate spin-textured neutron beams with orbital angular momentum (OAM) via birefringent neutron spin-polarization devices known as magnetic Wollaston prisms. Neutron OAM beams are mathematically characterized by a “cork-screw” phase singularity e iℓΦ about the propagation axis where ℓ is the OAM quantum number. To understand the precise relationship between the emergent OAM state and the variety of spin textures realized by various setups, we have developed a path-integral approach that in the interferometric limit makes a judicious use of magnetic Snell's law. We show that our proposed technique produces a complex two-dimensional pattern of spin-OAM entangled states which may be useful as a probe of quantum magnetic materials. We compare our path-integral approach to the well-known single-path Larmor precession model and present a pedagogical derivation of magnetic Snell's law of refraction for both massive and massless particles based on Maupertuis's action principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗