Search NASA⌕ Search

SEARCH · Search NASA

Results for “nonvolatile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Polar deposits of Mars

Layered deposits unique to the poles of Mars indicate long-term winter deposition of ice and sediment modulated by periodic climate change. The layered deposits contain at least two kinds of nonvolatile materials: one that is similar to the bright red dust raised in Martian dust storms, and one similar to dark sand dune materials observed at low and mild latitudes. The ice fraction of the deposits remains unknown. Because the present polar dust and ice budgets are poorly constrained, correlation of layer thicknesses with specific astronomical cycles remains very uncertain. Layered deposits in both polar regions appear to have been slightly more widespread in the past. Other sediments near the poles, and the estimated ages of the layered deposits, suggest that the polar sedimentary regime has evolved over the geologic history of Mars. Acquisition of good data on the vertical sequence of layer characteristics and better crater retention ages should allow revealing comparisons with astronomically driven cycles and secular atmospheric changes.

Thomas, P.↗

A high sensitivity real-time NVR monitor

The use of a temperature-controlled 200-MHz SAW resonator piezoelectric mass microbalance to monitor the mass of nonvolatile residue (NVR) deposited on its surface in real time is reported. The fundamental frequency of this device is mainly dependent on the configuration of the transducers and not on the thickness of the substrate. Therefore, higher operating frequencies can be achieved without reducing the thickness of the crystal. The real-time instrument was integrated onto a conventional stainless steel NVR plate and operated flawlessly over a 14-d period at Kennedy Space Center and successfully measured less than 1 ng/sq cm d NVR contamination. Contamination episodes detected by the instrument were correlated with scheduled activities on the test stand. Under the assumption of a baseline noise level of +/- 2 Hz, the absolute mass lower limit of detection would be 0.065 ng/sq cm. This would enable the detection of a daily NVR deposition rate of less than 0.1 ng/sq cm d.

Bowers, William D.↗

Performance of redundant disk array organizations in transaction processing environments

A performance evaluation is conducted for two redundant disk-array organizations in a transaction-processing environment, relative to the performance of both mirrored disk organizations and organizations using neither striping nor redundancy. The proposed parity-striping alternative to striping with rotated parity is shown to furnish rapid recovery from failure at the same low storage cost without interleaving the data over multiple disks. Both noncached systems and systems using a nonvolatile cache as the controller are considered.

Mourad, Antoine N.↗

Thermal decomposition of ethylpentaborane in gas phase

The thermal decomposition of ethylpentaborane at temperatures of 185 degrees to 244 degrees C is approximately a 1.5-order reaction. The products of the decomposition were hydrogen, methane, a nonvolatile boron hydride, and traces of decaborane. Measurements of the rate of decomposition of pentaborane showed that ethylpentaborane has a greater rate of decomposition than pentaborane.

Mcdonald, Glen E↗

Optically Addressable, Ferroelectric Memory With NDRO

For readout, memory cells addressed via on-chip semiconductor lasers. Proposed thin-film ferroelectric memory device features nonvolatile storage, optically addressable, nondestructive readout (NDRO) with fast access, and low vulnerability to damage by ionizing radiation. Polarization switched during recording and erasure, but not during readout. As result, readout would not destroy contents of memory, and operating life in specific "read-intensive" applications increased up to estimated 10 to the 16th power cycles.

Thakoor, Sarita↗

Three-Dimensional Vertical-Bloch-Line Memory System

In proposed magnetic memory system without moving parts, data is stored in stack of two-dimensional vertical-Bloch-line (VBL) memory chips or modules. System similar to one described in "Three-Dimensional Magnetic-Bubble Memory System" (NPO-18533). Each VBL module in this memory system silimar to module described in "Vertical-Bloch-Line Memory" (NPO-18467). Advantages include high storage density, high speed, nonvolatility, and insensitivity to ionizing radiation.

Katti, Romney R.↗

Using Water To Analyze Greasy Residues

Water found useful as substitute for chlorofluorocarbon (CFC) solvents in tests to measure amounts of nonvolatile residues of contaminants (e.g., hydrocarbon greases) on equipment after it has been cleaned. Water does not harm environment and much cheaper than CFCs.

Hoppesch, Charles W.↗

Improved Ferroelectric Memories With Nondestructive Readout

Ferroelectric memories with enhanced photoresponse leading to improved nondestructive optoelectronic readout and lower power demand proposed. Memories improved versions of devices described in "Rapid, Nondestructive Readout From Ferroelectric Memory" (NPO-18551). In proposed application, array of nonvolatile ferroelectric memory cells fabricated by standard very-large-scale integrated-circuit techniques and flip-bonded onto similarly fabricated array of semiconductor lasers, {see "Optically Addressable, Ferroelectric Memory With NDRO" (NPO-18573)}.

Thakoor, Sarita↗

Reconfigurable fuzzy cell

This invention relates to a reconfigurable fuzzy cell comprising a digital control programmable gain operation amplifier, an analog-to-digital converter, an electrically erasable PROM, and 8-bit counter and comparator, and supporting logic configured to achieve in real-time fuzzy systems high throughput, grade-of-membership or membership-value conversion of multi-input sensor data. The invention provides a flexible multiplexing-capable configuration, implemented entirely in hardware, for effectuating S-, Z-, and PI-membership functions or combinations thereof, based upon fuzzy logic level-set theory. A membership value table storing 'knowledge data' for each of S-, Z-, and PI-functions is contained within a nonvolatile memory for storing bits of membership and parametric information in a plurality of address spaces. Based upon parametric and control signals, analog sensor data is digitized and converted into grade-of-membership data. In situ learn and recognition modes of operation are also provided.

Salazar, George A.↗

Polar sediment accumulation: Role of surface winds at the two poles

The accumulation of the large deposits of volatile and nonvolatile sediments at both Martian poles has occurred through periods of likely climate change. Most data on wind directions near the Martian poles and seasonal activity relate to a very short period of time, at one point in climate cycles. It is still uncertain what the net budgets to the poles are and how this budget (if known) would fit into longer climate/sediment cycles. Pending further data we examined the full suite of Viking high-resolution, high-latitude images for wind markers of all sizes and types. These probably represent timescales of formation from days to several tens of thousands of years. The goal is to estimate the effectiveness, and possible drivers, of wind systems that bring materials near the surface to the regions of polar sediments and that also remove materials from the polar areas.

Thomas, P. C.↗

Variations among chondrite groups: Constraints on nebular processes

Diverse proportions of the four major ingredients are found in the 13 chondrite groups. Ca-Al-rich inclusions (CAI) include amoeboid-olivine aggregates, which contain refractory nodules. Matrix material forms aggregates and rims on other constituents and contains micrometer-sized grains and a small, uniform concentration of presolar grains. Fe, Ni grains are mostly derived from hot chondrules. Although bulk nonvolatile chondritic elemental ratios are typically within 30% of solar values, individual CAI and some chondrules shown large deviations.

Scott, E. R. D.↗

SSME Main Combustion Chamber (MCC) hot oil dewaxing

In an attempt to comply with the changing environmental regulations, a process was developed for the replacement of perchloroethylene in the dewaxing of the Space Shuttle Main Engine (SSME) Main Combustion Chamber (MCC) and other associated hardware filled with the Rigidax (R) casting compound. Rigidax (R) is a hard blue-dyed, calcium carbonate filled thermoplastic casting compound (melting point 77 C) that is melted and poured into hardware cavities to prevent contamination during material removal processes, i.e. machining, grinding, drilling, and deburring. Additionally, it serves as a maskant for designated areas during electroforming processes. Laboratory testing was conducted to evaluate seven alternate fluids for the replacement of perchloroethylene in the dewaxing process. Based upon successful laboratory results, a mineral oil was selected for testing on actual hardware. The final process developed involves simultaneous immersion and flushing of the MCC channels using a distinct eight stage process. A nonvolatile hydrocarbon analysis of a solvent flush sample is performed to determine the hardware cleanliness for comparison to the previous perchloroethylene dewaxing process.

Akpati, Anthony U.↗

Aqueous cleaning and verification processes for precision cleaning of small parts

The NASA Kennedy Space Center (KSC) Materials Science Laboratory (MSL) has developed a totally aqueous process for precision cleaning and verification of small components. In 1990 the Precision Cleaning Facility at KSC used approximately 228,000 kg (500,000 lbs) of chlorofluorocarbon (CFC) 113 in the cleaning operations. It is estimated that current CFC 113 usage has been reduced by 75 percent and it is projected that a 90 percent reduction will be achieved by the end of calendar year 1994. The cleaning process developed utilizes aqueous degreasers, aqueous surfactants, and ultrasonics in the cleaning operation and an aqueous surfactant, ultrasonics, and Total Organic Carbon Analyzer (TOCA) in the nonvolatile residue (NVR) and particulate analysis for verification of cleanliness. The cleaning and verification process is presented in its entirety, with comparison to the CFC 113 cleaning and verification process, including economic and labor costs/savings.

Allen, Gale J.↗

Replacement of ozone depleting and toxic chemicals in gravimetric analysis of non-volatile residue

The standard tests for determining nonvolatile residue accretion on spacecraft surfaces and in clean processing facilities rely on the use of halogenated solvents that are targeted for elimination because of their toxic or ozone-depleting natures. This paper presents a literature-based screening survey for candidate replacement solvents. Potential replacements were evaluated for their vapor pressure, toxicity, and solvent properties. Three likely candidates were identified: ethyl acetate, methyl acetate, and acetone. Laboratory tests are presented that evaluate the suitability of these candidate replacement solvents.

Arnold, G. S.↗

Cleaning verification by air/water impingement

This paper will discuss how the Kennedy Space Center intends to perform precision cleaning verification by Air/Water Impingement in lieu of chlorofluorocarbon-113 gravimetric nonvolatile residue analysis (NVR). Test results will be given that demonstrate the effectiveness of the Air/Water system. A brief discussion of the Total Carbon method via the use of a high temperature combustion analyzer will also be given. The necessary equipment for impingement will be shown along with other possible applications of this technology.

Jones, Lisa L.↗

Measurements of cloud condensation nuclei spectra within maritime cumulus cloud droplets: Implications for mixing processes

In a cloud formed during adiabatic expansion, the droplet size distribution will be systematically related to the critical supersaturation of the cloud condensation nuclei (CNN), but this relationship can be complicated in entraining clouds. Useful information about cloud processes, such as mixing, can be obtained from direct measurements of the CNN involved in droplet nucleation. This was accomplished by interfacing two instruments for a series of flights in maritime cumulus clouds. One instrument, the counterflow virtual impactor, collected cloud droplets, and the nonvolatile residual nuclei of the droplets was then passed to a CCN spectrometer, which measured the critical supersaturation (S(sub c)) spectrum of the droplet nuclei. The measured S(sub c) spectra of the droplet nuclei were compared with the S(sub c) spectra of ambient aerosol particles in order to identify which CCN were actually incorporated into droplets and to determine when mixing processes were active at different cloud levels. The droplet nuclei nearly always exhibited lower median S(sub c)'s than the ambient aerosol, as expected since droplets nucleate perferentially on particles with lower critical supersaturations. Critical supersaturation spectra from nuclei of droplets near cloud base were similar to those predicted for cloud regions formed adiabatically, but spectra of droplet nuclei from middle cloud levels showed some evidence that mixing had occurred. Near cloud top, the greatest variation in the spectra of the droplet nuclei was observed, and nuclei with high S(sub c)'s were sometimes present even within relatively large droplets. This suggests that the extent of mixing increases with height in cumulus clouds and that inhomogeneous mixing may be important near cloud top. These promising initial results suggest improvements to the experimental technique that will permit more quantitative results in future experiments.

Twohy, Cynthia H.↗

Instruments Sniff Organic Surface Contaminants

Portable instruments detecting both nonvolatile and volatile organic surface contaminants in real time developed. Instruments easy to use: operate under ordinary ambient atmospheric conditions, without need to use messy liquid solvents or install and remove witness plates, and without need to cut specimens from surfaces to be inspected. Principle of detection involves sweeping pure, activated gas across surface spot inspected, then monitoring light emitted at wavelengths characteristic of excited molecules formed by chemical reactions between activated gas and contaminants. Gas activated by dc discharge, radio-frequency induction, microwave radiation, laser beam, hot filaments, or any other suitable means that excites some of gas molecules.

Adler-Golden, Steven↗

Maximum Acceleration Recording Circuit

Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

Bozeman, Richard J., Jr.↗