Search NASA⌕ Search

SEARCH · Search NASA

Results for “novel light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Measuring Black Hole Light Echoes with Very Long Baseline Interferometry

Light passing near a black hole can follow multiple paths from an emission source to an observer due to strong gravitational lensing. Photons following different paths take different amounts of time to reach the observer, which produces an echo signature in the image. The characteristic echo delay is determined primarily by the mass of the black hole, but it is also influenced by the black hole spin and inclination to the observer. In the Kerr geometry, echo images are demagnified, rotated, and sheared copies of the direct image and lie within a restricted region of the image. Echo images have exponentially suppressed flux, and temporal correlations within the flow make it challenging to directly detect light echoes from the total light curve. In this Letter, we propose a novel method to search for light echoes by correlating the total light curve with the interferometric signal at high spatial frequencies, which is a proxy for indirect emission. We explore the viability of our method using numerical general relativistic magnetohydrodynamic simulations of a near-face-on accretion system scaled to M87-like parameters. We demonstrate that our method can be used to directly infer the echo delay period in simulated data. An echo detection would be clear evidence that we have captured photons that have circled the black hole, and a high-fidelity echo measurement would provide an independent measure of fundamental black hole parameters. Our results suggest that detecting echoes may be achievable through interferometric observations with a modest space-based very long baseline interferometry mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron resolved microscale mineralogy and elemental composition of individual plinthic and manganiferous nodules from agricultural soils

Iron and manganese oxides are strong sorbents and elemental scavengers in the environment that can form macroscopic nodules in soils. Despite their importance in the geochemical cycling of nutrients and contaminants, nodules are rarely characterized. When analyzed, they are often combined into bulk samples, obscuring individual characteristics. This study investigates the composition and mineralogy of individual plinthic and manganiferous nodules in soil from cropping systems in the Farming Systems Project in Beltsville, Maryland. Elemental composition indicates the accumulation of contaminants and nutrients, including copper in all nodules and high levels of phosphorus in select nodules. Sequential extractions determine that highly crystalline minerals comprise the nodules, locking away these nutrients and contaminants. Bulk X-ray diffraction (XRD) demonstrated distinct mineralogies in the plinthic and manganiferous nodules, with the former comprised of quartz, goethite, and kaolinite, and the latter consisting of quartz, Mn 2 O 3 , and hematite. Synchrotron and laboratory-based X-ray fluorescence (XRF) mapping gives critical insight into the elemental distribution within the nodules and elucidates spatial elemental associations, including the coupling of manganese and iron in the manganiferous nodules. XRF maps paired with µXRD provide microscale spatial resolution in mineralogy, which resolved several phases not apparent in bulk XRD, manganese’s association with goethite, and minerals indicative of redox transformations, including magnetite and maghemite. These novel results provide critical insight into the microscale mineralogy and individual elemental composition of plinthic and manganiferous nodules, as well as how they alter bulk soil geochemistry in ways largely unaccounted for in research on soil systems.

36 MATERIALS SCIENCE↗

High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence

A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.

Eldridge, Jeffrey↗

Plastic shrinkage of mortars cured with a paraffin-based compound – Bimodal neutron/X-ray tomography study

Early-age drying (immediately after casting) of mortars and the corresponding plastic shrinkage were studied using bimodal neutron/X-ray computed tomography. This novel, correlative 3D imaging mode enabled studying simultaneously and without any source of spurious perturbation the water migration and loss processes together with the corresponding deformations due to plastic shrinkage. Bimodal imaging opens up new possibilities for studying dynamic processes of coupled water transport and deformations in porous solids. The measurements were carried out on model systems (cylindrical mortar specimens with height of 19 mm). The study focused on the effect of a paraffin-based curing compound. Our results confirm that when the curing compound was applied directly onto the drying surface in a sufficient amount, both the evaporation rate and the rate of vertical displacement (settlement) were substantially reduced. The results shed a new light on the mechanisms of plastic shrinkage and the action of curing compounds.

36 MATERIALS SCIENCE↗

Deep Generative Modeling of Periodic Variable Stars Using Physical Parameters

The ability to generate physically plausible ensembles of variable sources is critical to the optimization of time domain survey cadences and the training of classification models on data sets with few to no labels. Traditional data augmentation techniques expand training sets by reenvisioning observed exemplars, seeking to simulate observations of specific training sources under different (exogenous) conditions. Unlike fully theory-driven models, these approaches do not typically allow principled interpolation nor extrapolation. Moreover, the principal drawback of theory-driven models lies in the prohibitive computational cost of simulating source observables from ab initio parameters. In this work, we propose a computationally tractable machine learning approach to generate realistic light curves of periodic variables capable of integrating physical parameters and variability classes as inputs. Our deep generative model, inspired by the transparent latent space generative adversarial networks, uses a variational autoencoder (VAE) architecture with temporal convolutional network layers, trained using the OGLE-III optical light curves and physical characteristics (e.g., effective temperature and absolute magnitude) from Gaia DR2. A test using the temperature–shape relationship of RR Lyrae demonstrates the efficacy of our generative “physics-enhanced latent space VAE” (PELS-VAE) model. Such deep generative models, serving as nonlinear nonparametric emulators, present a novel tool for astronomers to create synthetic time series over arbitrary cadences.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Measurement of B(sub 22) of Macromolecules in a Flow Cell

An improved apparatus has been invented for use in determining the osmotic second virial coefficient of macromolecules in solution. In a typical intended application, the macromolecules would be, more specifically, protein molecules, and the protein solution would be pumped through a flow cell to investigate the physical and chemical conditions that affect crystallization of the protein in question. Some background information is prerequisite to a meaningful description of the novel aspects of this apparatus. A method of determining B22 from simultaneous measurements of the static transmittance (taken as an indication of concentration) and static scattering of light from the same location in a flowing protein solution was published in 2004. The apparatus used to implement the method at that time included a dual-detector flow cell, which had two drawbacks: a) The amount of protein required for analysis of each solution condition was of the order of a milligram - far too large a quantity for a high-throughput analysis system, for which microgram or even nanogram quantities of protein per analysis are desirable. b) The design of flow cell was such that two light sources were used to probe different regions of the flowing solution. Consequently, the apparatus did not afford simultaneous measurements at the same location in the solution and, hence, did not guarantee an accurate determination of B22.

Wilson, Wilbur↗

Intense infrared lasers for strong-field science

The advent of chirped-pulse amplification in the 1980s and femtosecond Ti:sapphire lasers in the 1990s enabled transformative advances in intense laser–matter interaction physics. Whereas most of experiments have been conducted in the limited near-infrared range of 0.8–1 μm, theories predict that many physical phenomena such as high harmonic generation in gases favor long laser wavelengths in terms of extending the high-energy cutoff. Significant progress has been made in developing few-cycle, carrier-envelope phase-stabilized, high-peak-power lasers in the 1.6–2 μm range that has laid the foundation for attosecond X ray sources in the water window. Even longer wavelength lasers are becoming available that are suitable to study light filamentation, high harmonic generation, and laser–plasma interaction in the relativistic regime. Long-wavelength lasers are suitable for sub-bandgap strong-field excitation of a wide range of solid materials, including semiconductors. In the strong-field limit, bulk crystals also produce high-order harmonics. In this review, we first introduce several important wavelength scaling laws in strong-field physics, then describe recent breakthroughs in short- (1.4–3 μm), mid- (3–8 μm), and long-wave (8–15 μm) infrared laser technology, and finally provide examples of strong-field applications of these novel lasers. Furthermore, some of the broadband ultrafast infrared lasers will have profound effects on medicine, environmental protection, and national defense, because their wavelengths cover the water absorption band, the molecular fingerprint region, as well as the atmospheric infrared transparent window.

43 PARTICLE ACCELERATORS↗

Observations of snow and ice features during the polar winter using moonlight as a source of illumination

Sunlight reflected off the surface of the moon provides sufficient illumination for nighttime imaging of the earth from those spacecraft on which the instruments are sensitive to low light levels. The Defense Meteorological Satellite Program (DMSP) series of satellites are at present the only systems capable of furnishing visible nocturnal images of the earth from space. Features having a high albedo in the visible wavelengths, such as snow and ice, can easily be identified on moonlit nights when the moon is in the gibbous or full phases. Little information exists about the distribution of leads, fractures, and polynya on a basin-wide scale in the winter pack ice, and knowledge of oceanic and atmospheric fluxes is hindered by the limited data available in winter. The DMSP data is a relatively untapped source for observing polar regions during the winter. Using nighttime imagery is a novel way to explore polar areas during the winter months when the sun is below the horizon for much of the time.

Foster, James L.↗

High-Speed Operation of Interband Cascade Lasers

Optical sources operating in the atmospheric window of 3-5 microns are of particular interest for the development of free-space optical communication link. It is more advantageous to operate the free-space optical communication link in 3-5-microns atmospheric transmission window than at the telecom wavelength of 1.5 m due to lower optical scattering, scintillation, and background radiation. However, the realization of optical communications at the longer wavelength has encountered significant difficulties due to lack of adequate optical sources and detectors operating in the desirable wavelength regions. Interband Cascade (IC) lasers are novel semiconductor lasers that have a great potential for the realization of high-power, room-temperature optical sources in the 3-5-microns wavelength region, yet no experimental work, until this one, was done on high-speed direct modulation of IC lasers. Here, highspeed interband cascade laser, operating at wavelength 3.0 m, has been developed and the first direct measurement of the laser modulation bandwidth has been performed using a unique, highspeed quantum well infrared photodetector (QWIP). The developed laser has modulation bandwidth exceeding 3 GHz. This constitutes a significant increase of the IC laser modulation bandwidth over currently existing devices. This result has demonstrated suitability of IC lasers as a mid-IR light source for multi-GHz free-space optical communications links

Soibel, Alexander↗

Novel Microgreen Crop Testing for Space

Long-duration missions beyond low-Earth orbit will encounter challenges in maintaining adequate nutrition and crew acceptability in the food system. In situ production of fresh produce can supplement nutrient deficiencies in the prepackaged diet. Currently, there are a relatively small number of crops that can be reliably grown in space for space crop production efforts. An intriguing area of new investigation involves novel types of microgreens that have the potential to be sources of calories, fat, carbohydrates, and protein. These sources of nutrition are not obtainable in significant quantities with current pick and eat crops. Many microgreen cultivars are also sources of nutrients of interest, such as Vitamins B1, C, and K, and elements such as potassium. Microgreens should be selected to address specific nutritional deficits, as identified by NASA’s Human Research Program, with an emphasis on having a diversity of crops to meet nutritional requirements and crew acceptability. To achieve this, the concept of Crop Readiness Level (CRL) has been developed to gauge readiness of crops for spaceflight applications. CRL includes assessing environmental compatibility, food safety considerations, relevant nutritional analysis, and sensory analysis. Recent testing at Kennedy Space Center has focused on advancing the CRL of a variety of novel microgreens. These varieties were grown under 150 µmol m -2 s -1 PPFD from LED lights, 3000 ppm CO 2 , and 23°C to simulate an ISS environment. Crops were harvested and yield was assessed. Then, baseline microbiological and nutritional analysis (Vitamins B1, C, K; mineral analysis; proximate analysis) and sensory evaluation were performed. These baseline data are essential to selecting candidate crops for future missions and assessing crop production hardware and changes in environmental conditions on future crop performance and nutritional quality.

nutrition↗

Generation and control of phase-locked Bessel beams with a persistent noninterfering region

We present, to the best of our knowledge, a novel method for the generation of multiple Bessel-like (Bessel–Gauss) beams with tilted wavefronts whose optical phases can be controlled independently. In the far field multiple field-free regions develop that are persistent to interference effects and the optical phase. The extent of these field-free regions can be controlled through the tilt angle of the wavefront with a theoretical maximum resolution of 0.1 mrad. Experimentally we employ a spatial light modulator, a lens, and an axicon, each suitable for narrow-band (continuous-wave) and broadband operation. Because of the simplicity in the optical elements, the number of noninterfering Bessel-like beams can be scaled on demand for applications that require multiple sources for coherent imaging or multiple intense beams over a controllable region with the added benefit of a field-free region for detection. Here, for reasons of clarity, we characterized two beams.

Rodnova, Zhanna↗

New Dimensions in the Theory of Excited States and X-ray Spectra (Final Report)

This Final Technical Report briefly summarizes the achievements during the lifetime of our DOE BES grant DE-FG02-97ER45623. The long-term goal of this project has been the development of quantitative theories of the interaction between radiation and matter, with a focus on x-ray spectroscopies. X-ray spectra have long been among the most important probes of atomic-scale structure and properties of matter, ranging from atoms and molecular systems to condensed matter and exotic states. These spectroscopies are widely used in investigations at the major DOE synchrotron x-ray facilities and related centers world-wide. In addition to fundamental theory, a major goal of our project has been the development of computational software that implements the theory for calculations of x-ray spectra of various materials throughout the periodic table. Due to the complex nature of x-ray spectra, quantitative theory is essential for its interpretation. The theory is challenging since it involves excited state electronic structure and many-body correlation effects that go beyond independent particle approximations like DFT or Hartree-Fock. Moreover, the experimental investigations typically involve a broad range of energy, time, and temperature scales, from the UV-Vis to hard x-ray energies of order 10 4 eV, and temperatures T from ambient up to the warm-dense-matter regime where the Fermi energy kBTF is of order a few eV, i.e., temperatures of order 105 Kelvin. This broad range of experimental conditions has fostered many novel theoretical approaches and computational techniques, many of which we have developed systematically over the duration of the grant. In contrast to the traditional wave-function approach of quantum theory and electronic structure methods, our theoretical approach is based on modern Green's function techniques. This approach is better suited for aperiodic structures, excited states, and broad spectral ranges, since it avoids the computational bottlenecks of sum-over-states approaches, as in the Fermi golden rule. This theoretical framework has been incorporated into efficient, user-friendly x-ray spectroscopy software which is now used routinely worldwide to simulate and analyze spectra. These theoretical tools provide an essential complement to synchrotron and next-generation light sources, which are used to investigate complex materials with ever increasing precision. Moreover, the synergism between theory, computation and experiment contributed by our research enhances scientific understanding and creates opportunities for innovations in materials and energy science and in many fields. As documented in this Report, this research grant has been remarkably successful in achieving these goals. In particular, this grant has supported the development of the x-ray spectroscopy software suite known as FEFF (named for an effective scattering amplitude f eff in the theory). The FEFF codes have become one of the premier tools for quantitative simulations of x-ray spectra as documented by many thousands of citations in the Web of Science and Google-Scholar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Nonintrusive Method to Resolve the Thermal Dome Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile s output voltage; therefore, only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer s thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a few percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and nonlinearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol s direct radiative effect using field measurements with and without considering the pyranometer s thermal effect. The results of radiative transfer model simulation show that a pyranometer s thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji. Q.↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, April 2011

Topics covered include: Amperometric Solid Electrolyte Oxygen Microsensors with Easy Batch Fabrication; Two-Axis Direct Fluid Shear Stress Sensor for Aerodynamic Applications; Target Assembly to Check Boresight Alignment of Active Sensors; Virtual Sensor Test Instrumentation; Evaluation of the Reflection Coefficient of Microstrip Elements for Reflectarray Antennas; Miniaturized Ka-Band Dual-Channel Radar; Continuous-Integration Laser Energy Lidar Monitor; Miniaturized Airborne Imaging Central Server System; Radiation-Tolerant, SpaceWire-Compatible Switching Fabric; Small Microprocessor for ASIC or FPGA Implementation; Source-Coupled, N-Channel, JFET-Based Digital Logic Gate Structure Using Resistive Level Shifters; High-Voltage-Input Level Translator Using Standard CMOS; Monitoring Digital Closed-Loop Feedback Systems; MASCOT - MATLAB Stability and Control Toolbox; MIRO Continuum Calibration for Asteroid Mode; GOATS Image Projection Component; Coded Modulation in C and MATLAB; Low-Dead-Volume Inlet for Vacuum Chamber; Thermal Control Method for High-Current Wire Bundles by Injecting a Thermally Conductive Filler; Method for Selective Cleaning of Mold Release from Composite Honeycomb Surfaces; Infrared-Bolometer Arrays with Reflective Backshorts; Commercialization of LARC (trade mark) -SI Polyimide Technology; Novel Low-Density Ablators Containing Hyperbranched Poly(azomethine)s; Carbon Nanotubes on Titanium Substrates for Stray Light Suppression; Monolithic, High-Speed Fiber-Optic Switching Array for Lidar; Grid-Tied Photovoltaic Power System; Spectroelectrochemical Instrument Measures TOC; A Miniaturized Video System for Monitoring Drosophila Behavior; Hydrofocusing Bioreactor Produces Anti-Cancer Alkaloids; Creep Measurement Video Extensometer; Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker n-B-pi-p Superlattice Infrared Detector; Safe Onboard Guidance and Control Under Probabilistic Uncertainty; General Tool for Evaluating High-Contrast Coronagraphic Telescope Performance Error Budgets; Hidden Statistics of Schroedinger Equation; Optimal Padding for the Two-Dimensional Fast Fourier Transform; Spatial Query for Planetary Data; Higher Order Mode Coupling in Feed Waveguide of a Planar Slot Array Antenna; Evolutionary Computational Methods for Identifying Emergent Behavior in Autonomous Systems; Sampling Theorem in Terms of the Bandwidth and Sampling Interval; Meteoroid/Orbital Debris Shield Engineering Development Practice and Procedure; Self-Balancing, Optical-Center-Pivot, Fast-Steering Mirror; Wireless Orbiter Hang-Angle Inclinometer System; and Internal Electrostatic Discharge Monitor - IESDM.

Source record↗

Solid-State Power Generating Microdevices for Distributed Space System Architectures

Deep space missions have a strong need for compact, high power density, reliable and long life electrical power generation and storage under extreme temperature conditions. Conventional power generating devices become inefficient at very low temperatures (temperatures lower than 200 K encountered during Mars missions for example) and rechargeable energy storage devices cannot be operated thereby limiting mission duration. At elevated temperatures (for example for planned solar probe or Venus lander missions), thin film interdiffusion destroys electronic devices used for generating and storing power. Solar power generation strongly depends upon the light intensity, which falls rapidly in deep interplanetary missions (beyond 5 AU), and in planetary missions in the sun shadow or in dusty environments (Mars, for example). Radioisotope thermoelectric generators (RTGs) have been successfully used for a number of deep space missions RTGs. However, their energy conversion efficiency and specific power characteristics are quite low, and this technology has been limited to relatively large systems (more than 100 W). The National Aeronautics and Space Administration (NASA) and the Jet Propulsion Laboratory (JPL) have been planning the use of much smaller spacecrafts that will incorporate a variety of microdevices and miniature vehicles such as microdetectors, microsensors, and microrovers. Except for electrochemical batteries and solar cells, there are currently no available miniaturized power sources. Novel technologies that will function reliably over a long duration mission (ten years and over), in harsh environments (temperature, pressure, and atmosphere) must be developed to enable the success of future space missions. It is also expected that such micropower sources could have a wide range of terrestrial applications, in particular when the limited lifetime and environmental limitations of batteries are key factors. Additional information is contained in the original extended abstract.

Fleurial, J.-P.↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

A Novel Non-Intrusive Method to Resolve the Thermal-Dome-Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile's output voltage; therefore only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer's thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a-few-percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST-traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and non-linearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol's direct-radiative effect using field measurements with and without considering the pyranometer's thermal effect. The results of radiative transfer model simulation show that a pyranometer's thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji, Qiang↗