Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

New Measurements on the Neutrino Mass: KATRIN and Project 8 (Final Technical Report for DE-SC0014130)

The overarching goal of the funded research is to build experiments and develop techniques towards the major goal of measuring the mass of the neutrino, particularly by the method of high-resolution spectroscopy of the endpoint of tritium. The goals of this project were to make hardware and intellectual contributions towards the KATRIN experiment, an international project under construction in Germany, and towards the "Project 8" R&D program to develop new electron spectroscopy methods and apply them to tritium. A minor goal of the project was to support simulation work and R&D on future neutrino and dark matter detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving Fission Products at CARIBU: Near Field Detection (Q1/FY21 Quarterly Progress Report)

After receiving funds at the beginning of FY21 we were able to resume work on the project. We continued data analysis of 156 Eu decay. The project has also gone through an Independent Review in November. Following the previously reported steps in the analysis of 156 Eu, specifically removing random coincidences from the gamma ray spectrum, we look not only at the peak of interest (811 keV) but all other gamma rays that are visible. Determining the area of all gamma ray peaks in this random coincidence free spectrum is not only necessary to calculate the gamma ray branching ratios but combined with the peak areas of the gamma ray singles spectrum we are able to determine experimentally the efficiency of the beta detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Primary cosmic ray particles with z 35 (VVH particles)

Large areas of nuclear emulsions and plastic detectors were exposed to the primary cosmic radiation during high altitude balloon flights. From the analysis of 141 particle tracks recorded during a total exposure of 1.3 x 10 to the 7th power sq m ster.sec., a charge spectrum of the VVH particles has been derived.

Blanford, G. E., Jr.↗

Primary cosmic ray particles with Z greater than 35 /VVH particles/

Large areas of nuclear emulsions and plastic detectors were exposed to the primary cosmic radiation during high-altitude balloon flights. From an analysis of 141 particle tracks recorded during a total exposure of 13,000,000 sq m-ster-sec, a charge spectrum of the VVH particles has been derived.

Blanford, G. E., Jr.↗

Linear Energy Transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLD's), plastic nuclear track detectors (PNTD's), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the COSMOS 1887 mission.

Parnell, T. A.↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT - Release 1.1.1: Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator, gas, and semiconductor features, the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Construction of the sPHENIX Detector and Status of Its Commissioning

sPHENIX is the first new major detector at RHIC in over twenty years. It is designed for pioneering studies of the Quark Gluon Plasma and Cold QCD phenomena using high-pT jet and heavy flavor probes with a broad kinematic reach and a capability to take large statistics sets of A+A, p+p and p+A data. sPHENIX construction was completed in April 2023. It was commissioned and took first Au+Au data in the RHIC 2023 Run. This paper describes the details of the detector design, challenges of sPHENIX construction, progress on the commissioning and first data from the RHIC 2023 run.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Science Symposium, 29th, and Symposium on Nuclear Power, 14th, Washington, DC, October 20-22, 1982, Proceedings

High-energy radiation detectors suitable for balloon-borne or space-based radiation event studies are described. The employment of NaI(Tl) scintillator bars for gamma ray detection is outlined, and the development of a fluorescent gated gas-filled scintillation proportional counter is reported. A high throughput nondispersive hard X ray spectrograph with angular resolution for cosmic bursts, transients, and sources has been constructed. Features of a sealed high pressure xenon filled imaging proportional counter with a 30 sq cm sensitive area are explored. Finally, the various radiation effects on electronic circuitry in a space environment are defined, and an MOS dosimeter for assaying the cumulative radiation flux in a spacecraft due to ambient conditions is characterized.

Davis, W. D.↗

Two-neutrino double electron capture of 124 Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of 124Xe through the process of two-neutrino double electron capture, utilizing a 1.39 kg × yr isotopic exposure from the first LZ science run. A half-life of $T$$^{2v2EC}_{1/2}$ = (1.09 ± 0.14 stat ± 0.05 sys ) x 10 22 yr is observed with a statistical significance of 8.3σ, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the 1.4σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT - Release 2.1.0: Organic Scintillators and Gas Detectors

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that post-processes output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. The focus of this release is on organic scintillator, gas detector, and associated capabilities, while semiconductor features are still under development. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. DRiFT also has several diagnostic and detector physics features relevant to neutron gas detector simulations including: gas detector wall effects, inactive areas at the end of detector tubes, and effects of a preamplifier. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ALTCRISS Project On Board the International Space Station

The Altcriss project aims to perform a long term survey of the radiation environment on board the International Space Station. Measurements are being performed with active and passive devices in different locations and orientations of the Russian segment of the station. The goal is perform a detailed evaluation of the differences in particle fluence and nuclear composition due to different shielding material and attitude of the station. The Sileye-3/Alteino detector is used to identify nuclei up to Iron in the energy range above approximately equal to 60 MeV/n; a number of passive dosimeters (TLDs, CR39) are also placed in the same location of Sileye-3 detector. Polyethylene shielding is periodically interposed in front of the detectors to evaluate the effectiveness of shielding on the nuclear component of the cosmic radiation. The project was submitted to ESA in reply to the AO the Life and Physical Science of 2004 and was begun in December 2005. Dosimeters and data cards are rotated every six months: up to now three launches of dosimeters and data cards have been performed and have been returned with the end expedition 12 and 13.

Cucinotta, Francis A.↗