A Leo Satellite Navigation Algorithm Based on GPS and Magnetometer Data

The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately, a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes. This work presents the development of a technique to eliminate numerical differentiation of the GPS phase measurements and also compares the use of one versus two GPS satellites.

Deutschmann, Julie↗

Approach-Phase Precision Landing with Hazard Relative Navigation: Terrestrial Test Campaign Results of the Morpheus/ALHAT Project

The Morpheus Project began in late 2009 as an ambitious e ort code-named Project M to integrate three ongoing multi-center NASA technology developments: humanoid robotics, liquid oxygen/liquid methane (LOX/LCH4) propulsion and Autonomous Precision Landing and Hazard Avoidance Technology (ALHAT) into a single engineering demonstration mission to be own to the Moon by 2013. The humanoid robot e ort was redirected to a deploy- ment of Robonaut 2 on the International Space Station in February of 2011 while Morpheus continued as a terrestrial eld test project integrating the existing ALHAT Project's tech- nologies into a sub-orbital ight system using the world's rst LOX/LCH4 main propulsion and reaction control system fed from the same blowdown tanks. A series of 33 tethered tests with the Morpheus 1.0 vehicle and Morpheus 1.5 vehicle were conducted from April 2011 - December 2013 before successful, sustained free ights with the primary Vertical Testbed (VTB) navigation con guration began with Free Flight 3 on December 10, 2013. Over the course of the following 12 free ights and 3 tethered ights, components of the ALHAT navigation system were integrated into the Morpheus vehicle, operations, and ight control loop. The ALHAT navigation system was integrated and run concurrently with the VTB navigation system as a reference and fail-safe option in ight (see touchdown position esti- mate comparisons in Fig. 1). Flight testing completed with Free Flight 15 on December 15, 2014 with a completely autonomous Hazard Detection and Avoidance (HDA), integration of surface relative and Hazard Relative Navigation (HRN) measurements into the onboard dual-state inertial estimator Kalman lter software, and landing within 2 meters of the VTB GPS-based navigation solution at the safe landing site target. This paper describes the Mor- pheus joint VTB/ALHAT navigation architecture, the sensors utilized during the terrestrial ight campaign, issues resolved during testing, and the navigation results from the ight tests.

Crain, Timothy P.↗

Cloud top remote sensing by airborne lidar

Observations of cloud top height, backscattering, and signal depolarization have been obtained by a lidar system operating onboard a high-altitude research aircraft. The transmitter for the cloud lidar system is a doubled Nd:YAG laser operating at 5 Hz. The system functions as a fully automated sensor under microprocessor control and operates from a nominal 19-km altitude. Measurements have been acquired over a wide variety of cloud cover in conjunction with passive visible and infrared measurements. Initial observation results are reported

Spinhirne, J. D.↗

Statistical Decomposition and Machine Learning to Clean In Situ Spaceflight Magnetic Field Measurements

Robust in situ magnetic field measurements are critical to understanding the various mechanisms that couple mass, momentum, and energy throughout our solar system. However, the spacecraft on which magnetometers are often deployed contaminate the magnetic field measurements via onboard subsystems including reaction wheels and magnetorquers. Two magnetometers can be deployed at different distances from the spacecraft to determine an approximation of the interfering field for subsequent removal, but constant data streams from both magnetometers can be impractical due to power and telemetry limitations. Here we propose a method to identify and remove time-varying magnetic interference from sources such as reaction wheels using statistical decomposition and convolutional neural networks, providing high-fidelity magnetic field data even in cases where dual-sensor measurements are not constantly available. For example, a measurement interval from the Parker Solar Probe outboard magnetometer experienced a 95.1% reduction in reaction wheel interference following application of the proposed technique.

magnetic field data↗

Lightweight, Miniature Inertial Measurement System

A miniature, lighter-weight, and highly accurate inertial navigation system (INS) is coupled with GPS receivers to provide stable and highly accurate positioning, attitude, and inertial measurements while being subjected to highly dynamic maneuvers. In contrast to conventional methods that use extensive, groundbased, real-time tracking and control units that are expensive, large, and require excessive amounts of power to operate, this method focuses on the development of an estimator that makes use of a low-cost, miniature accelerometer array fused with traditional measurement systems and GPS. Through the use of a position tracking estimation algorithm, onboard accelerometers are numerically integrated and transformed using attitude information to obtain an estimate of position in the inertial frame. Position and velocity estimates are subject to drift due to accelerometer sensor bias and high vibration over time, and so require the integration with GPS information using a Kalman filter to provide highly accurate and reliable inertial tracking estimations. The method implemented here uses the local gravitational field vector. Upon determining the location of the local gravitational field vector relative to two consecutive sensors, the orientation of the device may then be estimated, and the attitude determined. Improved attitude estimates further enhance the inertial position estimates. The device can be powered either by batteries, or by the power source onboard its target platforms. A DB9 port provides the I/O to external systems, and the device is designed to be mounted in a waterproof case for all-weather conditions.

Tang, Liang↗

In-situ exploration of Venus on a global scale : direct measurements of origins and evolution, meterology, dynamics, and chemistry by a long-duration aerial science station

Drifting in the strong winds of Venus under benign Earth-like temperature and pressure conditions, an instrumented balloon-borne science station presents a viable means to explore, in-situ, the Venusian atmosphere on a global scale. Flying over the ground at speeds exceeding 240 km/hour while floating in the Venusian skies near 55 km altitude for several weeks, such an aerostat can conduct a 'world tour' of our neighboring planet, as it circumnavigates the globe multiple times during its flight from equatorial to polar latitudes. Onboard science sensors can repeatedly and directly sample gas compositions, atmospheric pressures and temperatures and cloud particle properties, giving unprecedented insight into the chemical processes occurring within the sulfuric clouds. Additionally, interferometric tracking via Earth-based radio observatories can yield positions and windspeeds to better than 10 cm/sec over one-hour periods, providing important information for understanding the planet's meridional circulation and enigmatic zonal super-rotation, as well as local dynamics associated with meteorological processes. As well, hundreds of GCMS spectra collected during the flight can provide measurements of noble gas compositions and their isotopes with unprecedented accuracy, thereby enabling fundamental new insights into Venus's origin and evolution.

Venus↗

Dynamical in-orbit behavior of the Radio Astronomy Explorer satellite

Onboard sensors and associated ground based processing systems are used to maintain a well stabilized attitude for the RAE 1 in its near circular earth orbit despite the satellite's four extremely long and flexible antenna booms. Boom tip deflection pictures and central hub orientation measurements show that large boom vibrations and major attitude stability problems anticipated prior to launch have not materialized.

Walden, H.↗

Bridging the Last Mile with Open-Source Advancements: Empowering Communities through Fusion of Aerosol Optical Depth (AOD) Products from Multi-Satellite Sensors

Aerosol Optical Depth (AOD) is a crucial parameter for understanding atmospheric aerosol distribution and their impact on climate and air quality. With the growing number of Earth observation satellites, there is an abundance of AOD products derived from various sensors onboard both geostationary and low-orbit satellites. The availability of multiple datasets provides an opportunity to harness the strengths of each sensor and create comprehensive and accurate AOD datasets for climate and air quality studies at different temporal and spatial scales. Our NASA aerosol MEaSURES project has made significant strides in recent years by undertaking the ambitious task of developing an open-source package tailored for fusing AOD products from different sources. The package is based on OOP (Object-Oriented Programming) design and is implemented in Python modules. Generic interfaces enable easy inclusion of large and heterogeneous data. The package may be utilized to produce harmonized AOD datasets with enhanced spatial and temporal coverage. The latest version of the package is able to process and integrate the dark-target AOD data from six different sensors: AHI Himawari-8, ABI GOES-West, ABI GOES-East, MODIS AQUA, MODIS TERRA, and VIIRS SNPP. Rigorous validation and intercomparison studies have been performed to assess the accuracy and reliability of the fused AOD product against ground-based measurements and reference datasets. The open-source nature of the developed package ensures transparency, reproducibility, and community engagement. The research community and stakeholders can access, contribute to, and further improve the fusion methodology, making it adaptable to other studies, or expanding it to include new satellite data as they become available. In this poster presentation, we will introduce the accomplishments and challenges faced during the development of the open-source package for AOD data fusion, and demonstrate the advantages of combining AOD products from the six aforementioned satellite sensors. The presentation aims to foster discussions, collaborations, and future directions in integrating Earth observation and remote sensing data, which may contribute to a better understanding of atmospheric aerosols and their impacts on our environment.

Zhaohui Zhang↗

Advanced Libya-4 radiometric and atmospheric characterization utilizing MODIS and VIIRS full-scan reflective solar band measurements

The NASA Clouds and the Earth's Radiant Energy System (CERES) project provides observed flux and cloud products to the climate science community. The CERES instruments, along with the MODIS and VIIRS imagers, are onboard the Terra, Aqua, NPP, and NOAA20 satellites. In order to produce seamless multi-platform integrated products, long-term sensor stability and inter-calibration are required. Inter-calibration between sensors within the same sun-synchronous orbit relies on Earth invariant targets because simultaneous nadir overpasses are not possible. To facilitate inter-calibration efforts, the CERES Imager and Geostationary Calibration Group (IGCG) has improved the Libya-4 target characterization. Improvements include full scan angle characterization to enable daily observations, clear-sky identification using individual scan angle dynamic spatial homogeneity thresholds, and atmospheric corrections. The water vapor correction was found to be effective across the full scan, whereas the ozone and aerosol corrections were less effective. The atmospheric-corrected normalized radiance temporal fluctuations are similar across scan angles, spectral bands, and between the MODIS and VIIRS imagers, suggesting that the fluctuations are a result of the natural variability of the Libya-4 surface reflectance. The Libya-4 surface variability is more than likely caused by changes in the prevailing winds that alter sand dune orientation and resulting shadows. The full-scan-imager atmosphere and angle corrected reflected solar band radiance trend standard errors are between 0.6% and 1.0%, and for near-nadir observations, are between 0.5% and 0.8%. The advanced characterization suggests that the Libya-4 short-term surface reflectance anomalies may need to be considered for imager stability monitoring and inter-calibration efforts.

Libya-4 Pseudo-invariant Calibration Site↗

Microgravity acceleration measurement and environment characterization science (17-IML-1)

The Space Acceleration Measurement System (SAMS) is a general purpose instrumentation system designed to measure the accelerations onboard the Shuttle Orbiter and Shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigation into the microgravity environment of the vehicle. Acceleration measurements can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The prime objective for SAMS on the International Microgravity Lab (IML-1) mission will be to measure the accelerations experienced by the Fluid Experiment System (FES). The SAMS acceleration measurements for FES will be complemented by low level, low frequency acceleration measurements made by the Orbital Acceleration Research Experiment (OARE) installed on the shuttle. Secondary objectives for SAMS will be to measure accelerations at several specific locations to enable the acceleration transfer function of the Spacelab module to be analyzed. This analysis effort will be in conjunction with similar measurements analyses on other Spacelab missions.

Source record↗

Microgravity acceleration measurement environment characterization

The Space Acceleration Measurement System (SAMS) is a general-purpose instrumentation system designed to measure the accelerations onboard the shuttle Orbiter and shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigations into the microgravity environment of the vehicle. Acceleration measurement can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The SAMS was developed by NASA's Lewis Research Center (LeRC) in support of NASA's microgravity science programs. In the past, numerous acceleration measurement systems have flown on various space missions. These systems were tailored to measure accelerations for a narrow set of requirements and were limited in bandwidth, dynamic range, and recording capability. In addition, these systems were mission-peculiar and not easily modified for other applications or missions. The result has been an inability to accurately assess the expected microgravity environment prior to a mission for a particular experiment and/or location. The prime science objective for SAMS on the SL-J mission will be to measure the accelerations experienced by a multitude of experiments in the two racks of the Japanese First Materials Processing Test (FMPT). The FMPT consists of a variety of materials science and life science experiments contained in racks no. 7 and no. 10. The SAMS data will be made available to the FMPT principal investigators after the mission for their analysis with the FMPT data. A secondary science objective for SAMS will be the characterization of the acceleration environment of the Spacelab module. This will include an analysis of the acceleration transfer function of the Spacelab module which will utilize the FMPT acceleration measurement along with measurements at the rack no. 9 structure. Another analytical effort to be undertaken is a general characterization of the acceleration environment of the Spacelab as an orbiting laboratory. These analysis efforts will be in conjunction with similar measurements and analyses on other SAMS Spacelab missions.

Delombard, Richard↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

NASA Tech Briefs, October 2008

Topics covered include: Control Architecture for Robotic Agent Command and Sensing; Algorithm for Wavefront Sensing Using an Extended Scene; CO2 Sensors Based on Nanocrystalline SnO2 Doped with CuO; Improved Airborne System for Sensing Wildfires; VHF Wide-Band, Dual-Polarization Microstrip-Patch Antenna; Onboard Data Processor for Change-Detection Radar Imaging; Using LDPC Code Constraints to Aid Recovery of Symbol Timing; System for Measuring Flexing of a Large Spaceborne Structure; Integrated Formation Optical Communication and Estimation System; Making Superconducting Welds between Superconducting Wires; Method for Thermal Spraying of Coatings Using Resonant-Pulsed Combustion; Coating Reduces Ice Adhesion; Hybrid Multifoil Aerogel Thermal Insulation; SHINE Virtual Machine Model for In-flight Updates of Critical Mission Software; Mars Image Collection Mosaic Builder; Providing Internet Access to High-Resolution Mars Images; Providing Internet Access to High-Resolution Lunar Images; Expressions Module for the Satellite Orbit Analysis Program Virtual Satellite; Small-Body Extensions for the Satellite Orbit Analysis Program (SOAP); Scripting Module for the Satellite Orbit Analysis Program (SOAP); XML-Based SHINE Knowledge Base Interchange Language; Core Technical Capability Laboratory Management System; MRO SOW Daily Script; Tool for Inspecting Alignment of Twinaxial Connectors; An ATP System for Deep-Space Optical Communication; Polar Traverse Rover Instrument; Expert System Control of Plant Growth in an Enclosed Space; Detecting Phycocyanin-Pigmented Microbes in Reflected Light; DMAC and NMP as Electrolyte Additives for Li-Ion Cells; Mass Spectrometer Containing Multiple Fixed Collectors; Waveguide Harmonic Generator for the SIM; Whispering Gallery Mode Resonator with Orthogonally Reconfigurable Filter Function; Stable Calibration of Raman Lidar Water-Vapor Measurements; Bimaterial Thermal Compensators for WGM Resonators; Root Source Analysis/ValuStream[Trade Mark] - A Methodology for Identifying and Managing Risks; Ensemble: an Architecture for Mission-Operations Software; Object Recognition Using Feature-and Color-Based Methods; On-Orbit Multi-Field Wavefront Control with a Kalman Filter; and The Interplanetary Overlay Networking Protocol Accelerator.

Source record↗

Kalman Orbit Optimized Loop Tracking

Under certain conditions of low signal power and/or high noise, there is insufficient signal to noise ratio (SNR) to close tracking loops with individual signals on orbiting Global Navigation Satellite System (GNSS) receivers. In addition, the processing power available from flight computers is not great enough to implement a conventional ultra-tight coupling tracking loop. This work provides a method to track GNSS signals at very low SNR without the penalty of requiring very high processor throughput to calculate the loop parameters. The Kalman Orbit-Optimized Loop (KOOL) tracking approach constitutes a filter with a dynamic model and using the aggregate of information from all tracked GNSS signals to close the tracking loop for each signal. For applications where there is not a good dynamic model, such as very low orbits where atmospheric drag models may not be adequate to achieve the required accuracy, aiding from an IMU (inertial measurement unit) or other sensor will be added. The KOOL approach is based on research JPL has done to allow signal recovery from weak and scintillating signals observed during the use of GPS signals for limb sounding of the Earth s atmosphere. That approach uses the onboard PVT (position, velocity, time) solution to generate predictions for the range, range rate, and acceleration of the low-SNR signal. The low- SNR signal data are captured by a directed open loop. KOOL builds on the previous open loop tracking by including feedback and observable generation from the weak-signal channels so that the MSR receiver will continue to track and provide PVT, range, and Doppler data, even when all channels have low SNR.

Young, Lawrence E.↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

SAMS Acceleration Measurements on Mir (NASA Increment 4)

During NASA Increment 4 (January to May 1997), about 5 gigabytes of acceleration data were collected by the Space Acceleration Measurements System (SAMS) onboard the Russian Space Station, Mir. The data were recorded on 28 optical disks which were returned to Earth on STS-84. During this increment, SAMS data were collected in the Priroda module to support the Mir Structural Dynamics Experiment (MiSDE), the Binary Colloidal Alloy Tests (BCAT), Angular Liquid Bridge (ALB), Candle Flames in Microgravity (CFM), Diffusion Controlled Apparatus Module (DCAM), Enhanced Dynamic Load Sensors (EDLS), Forced Flow Flame Spreading Test (FFFr), Liquid Metal Diffusion (LMD), Protein Crystal Growth in Dewar (PCG/Dewar), Queen's University Experiments in Liquid Diffusion (QUELD), and Technical Evaluation of MIM (TEM). This report points out some of the salient features of the microgravity environment to which these experiments were exposed. Also documented are mission events of interest such as the docked phase of STS-84 operations, a Progress engine bum, Soyuz vehicle docking and undocking, and Progress vehicle docking. This report presents an overview of the SAMS acceleration measurements recorded by 10 Hz and 100 Hz sensor heads. The analyses included herein complement those presented in previous summary reports prepared by the Principal Investigator Microgravity Services (PIMS) group.

DeLombard, Richard↗

SAMS Acceleration Measurements on Mir From January to May 1997 (NASA Increment 4)

During NASA Increment 4 (January to May 1997), about 5 gigabytes of acceleration data were collected by the Space Acceleration Measurements System (SAMS) onboard the Russian Space Station, Mir. The data were recorded on 28 optical disks which were returned to Earth on STS-84. During this increment, SAMS data were collected in the Priroda module to support the Mir Structural Dynamics Experiment (MiSDE), the Binary Colloidal Alloy Tests (BCAT), Angular Liquid Bridge (ALB), Candle Flames in Microgravity (CFM), Diffusion Controlled Apparatus Module (DCAM), Enhanced Dynamic Load Sensors (EDLS), Forced Flow Flame Spreading Test (FFFT), Liquid Metal Diffusion (LMD), Protein Crystal Growth in Dewar (PCG/Dewar), Queen's University Experiments in Liquid Diffusion (QUELD), and Technical Evaluation of MIM (TEM). This report points out some of the salient features of the microgravity environment to which these experiments were exposed. Also documented are mission events of interest such as the docked phase of STS-84 operations, a Progress engine burn, Soyuz vehicle docking and undocking, and Progress vehicle docking. This report presents an overview of the SAMS acceleration measurements recorded by 10 Hz and 100 Hz sensor heads. The analyses included herein complement those presented in previous summary reports prepared by the Principal Investigator Microgravity Services (PIMS) group.

DeLombard, Richard↗

Altitude Registration of Limb-Scattered Radiation

One of the largest constraints to the retrieval of accurate ozone profiles from UV backscatter limb sounding sensors is altitude registration. Two methods, the Rayleigh scattering attitude sensing (RSAS) and absolute radiance residual method (ARRM), are able to determine altitude registration to the accuracy necessary for long-term ozone monitoring. The methods compare model calculations of radiances to measured radiances and are independent of onboard tracking devices. RSAS determines absolute altitude errors, but, because the method is susceptible to aerosol interference, it is limited to latitudes and time periods with minimal aerosol contamination. ARRM, a new technique introduced in this paper, can be applied across all seasons and altitudes. However, it is only appropriate for relative altitude error estimates. The application of RSAS to Limb Profiler (LP) measurements from the Ozone Mapping and Profiler Suite (OMPS) on board the Suomi NPP (SNPP) satellite indicates tangent height (TH) errors greater than 1 km with an absolute accuracy of +/-200 m. Results using ARRM indicate a approx. 300 to 400m intra-orbital TH change varying seasonally +/-100 m, likely due to either errors in the spacecraft pointing or in the geopotential height (GPH) data that we use in our analysis. ARRM shows a change of approx. 200m over 5 years with a relative accuracy (a long-term accuracy) of 100m outside the polar regions.