Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscillations control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

TRUST Nonlinear Dynamics Testbed Assessment

The following assessment evaluates the efficacy of the control script for carrying out a linear signal to generate a linear mechanical response of the system: the TRUST nonlinear dynamics (TRUSTND) testbed. The hardware has three main components: the controller (NI PXIe 8861) embedded in the National Instruments chassis (NI PXIe 1092), the signal amplifier (The Modal Shop Linear Power Amplifier 2050E09) to amplify the output of a custom LabVIEW script, and a shaker (The Modal Shop Electrodynamic Exciter 2075E) where wave spring specimens live and are tested within the attached aluminum testbed (center mass). Different kinds of signals (single-tone, swept frequency and white noise) were sent through this hardware in the E-1 lab space at TA-53. First, the linearity of the setup was tested by specifying a sine wave in the control script and checking the quality of the oscillations in a wave spring (McMaster-Carr 9714K19 [1]). When passing a sine wave through the amplifier was succeeded, the frequency response of the wave spring was tested with white noise for comparison to finite-element model predictions. The testbed outputs a repeatable, linear response to the input excitation when used with the wave spring. These measurements reduce the uncertainty associated with the testbed and test procedure to better characterize uncertainty associated with material behavior (SX358 foam samples) in future tests

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information Entropy as Quantifier of Potential Predictability in the Tropical Indo-Pacific Basin

Global warming is posed to modify the modes of variability that control much of the climate predictability at seasonal to interannual scales. The quantification of changes in climate predictability over any given amount of time, however, remains challenging. Here we build upon recent advances in non-linear dynamical systems theory and introduce the climate community to an information entropy quantifier based on recurrence. The entropy, or complexity of a system is associated with microstates that recur over time in the time-series that define the system, and therefore to its predictability potential. A computationally fast method to evaluate the entropy is applied to the investigation of the information entropy of sea surface temperature in the tropical Pacific and Indian Oceans, focusing on boreal fall. In this season the predictability of the basins is controlled by two regularly varying non-linear oscillations, the El Niño-Southern Oscillation and the Indian Ocean Dipole. We compute and compare the entropy in simulations from the CMIP5 catalog from the historical period and RCP8.5 scenario, and in reanalysis datasets. Discrepancies are found between the models and the reanalysis, and no robust changes in predictability can be identified in future projections. The Indian Ocean and the equatorial Pacific emerge as troublesome areas where the modeled entropy differs the most from that of the reanalysis in many models. A brief investigation of the source of the bias points to a poor representation of the ocean mean state and basins' connectivity at the Indonesian Throughflow.

54 ENVIRONMENTAL SCIENCES↗

Design Study for Bio-Oil Production from Biomass Using a Dual Fluidized-Bed Reactor

To evaluate the re-design and reconfiguration of a dual-fluidized bed (DFB) gasification system into a recirculating pyrolysis reactor, Computation Fluid Dynamic (CFD) simulations of the system were conducted. The Barracuda Virtual Reactor® computational particle fluid dynamic code was used to perform simulations of the pyrolysis process. Modeling of the chemical reaction kinetics for both gas phase and solid particle phase were included. The recirculating pyrolysis reactor shown in Fig. 1a is based on a bubbling-bed biomass pyrolyzer and a riser combustor to convert the remaining char. The operational differences in the re-configuration of the DFB gasification system into a recirculating pyrolysis system for the production of bio-oil are (1) replacement of a low-surface area inert bed material with a high-surface-area bed material that has acidic properties to provide catalytic activity for the production of bio-oil with reduced oxygen content, (2) lower temperature and residence time for bio-oil production from pyrolysis, (3) replacement of the fluidization gas in the bubbling bed pyrolyzer from steam to nitrogen, and (4) the reduction of pyrolyzer freeboard volume. The bed material used for catalytic pyrolysis is Sasol 300 (300-micron dia., bulk density 0.94 kg/l, and surface area 130 m2/g) and is a theta-alumina with mild acidity. This is in comparison with previous standard bed material Carbo HSP (430-micron dia., bulk density 2.01 kg/l, and surface area 0.03 m2/g) used for gasification. For bio-oil production, pyrolysis in the bubbling bed requires temperatures in the range of 550 C in comparison with gasification temperatures near 850 C. To attain this lower temperature requires management of the energy mass balances, with control of the bed material recirculation rate between bubbling bed pyrolyzer and riser combustor, the introduction of a nitrogen purge in the pyrolyzer, and adjusting the pressure balance between the two vessels. To extract bio-oil from the pyrolysis reactor with a snorkel, two different freeboard configurations were evaluated. In Fig. 1 b the existing high freeboard configuration is shown and in Fig. 1 c the reduced freeboard design is presented. The introduction of a nitrogen purge for the high free board configuration provided the highest bio-oil production from the CFD simulations. To decrease the bed-material circulation rate, primary and secondary air on the combustor side were reduced, and the pressure on the combustor was slightly increased. A portion of the biomass and bio-oil was observed to be transported to the combustor, leading to a smaller pyrolysis yield. The control of the pyrolyzer temperature is performed by controlling the circulation rate. Good fluidization of the bubbling bed and cascade PID control are required to keep the temperature from oscillating due to large time delay experienced when changing primary and secondary air. (a) (b) (c) Figure 1. (a) Dual Fluidized Bed pyrolysis system configuration, (b) mole fraction of nonpolar biooil in high freeboard configuration, and (c) mole fraction of nonpolar bio-oil in low freeboard configuration with nitrogen purge introduced in both configurations.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Towards Universal Non-Dimensional Characterization of the Oscillatory Dynamics of Wind Turbine Rotors of Multiple Sizes

One concern in the field of Horizontal Axis Wind Turbines (HAWTs) is what control strategies are needed to handle gust pulses in the wind to prevent extreme oscillations of the blades to reduce fatigue stress, prevent blade rupture, and extend the turbine’s operational life. In order to design innovative control strategies to modify the blade’s oscillatory response, it is crucial to establish the fundamental vibrational behavior of the blades when excited by gust pulses of different frequencies and amplitudes present in the fluctuating wind inflow. In a series of previous works, the authors presented a novel Reduced-Order Characterization (ROC) technique that provided an energy-based characterization of the fundamental modes of oscillation of wind turbine rotors when excited by combinations of wind gust pulses of different frequencies and amplitudes. The main focus of the present work is to extend these original notions of energy-based ROC to a universal technique expressed in terms of non-dimensional quantities that could be applied to turbines of any size, operating in any set of wind conditions, as long as they share geometrical and material similarity. The ROC technique provides a simple formula that is capable of predicting the dominant vibrational modes of a blade with sufficient precision to be useful in the determination of a control decision that can be computed in real time, an aspect of fundamental importance in dealing with rapid fluctuations in wind conditions.

Yates, North (ORCID:000900052204261X)↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

Comparative Analysis of Inter-Area Oscillations in the US Eastern and Western Interconnections

This paper presents a comparative analysis of interarea oscillations in the US Eastern and Western Interconnections using frequency disturbance data collected from the advanced wide-area Frequency Monitoring Network (FNET/GridEye), enabling us to investigate and compare the oscillation characteristics of both regions. The study analyzes the statistical data from the two interconnections, including total oscillation events, average dominant frequencies, damping ratios, and maximum amplitudes. We also explore the impact of seasonal and daily variations on oscillation occurrences and the influence of different grid topologies and operational practices. The results provide insights into both interconnections' stability and control characteristics, offering valuable information for power system operators to enhance grid stability and oscillation suppression measures.

Fu, Hao [University of Tennessee, Knoxville (UTK)]↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mapping the Temperature-dependent and network site-specific onset of spectral diffusion at the surface of a water cluster cage

We explore the kinetic processes that sustain equilibrium in a microscopic, finite system. This is accomplished by monitoring the spontaneous, time-dependent frequency evolution (the frequency autocorrelation) of a single OH oscillator, embedded in a water cluster held in a temperature-controlled ion trap. The measurements are carried out by applying two-color, IR-IR photodissociation mass spectrometry to the D3O+?(HDO)(D2O)19 isotopologue of the “magic number” protonated water cluster, H+?(H2O)21. The OH group can occupy any one of the five spectroscopically distinct sites in the distorted pentagonal dodecahedron cage structure. The OH frequency is observed to evolve over tens of milliseconds in the temperature range (90-120 K). Starting at 100 K, large “jumps” are observed between two OH frequencies separated by ~300 cm-1 indicating migration of the OH group from the bound OH site at 3350 cm-1 to the free position at 3686 cm-1. Increasing the temperature to 110 K leads to partial interconversion among many sites. All sites are observed to interconvert at 120 K such that the distribution of the unique OH group among them adopts the form one would expect for a canonical ensemble. The spectral dynamics displayed by the clusters thus offer an unprecedented view into the molecular-level processes that drive spectral diffusion in an extended network of water molecules.

Yang, Nan↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

Catalytic Resonance Theory: Experimental and Kinetic Interpretation of Programmable Catalysis

The complexity of programmable catalysts that change in the physical or electronic state on the time scale of a catalytic turnover results in uncertainty in the kinetic outcome of common measurements with dynamic catalyst experiments. To provide an interpretation of utility to experimentalists, a general programmable catalytic reaction exhibiting high turnover efficiency was simulated to understand the kinetic behavior of catalysts with varying frequency, binding energy, oscillation amplitude, and minimum oscillation binding energy at different temperatures and reactant gas pressures. The time-averaged catalytic rate for varying temperature in the form of an Arrhenius plot exhibited three distinct kinetic regimes, with the intermediate temperatures or applied frequencies exhibiting zero slope, indicative of barrier-free kinetic control. Transitions in experimentally measurable kinetic regimes with both temperature and applied catalyst oscillation frequency were associated with transitions in the sensitivity of reaction rate constants and degrees of rate control. Furthermore, these distinct kinetic macroscopic features specific to programmable catalysts were identified for observation in experimental dynamic kinetic measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Considerations in Long-Baseline Neutrino Oscillation Measurements

Long-baseline neutrino oscillation experiments, which are among the largest neutrino experiments in the world, have extensive physics programs to make precision measurements of three-flavor oscillation parameters, search for physics beyond the Standard Model, and study neutrinos from astrophysical sources. In this article, experimental considerations, including oscillation phenomenology, detector and experiment design, and analysis strategies, are described, with a focus on the three-flavor oscillation measurements. Current and future experiments are discussed, and significant sources of systematic uncertainty, along with mitigation strategies, are emphasized as control of systematic uncertainty is critical for success in precise measurement of long-baseline oscillation parameters. This article is structured as a primer for those new to this area of experimental work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards an intuitive application of WEC control co-design

A simple co-design example in a reduced parameter space is presented for an oscillating flap device. Initially, the WEC geometry and mass properties are considered along with drivetrain gear ratio, inertia, motor constant and stiffness under both PI and optimal control. This parameter space is reduced to those to which performance is most sensitive for a fixed geometry. The gear ratio, drivetrain stiffness, and flap mass are found to be the most impactful design criteria as they can create orders of magnitude variations in power performance. The performance of the optimized system is compared with several sub-optimal variants in terms of electrical and mechanical power capture, transmission coefficients, and transducer power gain. Notably, though substantial power capture improvements are demonstrated when an optimal controller is employed, this power capture remains sensitive to appropriate selections of drivetrain and flap design parameters, implying that control co-design procedures remain necessary for high-performing WECs. Furthermore, a number of practical caveats and extensions to the presented co-design methodology are suggested, including the characterization of system static friction, especially in the presence of high gear ratios.

Control co-design↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Modeling of the metal–insulator transition temperature in alio-valently doped VO 2 through symbolic regression

The correlated semiconductor vanadium dioxide (VO 2 ) exhibits an insulator–metal transition (IMT) near room temperature, which is of interest in various device applications. Precise IMT temperature control is crucial to determine the use cases across technologies such as thermochromic windows, actuators for robots or neuronal oscillators. Doping the cation or anion sites can modulate the IMT by several tens of degrees and control hysteresis. However, modeling the effects of control parameters (e.g., doping concentration, type of dopants) is challenging due to complex experimental procedures and limited data, hindering the use of traditional data-driven machine learning approaches. Symbolic regression (SR) can bridge this gap by identifying nonlinear expressions connecting key input parameters to target properties, even with small data sets. In this work, we develop SR models to capture the IMT trends in VO 2 influenced by different dopant parameters. Using experimental data from the literature, our study reveals a dual nature of the IMT temperature with varying tungsten (W) doping concentrations. The symbolic model captures data trends and accounts for experimental variability, providing a complementary approach to first-principles calculations. Our feature-driven analysis across a broader class of dopants informs selectivity and provides qualitative insights into tuning phase transition properties valuable for neuromorphic computing and thermochromic windows.

36 MATERIALS SCIENCE↗