Total ozone determination by spectroradiometry in the middle ultraviolet

A method has been developed to determine total ozone from multispectral measurements of the direct solar irradiance. The total ozone is determined by a least squares fit to the spectrum between 290 nm and 380 nm. The aerosol extinction is accounted for by expanding it in a power series in wavelength; use of the linear term proved adequate. A mobile laboratory incorporating a sky scanner has been developed and used to obtain data to verify the method. Sun tracking, wavelength setting of the double monochromator, and data acquisition are under control of a minicomputer. Results obtained at Wallops Island, Virginia, and Palestine, Texas, agree well with simultaneous Dobson and Canterbury spectrometer and balloon ECC ozonesonde values. The wavelength calibration of the monochromator and the values for the normalized ozone absorption are the most important factors in an accurate determination of total ozone.

Garrison, L. M.↗

Remote sensing of the ozone profile in the lower stratosphere using UV and IR measurements from Nimbus 4

With a three-parameter analytical model, the ozone profile below 10 mbar to the surface is derived from the Nimbus 4 satellite backscattered ultraviolet and infrared measurements. Comparison of the derived profiles with those observed by ozonesondes shows that gross features are satisfactorily reproduced. Meridional cross section of the ozone partial pressure derived from the satellite data reveal the significant equator-to-pole features, as well as seasonal variability. An examination of the sensitivity of the method shows that an error in infrared radiance of approximately 1 erg leads to an error of about 10 mbar in the weighted mean pressure of the ozone layer in the tropics.

Prabhakara, C.↗

The observed ozone flux by transient eddies, 0-30 km

Ozonesonde data are matched with concomitant rawinsonde data to provide a direct determination of horizontal, meridional, flux of ozone by the transient eddies. Data are from 27 stations in 4 regions: eastern and western North America, western Europe, and Japan. Results confirm the existence of significant northward flux near 40 deg N, 10-18 km, in winter and spring, as shown by previous investigators. However, areas of significant equatorward flux are found at high mid-latitudes, 10-16 km, over North America in winter and spring, and at all 3 Japanese stations, 10-18 km, in spring. Trasient eddy fluxes are typically small in summer, and are also small throughout the troposphere and most of the middle stratosphere.

Wilcox, R. W.↗

Recent assessment of the performance and accuracy of a chemiluminescent rocket sonde for upper atmospheric ozone measurements

The chemiluminescent rocket ozonesonde utilizing rhodamine-B as a detector and self-pumping for air sampling has been improved. The instrument employs standard meteorological sounding systems and is the only technique available for routine nighttime ozone measurements above balloon altitudes. The chemiluminescent detector, when properly calibrated, is shown to be specific to ozone, stable, and of sufficient sensitivity for accurate measurements of ozone from about 65-20 km. An error analysis indicates that the measured ozone profiles have an absolute accuracy of about + or - 12% and a precision of about + or - 6%. Approximately 20 flights have been conducted for geophysical investigations, while additional flights were conducted with other rocket and satellite ozone soundings for comparisons. In general, these comparisons showed good agreement.

Hilsenrath, E.↗

LIMS Instrument Package (LIP) balloon experiment: Nimbus 7 satellite correlative temperature, ozone, water vapor, and nitric acid measurements

The Limb Infrared Monitor of the Stratosphere (LIMS) LIP balloon experiment was used to obtain correlative temperature, ozone, water vapor, and nitric acid data at altitudes between 10 and 36 kilometers. The performance of the LIMS sensor flown on the Nimbus 7 Satellite was assessed. The LIP consists of the modified electrochemical concentration cell ozonesonde, the ultraviolet absorption photometric of ozone, the water vapor infrared radiometer sonde, the chemical absorption filter instrument for nitric acid vapor, and the infrared radiometer for nitric acid vapor. The limb instrument package (LIP), its correlative sensors, and the resulting data obtained from an engineering and four correlative flights are described.

Lee, R. B., III↗

Stratospheric instruments and analyses

The Instruments are divided into two groups, ground based instruments and satellite-borne instruments. The ground based instruments include a Dobson ozone spectrophotometer, a filter ozonometer, and ozonesondes. The satellite-borne instruments include: a backscatter ultraviolet spectrometer, a high resolution infrared radiation sounder, a infrared interferometer spectrometer, a limb radiance inversion radiometer, and multichannel filter radiometer. A list of investigations using stratospheric satellite data is presented.

Source record↗

Cabin ozone and tropopause definition

A method to estimate ozone profiles is based on knowing the total ozone which may come from any observational system available such as Dobson photometers that are available from NMC forecasts and used operationally in flight planning. From this an ozone profile at selected pressure levels is obtained. The technique was based on five years of ozonesonde data. So far, models have been developed for winter, spring, and fall.

Belmont, A. D.↗

Periodic and aperiodic ozone variations in the middle and upper stratosphere

Umkehr, ozonesonde and satellite observations are used to determine the height/latitude distribution of the amplitude and phase of the periodic components of the variation in the ozone mixing ratio in the middle and upper stratosphere. The amplitude of the first (annual) harmonic is found to be small in the subtropics and to increase to a maximum at polar latitudes. In addition, it increases with height in the mid and upper stratosphere to an apparent maximum just below the stratosphere. The second (semi-annual) harmonic possesses an amplitude that is largest in tropical regions and in subpolar regions at a level of about 40 km. Very little ozone variation is seen above 30 km with dominant periods close to the quasi-biennial period of total ozone observed in the tropics. The percentage of the total variance of the ozone mixing ratio accounted for by the first harmonic is found to be larger than 60 percent at all heights from 20 deg to 60 deg latitude in both hemispheres (except near 40 km in the Northern Hemisphere).

London, J.↗

Ozone intercomparisons from the Balloon Intercomparison Campaign

Intercomparisons of remote and in-situ techniques used to measure stratospheric ozone are made using results obtained on the Balloon Intercomparison Campaign of 1982 and 1983. Two in-situ and four remote instruments participated. These included ECC ozonesondes, a UV absorption photometer, and microwave emission, IR emission, and absorption spectrometers. Differences are generally less than 15 percent, and are within the quoted error bars. Flights which involved different sets of instruments were made on four separate days, and results are intercompared in plots of ozone density versus altitude. A careful assessment of errors was made for each instrument, and a plot of absolute errors versus altitude is given.

Robbins, D.↗

Causes and effects of a hole

Preliminary results from the U.S. National Ozone Expedition (NOZE) to Antarctica are reviewed. The NOZE ozonesonde measurements showed significant vertical structure in the hole, with 80 percent depletion in some of the 1 km layers but only 20 percent in adjacent layers. The depletion was confined to the 12-20 km region, beginning first at higher altitude and progressing downward. This is strong evidence against the theory that the ozone hole is due to solar activity producing odd nitrogen at high altitudes which is transported downwards, leading to enhanced odd-nitrogen catalytic cycles that destroy ozone. Nitrous oxide data show unusually low concentrations within the polar vortex, which is evidence against the theory that the hole is caused by a purely dynamical mechanism in which rising air motions within the polar vortex lead to reduced column densities of ozone. It is tentatively concluded that a chemical mechanism involving man-made chlorofluorocarbons is the likely cause of ozone depletion in the hole.

Margitan, J. J.↗

Middle atmosphere trace constituents; Proceedings of Workshop 9 of the Twenty-sixth COSPAR Plenary Meeting, Toulouse, France, June 30-July 11, 1986

Papers are presented on a reference model for stratospheric NO2, a proposed reference model for nitric acid, proposed reference models for ozone, and a background stratospheric aerosol reference model. Other topics include a comparison between the observed and calculated distributions of trace species in the middle atmosphere, recent measurements of trace constituents from rocket and balloon probes, NO2 field observations in the stratosphere during the MAP/GLOBUS Campaign in 1983 and 1985, and the vertical distribution of ozone in the equatorial zone. Also considered are precision measurements of stratospheric ozone profiles by rocket-borne optical ozonesondes, vertical profiles of source gases at tropical latitudes, and measurements of stratospheric trace constituent distributions from balloon-borne far infrared observations.

Keating, G. M.↗

Toward an improved global network for determination of tropospheric ozone climatology and trends

Current data on ozone variability on daily, monthly, annual, and interannual time scales were used for a standard trend-prediction analysis. Using the results of this analysis, together with a quantitative theory that defines the 'effectively sampled region' for an observing station, a definition was developed for a global network capable of determining ozone climatology and ozone trends with uncertainties not above 1 percent per year at the 95 percent confidence level. The definition indicates a need for at least a doubling of the present number of stations; the areas where more stations are most needed include the oceans, most of Asia, Africa, and South America. It is pointed out that differential absorption lidar ozone instruments have the potential for far more frequent measurements of ozone vertical profiles and, hence, potentially more accurate climatology and trend determinations than the ozonesondes; however, the differential-absorption lidar ozone measurements may produce a biased data set above the cloud base.

Prinn, Ronald G.↗

Atmospheric ozone at South Pole, Antarctica, in 1986

Results of NOAA's measurements of the ozone vertical distributions at the South Pole and of the annual course of total ozone, conducted in 1986 with balloon-borne electrochemical concentration cell (ECC) ozonesondes and a Dobson spectrophotometer, are described. The major finding was that the stratospheric ozone decreases abruptly between September 20 and October 15, with the bulk decrease occurring between 12 and 21 km. In this period, the column ozone and ozone volume mixing ratio at 16 km (the altitude of the normal ozone maximum at South Pole) decreased by 78 percent, and column ozone between 12 and 21 km decreased by 50 percent. The results of these measurements are compared with data obtained in 1971, and the changes observed in the ozone vertical distributions and in the temporal variations of atmospheric ozone are discussed.

Komhyr, W. D.↗

CANOZE measurements of the Arctic ozone hole

In CANOZE 1 (Canadian Ozone Experiment), a series of 20 ozone profile measurements were made in April, 1986 from Alert at 82.5 N. CANOZE is the Canadian program for study of the Arctic winter ozone layer. In CANOZE 2, ozone profile measurements were made at Saskatoon, Edmonton, Churchill and Resolute during February and March, 1987 with ECC ozonesondes. Ground based measurements of column ozone, nitrogen dioxide and hydrochloric acid were conducted at Saskatoon. Two STRATOPROBE balloon flights were conducted on February 26 and March 19, 1987. Two aerosol flights were conducted by the University of Wyoming. The overall results of this study will be reported and compared with the NOZE findings. The results from CANOZE 3 in 1988, are also discussed. In 1988, as part of CANOZE 3, STRATOPROBE balloon flights were conducted from Saskatchewan on January 27 and February 13. A new lightweight infrared instrument was developed and test flown. A science flight was successfully conducted from Alert (82.5 N) on March 9, 1988 when the vortex was close to Alert; a good measurement of the profile of nitric acid was obtained. Overall, the Arctic spring ozone layer exhibits many of the features of the Antarctic ozone phenomenon, although there is obviously not a hole present every year. The Arctic ozone field in March, 1986 demonstrated many similarities to the Antarctic ozone hole. The TOMS imagery showed a crater structure in the ozone field similar to the Antarctic crater in October. Depleted layers of ozone were found in the profiles around 15 km, very similar to those reported from McMurdo. Enhanced levels of nitric acid were measured in air which had earlier been in the vortex. The TOMS imagery for March 1987 did not show an ozone crater, but will be examined for an ozone crater in February and March, 1988, the target date for the CANOZE 3 project.

Evans, W. F. J.↗

Brewer spectrophotometer measurements in the Canadian Arctic

In the winters of 1987 and 1988 measurements were conducted with the Brewer Spectrophotometer at Alert (82.5 N) and Resolute (74.5 N). The measurements were conducted as part of our Canadian Program to search for an Arctic Ozone Hole (CANOZE). Ozone measurements were conducted in the months of December, January and February using the moon as a light source. The total ozone measurements will be compared with ozonesonde profiles, from ECC sondes, flown once per week from Alert and Resolute. A modified Brewer Spectrophotometer was used in a special study to search for chlorine dioxide at Alert in March 1987. Ground based observations at Saskatoon in February and at Alert in March 1987 failed to detect any measureable chlorine dioxide. Interference from another absorbing gas, which we speculate may be nitrous acid, prevented the measurements at the low levels of chlorine dioxide detected in the Southern Hemisphere by Solomon et al.

Kerr, J. B.↗

Validation of SAGE II ozone measurements

Five ozone profiles from the Stratospheric Aerosol and Gas Experiment (SAGE) II are compared with coincident ozonesonde measurements obtained at Natal, Brazil, and Wallops Island, Virginia. It is shown that the mean difference between all of the measurements is about 1 percent and that the agreement is within 7 percent at altitudes between 20 and 53 km. Good agreement is also found for ozone mixing ratios on pressure surfaces. It is concluded that the SAGE II profiles provide useful ozone information up to about 60 km altitude.

Cunnold, D. M.↗

Reconstruction of O3 and N2O fields from ER-2, DC-8, and balloon observations

Measurements of N2O and O3 during the Airborne Arctic Stratospheric Expedition have been composited using the potential vorticity and potential temperature of each measurement as coordinates. For ozone, data sources included the ER-2 and balloon ozonesonde in situ measurements, DC-8 DIAL lidar, and Stratospheric Aerosol and Gas Experiment satellite profiles. For N2O, only ER-2 data were used. These chemical composites have been reconstructed onto average meteorological fields for the mission in a latitude-altitude cross section, yielding a picture of the chemical composition of the polar vortex during this period. Tracers inside the vortex show an apparent descent of about 2 km relative to those outside, resulting in an apparent chemical edge on isentropic and isobaric surfaces.

Schoeberl, Mark R.↗

Comparison of SAGE II ozone measurements and ozone soundings at Uccle (Belgium) during the period February 1985 to January 1986

The ozone profiles obtained from 24 balloon soundings at Uccle (50 deg 48 min N, 4 deg 21 min E) made with electrochemical ozonesondes were used as correlative data for SAGE II ozone profiles retrieved within a distance of at most 600 km from Uccle. The agreement between the two data sets is in general quite good, especially for profiles nearly coincident in time and space, and during periods of little dynamic activity over the area considered. The percent difference between the ozone column density of the mean balloon and SAGE profile is 4.4 percent (-3.3) percent in the altitude region between 10 and 26 km. From a statistical analysis it appears that there is a small but meaningful difference between the mean profiles at the level of the ozone maximum and around the 30-km level. An error analysis of both data sets give similar results, leading to the conclusion that these differences are instrumentally induced. However, differences between the mean profiles in the lower stratosphere are probably real and due to the high ozone variability in time and space in that altitude region.

De Muer, D.↗