Search NASA⌕ Search

SEARCH · Search NASA

Results for “parallel planes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Wide-angle effects for peculiar velocities

ABSTRACT The line-of-sight peculiar velocities of galaxies contribute to their observed redshifts, breaking the translational invariance of galaxy clustering down to a rotational invariance around the observer. This becomes important when the line-of-sight direction varies significantly across a survey, leading to what are known as ‘wide-angle’ effects in redshift-space distortions. Wide-angle effects will also be present in measurements of the momentum field, i.e. the galaxy density-weighted velocity field, in upcoming peculiar velocity surveys. In this work, we study how wide-angle effects modify the predicted correlation function and power spectrum for momentum statistics, both in autocorrelation and in cross-correlation with the density field. Using both linear theory and the Zel'dovich approximation, we find that deviations from the plane-parallel limit are large and could become important in data analysis for low-redshift surveys. We point out that even multipoles in the cross-correlation between density and momentum are non-zero regardless of the choice of line of sight, and therefore contain new cosmological information that could be exploited. We discuss configuration space, Fourier space, and spherical analyses; providing exact expressions in each case rather than relying on an expansion in small angles. We hope these expressions will be of use in the analysis of upcoming surveys for redshift-space distortions and peculiar velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

Interface, bulk and surface structure of heteroepitaxial altermagnetic α-MnTe films grown on GaAs(111)

Epitaxial MnTe films have recently seen a surge in research into their altermagnetic semiconducting properties. However, those properties may be extremely sensitive to structural and chemical modifications. We report a detailed investigation of the synthesis of the altermagnet α-MnTe on GaAs(111), which reveals the bulk defect structure of this material, the mechanism by which it releases strain from the underlying substrate, and the impact of oxidation on its surface. X-ray diffraction measurements show that α-MnTe layers with thicknesses spanning 45 to 640 nm acquire lattice parameters different from bulk, mostly due to thermal strain caused by the substrate rather than strain from the lattice mismatch. Through high-resolution transmission electron microscopy (TEM) measurement, we then unveil a misfit dislocation array at the interface, revealing the mechanism by which lattice strain is relaxed. TEM also reveals a stacking fault in the bulk, occurring along a glide plane parallel to the interface. The combination of TEM with polarized neutron reflectometry measurements finally reveals the impact of oxidation on the chemistry of the surface of uncapped MnTe. Furthermore, or findings highlight the subtle role of epitaxy in altering the structure of α-MnTe, providing potential opportunities to tune the altermagnetic properties of this material.

Altermagnets↗

Flow of the normal component of He-II about bluff objects observed with He$^*_2$ excimers

Flow of the normal fluid component of He II about a cylinder and flat plate in a channel with a square cross-section was observed by tracking clouds of He$^*_2$ excimers. Flow was produced using a lithographically patterned heater. The direction and speed of flow projected onto a plane parallel to the axis of the channel and perpendicular to the heater exhibited significant change with time even after the heater was turned off. Flow was recorded in movies. Excimers moved at least as fast as could be recorded by the camera. Velocity vector field maps of flow suggest formation of structures downstream of the cylinder object that are consistent with parts of eddies. Here, in this paper, we establish a foundation to observe normal component flow of a quantum fluid over centimeters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Galaxy bispectrum in the spherical Fourier-Bessel basis

The bispectrum, the three-point correlation in Fourier space, is a crucial statistic for studying many effects targeted by the next-generation galaxy surveys, such as primordial non-Gaussianity (PNG) and general relativistic (GR) effects on large scales. In this work we develop a formalism for the bispectrum in the spherical Fourier-Bessel (SFB) basis—a natural basis for computing correlation functions on the curved sky, as it diagonalizes the Laplacian operator in spherical coordinates. Working in the SFB basis allows for line-of-sight effects such as redshift space distortions and GR to be accounted for exactly, i.e., without having to resort to perturbative expansions to go beyond the plane-parallel approximation. Only analytic results for the SFB bispectrum exist in the literature given the intensive computations needed. We numerically calculate the SFB bispectrum for the first time, enabled by a few techniques: We implement a template decomposition of the redshift-space kernel Z 2 into Legendre polynomials, and separately treat the PNG and velocity-divergence terms. We derive an identity to integrate a product of three spherical harmonics connected by a Dirac delta function as a simple sum and use it to investigate the limit of a homogeneous and isotropic Universe. Furthermore, we present a formalism for convolving the signal with separable window functions and use a toy spherically symmetric window to demonstrate the computation and give insights into the properties of the observed bispectrum signal. While our implementation remains computationally challenging, it is a step toward a feasible full extraction of information on large scales via a SFB bispectrum analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions

A description is given of new tools to facilitate model building and refinement into electron cryo-microscopy reconstructions. The recent rapid development of single-particle electron cryo-microscopy (cryo-EM) now allows structures to be solved by this method at resolutions close to 3 Å. Here, a number of tools to facilitate the interpretation of EM reconstructions with stereochemically reasonable all-atom models are described. The BALBES database has been repurposed as a tool for identifying protein folds from density maps. Modifications to Coot, including new Jiggle Fit and morphing tools and improved handling of nucleic acids, enhance its functionality for interpreting EM maps. REFMAC has been modified for optimal fitting of atomic models into EM maps. As external structural information can enhance the reliability of the derived atomic models, stabilize refinement and reduce overfitting, ProSMART has been extended to generate interatomic distance restraints from nucleic acid reference structures, and a new tool, LIBG, has been developed to generate nucleic acid base-pair and parallel-plane restraints. Furthermore, restraint generation has been integrated with visualization and editing in Coot, and these restraints have been applied to both real-space refinement in Coot and reciprocal-space refinement in REFMAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Near Ideal Edge Termination Technique for 4500V 4H-SiC Devices: The Hybrid Junction Termination Extension

This letter presents a new edge termination technique named a hybrid junction termination extension (Hybrid-JTE), which combines ring-assisted JTE and multiple floating zone JTE. Based on the parameters of the drift layer specified by the wafer vendor, the measured breakdown voltage of the fabricated p-i-n diode using the Hybrid-JTE is as high as 5450 V, which is close (~99%) of the ideal parallel plane p-n junction. As a result, measured breakdown voltages from randomly chosen 32 p-i-n diodes across the wafer show very tight distribution: 29 diodes provide breakdown voltages higher than 5000 V at 100 μA.

42 ENGINEERING↗

1 kV GaN-on-Si Quasi-Vertical Schottky Rectifier

Here, this work demonstrates quasi-vertical GaN Schottky barrier diodes (SBDs) on 6-inch Si substrate with a breakdown voltage (BV) over 1 kV, the highest BV reported in vertical GaN-on-Si SBDs to date. The deep mesa inherently in quasi-vertical devices is leveraged to form a self-aligned edge termination, and the mesa sidewall is covered by the p-type nickel oxide (NiO) as a reduced surface field (RESURF) structure. This novel termination enables a parallel-plane junction electric field of 2.8 MV/cm. The device also shows low turn-on voltage of 0.5 V, and low specific on-resistance of 1.1 mΩ∙ cm 2 . Moreover, the device exhibits excellent overvoltage robustness under the continuous 800 V stress in the unclamped inductive switching test. These results show the good promise of the low-cost vertical GaN-on-Si power diodes.

42 ENGINEERING↗

Robust Avalanche (1.5 kV, 2 kA/cm²) in Vertical GaN Diodes on Patterned Sapphire Substrate

The lack of avalanche capability is a key limitation of current lateral GaN devices. Despite the report of avalanche in vertical GaN-on-GaN devices, the high wafer cost hinders device commercialization. Here, in this work, we demonstrate a circuit-level avalanche in vertical GaN diodes on low-cost patterned sapphire substrate (PSS), with the avalanche voltage (1.57 kV) and avalanche current density (>2 kA/cm 2 ) both being the highest reported in GaN devices on foreign substrates. The PSS enables a lower dislocation density than conventional sapphire substrate and is employed in high-voltage GaN devices for the first time. The avalanche voltage in the circuit test reaches 98% of the parallel-plane limit, further affirming that near-ideal avalanche breakdown can be realized on GaN devices on foreign substrates. These results show the promise of the GaN-on-PSS platform for low-cost, robust power devices.

42 ENGINEERING↗

Implanted Guard Ring Edge Termination With Avalanche Capability for Vertical GaN Devices

Edge termination is the key building block in power devices to enable near-ideal, avalanche breakdown voltage (BV). Here, this work presents the design, fabrication, and physics of a GaN guard ring (GR) edge termination formed by selective-area nitrogen implantation through an epitaxial p-GaN layer. The fabrication of this termination only includes a single implantation step that does not require precise control of implant depth, rendering a large process latitude. The selective-area implantation produces p-GaN rings that are separated by the implanted, semi-insulating regions. The number and spacing of the p-type rings are found to determine the BV of the vertical GaN p-n diode. The 16-ring structure enables a BV of 1800 V, being 88% of the theoretical 1-D parallel-plane limit. Avalanche characteristics are observed in devices with a large variety of GR designs. Finally, we present a comprehensive survey on the efficiency, fabrication complexity, real estate, and avalanche capability of various edge termination techniques that have been reported in vertical GaN devices. The high efficiency (among the highest reported in avalanche-capable GaN terminations), simple and robust fabrication process, and uniform avalanche capability make this implanted GR a promising edge termination for high-voltage GaN devices.

42 ENGINEERING↗

Impact of pellet preparation on reflectance measurements of ammonium sulfate by single-angle reflectance spectroscopy

The optical constants, n and k, are required to model the reflection, refraction and transmission of light at the first surface interface of a material, as well as its propagation through the material; here n corresponds to the real component and k the imaginary component of the refractive index. Several different spectroscopic methods have been used to determine the n and k values for different materials, including single angle reflectance spectroscopy and ellipsometry. The single-angle reflectance method quantitatively records the specular reflectance R(v) from a plane parallel face of the material and uses the Kramers-Kronig transform to extract the n and k values. For most compounds, however, it is difficult to obtain a single crystal or high-quality window of sufficient planarity and of the appropriate dimensions (several mm) to make the measurement. For this reason, we further investigate the use of pressed pellets of neat powdered substances to measure optical constants of these substances using the single-angle reflectance method. We have found that surface roughness can significantly influence the measured quantitative reflectance spectrum R(v) and, consequently, the derived n and k parameters. A collaborative study between Defence Research and Development Canada (DRDC) - Valcartier Research Center and Pacific Northwest National Laboratory (PNNL) has been carried out using different pellets of neat ammonium sulfate [(NH4)2SO4] to show how parameters such as the relative fraction of particle sizes for the component powder along with the grinding process of the pure compound all can affect the reflectance spectrum used to derive the optical constants. All pressed pellets were characterized by single-angle reflectance spectroscopy.

Diaz, Emmanuela↗

Iso-uncertainty control in an experimental fluoroscopy system

Purpose: X-ray fluoroscopy remains an important imaging modality in a number of image-guided procedures due to its real-time nature and excellent spatial detail. However, the radiation dose delivered raises concerns about its use particularly in lengthy treatment procedures (>0.5 h). The authors have previously presented an algorithm that employs feedback of geometric uncertainty to control dose while maintaining a desired targeting uncertainty during fluoroscopic tracking of fiducials. The method was tested using simulations of motion against controlled noise fields. In this paper, the authors embody the previously reported method in a physical prototype and present changes to the controller required to function in a practical setting. Methods: The metric for feedback used in this study is based on the trace of the covariance of the state of the system, tr(C). The state is defined here as the 2D location of a fiducial on a plane parallel to the detector. A relationship between this metric and the tube current is first developed empirically. This relationship is extended to create a manifold that incorporates a latent variable representing the estimated background attenuation. The manifold is then used within the controller to dynamically adjust the tube current and maintain a specified targeting uncertainty. To evaluate the performance of the proposed method, an acrylic sphere (1.6 mm in diameter) was tracked at tube currents ranging from 0.5 to 0.9 mA (0.033 s) at a fixed energy of 80 kVp. The images were acquired on a Varian Paxscan 4030A (2048 × 1536 pixels, ∼100 cm source-to-axis distance, ∼160 cm source-to-detector distance). The sphere was tracked using a particle filter under two background conditions: (1) uniform sheets of acrylic and (2) an acrylic wedge. The measured tr(C) was used in conjunction with a learned manifold to modulate the tube current in order to maintain a specified uncertainty as the sphere traversed regions of varying thickness corresponding to the acrylic sheets in the background. Results: With feedback engaged, the tracking error was found to correlate well with the specified targeting uncertainty. Tracking of the fiducial was found to be robust to changes in the attenuation presented by the varying background conditions. For a desired uncertainty of 5.0 mm, comparison of the feedback framework with a comparable system employing fixed exposure demonstrated dose savings of 29%. Conclusions: This work presents a relation between a state descriptor, tr(C), the x-ray tube current used, and an estimate of the background attenuation. This relation is leveraged to modulate the tube current in order to maintain a desired geometric uncertainty during fluoroscopy. The authors’ work demonstrates the use of the method in a real x-ray fluoroscopy system with physical motion against varying backgrounds. The method offers potential savings in imaging dose to patients and staff while maintaining tracking uncertainty during fluoroscopy-guided treatment procedures.

60 APPLIED LIFE SCIENCES↗

Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

SU-E-T-198: Comparison Between a PTW MicroDiamond Dosimeter and a Markus Chamber in a 62 MeV/n Carbon Ion Beam

Purpose: To investigate the linear energy transfer (LET) dependence of a PTW Freiburg microDiamond dosimeter, we compared its response to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Methods: The response of both detectors has been studied as a function of depth in graphite by adding or removing graphite plates in front of the detectors. To account for fluctuations of the beam, we used two setups with different monitor chambers. The depth of the effective point of measurement of both detectors has been converted into a graphite equivalent depth using ICRU Report 73 data. As recommended by IAEA TRS-398, the response of the Markus chamber has been corrected for temperature, pressure, polarity effects and ion recombination. The latter required an additional experiment; to quantify the effect of volume recombination and initial recombination, measurements have been performed at different voltages and different dose rates. Results: As expected, the dominant process leading to ion recombination for carbon ion beam is the initial recombination. At the entrance, the ion recombination correction equals 1.1% and the value is approximately constant in the plateau region. Due to the increase of the LET in the Bragg peak region, we observe a strong increase of the ion recombination correction, up to 6.1% at the distal edge. Comparison between the microDiamond response and the Markus chamber response shows good agreement in the plateau region. However, we observe a 13.6% under response of the microDiamond in the Bragg peak. Conclusion: Increasing between 1% and 6%, the depth dependent ion recombination correction has to be applied to the Markus response. The comparison between the microDiamond and the Markus chamber indicates that there is an under-response of the microDiamond in the vicinity of the Bragg peak due to the increased LET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high-energy proton beam. Jefferson Sorriaux is financed by the Walloon Region under the convention 1217662. Jefferson Sorriaux is sponsored by a public-private partnership IBA - Walloon Region.

60 APPLIED LIFE SCIENCES↗

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗