Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fast and flexible analysis of direct dark matter search data with machine learning

We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. Furthermore, this technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of Thin III-V Solar Cells on Ni Films using Electroless Ni Deposition

Thin solar cells are inherently fragile, and must be properly supported during fabrication, handling and use. Metal films can provide this support, but accomplishing this can be challenging. Here we describe a method for fabricating thin III-V solar cells on Ni films, using electroless deposition to deposit a thick (10-50 um) Ni film onto the bottom of an inverted III-V solar cell prior to substrate removal. Cells have been fabricated on both rigid and flexible supports with no loss of performance when compared to cells processed using standard inverted-cell processing.

14 SOLAR ENERGY↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

NRC Reactor Operating Experience Analysis and Trend Summary: 2020 Update

This report presents a summary of the reliability and frequency trends identified in the 2020 update reports for component performance study, loss of offsite power analysis, initiating events analysis, and system study provided on the Nuclear Regulatory Commission (NRC) Reactor Operating Experience Results and Databases web site (https://nrcoe.inl.gov/).

99 GENERAL AND MISCELLANEOUS↗

Benchmarking the AirSquared All-Metal Scroll Pump Against the Normetex 15 - Preliminary report

Tritium operations require specialized equipment for material compatibility, safety, and waste considerations. Non-metallic pump materials (polymer, oil, or grease) on a tritium-wetted surface can absorb tritium and/or undergo isotope exchange between tritium and more common protium, creating tritiated compounds that can result in material property modification via beta-radiolysis, inventory loss, reduced performance and special waste considerations, all of which increase the operating cost for a facility. Vacuum pumps move gas via a pressure differential between volumes of an operation. Several types of all-metal vacuum pumps exist for this application including metal bellows, diaphragm and scroll pumps. A metal bellows pump incorporates only metal components at the wetted surfaces. The common metal bellows pump employed in tritium facilities, the MB601 (Senior Metal Bellows, Sharon, PA, USA) creates a gas-motive force with a vacuum pressure between 30-40 torr. These pumps can efficiently move gas from one process step to another, as long as sub-30 torr pressures are not required. However, for higher vacuum demand, an all-metal scroll pump can be used with the bellows pump serving as a “backing” pump. This configuration typically provides an achievable vacuum of less than 20 mTorr. All-metal scroll pumps are a technology uniquely applicable to tritium gas handling. The industry standard all-metal scroll pump for glovebox-scale tritium operations is the Normetex 15 m 3 /hr, typically referred to as the Normetex 15 (Normetex Pompes, Pont Audemer, France). However, the final Normetex pumps were manufactured in 2012, rendering them no longer available. Eumeca SaRL (formerly Normetex) has developed and is marketing a scroll pump based on the design of the Normetex 15. A US company, AirSquared (Broomfield, Colorado), has developed and is marketing a potential alternative to the Normetex 15. The Gas Transfer Systems group (Q-7) of the Los Alamos National Laboratory (LANL) procured serial number 0001 of the AirSquared All Metal Vacuum Scroll pump model number V16H034A-C01 in 2019. The LANL Hydrogen Processing Laboratory (HPL) has been evaluating the performance of the pump compared to a Normetex pump as a potential replacement in tritium and fusion facilities requiring this type of pump.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

Identifying impacts of process, precursors, and defects in metal halide perovskite solar cells

With efficiencies of halide perovskite solar cells stagnating over the last few years at values above 25% and approaching thermodynamic limits, focus must shift to ensuring stability of these devices over the long term. The overarching goal of this project was to understand the root causes of instability in halide perovskite solar cells. Our approach was rooted in fundamental scientific pursuits, determining at the molecular level those processes responsible for degradation of the metal halide perovskite system, either in the precursor ink, or in the solid state. We then used this understanding to show that degradation leads to midgap states in halide perovskite semiconductors, explaining loss in performance; also, this in-depth understanding allowed us to develop specifically targeted solutions to prevent these degradation mechanisms. These include guidance about amines in perovskite inks, solvents to use (and not to use), and impacts of Cs incorporation to perovskite inks and solids. Finally, we achieved our end-of-project goal and demonstrated an effective lifetime of a halide perovskite solar cell of 5000 h, including measurement of devices over 3000 h, amongst the longest in the field. Overall, this project has considerably pushed forward the science of perovskite degradation and sets examples and groundwork for future studies to enable halide perovskite solar cells to be a successful solar energy conversion technology.

14 SOLAR ENERGY↗

NRC Reactor Operating Experience Analysis and Trend Summary: 2022 Update

This report presents a summary of the Nuclear Regulatory Commission (NRC) reactor operating experience analyses with data through 2022 as well as the reliability and frequency trends identified in the 2022 update reports for component performance study, loss of offsite power analysis, initiating events analysis, and system study provided on the NRC Reactor Operating Experience Results and Databases website (https://nrcoe.inl.gov/).

99 GENERAL AND MISCELLANEOUS↗

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Moderator Test Station at ORNL

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a reimagined FTS and the current STS concept are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the neutron beams so produced. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility. We propose a Moderator Test Station (MTS) at the SNS with which we will verify such performance gains and test new moderator concepts. These concepts include both high-brightness and large-volume parahydrogen moderators, as well as moderators with tailored ortho:para hydrogen levels, heterogeneous moderator concepts such as the convoluted moderator or pelletized moderators, and moderators made of materials like ammonia, ethane, and oxygen clathrates, which have not been widely tested let alone deployed at neutron source facilities.

42 ENGINEERING↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

The performance evaluation of direct detection electron energy-loss spectroscopy at 200 kV and 80 kV accelerating voltages

Direct electron detectors (DeDs) have been widely used for imaging studies because of their higher beam sensitivity, lower noise, improved pixel resolution, etc. However, there have been limited studies related to the performance in spectroscopic applications for the direct electron detection. Hereby, taking the advantage of the DeD installed on a high-performance electron energy-loss spectrometer, we systematically studied the performance of a DeD (Gatan's K2 IS) fitted on an aberration-corrected transmission electron microscope (TEM) equipped with an electron monochromator. Using SrTiO3 as the model system, the point spread function in the zero-loss region of the spectrum and the performance for core loss spectroscopy have been investigated under both 200 kV and 80 kV operating conditions. We demonstrate that the K2 detector can achieve an overall better performance at 200 kV than a charge coupled device (CCD) detector. At 80 kV, the K2 DeD is still better than a CCD, except for the relative broad tails of the zero-loss peak. The signal-to-noise ratio is very close for DeD and CCD under 80 kV. Based on our data obtained at different operating voltages, it is clear that DeD will benefit the microscopy community and boost the development of cutting-edge materials science studies by pushing the frontiers in electron energy-loss spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Management for a Novel Non-Heavy Rare-Earth Interior Permanent Magnet Machine

The work presents a thermal management solution for a novel non-heavy rare-earth permanent magnet machine being developed at Oak Ridge National Laboratory. The motor has been designed to minimize losses while maximizing performance for a range of speeds and power ratings. The novel motor design reduces rare-earth magnet usage, thereby avoiding supply chain issues. The motor component heat losses are established for operating windows and desired performance. These heat losses, along with windage losses, are being used to develop cooling solutions for different components of this machine. A novel thermal management solution for stators and rotors has been developed, and progress is presented in this paper. The stator cooling is achieved with the help of water-ethylene glycol flowing over the finned aluminum stator jacket, and rotor cooling with automatic transmission fluid passing through novel channels designed in the rotor laminations. The attempt is to establish effective cooling of the stator winding, laminations, and rotor magnets. A 3D conjugate heat transfer model has been developed for overall thermal analysis to establish a down- selected thermal management solution for the machine. The model, in addition to estimated component heat losses, includes windage losses and its impact on rotor and stator cooling. Overall, the work presents a workable thermal solution for the interior permanent magnet machine with potential for further improvements. Future work will involve establishing end winding and refinement of other end parts of the machine with the aim of establishing a robust thermal management solution. The work will also focus on different shapes (e.g., round, non-round, presence of wedges) of rotor-stator gaps and investigate windage losses and their impact on thermal management for higher rotational speeds for the machine.

30 DIRECT ENERGY CONVERSION↗

Highly Active and Stable Single Atom Rh 1 /CeO 2 Catalyst for CO Oxidation during Redox Cycling

We report a single atom Rh 1 /CeO 2 catalyst prepared by the high temperature (800 °C) atom trapping (AT) method which is stable under both oxidative and reductive conditions. Infrared spectroscopic and electron microscopy characterization revealed the presence of exclusively ionic Rh species. These ionic Rh species are stable even under reducing conditions (CO at 300 °C) due to the strong interaction between Rh and CeO 2 achieved by the AT method, leading to high and reproducible CO oxidation activity regardless of whether the catalyst is reduced or oxidized. In contrast, ionic Rh species in catalysts synthesized by a conventional impregnation approach (e. g., calcined at 350 °C) can be readily reduced to form Rh nanoclusters/nanoparticles, which are easily oxidized under oxidative conditions, leading to loss of catalytic performance. The single atom Rh 1 /CeO 2 catalysts synthesized by the AT method do not exhibit changes during redox cycling hence are promising catalysts for emission control where redox cycling is encountered, and severe oxidation (fuel cut) leads to loss of performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of solar leasing for low- and middle-income customers in Connecticut

Policymakers are increasingly interested in expanding access to rooftop photovoltaic systems. This study analyzes the financial performance of a Connecticut Green Bank (CGB) solar leasing program, run in partnership with PosiGen, that targets low- and moderate-income customers. We show that this program has successfully reached underserved customers and has reasonable repayment rates given the credit characteristics of the participants. The CGB/PosiGen program reaches many more underserved customers than other PV financing programs in Connecticut.For example, the majority of CGB/PosiGen participants (58%) live in census tracts that have a median income of less than 80% of the area median income (AMI). In contrast, only 9% of participants in the other CGB solar financing programs live in these census tracts. Furthermore, the majority of CGB/PosiGen participants (56%) have FICO scores that would generally be considered non-prime (<670), whereas only 2% of participants in the other programs have similarly low scores. Credit, not income, is the primary factor that explains participants’ financial performance. Overall, we find that delinquency and annualized losses are higher for PosiGen (2.3% and 0.9%) than for other CGB programs (1.4% and 0.1%). Across the CGB programs, lower credit scores are associated with higher rates of delinquency and loss. Therefore, participants’ lower credit scores explain much of the program’s higher rates of delinquency and annualized losses. PosiGen leases perform competitively with market-rate solar and non-solar leases and loans. When compared to securities backed by market-rate PV loans and leases with similar amounts of seasoning, we find that the PosiGen leases have higher delinquency rates but comparable gross loss rates. The similarity in losses is notable given that loss rates for PosiGen leases were higher than those of the other CGB leases and loans. Rather than the PosiGen leases having high loss rates, other CGB leases and loans have unusually low loss rates. We also compare PosiGen to non-solar benchmarks, including indices of auto and consumer loans. We find that the PosiGen leases have significantly less delinquency than non-prime auto loans and have performance comparable to many consumer loans. The U.S. Department of Energy’s Solar Energy Technologies Office supported this research.

14 SOLAR ENERGY↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗