Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES↗

Analysis of human performance differences between students and operators when using the Rancor Microworld simulator

Here, from within the umbrella of the Simplified Human Error Experimental Program (SHEEP) framework, this paper analyzes human performance differences between professional and student operators when using a simplified simulator (i.e., Rancor Microworld). This paper represents a crucial step in understanding the fidelity of the simplified simulators and student operators within the SHEEP study. This paper explores a randomized factorial experimental design that features two independent variables: participant type and event class. Six human performance measurements are considered in the experiment. The experiment is conducted using 20 professional reactor operators employed at actual nuclear power plants (NPPs), along with 20 trained students. The experimental data are analyzed via statistical analysis methods. Finally, this paper examines the differences in human performance between actual operators and students when using Rancor Microworld.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurements of beam backgrounds in SuperKEKB Phase 2

The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgrounds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle II experiment. We report on the first background measurements performed after roll-in of the Belle II detector, utilizing both the BEAST II system of dedicated background sensors and the Belle II detector itself. Here we also report on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions from synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds originating from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV electron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds forward and conclude it is safe to proceed to installation of the Belle II vertex detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation spectrum and low-temperature magnetism in the disordered defect-fluorite Ho2⁢Zr2⁢O7

In this work, we report on the thermomagnetic characterization and crystalline-electric field (CEF) energy scheme of the disordered defect-fluorite Ho2⁢Zr2⁢O7. This structural phase is distinguished by the coexistence of magnetic frustration and extensive disorder, with Ho3+ and Zr4+ sharing randomly the same 4⁢𝑎 site with even 50% occupancy, and an average 1/8 oxygen vacancy per unit cell. AC magnetic susceptibility measurements performed on powder samples down to 0.5 K revealed signs of slowing spin dynamics without glassy behavior, including a frequency dependent peak at ∼1K. Yet, no evidence for long-range magnetic order is found down to 200 mK in the specific heat. Inelastic neutron scattering measurements show a weak, low-lying CEF excitation around 2 meV, accompanied by a broad level centered at 60 meV. To fit our observations, we propose an approach to account for structural disorder in the crystal-field splitting of the non-Kramers Ho3+. Our model provides an explanation to the broadening of the high-energy, single-ion excitations and suggests that the zirconate ground-state wavefunction has zero magnetic moment. Through the breaking of local symmetry, structural disorder enables the magnetic response observed in Ho2⁢Zr2⁢O7, allowing the mixing of low-lying states at finite temperatures. Finally, we show that this scenario is in good agreement with the bulk properties reported in this work.

Gardner, Jason [ORNL] (ORCID:0000000278234072)↗

Using Neural Architecture Search for Improving Software Flaw Detection in Multimodal Deep Learning Models

Software flaw detection using multimodal deep learning models has been demonstrated as a very competitive approach on benchmark problems. In this work, we demonstrate that even better performance can be achieved using neural architecture search (NAS) combined with multimodal learning models. We adapt a NAS framework aimed at investigating image classification to the problem of software flaw detection and demonstrate improved results on the Juliet Test Suite, a popular benchmarking data set for measuring performance of machine learning models in this problem domain.

97 MATHEMATICS AND COMPUTING↗

Using Neural Architecture Search for Improving Software Flaw Detection in Multimodal Deep Learning Models

Software flaw detection using multimodal deep learning models has been demonstrated as a very competitive approach on benchmark problems. In this work, we demonstrate that even better performance can be achieved using neural architecture search (NAS) combined with multimodal learning models. We adapt a NAS framework aimed at investigating image classification to the problem of software flaw detection and demonstrate improved results on the Juliet Test Suite, a popular benchmarking data set for measuring performance of machine learning models in this problem domain.

97 MATHEMATICS AND COMPUTING↗

Annual Summary Report (FY 2025) Performance Assessment for the Integrated Disposal Facility

The purpose of this Annual Summary Report (ASR) for fiscal year (FY) 2025 is to evaluate the continued adequacy of the Integrated Disposal Facility (IDF) Performance Assessment (PA) and Disposal Authorization Statement (DAS). This report consolidates relevant monitoring data, modeling analyses, and regulatory reviews to demonstrate a reasonable expectation that the PA objectives and performance measures will be met, as required under DOE O 435.1, Radioactive Waste Management. The ASR follows the guidance in DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation, which provides a framework for maintaining the validity of the DAS through periodic assessment of facility performance and compliance with waste disposal requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combination of Measurements of the Top Quark Mass from Data Collected by the ATLAS and CMS Experiments at s = 7 and 8 TeV

A combination of fifteen top quark mass measurements performed by the ATLAS and CMS experiments at the LHC is presented. The datasets used correspond to an integrated luminosity of up to 5 and 20 fb − 1 of proton-proton collisions at center-of-mass energies of 7 and 8 TeV, respectively. The combination includes measurements in top quark pair events that exploit both the semileptonic and hadronic decays of the top quark, and a measurement using events enriched in single top quark production via the electroweak t channel. The combination accounts for the correlations between measurements and achieves an improvement in the total uncertainty of 31% relative to the most precise input measurement. The result is m t = 172.52 ± 0.14 ( stat ) ± 0.30 ( syst ) GeV , with a total uncertainty of 0.33 GeV. © 2024 CERN, for the CMS and ATLASs Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Dynamics Studies at the PIP-II Injector Test Facility

A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised of a 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1- MeV CW RFQ, followed by a 10-m Medium Energy Beam Transport (MEBT), 2 cryomodules accelerating the beam to 16 MeV and a High-Energy Beam Transport (HEBT) bringing the beam to a dump. This paper presents beam dynamics - related measurements performed at PIP2IT such as the Twiss parameters with Allison scanners, beam envelopes along the injector, and transverse and longitudinal rms emittance reconstruction. These measurements are compared with predictions from the beam dynamics code Tracewin.

43 PARTICLE ACCELERATORS↗

Virtual Reality for Shoot/No-Shoot Decision Training in Law Enforcement: A Literature Review and Research Agenda

Virtual reality (VR) can materially improve “shoot / no-shoot” (SNS) training by giving officers realistic, repeatable practice making high-stakes decisions under pressure. Traditional tools—live-fire ranges and video simulators—build basics, but they cannot adapt to each officer in real time or fully mirror the complexity of the field. VR closes that gap by creating immersive scenarios that are safer, more flexible, easier to scale across units, and able to capture objective performance data. SNS decisions are not just about marksmanship; they rely on perception, judgment, memory, and the ability to hold fire when a threat is uncertain. Effective training therefore needs realism, decision complexity, and branching outcomes that reflect the true consequences of choices. These elements strengthen recognition of hostile intent while reducing false positives and building the self-control required in ambiguous situations. VR brings specific advantages: dynamic environments, full-body interaction, and the ability to measure performance with precision—enabling targeted feedback and better transfer of learning to the street. At the same time, responsible deployment must address scenario quality (credible environments and behaviors), lawful decision models, and user wellbeing (appropriate stress levels, comfort, and safety). Sandia’s VIPER Lab is positioned to lead this work. The team combines human-performance science, AI/ML, and VR/AR development with a deep equipment bench (e.g., omnidirectional treadmill, eye-tracking, haptics, multiple HMDs). This ecosystem supports building and validating next-generation SNS training that is immersive, measurable, and trustworthy. Bottom line: Investment in VR-enabled SNS training that blends evidence-based design with careful validation and legal safeguards is expected to pay off in safer, more consistent decision-making and improved community trust, delivered through training that is practical to deploy at scale.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A next generation ultra short pulse reflectometry (USPR) diagnostic

Ultrashort Pulse Reflectometry (USPR) is a plasma diagnostic technique involving the propagation and reflection of ultrashort duration (~few ns) chirps. The reflected packets pass through a multichannel filter with time-of-flight measurements performed on each of the filtered packets. A next generation USPR system is under development, spanning 28–75 GHz, for use on compact, short duration, magnetically confined fusion devices. This system presents a dramatic increase in performance compared with an earlier USPR system employed on the LLNL Sustained Spheromak Physics Experiment device more than a decade ago. The new system replaces upconverting mixers with higher power active multiplier chains to generate mm-wave transmitter chirps, with custom time-of-flight electronics reducing the time per measurement by a factor of 3X. Finally, the system is equipped with a field programmable gate array for data acquisition and analysis.

47 OTHER INSTRUMENTATION↗

Combination of measurements of the top quark mass from data collected by the ATLAS and CMS experiments at $\sqrt{s}=7$ and $8~\mathrm{TeV}$

A combination of fifteen top quark mass measurements performed by the ATLAS and CMS experiments at the LHC is presented. The data sets used correspond to an integrated luminosity of up to 5 and $20~\mathrm{fb}^{-1}$ of proton-proton collisions at center-of-mass energies of 7 and $8~\mathrm{TeV}$, respectively. The combination includes measurements in top-quark pair events that exploit both the semi-leptonic and hadronic decays of the top quark, and a measurement using events enriched in single top quark production via the electroweak $t$-channel. The combination yields $m_{\mathrm{t}} = 172.52 \pm 0.14~(\mathrm{stat}) \pm 0.30~(\mathrm{syst}) ~\mathrm{GeV}$, with a total uncertainty of $0.33~\mathrm{GeV}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of neutron emission and neutron energy spectrum calculations on a Mega Ampere Spherical Tokamak with directional relativistic spectrum simulator

The recently developed directional relativistic spectrum simulator (DRESS) code has been validated for the first time against numerical calculations and experimental measurements performed on the Mega Ampere Spherical Tokamak . In this validation, the neutron emissivities and rates computed by DRESS are benchmarked against TRANSP/NUBEAM predictions while the neutron energy spectra provided by DRESS taking as input TRANSP/NUBEAM and ASCOT/BBNBI in Gyro-Orbit mode fast ion distributions are validated against proton pulse height spectra measured by the neutron flux monitor. Finally, excellent agreement was found between DRESS and TRANSP/NUBEAM predictions of local and total neutron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oxygen Reduction at PtNi Alloys in Direct Methanol Fuel Cells—Electrode Development and Characterization

Catalyst layers made from novel catalysts must be fabricated in a way that the catalyst can function to its full potential. To characterize a PtNi alloy catalyst for use in the cathode of Direct Methanol Fuel Cells (DMFCs), the effects of the manufacturing technique, ink composition, layer composition, and catalyst loading were here studied in order to reach the maximum performance potential of the catalyst. For a more detailed understanding, beyond the DMFCs performance measurements, we look at the electrochemically active surface area of the catalyst and charge-transfer resistance, as well as the layer quality and ink properties, and relate them to the aspects stated above. As a result, we make catalyst layers with optimized parameters by ultrasonic spray coating that shows the high performance of the catalyst even when containing less Pt than commercial products. Using this approach, we can adjust the catalyst layers to the requirements of DMFCs, hydrogen fuel cells, or polymer electrolyte membrane electrolysis cells.

30 DIRECT ENERGY CONVERSION↗

Three phase spectral interferometry for recording high dynamic range optical waveforms with <1 ps resolution over >2 ns records applied to closed-loop pulse shaping

Herein we demonstrate, to our knowledge, a novel spectral interferometry technique that simultaneously captures three spectral interferograms of a signal waveform with a reference pulse. The measured performance is robust to nonidealities and ambient drifts by implementing a precisely calibrated 3 × 3 polarization maintaining (PM) splitter that provides three phase shift differences nominally spaced 120° apart. The system can achieve long record length by implementing three, high resolution, virtually imaged phase array (VIPA) spectrometers. Here, we experimentally implement this technique and demonstrate the measurement of waveforms with >2ns of record while maintaining <1ps resolution.

42 ENGINEERING↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗