Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, • and a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Multi-plane light conversion device↗

Insertion Loss of a Multi-Plane Light Conversion Device with Few Mode Fiber Outputs Under Atmospheric Conditions

A key challenge of photon counting optical communication is delivering light with atmospherically distorted wavefronts from the telescope to detectors efficiently. When using fiber coupled single photon detectors, the efficiency of the transmittance is constrained by the modes supported by the fiber. The number of modes supported by a fiber depends on the size of the core. The larger the core, the more modes supported. However, commercial off the shelf superconducting nanowire single photon detectors (SNSPDs) are currently limited in area, which limits the core size of the fibers that can efficiently couple to the detectors. To increase the amount of light that can be delivered to the detectors, NASA Glenn Research Center is considering many different fiber/detector architectures. This paper compares insertion loss of the fiber device for two different architectures: • a multi-plane light conversion device to split the light from a 30 µm core diameter fiber into 7 separate, 15 µm core diameter few-mode fibers butt-coupled to 7 single-element SNSPDs, and • a 30 µm core diameter multimode fiber butt-coupled to a 16 multi-element, SNSPD array. The measured insertion loss for each fiber device under emulated atmospheric conditions with D/r0 between 2 and 30 is presented. The multi-plane light conversion device shows a consistent ~1 dB loss more than the multimode fiber. Also presented is the measured uneven power splitting of the multiplane light conversion device, especially at lower D/r0. How this uneven power splitting contributes to system loss called blocking loss is discussed.

Fiber↗

Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.

Stevenson, T. R.↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Influence of Coronal Abundance Variations

The PI of this project was Jeff Scargle of NASA/Ames. Co-I's were Alma Connors of Eureka Scientific/Wellesley, and myself. Part of the work was subcontracted to Eureka Scientific via SAO, with Vinay Kashyap as PI. This project was originally assigned grant number NCC2-1206, and was later changed to NCC2-1350 for administrative reasons. The goal of the project was to obtain, derive, and develop statistical and data analysis tools that would be of use in the analyses of high-resolution, high-sensitivity data that are becoming available with new instruments. This is envisioned as a cross-disciplinary effort with a number of "collaborators" including some at SA0 (Aneta Siemiginowska, Peter Freeman) and at the Harvard Statistics department (David van Dyk, Rostislav Protassov, Xiao-li Meng, Epaminondas Sourlas, et al). We have developed a new tool to reliably measure the metallicities of thermal plasma. It is unfeasible to obtain high-resolution grating spectra for most stars, and one must make the best possible determination based on lower-resolution, CCD-type spectra. It has been noticed that most analyses of such spectra have resulted in measured metallicities that were significantly lower than when compared with analyses of high- resolution grating data where available (see, e.g., Brickhouse et al., 2000, ApJ 530,387). Such results have led to the proposal of the existence of so-called Metal Abundance Deficient, or "MAD" stars (e.g., Drake, J.J., 1996, Cool Stars 9, ASP Conf.Ser. 109, 203). We however find that much of these analyses may be systematically underestimating the metallicities, and using a newly developed method to correctly treat the low-counts regime at the high-energy tail of the stellar spectra (van Dyk et al. 2001, ApJ 548,224), have found that the metallicities of these stars are generally comparable to their photospheric values. The results were reported at the AAS (Sourlas, Yu, van Dyk, Kashyap, and Drake, 2000, BAAS 196, v32, #54.02), and at the conference on Statistical Challenges in Modem Astronomy (Sourlas, van Dyk, Kashyap, Drake, and Pease, 2003, SCMA 111, Eds. E.D.Feigelson, G.J.Babu, New York:Springer, p489-490). We also described the limitations of one of the most egregiously misused and misapplied statistical tests in astrophysical literature, the F-test for verifying model components (Protassov, van Dyk, Connors, Kashyap, and Siemiginowska, 2002, ApJ, 571,545). Indeed, a search through the ApJ archives turned up 170 papers in the 5 previous years that used the F-test explicitly in some form or the other, and with the vast majority of them not using it correctly! Indeed, looking at just 4 issues of the ApJ in 2001, we found 13 instances of its use, of which nine were demonstrably incorrect. Clearly, it is difficult to understate the importance of this issue. We also worked on speeding up Bayes Blocks and Sparse Bayes Blocks algorithms to make them more tractable for large searches. We also supported staistics students and postdocs in both explicit physics- model-based (spectra with tens of thousands of atomic lines) and "model-free" -- i.e. non-parametric or semi-parametric -- algorithms. Work on using more of the latter is just beginning; while using multi-scale methods for Poisson imaging has come to hition. In fact, "An Image Restoration Technique with Error Estimates", by D. Esch, A. Connors, M. Karovska, and D. van Dyk, was published by ApJ (Esch et a1.2004, ApJ, 610, 1213). The code has been delivered to M. Karovska for CXC; and is available for beta-testing upon request. The other large project we worked on was on the self-consistent modeling of logN-logs curves in the Poisson limit. logN-logs curves are a fundamental tool in the study of source populations, luminosity functions, and cosmological parameters. However, their determination is hampered by statistical effects such as the Eddington bias, incompleteness due to detection efficiency, faint source flux fluctuations, etc. We have develed a new and powerful method using the full Poisson machinery that allows us to model the logN-logs distribution of X-ray sources in a self-consistent manner. Because we properly account for all the above statistical effects, our modeling is valid over the full range of the data, and not just for strong sources, as is normally done. Using a Bayesian approach and modeling the fluxes with known functional forms such as simple or broken power-laws, and conditioning the expected photon counts on the fluxes, the background contamination, effective area, detector vignetting, and detection probability, we can delve deeply into the low counts regime and extend the usefulness of medium sensitivity surveys such as ChAMP by orders of magnitude. The built-in flexibility of the algorithm also allows a simultaneous analysis of multiple datasets. We have applied this analysis to a set a Chandra observations (Sourlas, Kashyap, Zezas, van Dyk, 2004, HEAD #8, #16.32)

Scargle, Jeffrey D.↗

Analysis of Burst Observations by GLAST's LAT Detector

Analyzing data from GLAST's Large Area Telescope (LAT) will require sophisticated techniques. The PSF and effective area are functions of both photon energy and the position in the field-of-view. During most of the mission the observatory will survey the sky continuously and thus the LAT will detect each count from a source at a different detector orientation; each count requires its own response function! The likelihood as a function of celestial position and photon energy will be the foundation of the standard analysis techniques. However the 20 MeV-300 GeV emission at the time of the approx.100 keV burst emission (timescale of approx.10 s) can be isolated and analyzed because essentially no non-burst counts are expected within a PSF radius of the burst location during the burst. Both binned and unbinned (in energy) spectral fitting will be possible. Longer timescale afterglow emission will require the likelihood analysis that will be used for persistent sources.

Band, David L.↗

Some atmospheric scattering considerations relevant to BATSE: A model calculation

The orbiting Burst and Transient Source Experiement (BATSE) will locate gamma ray burst sources by analysis of the relative numbers of photons coming directly from a source and entering its prescribed array of detectors. In order to accurately locate burst sources it is thus necessary to identify and correct for any counts contributed by events other than direct entry by a mainstream photon. An effort is described which estimates the photon numbers which might be scattered into the BATSE detectors from interactions with the Earth atmosphere. A model was developed which yielded analytical expressions for single-scatter photon contributions in terms of source and satellite locations.

Young, John H.↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

The Burst and Transient Source Experiment Earth Occultation Technique

An Earth orbiting detector sensitive to gamma-ray photons will see step-like occultation features in its count rate when a gamma-ray point source crosses the Earth's limb. This is due to the change in atmospheric attenuation of the gamma rays along the line of sight. In an uncollimated detector, these occultation features can be used to locate and monitor astrophysical sources provided their signals can be individually separated from the detector background. We show that the Earth occultation technique applied to the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is a viable and flexible all-sky monitor in the low-energy gamma-ray and hard X-ray energy range (20 keV-1 MeV). The method is an alternative to more sophisticated photon imaging devices for astronomy and can serve well as a cost-effective science capability for monitoring the high energy sky. Here we describe the Earth occultation technique for locating new sources and for measuring source intensity and spectra without the use of complex background models. Examples of transform imaging, step searches, spectra, and light curves are presented. Systematic uncertainties due to source confusion, detector response, and contamination from rapid background fluctuations are discussed and analyzed for their effect on intensity measurements. A sky location-dependent average systematic error is derived as a function of Galactic coordinates. The sensitivity of the technique is derived as a function of incident photon energy and also as a function of angle between the source and the normal to the detector entrance window. Occultations of the Crab Nebula by the Moon are used to calibrate Earth occultation flux measurements independent of possible atmospheric scattering effects.

Harmon, B. A.↗

Maturing CCD Photon-Counting Technology for Space Flight

This paper discusses charge blooming and starlight saturation - two potential technical problems - when using an Electron Multiplying Charge Coupled Device (EMCCD) type detector in a high-contrast instrument for imaging exoplanets. These problems especially affect an interferometric type coronagraph - coronagraphs that do not use a mask to physically block starlight in the science channel of the instrument. These problems are presented using images taken with a commercial Princeton Instrument EMCCD camera in the Goddard Space Flight Center's (GSFC), Interferometric Coronagraph facility. In addition, this paper discusses techniques to overcome such problems. This paper also discusses the development and architecture of a Field Programmable Gate Array and Digital-to-Analog Converter based shaped clock controller for a photon-counting EMCCD camera. The discussion contained here will inform high-contrast imaging groups in their work with EMCCD detectors.

Mallik, Udayan↗

Radiative Transfer Through Clouds and Its Applications in Support of the Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2) Mission

The Greenland and Antarctic ice sheets, which contain enough ice to raise sea level by about 7 and 60 m, respectively, are losing mass at an increasing rate. To acquire continuous information of the cryosphere, after the Ice, Cloud, and land Elevation Satellite (ICESat) (2003-2010), NASA is actively planning for the ICESat-2 mission. Both ICESat and ICESat-2 are space-borne lidar altimetry systems. The systems measure the time of flight of the arriving photons that are reflected by the surface to deduce the elevation of the underlying terrain. As one of NASA's top priority missions, ICESat-2 is scheduled to launch in 2016. One of the major science goals of ICESat-2 is to quantify the ice sheet mass balance to determine its contributions to the sea level change and its impacts on ocean circulation (Abdalati et al. 2010). Compared to ICESat, which operates at 40 Hz and records the reflected laser energy as a waveform, the significantly improved ICESat-2 lidar employs a 532 nm micro-pulse photon counting system that operates at a high frequency of 10kHz with single photon detectability (Yang et al. 2012). To achieve its science goals, ICESat-2 requires the ability of detecting the elevation change with an accuracy of 0.2 cm/year over the entire ice sheet. Since every photon emitted by the lidar system will travel through the atmosphere, clouds can certainly affect the flight time of the arriving photons. Forward scattering by cloud particles increases the photon path length, thus resulting in biases in ice sheet elevation measurements known as atmospheric path delay (Duta et al. 2001, Yang et al. 2010, 2011). To ensure the accuracy of ICESat-2 surface elevation measurements, it is critical to understand how clouds would affect the travel time of arriving photons. In this talk, we will first present a framework that simulates the behavior of a space-borne 532 mn micro-pulse photon counting lidar in cloudy and clear atmospheres. To investigate the process of laser propagation through clouds, a 3-D Monte Carlo radiative transfer model is used to simulate the photon path distribution and the Poisson distribution is adopted for the number of photon returns. Since the photon counting system only registers the time of the first arriving photon within the detector "dead time", the retrieved average surface elevation tends to bias towards higher values. This is known as the first photon bias. With the scenarios simulated here, the first photon bias for clear sky is about 6.5 cm. Clouds affect surface altimetry in two ways: (1) cloud attenuation lowers the average number of arriving photons and hence reduces the first photon bias; (2) cloud forward scattering increases the photon path length and makes the surface appear further away from the satellite. Compared to clear sky, the average surface elevation detected by the photon counting system for cloudy sky with optical depth 1.0 is 4.0 to 6.0 cm lower for the simulations conducted. The effect of surface roughness on the accuracy of elevation retrievals will also discussed.

Yang, Yuekui↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Dead-time effects in pulse-counting Digicon detectors

The Hubble Space Telescope's High Resolution Spectrograph employs two pulse-counting Digicon detectors to record UV spectra. At higher measured count rates, the intervals between photon arrivals become comparable to the response time of the electronics, so that not every pulse will be counted; this 'paired pulse' effect causes departures from linearity and must be corrected for during raw data reduction. Attention is given to two analytic equations that quantify the dead-time losses. The less attenuated spectra are noted to be severely distorted by these losses; a comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse-counting characteristics over five decades of input event rates. The present equations and calibration methods should be applicable to all kinds of multichannel pulse-counting detectors.

Ebbets, Dennis C.↗

Signal-to-noise ratios in IUE SWP-LO spectra of chromospheric emission-line sources

The short-wavelength-prime (SWP) detector of the International Ultraviolet Explorer should operate near the photon-counting limit, but the noise levels in flat-field images are several times higher. The exaggerated noise can be traced to the incomplete removal of the pixel-to-pixel granularity of the television frames by the prevailing spectral image processing system. An empirical noise model for the current-epoch photometric linearization strategy and one for a hypothetical processing system that achieves complete flat fielding of the raw images are derived. A formula is then proposed to predict the signal-to-noise ratio in the measured flux of an emission line (possibly superimposed on a smooth continuum) in an IUE low-dispersion (5 A resolution) far-ultraviolet (1150 A-1950 A) spectrum as recorded with the SWP camera. For illustration, the formula is specialized to the important C IV 1549 A feature of F-K stars. The S/N relation permits one to determine sensitivity limits, upper limits in faint exposures, and optimum exposure times.

Ayres, Thomas R.↗

Radiometric Performance Model for AVIRIS

This slide presentation reviews the radiometric performance model for Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This model allows for an estimation of the signal throughput and noise properties of AVIRIS for the components. This understanding can point to areas for improvements of the components.. The signal to noise ratio properties may be estimated. An accurate radiometric performance model is essential for the use of existing instruments and the design of new instruments. Included in the presentation is a design view and a picture of the AVIRIS instrument. There is discussion of the signal, the signal area solid angle product, aspects of area solid angle time, the idealized radiometer photon calculation and noise both instrument read and photon counting noise. Graphs of signal throughput efficiency, input radiance, photons at the detector, signal e-, noise e- and the signal to noise ratio are presented.

imaging spectroscopy↗