Search NASA⌕ Search

SEARCH · Search NASA

Results for “physical samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Predicting 3D moisture sorption behavior of materials from 1D investigations

Abstract Moisture in materials can be a source of future outgassing and exacerbate unwanted changes in physical and chemical properties. Here, we investigate the effect of sample size and shape on the moisture transport phenomena through a combined experimental and modeling approach. Several different materials varying in size and shape were investigated over a wide range of relative humidities (0–90%) and temperatures ( $$30{-}70^{\,\circ } \hbox {C}$$ 30 - 70 ∘ C ) using gravimetric type dynamic vapor sorption (DVS). A dynamic triple-mode sorption model, developed previously, was employed to describe the experimental results with good success; the model includes absorption, adsorption, pooling (clustering) of species, and molecular diffusion. Here we show that the full triple-mode sorption model is robust enough to predict the dynamic uptake and outgassing of 3-dimensional (3D) samples using parameters derived from quasi-1D samples. This successful demonstration on three different materials (filled polydimethylsiloxane (PDMS), unfilled PDMS, and ceramic inorganic composite) illustrates that the model is robust at describing the scale-independent physics and chemistry of moisture sorption and diffusion materials. This work demonstrates that while sorption mechanisms manifest in testing of all sample sizes, some of these mechanisms were so subtle that they were overlooked in our initial modeling and assessment, illustrating the importance of multi-scale experiments in the development of robust predictive capabilities. Our study also outlines the challenges and viable solutions for global optimization of a multi-parameter model. The ability to quantify moisture sorption and diffusion, independent of scale, using 1D lab-scale experiments enables prediction of long-term bulk materials behavior in real applications.

36 MATERIALS SCIENCE↗

An efficient random-sampling method for calculating double occupancy of Gutzwiller wave function in single-band 1D and 2D lattices

In this paper, we report a random sampling method for computing the expectation value of physical quantities based on the Gutzwiler variational wave function. As the first application, we calculated the double occupancy, which is a critical quantity for under- standing the correlation effects in many-body systems, for single-band 1D and 2D lattices. We demonstrated that the random sampling scheme is more efficient than an existing Metropolis Monte-Carlo algorithm. For the 1D Hubbard model with only nearest-neighbor hopping, our results are almost identical to the exact analytic solution. We have also studied systems to which analytic solutions are not available, including the 1D lattices with next-nearest-neighbor hopping and 2D lattices. In addition, constraints on real-space con gurations can be easily implemented in the current scheme to further improve the Gutzwiller wave function. As an example, we calculated the double occupancy for 1D Hubbard model by applying the constraint that all double-occupied sites are paired with an empty site. With enhanced correlation between double-occupied and empty sites, the constraint results in much improved ground-state energy for 1D Hubbard model with strong on-site repulsion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning for First Principles Calculations of Material Properties for Ferromagnetic Materials

The investigation of finite temperature properties using Monte-Carlo (MC) methods requires a large number of evaluations of the system’s Hamiltonian to sample the phase space needed to obtain physical observables as function of temperature. DFT calculations can provide accurate evaluations of the energies, but they are too computationally expensive for routine simulations. To circumvent this problem, machine-learning (ML) based surrogate models have been developed and implemented on high-performance computing (HPC) architectures. In this paper, we describe two ML methods (linear mixing model and HydraGNN) as surrogates for first principles density functional theory (DFT) calculations with classical MC simulations. These two surrogate models are used to learn the dependence of target physical properties from complex compositions and interactions of their constituents. We present the predictive performance of these two surrogate models with respect to their complexity while avoiding the danger of overfitting the model. An important aspect of our approach is the periodic retraining with newly generated first principles data based on the progressive exploration of the system’s phase space by the MC simulation. The numerical results show that HydraGNN model attains superior predictive performance compared to the linear mixing model for magnetic alloy materials.

Eisenbach, Markus↗

Visualization and efficient generation of constrained high-dimensional theoretical parameter spaces

We describe a set of novel methods for efficiently sampling high-dimensional parameter spaces of physical theories defined at high energies, but constrained by experimental measurements made at lower energies. Often, theoretical models such as supersymmetry are defined by many parameters, $\mathcal{O}$(10 – 100), expressed at high energies, while relevant experimental constraints are often defined at much lower energies, preventing them from directly ruling out portions of the space. Instead, the low-energy constraints define a complex, potentially non-contiguous subspace of the theory parameters. Naive scanning of the theory space for points which satisfy the low-energy constraints is hopelessly inefficient due to the high dimensionality, and the inverse problem is considered intractable. As a result, many theoretical spaces remain under-explored. We introduce a class of modified generative autoencoders, which attack this problem by mapping the high-dimensional parameter space to a structured low-dimensional latent space, allowing for easy visualization and efficient generation of theory points which satisfy experimental constraints. An extension without dimensional compression, which focuses on limiting potential information loss, is also introduced.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Computational Information Criterion for Particle-Tracking with Sparse or Noisy Data

Traditional probabilistic methods for the simulation of advection-diffusion equations (ADEs) often overlook the entropic contribution of the discretization, e.g., the number of particles, within associated numerical methods. Many times, the gain in accuracy of a highly discretized numerical model is outweighed by its associated computational costs or the noise within the data. Herein, we address the question of how many particles are needed in a simulation to best approximate and estimate parameters in one-dimensional advective-diffusive transport. To do so, we use the well-known Akaike Information Criterion (AIC) and a recently-developed correction called the Computational Information Criterion (COMIC) to guide the model selection process. Random-walk and mass-transfer particle tracking methods are employed to solve the model equations at various levels of discretization. Numerical results demonstrate that the COMIC provides an optimal number of particles that can describe a more efficient model in terms of parameter estimation and model prediction compared to the model selected by the AIC even when the data is sparse or noisy, the sampling volume is not uniform throughout the physical domain, or the error distribution of the data is non-IID Gaussian.

97 MATHEMATICS AND COMPUTING↗

A Machine Learning Framework for Modeling Ensemble Properties of Atomically Disordered Materials

Atomic disorder can strongly influence material properties such as charge transport, optical response, and catalytic activity. However, efficiently modeling these disorder effects remains challenging for first-principles methods due to the cost of sampling large configurational spaces and computing complex physical quantities. Recent advances of machine learning techniques, particularly graph neural networks (GNNs), has enabled the efficient and accurate predictions of complex material properties, offering promising tools for studying disordered systems. In this work, we present a general machine-learning-assisted computational framework that integrates equivariant GNNs with Monte Carlo simulations to compute the thermodynamic and ensemble-averaged functional properties of disordered materials. Using the surface-termination-disordered MXene monolayer Ti 3 C 2 T 2–x as a representative system, we find that electrical conductivity exhibits an emergent peak near the order–disorder phase transition temperature due to the interplay between electron scattering and doping. In contrast, optical conductivity remains largely insensitive to local atomic disorder and reflects the global surface chemical composition. These results highlight the role of atomic disorder in affecting material properties and demonstrate the potential of our approach for statistically modeling disorder effects in a wide range of materials such as high-entropy alloys and spin liquids.

MXene↗

The miniJPAS survey: AGN and host galaxy coevolution of X-ray-selected sources

Studies indicate strong evidence of a scaling relation in the local Universe between the supermassive black hole mass (MBH) and the stellar mass of their host galaxies (M * ). They even show similar histories across cosmic times of their differential terms: the star formation rate (SFR) and black hole accretion rate (BHAR). However, a clear picture of this coevolution is far from being understood. We selected an X-ray sample of active galactic nuclei (AGN) up to z = 2.5 in the miniJPAS footprint. Their X-ray to infrared spectral energy distributions (SEDs) have been modeled with the CIGALE code, constraining the emission to 68 bands, from which 54 are the narrow filters from the miniJPAS survey. For a final sample of 308 galaxies, we derived their physical properties, such as their M * , SFR, star formation history (SFH), and the luminosity produced by the accretion process of the central BH (L AGN ). For a subsample of 113 sources, we also fit their optical spectra to obtain the gas velocity dispersion from the broad emission lines and estimated the M BH . We calculated the BHAR in physical units depending on two radiative efficiency regimes. We find that the Eddington ratios (λ Edd ) and its popular proxy (L X /M * ) have a difference of 0.6 dex, on average, and a KS test indicates that they come from different distributions. Our sources exhibit a considerable scatter on the MBH - M * scaling relation, which can explain the difference between λ Edd and its proxy. We also modeled three evolution scenarios for each source to recover the integral properties at z = 0. Using the SFR and BHAR, we show a notable diminution in the scattering between MBH - M * . For the last scenario, we considered the SFH and a simple energy budget for the AGN accretion, and we retrieved a relation similar to the calibrations known for the local Universe. Our study covers ~1 deg 2 in the sky and is sensitive to biases in luminosity. Nevertheless, we show that, for bright sources, the link between the differential values (SFR and BHAR) and their decoupling based on an energy limit is the key that leads to the local M BH - M * scaling relation. In the future, we plan to extend this methodology to a thousand degrees of the sky using JPAS with an X-ray selection from eROSITA, to obtain an unbiased distribution of BHAR and Eddington ratios.

79 ASTRONOMY AND ASTROPHYSICS↗

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

07 ISOTOPE AND RADIATION SOURCES↗

Galaxy Zoo: 3D – crowdsourced bar, spiral, and foreground star masks for MaNGA target galaxies

ABSTRACT The challenge of consistent identification of internal structure in galaxies – in particular disc galaxy components like spiral arms, bars, and bulges – has hindered our ability to study the physical impact of such structure across large samples. In this paper we present Galaxy Zoo: 3D (GZ:3D) a crowdsourcing project built on the Zooniverse platform that we used to create spatial pixel (spaxel) maps that identify galaxy centres, foreground stars, galactic bars, and spiral arms for 29 831 galaxies that were potential targets of the MaNGA survey (Mapping Nearby Galaxies at Apache Point Observatory, part of the fourth phase of the Sloan Digital Sky Surveys or SDSS-IV), including nearly all of the 10 010 galaxies ultimately observed. Our crowdsourced visual identification of asymmetric internal structures provides valuable insight on the evolutionary role of non-axisymmetric processes that is otherwise lost when MaNGA data cubes are azimuthally averaged. We present the publicly available GZ:3D catalogue alongside validation tests and example use cases. These data may in the future provide a useful training set for automated identification of spiral arm features. As an illustration, we use the spiral masks in a sample of 825 galaxies to measure the enhancement of star formation spatially linked to spiral arms, which we measure to be a factor of three over the background disc, and how this enhancement increases with radius.

Masters, Karen L. (ORCID:0000000308469578)↗

Greedy emulators for nuclear two-body scattering

Applications of reduced basis method emulators are increasing in low-energy nuclear physics because they enable fast and accurate sampling of high-fidelity calculations, enabling robust uncertainty quantification. Here, in this paper, we develop, implement, and test two model-driven emulators based on the (Petrov-)Galerkin projection using the prototypical test case of two-body scattering with the Minnesota potential and a more realistic local chiral potential. The high-fidelity scattering equations are solved with the matrix Numerov method, a reformulation of the popular Numerov recurrence relation for solving special second-order differential equations as a linear system of coupled equations. A novel error estimator based on reduced-space residuals is applied to an active learning approach (a greedy algorithm) to choosing training samples (“snapshots”) for the emulator and contrasted with a proper orthogonal decomposition (POD) approach. Both approaches allow for computationally efficient offline-online decompositions, but the greedy approach requires many fewer snapshot calculations. These developments set the groundwork for emulating scattering observables based on chiral nucleon-nucleon and three-nucleon interactions and optical models, where computational speed-ups are necessary for Bayesian uncertainty quantification. Our emulators and error estimators are widely applicable to linear systems.

Bayesian methods↗

Soil physical and chemical measurements for topsoils collected during NEON campaign in East River, CO (06/14/2018-06/28/2018)

The package is part of the DOE Watershed Function Science Focus Area (SFA) project and includes soil physical and chemical measurements from topsoils collected at the East River, Colorado, in conjunction with the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) survey conducted in June 2018. The soil measurements include soil bulk density, soil volumetric water content, soil microbial biomass C (Carbon), N (Nitrogen) and C:N (C to N ratio), soil DNA yield, soil total extractable organic C, soil total extractable N, soil extractable nitrate, soil extractable ammonium, soil dissolved inorganic N, soil dissolved organic N, soil pH, soil TOC400 (total organic carbon at 400°C), soil ROC (residual oxidizable carbon), soil TIC (total inorganic carbon), soil TOC (total organic carbon), soil TC (total carbon), soil N, soil OM (organic matter) loss on ignition. Additional associated site metadata can be found in the ESS-DIVE package 10.15485/1618130. The dataset includes (1) 2018_NEON_soil_physical_chemical_measurements.csv: soil physical and chemical measurements indexed by soil sample IGSNs; (2) samples.csv: sample metadata file used to register International Generic Sample Numbers (IGSNs); (3) flmd.csv: file level metadata file; and (4) dd.csv: data dictionary file. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS (Catchment Hydrology and ↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Packages in KAC (2021 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 16 years. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 and non3013 containers in storage from 15 years to 20 years. These calculations addressed the potential for degraded fiberboard properties following 20 years in storage using degradation models developed previously. The updated degradation models developed in this report have been compared to the assumptions in these calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 20 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 20 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗