Search NASA⌕ Search

SEARCH · Search NASA

Results for “physiological temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Growth stage estimation

Of the three candidate approaches to adjustment of the crop calendar to account for year-to-year weather differences, the Robertson triquadratic unit, a function of a nonlinear function of maximum and minimum temperature and day length, best described the rate of phenological development of wheat. The adjustable crop calendar (ACC) as implemented for LACIE is used to calculate the daily increment of development through six physiological stages of growth. Topics covered include dormancy modeling, the spring restart model, spring wheat starter model, winter starter model, winter wheat starter model, inclusion of the moisture variable, and display of crop stage estimation results. Assessment of the ACC accuracy over the period of LACIE operation indicates that the adjustable crop calendars used provided more accurate information than would have been available using historical norms. The models performed best under the conditions from which they were derived (Canadian spring wheat) and most poorly for the dwarf varieties and Southern Hemisphere applications.

Whitehead, V. S.↗

BRN 3.1 Knockouts Affect the Vestibular, Autonomic, and Circadian Rhythm Responses to 2G Exposure

Our previous studies have demonstrated that 2G exposure via centrifugation significantly attenuated the daily mean and circadian rhythm amplitude of rat body temperature (Tb), heart rate, and activity (Act). In addition, 2G exposure activates neural responses in several vestibular, autonomic, and circadian nuclei. Although we have characterized the effect of 2G on an animal's physiological, neuronal, and behavioral responses, it will be important to understand the underlying neural and physiological mechanisms that mediate those responses. For example, the vestibular responses, proprioceptive feedback, or fluid shifts may be the critical factors that mediate the responses to 2G. As a first step to understand the relative importance of these different response pathways to altered gravitational fields, this study examined the contribution of the vestibular system by utilizing an animal model from molecular biology. Brain 3.1 (Bm 3.1) is a POU domain homeobox gene involved in the normal development of the vestibular and auditory system. Brn 3.1 deletion results in a loss of hair cells in the otoliths, semicircular canals, and cochlea. As a result mice with a Brn 3.1 deletion do not have a functioning vestibular or auditory system. The BRN 3.1 knockout mouse could be a very useful animal model for isolating the role of the vestibular system in mediating the physiological responses to 2G exposure. Therefore, this study compared the effect of 2G exposure via centrifugation between Brn 3.1 knockout (KO) versus Wildtype (W) mice.

Murakami, D. M.↗

A mathematical model of diurnal variations in human plasma melatonin levels

Studies in animals and humans suggest that the diurnal pattern in plasma melatonin levels is due to the hormone's rates of synthesis, circulatory infusion and clearance, circadian control of synthesis onset and offset, environmental lighting conditions, and error in the melatonin immunoassay. A two-dimensional linear differential equation model of the hormone is formulated and is used to analyze plasma melatonin levels in 18 normal healthy male subjects during a constant routine. Recently developed Bayesian statistical procedures are used to incorporate correctly the magnitude of the immunoassay error into the analysis. The estimated parameters [median (range)] were clearance half-life of 23.67 (14.79-59.93) min, synthesis onset time of 2206 (1940-0029), synthesis offset time of 0621 (0246-0817), and maximum N-acetyltransferase activity of 7.17(2.34-17.93) pmol x l(-1) x min(-1). All were in good agreement with values from previous reports. The difference between synthesis offset time and the phase of the core temperature minimum was 1 h 15 min (-4 h 38 min-2 h 43 min). The correlation between synthesis onset and the dim light melatonin onset was 0.93. Our model provides a more physiologically plausible estimate of the melatonin synthesis onset time than that given by the dim light melatonin onset and the first reliable means of estimating the phase of synthesis offset. Our analysis shows that the circadian and pharmacokinetics parameters of melatonin can be reliably estimated from a single model.

NASA Discipline Number 70-10↗

Considerations for Health and Performance During Surface Extravehicular Activities

BACKGROUND: NASA’s objectives for expanding human presence beyond low Earth orbit will require Extravehicular Activities (EVAs) on lunar and planetary surfaces. Given the physiological and functional demands of conducting surface EVAs in a pressurized spacesuit in reduced gravity environments, there is a possibility that crew injury and compromised physiological and/or functional performance may present. OVERVIEW: Many human health and performance knowledge gaps exist in regards to exploration EVA that require characterization to ensure safety, reliability, and mission success. To address knowledge gaps, EVA simulations in Earth-based analog environments and/or spacesuit simulators can be utilized to provide valuable insights into task-based physiologic and metabolic costs, cognitive loads, and associated operational limitations to inform future mission concepts. Physical workloads approaching 60% of maximum metabolic rates and 85% age-predicted heart rate maxima; core body temperatures approaching 100o F; and subjective responses indicating limited spare cognitive capacity via Bedford scale have been observed during ground-based exploration EVA simulations in the NASA Active Response Gravity Offload Simulator (ARGOS) and Neutral Buoyancy Lab (NBL) during simulated planetary EVAs in pressurized suits. Further, ground-based EVA analogs vary in their ability to simulate planetary EVA and resulting physical workloads. DISCUSSION: Metabolic costs, thermal burdens, functional strength, and cognitive impacts have been and must continue to be assessed in ground-based analogs to fully characterize operational demands and crew readiness levels for exploration EVA. Considerations should be given to enabling a new concept of high-tempo surface EVA operations and associated work-rest intervals, understanding human health and performance impacts of evolving commercial suit designs and capabilities, and predictive modeling and decision support capabilities to enable safe and successful EVA operations.

EVA↗

Considerations for Health and Performance during Surface Extravehicular Activities

BACKGROUND: NASA’s objectives for expanding human presence beyond low Earth orbit will require Extravehicular Activities (EVAs) on lunar and planetary surfaces. Given the physiological and functional demands of conducting surface EVAs in a pressurized spacesuit in reduced gravity environments, there is a possibility that crew injury and compromised physiological and/or functional performance may present. OVERVIEW: Many human health and performance knowledge gaps exist in regards to exploration EVA that require characterization to ensure safety, reliability, and mission success. To address knowledge gaps, EVA simulations in Earth-based analog environments and/or spacesuit simulators can be utilized to provide valuable insights into task-based physiologic and metabolic costs, cognitive loads, and associated operational limitations to inform future mission concepts. Physical workloads approaching 60% of maximum metabolic rates and 85% age-predicted heart rate maxima; core body temperatures approaching 100° F; and subjective responses indicating limited spare cognitive capacity via Bedford scale have been observed during ground-based exploration EVA simulations in the NASA Active Response Gravity Offload Simulator (ARGOS) and Neutral Buoyancy Lab (NBL) during simulated planetary EVAs in pressurized suits. Further, ground-based EVA analogs vary in their ability to simulate planetary EVA and resulting physical workloads. DISCUSSION: Metabolic costs, thermal burdens, functional strength, and cognitive impacts have been and must continue to be assessed in ground-based analogs to fully characterize operational demands and crew readiness levels for exploration EVA. Considerations should be given to enabling a new concept of high-tempo surface EVA operations and associated work-rest intervals, understanding human health and performance impacts of evolving commercial suit designs and capabilities, and predictive modeling and decision support capabilities to enable safe and successful EVA operations.

P Estep↗

An Investigation into the Effect of Liquid Accumulation on Thermo-Physiologic State using an Advanced Moisture Model Coupled with a High Resolution Human Thermal Model

A physics-based mathematical model for simulating heat and moisture transport on the skin and within clothing was developed to improve the accuracy of human thermal modeling predictions. In a previous study, a set of sweating hotplate experiments was specifically created to obtain test data for model validation. The clothing moisture model was subsequently coupled with a human thermal model and tested by simulating human experiments described in the open literature, which served to verify the model’s ability to predict whole body thermo-physiologic state in work-rest cycles during which sweating was known to occur. In this study, a human subject test was specifically designed to validate the model’s ability to predict local and whole body sweat evaporation and accumulation on the surface of the body. The human subject test incorporated twelve clothed male subjects of moderate physical fitness, ages 18-30, which were prescribed a work-rest cycle in a climate-controlled chamber (25 °C, 50% RH). Two activity levels were considered during the active stage (4 MET vs. 6.5 MET), and two sets of ending ambient conditions were considered for the final rest stage (25 °C vs. 15 °C, 50% RH). Model predictions were compared to the measured local skin temperatures, core temperatures, and whole body sweat losses. In general, the model was able to reproduce the trends observed in the human subject trial, but more importantly, provided insight into how dynamic changes in liquid content can impact the evolution of local and whole body thermo-physiologic state. This study demonstrates the ability of an advanced moisture model to capture distinct physics attributable to moisture accumulation, allowing for increased accuracy in predicting human thermal state and for interpreting the results of measurements derived from human subject tests.

human thermal model↗

Spectral Survey of Irrigated Region Corps and Soils

The applications of remote sensing techniques to spectral surveys of irrigation, crops, and soils are reported. Topics discussed include: (1) canopy temperature as an indication of plant water stress, (2) temperature of soils and of crop canopies differing in water conditions, (3) ERTS project, (4) spectrum matching and pattern recognition, (5) photographic procedures and interpretation, (6) interaction of light with plants, and (7) plant physiological and histological factors.

Source record↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Role of skin blood flow and sweating rate in exercise thermoregulation after bed rest

Two potential mechanisms, reduced skin blood flow (SBF) and sweating rate (SR), may be responsible for elevated intestinal temperature (T(in)) during exercise after bed rest and spaceflight. Seven men underwent 13 days of 6 degrees head-down bed rest. Pre- and post-bed rest, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-bed rest supine peak exercise capacity) in a thermoneutral room. After bed rest, T(in) was elevated at rest (+0.31 +/- 0.12 degrees C) and at the end of exercise (+0.33 +/- 0.07 degrees C). Percent increase in SBF during exercise was less after bed rest (211 +/- 53 vs. 96 +/- 31%; P < or = 0.05), SBF/T(in) threshold was greater (37.09 +/- 0.16 vs. 37.33 +/- 0.13 degrees C; P < or = 0.05), and slope of SBF/T(in) tended to be reduced (536 +/- 184 vs. 201 +/- 46%/ degrees C; P = 0.08). SR/T(in) threshold was delayed (37.06 +/- 0.11 vs. 37.34 +/- 0.06 degrees C; P < or = 0.05), but the slope of SR/T(in) (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg x min-1 x cm-2 x degrees C-1) and total sweat loss (0.42 +/- 0.06 vs. 0.44 +/- 0.08 kg) were not changed. The higher resting and exercise T(in) and delayed onset of SBF and SR suggest a centrally mediated elevation in the thermoregulatory set point during bed rest exposure.

NASA Discipline Cardiopulmonary↗

Exercise thermoregulation after 6 h of chair rest, 6 degrees head-down bed-rest, and water immersion deconditioning in men

The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (Tre) and mean skin (Tsk) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) m2; maximum oxygen uptake (VO2max), 48 (6) ml.min-1.kg-1; whilst supine in air at dry bulb temperature 23.2 (0.6) degree C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m.min-1] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6 degree head-down bed rest (BR), and 20 degree (WI20) and 80 degree (WI80) foot-down water immersion [water temperature, 35.0 (0.1) degree C]. Compared with the AC exercise delta Tre [mean (SD) 0.77 (0.13) degree C (*P < 0.05), after WI80 0.96 (0.13) degree C*, and after WI20 1.03 (0.09) degree C*. All Tsk responded similarly to exercise: they decreased (NS) by 0.5-0.7 degree C in minutes 4-8 and equilibrated at +0.1 to +0.5 degree C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ.m-2.h-1.degree C-1). Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to Tre at 70 min (Tre70) than limb sweat rate or blood flow. Only 36% of the variability in Tre70 could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

NASA Discipline Regulatory Physiology↗

Stress Counter-Response Training Via Physiological Self-Regulation During Flight Simulation

This study provided the first evaluation of a new training concept and technology aimed at training pilots to maintain physiological equilibrium during circumstances in an airplane cockpit. Thirty healthy subjects (16 males and 14 females) between the ages of 18 and 35 were randomized into two study groups, A and B. Subjects participated individually in a sequence of four study sessions. In the first visit, subjects were taught to operate a desktop fighter jet flight simulation program. In the three sessions that followed, subjects in group A were trained to minimize their autonomic deviation from baseline values while operating the desktop flight simulation. This was done by making their skin conductance and hand temperature deviations from baseline impair the functionality of the aircraft controls. Subjects also received auditory and visual cues about their autonomic deviation, and were instructed to keep these within pre-set limits to retain full control of the aircraft. Subjects in group B were subjected to periods of impaired aircraft functionality independent of their physiologic activity, and thus served as a control group. No statistically significant group differences were found in the flight performance scores from the three training sessions, and post-training flight performance scores of the two groups were not different. We conclude that this study did not provide clear support for this training methodology in optimizing pilot performance. However, a number of shortcomings in the current status of this training methodology may account for the lack of demonstrable training benefit to the experimental group. Suggested future modifications for research on this training methodology include: Limiting the amount of instrument impairment resulting from physiological deviations; conducting a greater number of physiological training sessions per subject; using pre-post training performance tests which invoke a greater amount of stress in subjects; and developing a more detailed performance scoring system.

Palsson, Olafur S.↗

Microbial ecology of extreme environments: Antarctic dry valley yeasts and growth in substrate-limited habitats

The success of the Antarctic Dry Valley yeasts presumeably results from adaptations to multiple stresses, to low temperatures and substrate-limitation as well as prolonged resting periods enforced by low water availability. Previous investigations have suggested that the crucial stress is substrate limitation. Specific adaptations may be pinpointed by comparing the physiology of the Cryptococcus vishniacii complex, the yeasts of the Tyrol Valley, with their congeners from other habitats. Progress was made in methods of isolation and definition of ecological niches, in the design of experiments in competition for limited substrate, and in establishing the relationships of the Cryptococcus vishniacii complex with other yeasts. In the course of investigating relationships, a new method for 25SrRNA homology was developed. For the first time it appears that 25SrRNA homology may reflect parallel or convergent evolution.

Vishniac, H. S.↗

Lunar Dust and Lunar Simulant Activation, Monitoring, Solution and Cellular Toxicity Properties

During the Apollo missions, many undesirable situations were encountered that must be mitigated prior to returning humans to the moon. Lunar dust (that part of the lunar regolith less than 20 m in diameter) was found to produce several problems with astronaut s suits and helmets, mechanical seals and equipment, and could have conceivably produced harmful physiological effects for the astronauts. For instance, the abrasive nature of the dust was found to cause malfunctions of various joints and seals of the spacecraft and suits. Additionally, though efforts were made to exclude lunar dust from the cabin of the lunar module, a significant amount of material nonetheless found its way inside. With the loss of gravity correlated with ascent of the lunar module from the lunar surface to rendezvous with the command module, much of the major portions of the contaminating soil and dust began to float, irritating the astronaut s eyes and being inhaled into their lungs. Our goal has been to understand some of the properties of lunar dust that could lead to possible hazards for humans. Due to the lack of an atmosphere, there is nothing to protect the lunar soil from ultraviolet radiation, solar wind, and meteorite impacts. These processes could all serve to activate the soil, or produce reactive surface species. In order to understand the possible toxic effects of the reactive dust, it is necessary to reactivate the dust, as samples returned during the Apollo missions were exposed to the atmosphere of the Earth. We have used grinding and UV exposure to mimic some of the processes occurring on the Moon. The level of activation has been monitored using two methods: fluorescence spectroscopy and electron paramagnetic resonance spectroscopy (EPR). These techniques allow the monitoring of hydroxyl radical production in solution. We have found that grinding of lunar dust produces 2-3 times the concentration of hydroxyl radicals as lunar simulant and 10 times that of quartz. Exposure of the lunar dust to UV radiation under vacuum was also found to lead to hydroxyl radical production. After grinding, we have also monitored loss of reactivity of the dusts by exposing them to conditions of known humidity and temperature. From these tests, it was found that the reactivity half-life of lunar simulant is approximately 3 hours, while that of quartz is approximately 2 hours. Placing lunar dust in solution could lead to effects on mechanical and physiological systems, as well as other biological systems. For instance, while it is known that lunar dust is highly abrasive and caused a variety of problems with suits and equipment during Apollo, it is unknown as to how these properties might be affected in the presence of water or other liquids. It is possible that the dust may release minerals (e.g., metallic nanophase Fe) into solution that could speed corrosion or rust. Also, as lunar dust produces hydroxyl radicals (and possibly other reactive oxygen species) in solution, these radicals could also lead to the breakdown of suit or habitat materials. In the body (i.e., in lung solution), the effects could be two-fold. First, if the lunar dust dissolves, it may release an excess of elements (such as zero-valence metallic Fe) that are necessary for bodily functions but only in certain concentration ranges. For lunar dust, the presence of nanophase iron being released into the body is a concern. Secondly, the hydroxyl radicals or other reactive oxygen species produced by the dust in solution could conceivably interact with cells, leading to various problems. We have studied the dissolution of both ground and unground lunar simulant in buffer solutions of different pH. The concentration of a number of species was determined using mass spectrometry. These studies showed that lowering the pH of the solution causes a dramatic increase in the amount of each element released into solution and that grinding also produces higher concentrations. Finally, we have perfmed initial tests aimed at understanding the effects of lunar simulant on cellular systems. Alveolar epithelial cells were cultured and exposed to different concentrations of dust suspended in cell culture media. After predetermined amounts of time, the media was removed and the concentrations of important inflammatory cytokines (IL6, IL8, and TNF-alpha ) were measured. The results of these tests are being used to develop the correct protocols for tests to be performed using lunar dust samples.

Jeevarajan, A.S.↗

In vitro activities of four xyloglucan endotransglycosylases from Arabidopsis

Xyloglucan endotransglycosylases (XETs) are encoded by a gene family in Arabidopsis thaliana. These enzymes modify a major structural component of the plant cell wall, xyloglucan, and therefore may influence plant growth and development. We have produced four Arabidopsis XETs (TCH4, Meri-5, EXGT and XTR9) using the baculovirus/insect cell system and compared their biochemical activities. TCH4, as previously demonstrated, and the other three proteins are capable of carrying out transglycosylation of xyloglucans. The K(m) for XLLGol acceptor oligosaccharide is in the range of 20-40 microM for all the XETs except XTR9, which has a Km of 5 microM and is significantly inhibited by high levels of XLLGol. All four enzymes are most active between pH 6.0 and 6.5. TCH4 and XTR9 have temperature optima of 18 degrees C, whereas Meri-5 and EXGT are most active at 28 and 37 degrees C, respectively. Although the activity levels of three of the XETs are not influenced by the presence of fucose on the xyloglucan polymer, XTR9 has a clear preference for non-fucosylated xyloglucan polymer. The four XETs show a marked preference for XLLGol over either XXFGol or XXXGol as acceptor oligosaccharide. All four XETs are glycosylated; however, only the activities of TCH4 and Meri-5 are affected by the removal of the N-glycan with PNGase F. These four enzymes most likely function solely as transglycosylases because xyloglucan endoglucanase activity was not apparent. Subtle differences in biochemical activities may influence the physiological functions of the distinct XETs in vivo.

Non-NASA Center↗

Effects of menstrual cycle phase and oral contraceptives on alertness, cognitive performance, and circadian rhythms during sleep deprivation

The influence of menstrual cycle phase and oral contraceptive use on neurobehavioral function and circadian rhythms were studied in healthy young women (n = 25) using a modified constant routine procedure during 24 h of sleep deprivation. Alertness and performance worsened across sleep deprivation and also varied with circadian phase. Entrained circadian rhythms of melatonin and body temperature were evident in women regardless of menstrual phase or oral contraceptive use. No significant difference in melatonin levels, duration, or phase was observed between women in the luteal and follicular phases, whereas oral contraceptives appeared to increase melatonin levels. Temperature levels were higher in the luteal phase and in oral contraceptive users compared to women in the follicular phase. Alertness on the maintenance of wakefulness test and some tests of cognitive performance were poorest for women in the follicular phase especially near the circadian trough of body temperature. These observations suggest that hormonal changes associated with the menstrual cycle and the use of oral contraceptives contribute to changes in nighttime waking neurobehavioral function and temperature level whereas these factors do not appear to affect circadian phase.

NASA Discipline Regulatory Physiology↗

Advanced sensor systems for biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 .mu.W., which yields a lifetime of approximately 6-9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38.times.28 mm to 22.times.8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗

Advanced Sensor Systems for Biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 microW, which yields a lifetime of approximately 6 - 9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38 x 28 mm to 22 x 8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗