Search NASA⌕ Search

SEARCH · Search NASA

Results for “pilot ratings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Rooftop Solar in Lawrence, MA: Community Perspectives, Deceptive Practices, and Financing Options

This report was prepared as part of the U.S. Department of Energy's Communities Local Energy Action Program (Communities LEAP) pilot competitive technical assistance for the Lawrence Massachusetts Stakeholder Coalition (LSC) composed of The City of Lawrence, All In Energy, MassDevelopment, Mill City Community Investments, BlocPower and Groundwork Lawrence, and led by Browning the Green Space. The LSC identified rooftop solar photovoltaics as a top priority for this technical assistance opportunity. Lawrence faces high energy burden and electricity prices, thus rooftop solar can be a tool to help lower those costs. However, the coalition received feedback that some solar companies were using deceptive and unfair practices when marketing, selling, or financing solar energy, costing residents more money than utility rates and increasing the energy burden. This project sought to address rooftop solar community priorities through two pathways: 1. facilitating community engagement to understand community perspectives and experiences with rooftop solar development; and 2. conducting a financial cash-flow analysis highlighting the varying fiscal outcomes for rooftop solar adopters based off rooftop solar leasing, ownership, or buying electricity from the utility (National Grid).

14 SOLAR ENERGY↗

A matched-filter approach to radio variability and transients: searching for orphan afterglows in the VAST Pilot Survey

Radio transient searches using traditional variability metrics struggle to recover sources whose evolution time-scale is significantly longer than the survey cadence. Motivated by the recent observations of slowly evolving radio afterglows at gigahertz frequency, we present the results of a search for radio variables and transients using an alternative matched-filter approach. We designed our matched-filter to recover sources with radio light curves that have a high-significance fit to power-law and smoothly broken power-law functions; light curves following these functions are characteristic of synchrotron transients, including ‘orphan’ gamma-ray burst afterglows, which were the primary targets of our search. Applying this matched-filter approach to data from Variables and Slow Transients Pilot Survey conducted using the Australian SKA Pathfinder, we produced five candidates in our search. Subsequent Australia Telescope Compact Array observations and analysis revealed that: one is likely a synchrotron transient; one is likely a flaring active galactic nucleus, exhibiting a flat-to-steep spectral transition over 4 months; one is associated with a starburst galaxy, with the radio emission originating from either star formation or an underlying slowly evolving transient; and the remaining two are likely extrinsic variables caused by interstellar scintillation. The synchrotron transient, VAST J175036.1–181454, has a multifrequency light curve, peak spectral luminosity, and volumetric rate that is consistent with both an off-axis afterglow and an off-axis tidal disruption event; interpreted as an off-axis afterglow would imply an average inverse beaming factor $\langle f^{-1}_{\text{b}} \rangle = 860^{+1980}_{-710}$, or equivalently, an average jet opening angle of $\langle \theta _{\textrm {j}} \rangle = 3^{+4}_{-1}\,$ deg.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation of the L-mode density limit with edge collisionality

The "density limit'' is one of the fundamental bounds on tokamak operating space, and is commonly estimated via the empirical Greenwald scaling. This limit has garnered renewed interest in recent years as it has become clear that ITER and many tokamak pilot plant concepts must operate near or above the widely-used Greenwald limit to achieve their objectives. Evidence has also grown that the Greenwald scaling - in its remarkable simplicity - may not capture the full complexity of the disruptive density limit. In this study, we assemble a multi-machine database to quantify the effectiveness of the Greenwald limit as a predictor of the L-mode density limit and identify alternative stability metrics. We find that a two-parameter dimensionless boundary in the plasma edge, $\nu_{*\rm, edge}^{\rm limit} = 3.0 \beta_{T,{\rm edge}}^{-0.4}$, achieves significantly higher accuracy (true negative rate of 97.7\% at a true positive rate of 95\%) than the Greenwald limit (true negative rate 86.1\% at a true positive rate of 95\%) across a multi-machine dataset including metal- and carbon-wall tokamaks (AUG, C-Mod, DIII-D, and TCV). The collisionality boundary presented here can be applied for density limit avoidance in current devices and in ITER, where it can be measured and responded to in real time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

US Department of Energy, Office of Science, High-Performance Computing Facility: 2023 Operational Assessment Oak Ridge Leadership Computing Facility

The Oak Ridge Leadership Computing Facility (OLCF) was established to accelerate scientific discovery by providing world-leading computational performance and advanced data infrastructure. As a US Department of Energy (DOE) Office of Science user facility, the OLCF has managed the successful deployment and operation of a succession of leadership-class resources dedicated to open science. In addition to these resources, the OLCF staff continually strive to develop innovative processes and technologies, improve security, and empower users through effective allocation management and comprehensive user support and training. These efforts support the advancement of science by the OLCF users and benefit high-performance computing (HPC) facilities around the world. In calendar year (CY) 2023, the OLCF supported 1,676 users and 598 projects and exceeded all targets for user satisfaction. The facility received an average satisfaction score of 4.52 out of 5 on the annual user survey, and 94% of respondents reported a high satisfaction rate with the OLCF overall. Of the 3,619 user tickets submitted in CY 2023, OLCF staff resolved 97% within 3 business days. The facility opened Frontier to full scientific operations this year. Two projects conducted on Frontier received the Association for Computing Machinery (ACM) Gordon Bell Prize and the Gordon Bell Special Prize for Climate Modeling, and a third earned a nomination as a Gordon Bell Prize finalist. The facility’s previous flagship machine, Summit, gained new life and was extended through 2024 in part to help provide resources to the Integrated Research Infrastructure (IRI) projects and the National Artificial Intelligence Research Resource (NAIRR) pilot program. The facility instantiated an Advanced Computing Ecosystem testbed in part to support IRI workflows. OLCF made interactivity easier and more accessible to users than ever through tools like Jupyter notebooks and workflows.

97 MATHEMATICS AND COMPUTING↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MWth with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MWth and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MW th with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MW th and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Integrating high resolution drone imagery and forest inventory to distinguish canopy and understory trees and quantify their contributions to forest structure and dynamics

Tree growth and survival differ strongly between canopy trees (those directly exposed to overhead light), and understory trees. However, the structural complexity of many tropical forests makes it difficult to determine canopy positions. The integration of remote sensing and ground-based data enables this determination and measurements of how canopy and understory trees differ in structure and dynamics. Here we analyzed 2 cm resolution RGB imagery collected by a Remotely Piloted Aircraft System (RPAS), also known as drone, together with two decades of bi-annual tree censuses for 2 ha of old growth forest in the Central Amazon. We delineated all crowns visible in the imagery and linked each crown to a tagged stem through field work. Canopy trees constituted 40% of the 1244 inventoried trees with diameter at breast height (DBH) > 10 cm, and accounted for ~70% of aboveground carbon stocks and wood productivity. The probability of being in the canopy increased logistically with tree diameter, passing through 50% at 23.5 cm DBH. Diameter growth was on average twice as large in canopy trees as in understory trees. Growth rates were unrelated to diameter in canopy trees and positively related to diameter in understory trees, consistent with the idea that light availability increases with diameter in the understory but not the canopy. The whole stand size distribution was best fit by a Weibull distribution, whereas the separate size distributions of understory trees or canopy trees > 25 cm DBH were equally well fit by exponential and Weibull distributions, consistent with mechanistic forest models. The identification and field mapping of crowns seen in a high resolution orthomosaic revealed new patterns in the structure and dynamics of trees of canopy vs. understory at this site, demonstrating the value of traditional tree censuses with drone remote sensing.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of SRPPF ARS Effluent Variations on Magnesium Oxysulfate Solidification

A magnesium oxysulfate (MOS) grout formulation has been identified to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO (28 wt%), anhydrous MgSO 4 (10 wt%), and dead burnt MgO (62 wt%), resulting in a grout with good mixability, acceptable density, acceptable setting times, and a leachate pH around 9.4, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. A series of tests were then designed to observe how this formula reacted to variations in the liquid effluent. Liquid effluent temperature, the caustic pH level, concentration of NaNO 3 , and the presence of neutralization products, trace metals, and/or sodium sulfate (all potential residuals found in the effluent from upstream processing), were evaluated to see how each impacts the grout mixing time, peak temperature, setting time, presence of bleed water, leachate pH, and density. The standard mix has an average mixing time of 18 minutes, peak temperature of 100.5 °C, and set time of 60 minutes. Increasing the temperature of the liquid effluent increased the reaction rate of the mix and reduced mixing and setting times. Between 30 and 40°C the change was relatively small, raising no more than 6 °C compared to the standard mix maximum temperature. Increasing the pH of the liquid effluent had no significant impact on the mix. The addition of neutralization products and trace metals had an overall impact of decreasing the reactivity of the mix. The addition of more ions in the liquid effluent, such as an increase in the concentration of NaNO 3 and the addition of Na 2 SO 4 , generally decreased the reactivity of the mix. None of the variations to the liquid effluent hindered solidification as indicated by the lack of bleed water found on all the samples. The leachate pH values for all mixes tested did not significantly vary from the expected pH of 9.4 and none of the density values fell below 1.8 g/cm 3 . Overall, changes to the liquid effluent were found to have a minimal impact on the formulation suggesting the grout's ability to properly form despite increased temperatures and the presence of residuals typically found in the liquid effluent from the ARS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial Energy Code Compliance – Just the Facts, Ma’am

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. This paper builds on the methodology presented at the 2016 Summer Study and provides a first glimpse of the results as seen in the field. The field study team has implemented the pilot methodology, compiling a data set of over 200 office and retail buildings in climate zones 2A and 5A. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This paper will review the findings of that analysis, discuss critical aspects of the methodology, such as sampling and recruitment strategies, and identify areas where the greatest return—bang for the buck—exists in improving compliance with codes in commercial buildings. In addition, the team will make specific recommendations for jurisdictions looking to use the methodology to maximize energy code savings achieved in the field.

Cheslak, Kimberly↗

A novel sub-pilot-scale direct-contact ultrasonic dehydration technology for sustainable production of distillers dried grains (DDG)

DDG is a major source of protein, calcium, phosphorus, and sulfur is arguably the most important byproduct of the bioethanol industry with increasing demand over the past few years. Reducing energy consumption in the DDG production process and energy recovery from DDG is vital for sustainable bioethanol productions. In this paper, a novel direct-contact multi-frequency, multimode, and modulated (MMM) ultrasonic dryer (US) was developed for the first time and has been applied in dehydration of wet distillers' grain (WDG). Ultrasonic drying (US) was combined with a convective airflow (HA) at different temperatures of 25 (room temperature), 50 and 70 °C to evaluate the impact of US, HA, and US + HA on drying kinetics, activation energy, chemical compositions, microstructure, and color of DDG. Semi-empirical kinetic models were developed and evaluating drying performances showed that the application of ultrasound significantly enhanced the drying rate and decreased the drying time (by 46%), especially at low drying temperatures. The activation energy for moisture removal in the presence of ultrasound was about 50% of that without ultrasound. The final dried distillers' grains product processed by ultrasonic drying had a brighter color, a higher available protein, a higher digestible protein (the lowest acid detergent insoluble crude protein), and a better surface profile with no compromise on minerals and fiber contents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Pilot-scale hydrotreating of catalytic fast pyrolysis biocrudes: process performance and product analysis

Catalytic fast pyrolysis (CFP) is a technology option for producing advanced biofuels from hydrocarbon-rich biocrude intermediates. The relatively high oxygen content of biocrudes compared to petroleum intermediates increases hydrogen consumption and the lower thermal stability accelerates catalyst deactivation and reactor fouling hindering the adaptation of hydrotreating technology for biocrude upgrading into biofuels. In this study, four chemically different biocrude feeds were upgraded in a pilot scale hydroprocessing unit at similar process conditions using a commercial hydrodeoxygenation (HDO) catalyst. The biocrude feeds and hydrotreated products were characterized using standard ASTM procedures and advanced analytical techniques (GCxGC-FID and GCxGC-MS). HDO catalyst activity was monitored by changes in physical properties and chemical composition of the upgraded products as a function of time on stream. Aliphatic acids, ketones, aldehydes, and furan derivatives were completely converted during the hydrotreating tests while the concentration of aromatics, aliphatic hydrocarbons and phenolics increased during the hydrotreating tests. The oxygen content, nitrogen content, specific gravity, viscosity and the heavy end of the boiling point range (determined by simulated distillation) of the upgraded products increased with increasing time on stream during hydrotreating. The deactivation rate was the lowest for the biocrude feed that contained the most aliphatic and aromatic hydrocarbons and was the highest for the biocrude feed that had the most anhydrosugars. Overall, the HDO deactivation rate correlates with the total amount of oxygen in the feed (17 wt% to 29 wt%, on a wet basis).

09 BIOMASS FUELS↗

A Pilot-Scale Evaluation of Natural Gas-Based Foam at Elevated Pressure and Temperature Conditions

Abstract Nitrogen (N2) and Carbon Dioxide (CO2) foams have been used as hydraulic fracturing fluids for several decades to reduce water usage and minimize damage in water-sensitive reservoirs. These foam treatments require gases to be liquefied and transported to site. An alternative approach would be to use natural gas (NG) that is readily available from nearby wells, pipelines, and processing facilities as the internal, gaseous phase to create a NG-based foam. Hydraulic fracturing with NG foam is a relatively inexpensive option, makes use of an abundant and often wasted resource, and may even provide production benefits in certain reservoirs. As part of an ongoing development project sponsored by the Department of Energy (DOE), the surface process to create NG foam is being developed and the properties of NG foam are being explored. This paper presents recent results from a rigorous pilot-scale demonstration of NG foam over a range of operating scenarios relevant to surface and bottomhole conditions with a variety of base-fluid mixtures. The Pilot-scale Foam Test Facility (PFTF) used in these investigations is first described. The PFTF is capable of generating foamed fluids at pressures up to 7,500 psig and at temperatures in excess of 300°F. Then, results from several investigations aimed at proving NG foam at conditions relevant to the field are presented. NG foam was characterized using rheology measurements and flow visualization techniques. Experiments were performed to investigate the texture and stability of NG foam generated by two different mixing methods: one using a custom designed tee to match mixing velocities in the field where the gas phase is jetted into the aqueous stream, and another to ensure comprehensive mixing for laboratory analysis. Parametric studies were conducted to explore the effects of flow rate, foam quality, and temperature on the stability of NG foam. Moreover, different fluid preparations were used to investigate the effect of base fluid and additive concentrations on the stability of NG foams. Additional laboratory studies that investigated foam stability with produced water and multicomponent NG mixtures are also reported. The NG foams explored in these investigations exhibited typical, shear-thinning behavior observed in rheological studies of N2- and CO2-based foams. The measured viscosity and observed stability indicate that NG foams are well suited for fracturing applications. Like other foams, NG foam exhibits sensitivity to operating temperature characterized by a decrease in apparent viscosity as temperature increases. Rapid foam breakdown was observed at significantly elevated temperatures exceeding 290°F. In addition to fluid characterization, these investigations also yielded several key lessons that should be applied to future field demonstrations of NG foam.

Beck, Griffin↗

MW-Class SOFC Pilot System Development

The overall objective of this project is to develop a low-cost, efficient, and reliable MWe-class Solid Oxide Fuel Cell (SOFC) power system towards commercial deployment in natural-gas fueled distributed generation applications. This report details the successful completion of all project objectives. The main goals of the project were to develop the conceptual design of a MWe-class SOFC power system, and to complete a techno-economic analysis (TEA) to determine system costs at low-volume production levels of >100MW per year. The combination of the BoP equipment cost and SOFC stack module factory cost provided the net fabrication cost of the selected 1MW SOFC system configuration. The results of the study showed that the cost target of less than $6000/kW is achievable for a FOAK 1MW SOFC system, exclusive of the first-time engineering cost. Also, the project included an exploratory analysis of the factory cost of next generation stack technology based on the Compact Solid-oxide Architecture (CSA) design at a high annual manufacturing rate of one-GW produced in a giga-factory. The BoP capital cost for one giga-watt power production was estimated using learning-curve analysis based on the historical manufacturing cost data related to similar high temperature Molten Carbonate fuel cell systems built by FuelCell Energy (FCE). The giga-factory manufactured SOFC cost estimate combined with the BoP cost at high production rates led to the estimation of entire system capital cost. Ultimately, a Cost of Electricity (COE) analysis was performed including natural gas fuel prices, installation and O&M costs, and stack replacement cost. The results of the techno-economic analysis were summarized by parametric estimation of COE for 1MW SOFC NOAK (Nth-of-a-Kind) system with natural gas prices as a variable parameter.

08 HYDROGEN↗

Colorado Residential Retrofit Energy District (CoRRED) Phase I: Final Modeling Results

Electrification of buildings and transportation coupled with increased deployment of distributed energy resources (DERs) has been identified as a key step toward meeting emissions reduction goals across the U.S. Examples of pilot projects that feature innovative, 'smart' electric neighborhoods are largely focused on new construction projects, but there is a need to address the millions of existing homes so that they too may accommodate cleaner yet variable energy production in ways that benefit both the utility grid and the homes' residents. The Colorado Residential Retrofit Energy District (CoRRED) project used building and grid co-simulation tools to model an advanced energy district demonstration in an existing residential neighborhood in Denver, Colorado, and explored how existing building and utility infrastructures can be enhanced with combinations of traditional energy-efficiency retrofit measures and integration of solar panels and other DER technologies to provide better affordability and reliability. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate. Our results clearly indicate that incorporating DERs into efficient electrification produces much bigger utility bill savings on an annual basis than efficient electrification without DERs. While electrifying a neighborhood will increase the maximum load, batteries and solar panels can reduce load during peak hours so that the community can be a net producer during peak periods. A remaining challenge is to overcome first cost barriers to implementing energy-efficiency and DER technologies, as modest utility bill savings require long payback periods that are not practical for most homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗