Analysis, Verification, and Application of Equations and Procedures for Design of Exhaust-pipe Shrouds

Investigations were made to develop a simplified method for designing exhaust-pipe shrouds to provide desired or maximum cooling of exhaust installations. Analysis of heat exchange and pressure drop of an adequate exhaust-pipe shroud system requires equations for predicting design temperatures and pressure drop on cooling air side of system. Present experiments derive such equations for usual straight annular exhaust-pipe shroud systems for both parallel flow and counter flow. Equations and methods presented are believed to be applicable under certain conditions to the design of shrouds for tail pipes of jet engines.

HEAT EXCHANGERS, SHROUDED↗

Modeling heat pipe startup and noncondensable gases in Sockeye

For this work, a one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of noncondensable gases. Additionally, a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup and noncondensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling noncondensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING↗

Pipeline for Integrated Projects in Energy Systems (PIPES): A Tool for Integrated System Planning [Slides]

The Pipeline for Integrated Projects in Energy Systems (PIPES) is a comprehensive project, data, and workflow management tool designed for integrated modeling teams. PIPES facilitates the management of data requirements, tasks, and progress tracking, serving as a higher-level integration layer that works across various data and modeling software. This tool integrates models, data, and tools to perform large-scale, integrated analysis work at scale. PIPES is designed to streamline integrated modeling projects, enhance collaboration, and ensure the quality and efficiency of data management and workflow processes. This presentation introduces PIPES a multi-model tool for integrated system planning; it describes the underlying architecture, deep dives into common user workflows, and outlines the upcoming development roadmap beyond its current alpha state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Heat Pipe Startup And Noncondensable Gases In Sockeye

A one-dimensional gas mixture flow model was developed and implemented in the heat pipe code Sockeye to model the effects of non-condensable gases. Additionally a startup model based on the dusty gas model was implemented to model the transition from rarefied gas dynamics to continuum flow, which occurs during the frozen startup of high-temperature heat pipes. Multiple startup models and non-condensable gas models were tested against experimental data for sodium heat pipes, showing excellent agreement. Additionally, the newly developed gas mixture model for modeling non-condensable gas is further tested with a theoretical case study with arbitrary heating configurations. Finally, several recommendations and conclusions are made from the studies in this work to guide future heat pipe modeling efforts.

97 - MATHEMATICS AND COMPUTING↗

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Loop Heat Pipe Startup Behaviors

A loop heat pipe must start successfully before it can commence its service. The start-up transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe start-up behaviors. Topics include the four start-up scenarios, the initial fluid distribution between the evaporator and reservoir that determines the start-up scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power start-up, and methods to enhance the start-up success. Also addressed are the thermodynamic constraint between the evaporator and reservoir in the loop heat pipe operation, the superheat requirement for nucleate boiling, pressure spike and pressure surge during the start-up transient, and repeated cycles of loop start-up andshutdown under certain conditions.

Loop Heat Pipes↗

Introduction to Heat Pipes

This is the presentation file for the short course Introduction to Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. NCTS 21070-15. Course Description: This course will present operating principles of the heat pipe with emphases on the underlying physical processes and requirements of pressure and energy balance. Performance characterizations and design considerations of the heat pipe will be highlighted. Guidelines for thermal engineers in the selection of heat pipes as part of the spacecraft thermal control system, testing methodology, and analytical modeling will also be discussed.

Heat Pipes↗

Intermediate Temperature Ceramic Heat Pipe Modeling and Optimization

The intermediate temperature regime of heat pipes, 450-700 K, has not been well characterized due in part to the corrosive nature of many of the working fluids, as well as the poor performance in many conventional metal envelope systems. Spacecraft nuclear electric propulsion, as well as other emerging technologies, can benefit from heat pipes with optimal performance in this intermediate regime. In this work, we have explored halide working fluids coupled with aluminum nitride shells to operate at 500-600 K and interface with a nuclear electric propulsion system. The shells have been additively manufactured and tested to ensure compatibility with the halides. Specifically, AlBr 3 , AlCl 3 , FeCl 3 , and SbBr 3 were selected owing to their higher performance and comparatively safe handling characteristics compared to other intermediate temperature working fluids. The additive manufacturing process enables highly customizable designs that integrate the heat pipe and radiator fin together, optimized for each fluid. We have evaluated the performance limits of such a heat pipe design in order to establish the feasibility of AlBr 3 in particular, and present design that achieves an areal density of 5.2 kg/m 2 and mass per unit heat performance of 0.71 kg/kW. Analysis is ongoing for all working fluids.

thermal management↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Development of a conduction-based model for analyzing frozen startup of alkali-metal heat pipes

One key area of interest in heat pipe modeling/simulation is to analyze the startup behavior of the liquid-metal heat pipes (LMHPs) from a frozen state. This so-called ‘frozen startup’ process involves a complex set of nonlinear mass and heat transport phenomena, including phase transitions from solid to liquid and vapor, multiphase interactions, microporous wick flow, and compressible vapor dynamics. The complexity of these processes makes it challenging to simulate LMHP’s frozen startup using conventional numerical methods or commercial computational fluid dynamics (CFD) software. This paper presents a simplified conduction-based modeling approach that can provide practical insights into the entire LMHP frozen startup process, while alleviating the challenges of modeling its complex physics. The theoretical foundation and physical assumptions of the proposed model are based solely on heat-conduction equation, allowing for a more tractable simulation without sacrificing essential physical accuracy. The proposed model was implemented in a commercial CFD software, and its prediction was compared with the experimental data obtained from sodium heat-pipe startup experiments. The comparison highlights the proposed model's ability to capture the transient thermal behavior of LMHP during frozen startup. This study not only validates the conduction-based frozen startup modeling method but also shows its potential as a practical and efficient tool for understanding the startup performance of the LMHP systems.

Microreactor↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Debonding Effect in Internal Replacement Pipe System Under Lateral Loading

The aging pipeline infrastructure around the world necessitates immediate rehabilitation. Internal replacement pipe (IRP) is a trenchless system offering a versatile and cost-effective solution across a variety of industries, including oil, natural gas, water, and wastewater. As a structural pipeline repair system, IRPs are subject to lateral deformation because of surface traffic loading. The present study evaluates the impact of adhesion between the host pipe and the IRP, with a focus on assessing the debonding effect on the behavior of the repair system under lateral deformation and bending. This was achieved using a comprehensive approach, including experimental, numerical, and analytical techniques. Varying levels of adhesive strength resulting from different methods of surface preparation were considered. The effectiveness of the IRP system on both discontinuous host pipes with various crack widths and continuous host pipes was also investigated. The results demonstrate that adhesive strength exerts a significant influence on the repair system, especially in the case of narrow circumferential cracks, while its impact on the continuous system is minimal. For optimal performance, it is essential to choose adhesives that possess sufficient shear strength while also accounting for the required debonding length. This approach ensures that minor discontinuities are effectively controlled, thereby enhancing the system′s fatigue life. The reliable determination of the maximum allowable shear strength for the adhesive or the debonding length can ensure that it does not negatively affect fatigue life. The findings presented in this study offer new insights into the development of trenchless repair techniques that can enhance system performance and extend service life.

Tien, Tri C. M.↗

Studies reveal effects of pipe bends on fluid flow cavitation

Incipient cavitation in liquids flowing in pipes curved in one plane are affected by the pipe bend radii and pipe diameters, but little by pipe bend angles ranging from 60 to 120 degrees. Critical cavitation indices decrease with higher Reynolds number and pressure ratio. Bulk liquid temperature increase lowers the mean critical velocity at which cavitation occurs.

Stonemetz, R. E.↗

Dynamics of heat-pipe reactors

A split-core heat pipe reactor, fueled with either U(233)C or U(235)C in a tungsten cermet and cooled by 7-Li-W heat pipes, was examined for the effects of the heat pipes on reactor while trying to safely absorb large reactivity inputs through inherent shutdown mechanisms. Limits on ramp reactivity inputs due to fuel melting temperature and heat pipe wall heat flux were mapped for the reactor in both startup and at-power operating modes.

Niederauer, G. F.↗