Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Purpose, Design, and Analysis of the NSTX-U Centerstack Casing Lateral Support Shims

The National Spherical Torus Experiment Upgrade (NSTX-U) centerstack casing surrounds the central magnet core of NSTXU. It provides the inner vacuum boundary of the plasma chamber and supports the radially inboard plasma facing components lining the plasma chamber. The casing is supported like a cantilever, fixed at the lower flange by a connection to the TF Bundle through a G-10 ring. It is flexibly supported at the top by bellows, and insulated shims intended to react the largest part of the inventory of the disruption loads at the upper support, thereby protecting the upper and lower connections from excessive loads. A large part of the qualification of the casing and tiles requires addressing and quantifying disruption loads. These have been estimated based on extensions of the behavior of NSTX during its run period roughly 15 years ago. Structural qualification of the Upgrade used these estimates of the loading as input to calculations to demonstrate adequacy for a “most probable” disruption. The estimates are included in a requirements document to guide conservative design of all components loaded by disruptions. However, the changes made for the upgrade made the extrapolation of disruption behavior uncertain. Disruptions include axisymmetric loading from axisymmetric currents induced in the vessel shells. In addition, more complex currents called Halo currents are a result of plasma poloidal currents impinging on the casing. The halo currents add another layer of uncertain behavior and net lateral loading to the casing. As a result, NSTX-U is equipped with a number of instruments intended to assess the nature and severity of disruptions. The casing shims are required for lateral support of the casing, but these have also been converted to load cells to provide another measure of the magnitude of symmetric and asymmetric loading. Some of the logic in the development of the requirements document are presented. Electromagnetic analysis of axisymmetric and halo loading is described. Global simulations of the casing transient dynamic response, and local analysis and testing of the shim/load cell are included. The shim load cells and other instrumentation will be an important guide in planning NSTX-U experiments beyond its next run period expected in late 2026 or early 2027.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton deflectometry with in situ x-ray reference for absolute measurement of electromagnetic fields in high-energy-density plasmas

In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

47 OTHER INSTRUMENTATION↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Evaluation of the Abel inversion integral in O-mode plasma reflectometry using Chebyshev–Gauss quadrature

The Abel transform is often used to reconstruct plasma density profiles from O-Mode polarized reflectometry diagnostics. However, standard numerical trapezoidal evaluation of the Abel inversion integral can be computationally expensive for a large number of evaluation points, and an endpoint singularity exists on the upper-bound of the integral, which can result in an increased error. In this work, Chebyshev–Gauss quadrature is introduced as a new method to evaluate the Abel inversion integral for the problem of O-Mode plasma reflectometry. Here, the method does not require numerical evaluation of an integral singularity and is shown to have similar accuracy compared to existing methods while being computationally efficient.

47 OTHER INSTRUMENTATION↗

Integration of full divertor detachment with improved core confinement for tokamak fusion plasmas

Divertor detachment offers a promising solution to the challenge of plasma-wall interactions for steady-state operation of fusion reactors. Here, we demonstrate the excellent compatibility of actively controlled full divertor detachment with a high-performance (β N ~ 3, H 98 ~ 1.5) core plasma, using high-β p (poloidal beta, β p > 2) scenario characterized by a sustained core internal transport barrier (ITB) and a modest edge transport barrier (ETB) in DIII-D tokamak. The high-β p high-confinement scenario facilitates divertor detachment which, in turn, promotes the development of an even stronger ITB at large radius with a weaker ETB. This self-organized synergy between ITB and ETB, leads to a net gain in energy confinement, in contrast to the net confinement loss caused by divertor detachment in standard H-modes. These results show the potential of integrating excellent core plasma performance with an efficient divertor solution, an essential step towards steady-state operation of reactor-grade plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Characterization of high-frequency waves in the Martian magnetosphere

Context.Various high-frequency waves in the vicinity of upper-hybrid and Langmuir frequencies are commonly observed in different space plasma environments. Such waves and fluctuations have been reported in the magnetosphere of the Earth, a planet with an intrinsic strong magnetic field. Mars has no intrinsic magnetic field and, instead, it possesses a weak induced magnetosphere, which is highly dynamic due to direct exposure to the solar wind. In the present paper, we investigate the presence of high-frequency plasma waves in the Martian plasma environment by making use of the high-resolution electric field data from the Mars Atmosphere and Volatile Evolution missioN (MAVEN) spacecraft. Aims.This study aims to provide conclusive observational evidence of the occurrence of high-frequency plasma waves around the electron plasma frequency in the Martian magnetosphere. We observe two distinct wave modes with frequency below and above the electron plasma frequency. The characteristics of these high-frequency waves are quantified and presented here. We discuss the generation of possible wave modes by taking into account the ambient plasma parameters in the region of observation. Methods.We have made use of the medium frequency (100 Hz–32 kHz) burst mode-calibrated electric field data from the Langmuir Probe and Waves instrument on board NASA’s MAVEN mission. Due to the weak magnetic field strength, the electron gyro-frequency is much lower than the electron plasma frequency, which implies that the upper-hybrid and Langmuir waves have comparable frequencies. A total of 19 wave events with wave activities around electron plasma frequency were identified by examining high-resolution spectrograms of the electric field. Results.These waves were observed around 5 LT when MAVEN crossed the magnetopause boundary and entered the magnetosheath region. These waves are either a broadband- or narrowband-type with distinguishable features in the frequency domain. The narrowband-type waves have spectral peak above the electron plasma frequency. However, in the case of broadband-type waves, the spectral peak always occurred below the electron plasma frequency. The broadband waves consistently show a periodic modulation of 8–14 ms. Conclusions.The high-frequency narrowband-type waves observed above the electron plasma frequency are believed to be associated with upper-hybrid or Langmuir waves. However, the physical mechanism responsible for the generation of broadband-type waves and the associated 8–14 ms modulation remain unexplained and further investigation is required.

Astronomy & Astrophysics↗

A review of instrument techniques to measure magnetospheric cold electrons and ions

A review of the instruments and techniques to directly measure the full distributions of the cold-ion and cold-electron populations in the magnetosphere is presented. Relatively few studies have focused on the cold plasma populations of the magnetosphere due to difficulties associated with obtaining measurements. The cold particle populations are defined here as those with total energy approximately <100 eV which is an energy range for which measurements are difficult (regardless of species), but which often make up the bulk of the plasma density. These populations have known and suspected impacts on the structure and dynamics of the magnetosphere but to date have not yet been measured adequately. The lack of accurate measurements cold ion and electron populations through the magnetosphere makes closure of these science questions extremely difficult if not impossible. Reaching closure will require innovations in plasma spectrometers and associated techniques required to obtain high-fidelity measurements of the cold ion and electron populations in the magnetosphere. This paper seeks to review the instruments and techniques that have been used to date and present possible options for future missions.

79 ASTRONOMY AND ASTROPHYSICS↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

K-shell radiation and bright spot characteristics of high-energy-density Fe-Cr-Ni plasmas influenced by X-pinch load geometry

K-shell radiation is diagnostically advantageous for the study of high-energy-density plasmas. Here, the current work investigates the influence of load geometry on K-shell x-rays in Z-pinch plasmas produced on the 1-MA Zebra generator. Stainless steel (Fe: 69%, Cr: 20%, Ni: 9%) X-pinch wire loads are fielded with an interwire angle of 31° (small-angle) or 62.5° (large-angle), respectively and studied using various x-ray diode, imaging, and spectroscopic diagnostics. The large-angle geometry produced large, individual x-ray-emitting bright spots (> 3 keV) at the wire cross-point averaging areas ≥ 1 mm 2 , with noteworthy soft x-ray (> 0.75 keV) bursts and radiation yields ≤ 14.6 kJ. The small-angle geometry produced multiple x-ray-emitting bright spots extending the pinch axis with smaller average sizes (≤ 0.5 mm 2 ), consistent with stronger current, increased radiation yield (≥ 15.5 kJ), and notable hard x-ray (> 9 keV) bursts, which peak with largest cumulative bright spot size. Spectroscopic analysis is performed with non-LTE collisional-radiative modeling, indicating a cold, nonthermal plasma region radiating from neutral to Ne-like ions, a hot, thermal region radiating from Fe and Cr He- and Li-like ions, and an intermediate region radiating Kα satellites from Li-like to O-like ions. Modeling of the nonthermal and satellite features imply a fractional hot electron abundance ~0.1% and ~0.5% for large- and small-angle geometries, respectively. Relative intensity analysis is performed on Heα and Kα lines, revealing intensity ratios that deviate from the original wire composition. Optical depth estimates allude to optically thick, thermal K-shell plasmas with densities consistent with non-LTE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructions from randomly generated longitudinal electron bunch profiles with Gaussian envelopes using the Gerchberg–Saxton algorithm

Knowledge of longitudinal electron bunch profiles is vital to optimize the performance of plasma wakefield accelerators and x-ray free electron laser linacs. Because of their importance to these novel applications, noninvasive frequency domain techniques are often employed to reconstruct longitudinal bunch profiles from coherent synchrotron, transition, or undulator radiation measurements. In this paper, we detail several common reconstruction techniques involving the Kramers–Kronig phase relationship and Gerchberg–Saxton algorithm. Additionally, through statistical analysis, we draw general conclusions about the accuracy of these reconstruction techniques and the most suitable candidate for reconstructing well-isolated longitudinal bunch profiles from spectroscopic data.

47 OTHER INSTRUMENTATION↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗