Search NASA⌕ Search

SEARCH · Search NASA

Results for “power cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.↗

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Brayton-cycle heat exchanger technology program

The following five tasks designed to advance this development of heat exchanger systems for close loop Brayton cycle power systems are presented: (1) heat transfer and pressure drop data for a finned tubular heat transfer matrix. The tubes are arranged in a triangular array with copper stainless steel laminate strips helically wound on the tubes to form a disk fin geometry; (2) the development of a modularized waste heat exchanger. Means to provide verified double containment are described; (3) the design, fabrication, and test of compact plate fin heat exchangers representative of full scale Brayton cycle recuperators; (4) the analysis and design of bellows suitable for operation at 1600 F and 200 psia for 1,000 cycles and 50,000 hours creep life; and (5) screening tests used to select a low cost braze alloy with the desirable attributes of a gold base alloy. A total of 22 different alloys were investigated; the final selection was Nicrobraz 30.

Killackey, J. J.↗

Pilot Injector Redesign to Reduce N+3 Cycle Emissions for a Gas-Turbine Combustor

An overview is given of an effort for the use of CFD analysis to complement design and configuration definition of third generation Lean-Direct Injection combustion concepts (LDI-3) for NASA’s N+3 program. The National Combustion Code (OpenNCC) was used to perform non-reacting and two-phase reacting flow computations for a three-cup, nineteen-element flame tube array with redesigned pilot injectors to improve spray and emissions characteristics when compared to a previous LDI-3 design. All computations were performed with a consistent approach to mesh-generation, spray modeling, ignition and kinetics modeling for a ‘medium-power’ cycle condition. Computational predictions of the aerodynamics of a new pre-filming pilot injector were used to arrive at an optimized aerothermal design that meets effective area and fuel-air mixing criteria. The newly designed pilot injectors were shown to provide considerable improvements in aerodynamic stability, flame-tube pattern factor and NOx emissions, when compared to the original design.

nitrogen oxides injectors↗

Pilot Injector Redesign to Reduce N+3 Cycle Emissions for a Gas-Turbine Combustor

An overview is given of an effort for the use of CFD analysis to complement design and configuration definition of third generation Lean-Direct Injection combustion concepts (LDI-3) for NASA's N plus 3 program. The National Combustion Code (OpenNCC) was used to perform non-reacting and two-phase reacting flow computations for a three-cup, nineteen-element flametube array with redesigned pilot injectors to improve spray and emissions characteristics when compared to a previous LDI-3 design. All computations were performed with a consistent approach to mesh-generation, spray modeling, ignition and kinetics modeling for a "medium-power" cycle condition. Computational predictions of the aerodynamics of a new pre-filming pilot injector were used to arrive at an optimized aerothermal design that meets effective area and fuel-air mixing criteria. The newly designed pilot injectors were shown to provide considerable improvements in aerodynamic stability, flame-tube pattern factor and NOx emissions, when compared to the original design.

Nitrogen Oxides↗

Development of a thermal storage module using modified anhydrous sodium hydroxide

The laboratory scale testing of a modified anhydrous NaOH latent heat storage concept for small solar thermal power systems such as total energy systems utilizing organic Rankine systems is discussed. A diagnostic test on the thermal energy storage module and an investigation of alternative heat transfer fluids and heat exchange concepts are specifically addressed. A previously developed computer simulation model is modified to predict the performance of the module in a solar total energy system environment. In addition, the computer model is expanded to investigate parametrically the incorporation of a second heat exchange inside the module which will vaporize and superheat the Rankine cycle power fluid.

Rice, R. E.↗

Testing of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers for Space Applications

Thermal performance of a miniature loop heat pipe (MLHP) with two evaporators and two condensers is described. A comprehensive test program, including start-up, high power, low power, power cycle, and sink temperature cycle tests, has been executed at NASA Goddard Space Flight Center for potential space applications. Experimental data showed that the loop could start with heat loads as low as 2W. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of l00W to 120W, and could recover from a dry-out by reducing the heat load to evaporators. Low power test results showed the loop could work stably for heat loads as low as 1 W to each evaporator. Excellent adaptability of the MLHP to rapid changes of evaporator power and sink temperature were also demonstrated.

Nagano, Hosei↗

Apparent luminosity of solar power satellites

The objective of this investigation was a quantitative characterization of solar power satellite luminosity as seen from the earth. The reflective characteristics of the reference photovoltaic satellite configurations are defined. Diffuse reflection from a single satellite will, at maximum, fall between magnitudes -4 and -5. A 60-satellite fleet will have a maximum total luminosity equivalent to a single object of magnitude -9. Specular reflections from the array and antenna will be of magnitude -12 to -15, but visible only occasionally for about 2 minutes at a given location. Methods of preventing specular reflections from striking the earth are presented. Thermal cycle power conversion systems are discussed qualitatively as a means of reducing diffuse luminosity.

Livingston, L. E.↗

Design and Optimization of a 3-Stage Axial Supercritical CO2 Compressor

This paper presents the detailed design and optimization of a three-stage axial supercritical carbon dioxide (sCO2) compressor to support the advancement of sCO 2 power cycles, recognized for their efficiency and compactness in energy conversion. The three-stage design is a scaled model of the original nine-stage 100 MW design. The aerodynamic design and structural analysis were performed at the University of Cincinnati, and the results are presented. The first stage of the design has been meticulously manufactured and experimentally tested at University of Notre Dame Turbomachinery Laboratory. The design process starts with the preliminary design process, considering the required operating boundary conditions and geometrical constraints for full stage design. The design is then scaled down to 3-stage based on the power limitation. The definition for design parameters has been inspired from the EEE HPC design and tweaked to fit the sCO 2 operation. Axisymmetric analysis is performed next and the parametric geometry modeler -Tblade3 has been used to create 3D blade geometry from the results which can then be exported for the 3D CFD analysis and optimization. An efficiency of 89.85% is predicted for the final design at the design point.

Compressor↗

Active Control of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

The operating temperature of a loop heat pipe (LHP) with multiple evaporators is a function of the total heat load, heat load distribution among evaporators, condenser temperature and ambient temperature. Because of the many variables involved, the operating temperature also showed more hystereses than an LHP with a single evaporator. Tight temperature control can be achieved by controlling its compensation chamber (CC) temperatures at the desired set point. This paper describes a test program on active control of the operating temperature in an LHP with two evaporators and two condensers. Temperature control was achieved by heating one or both CC's. Tests performed included start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results show that, regardless one or two CC's were heated to the set point temperature, one of CC's was always flooded with liquid. The loop could operate successfully at the desired set point temperature under most conditions, including some fast transients. At low heat loads, however, the CC temperature could suddenly increase above the set point temperature, possibly due to a sudden change of the vapor content inside the evaporator core.

Ku, Jentung↗

Transient Simulation of the Integrated Powerhead Demonstrator (IPD) Rocket Engine

The IPD rocket engine is the product of a joint Air Force/NASA program to demonstrate the concept of a full-flow staged combustion power cycle. In this type of rocket engine cycle, both the entire fuel flow and the entire oxidizer flow are combusted in one of two pre-bumers and used to drive two turbopumps, thus utilizing the flow work of the total propellant flow. The basis of the IPD engine program relies on integrating newly developed and pre-existing hardware to demonstrate the component and material technologies to make this concept feasible, while simultaneously saving development time and costs. To provide insight to the project team and contractors during engine development and test phases, the engine system was modeled at MSFC using the Rocket Engine Transient Simulation (ROCETS) software to analyze system performance and determine component integration issues. The ROCETS software is used extensively a MSFC to perform steady-state power-balances and transient simulations of thermodynamic power and general fluid systems. The software is favored for its capability to solve large systems of non-linear equations, its librarie of fluid properties and flow devices, its flexibility to modify existing code to improve the physics-derived approximations of real fluid thermodynamic behavior, and the ability to add unique system constraints. The purpose of this paper is to present the methodology used to model the IPD engine system, detail the pitfalls encountered with the software, and explain the approximations made to more accurately represent engine component and fluid behavior. Engine system performance output from the model will be presented and explained in comparison with real fluid and component behavior.

Guidos, Mike↗

Prognostics Approach for Power MOSFET Under Thermal-Stress

The prognostic technique for a power MOSFET presented in this paper is based on accelerated aging of MOSFET IRF520Npbf in a TO-220 package. The methodology utilizes thermal and power cycling to accelerate the life of the devices. The major failure mechanism for the stress conditions is dieattachment degradation, typical for discrete devices with leadfree solder die attachment. It has been determined that dieattach degradation results in an increase in ON-state resistance due to its dependence on junction temperature. Increasing resistance, thus, can be used as a precursor of failure for the die-attach failure mechanism under thermal stress. A feature based on normalized ON-resistance is computed from in-situ measurements of the electro-thermal response. An Extended Kalman filter is used as a model-based prognostics techniques based on the Bayesian tracking framework. The proposed prognostics technique reports on preliminary work that serves as a case study on the prediction of remaining life of power MOSFETs and builds upon the work presented in [1]. The algorithm considered in this study had been used as prognostics algorithm in different applications and is regarded as suitable candidate for component level prognostics. This work attempts to further the validation of such algorithm by presenting it with real degradation data including measurements from real sensors, which include all the complications (noise, bias, etc.) that are regularly not captured on simulated degradation data. The algorithm is developed and tested on the accelerated aging test timescale. In real world operation, the timescale of the degradation process and therefore the RUL predictions will be considerable larger. It is hypothesized that even though the timescale will be larger, it remains constant through the degradation process and the algorithm and model would still apply under the slower degradation process. By using accelerated aging data with actual device measurements and real sensors (no simulated behavior), we are attempting to assess how such algorithm behaves under realistic conditions.

Power MOSFET PHM↗

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

Most existing Loop Heat Pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators will be very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the LHP technology to include multiple evaporators and multiple condensers faces some challenges, including the interaction between individual compensation chambers, operating temperature stability, and adaptability to rapid power and sink temperature transients. This paper describe extensive testing of an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, reservoir temperature cycle, and capillary limit. Test results showed that the loop could operate successfully under various heat load and sink conditions. The loop operating temperature is a function of the total heat load, the heat load distribution between the two evaporators, and temperatures of the two condenser sinks. Under most conditions, only one reservoir contained two-phase fluid and the other reservoir was completely liquid filled. Moreover, control of the loop operating temperature could shift from one reservoir to the other as the test condition changed.

Ku, Jentung↗

Resistance of Silicon Nitride Turbine Components to Erosion and Hot Corrosion/oxidation Attack

Silicon nitride turbine components are under intensive development by AlliedSignal to enable a new generation of higher power density auxiliary power systems. In order to be viable in the intended applications, silicon nitride turbine airfoils must be designed for survival in aggressive oxidizing combustion gas environments. Erosive and corrosive damage to ceramic airfoils from ingested sand and sea salt must be avoided. Recent engine test experience demonstrated that NT154 silicon nitride turbine vanes have exceptional resistance to sand erosion, relative to superalloys used in production engines. Similarly, NT154 silicon nitride has excellent resistance to oxidation in the temperature range of interest - up to 1400 C. Hot corrosion attack of superalloy gas turbine components is well documented. While hot corrosion from ingested sea salt will attack silicon nitride substantially less than the superalloys being replaced in initial engine applications, this degradation has the potential to limit component lives in advanced engine applications. Hot corrosion adversely affects the strength of silicon nitride in the 850 to 1300 C range. Since unacceptable reductions in strength must be rapidly identified and avoided, AlliedSignal and the NASA Lewis Research Center have pioneered the development of an environmental life prediction model for silicon nitride turbine components. Strength retention in flexure specimens following 1 to 3300 hour exposures to high temperature oxidation and hot corrosion has been measured and used to calibrate the life prediction model. Predicted component life is dependent upon engine design (stress, temperature, pressure, fuel/air ratio, gas velocity, and inlet air filtration), mission usage (fuel sulfur content, location (salt in air), and times at duty cycle power points), and material parameters. Preliminary analyses indicate that the hot corrosion resistance of NT154 silicon nitride is adequate for AlliedSignal's initial engine applications. Protective coatings and/or inlet air filtration may be required to achieve required ceramic component lives in more aggressive environments.

Strangmen, Thomas E.↗