Long-run Marginal Emission Rates for Electricity - Workbooks for 2021 Cambium Data

These workbooks contain modeled estimates of long-run marginal emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical demand. It incorporates both the projected changes to the electric grid, as well as the potential for an incremental change in electrical demand to influence the structural evolution of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treats grid assets as fixed. The Levelized LRMER worksheet within each workbook is set up to produce a levelized long-run marginal emission rate based on user-provided inputs. These levelized LRMER values are intended for analysts to use when estimating the emissions induced (or avoided) by a long-term change in end-use electricity demand. There are two workbooks that supply the data at two different geographic resolutions: states and GEA regions (20 regions that are similar to, but not exactly the same as, the US EPA's eGRID regions). For more data underlying these emissions factors, see the Cambium 2021 project at https://cambium.nrel.gov/. For more details on the inputs into the scenarios available in the workbooks, see the Standard Scenarios 2021 Report (https://www.nrel.gov/docs/fy22osti/80641.pdf). This data was produced as part of the Cambium project. For more details about the methodology, see the Cambium Documentation: Version 2021 (https://www.nrel.gov/docs/fy22osti/81611.pdf). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nrel.gov/analysis/cambium.html.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of equitable resilience metrics into climate-informed electric utility planning processes: phase one

Working together, Sandia National Laboratories, Southern California Edison (SCE) - an Investor-Owned Utility (IOU) - and the California Public Utilities Commission (CPUC) are studying how electric utilities can use equity and resilience metrics to help inform the prioritization and sequencing of resilience-driven infrastructure investments. To this end, this project evaluated “Social Burden,” an equitable resilience metric which measures the potential impact of disruptions in access to non-electric critical services on people and estimates community resilience to these disruptions. The Social Burden was expanded to incorporate SCE’s existing equity metric and applied to evaluate the potential impacts from a range of climate-informed hypothetical outage scenarios developed under SCE’s 2022 Climate Adaptation Vulnerability Assessment. One baseline (“blue-sky”) state and eight different outage scenarios were evaluated to measure the potential impacts of the outages on non-electric infrastructure, critical services, and people. Key findings include: 1) the Social Burden framework is flexible enough to adapt to and build upon existing utility equity and/or resilience metrics, 2) Social Burden results highlight the high degree of non-electric service redundancy within the SCE service area with most (6/8) hypothetical outage scenarios predicted to increase people’s Social Burden by less than 10%; however, 3) access to critical services and people’s ability to obtain them is unequal and spatially clustered, meaning that there are some hypothetical outage scenarios (2/8) that will exert a higher toll on communities directly experiencing the outage as well as some nearby communities with pre-existing vulnerabilities. The report concludes with recommendations for potential use cases of the expanded Social Burden metric and identifies priority follow-on work. Potential use cases may include incorporating equity into IOU’s prioritization of climate resilience investments. Additionally, Social Burden analysis may provide additional data and insights to augment grid planning, potentially by identifying additional needs and/or prioritizing previously identified needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NARUC Resilience Framework

The NARUC Resilience Framework provides state regulators and other key stakeholders with a structured approach to considering policies and programs that will enhance grid resilience amid evolving technological, environmental and economic challenges. This Framework consolidates insights from nationwide workshops and peer discussions into six actionable components: (1) setting goals and objectives, (2) leveraging use cases, (3) establishing shared definitions, (4) ensuring inclusive process leadership, (5) addressing critical design questions, and (6) guiding implementation. This Framework is intended as a strategic tool for regulators to navigate resilience investments, prioritize affordability, integrate stakeholder needs, and foster collaboration across agencies, all while balancing cost-effectiveness with societal and economic resilience outcomes. By presenting a structured approach to decision-making rather than prescriptive solutions, the Framework supports nuanced, jurisdiction-specific resilience planning and is adaptable to the dynamic demands of modern energy systems

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-run Marginal CO2 Emission Rates Workbooks for 2020 Standard Scenarios Cambium Data

This dataset has been superseded by a new set of workbooks that can be found here: https://data.nlr.gov/submissions/183 These workbooks contain modeled estimates of long-run marginal CO2 emission rates (LRMER) for the contiguous United States. The LRMER is an estimate of the rate of emissions that would be either induced or avoided by a long-term (i.e., more than several years) change in electrical demand. It incorporates both the projected changes to the electric grid, as well as the potential for an incremental change in electrical demand to influence the structural evolution of the grid (i.e., the building and retiring of capital assets, such as generators and transmission lines). It is therefore distinct from the more-commonly-known short-run marginal, which treats grid assets as fixed. In addition to year-over-year data, the Levelized LRMER worksheet within each workbook is set up to produce a levelized long-run marginal emission rate based on user-provided inputs. These levelized LRMER values are intended for analysts to use when estimating the emissions induced (or avoided) by a long-term change in end-use electricity demand. Three future scenarios are provided in separate workbooks: A Mid-case (i.e., business-as-usual), and two scenarios with relatively higher or lower renewable energy costs. For more details on these scenarios, see the Standard Scenarios 2020 Report ( https://www.nlr.gov/docs/fy21osti/77442.pdf ). For more data underlying each scenario, see the Standard Scenarios 2020 project (Cambium data) at https://cambium.nlr.gov/ . This data was produced as part of the Cambium project. For more details about the methodology, see the Cambium Documentation: Version 2020 ( https://www.nlr.gov/docs/fy21osti/78239.pdf ). This data is planned to be updated annually. Information on the latest versions can be found at https://www.nlr.gov/analysis/cambium.html .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Providencia Island White Papers: Overview of Technical Requirements for Interconnection

This issue brief provides an overview of key technical requirements for inverter-based resources - including distributed energy resources (DERs) - to support the reliable and safe operation of the Providencia Island electrical grid, and other island or isolated area mini-grid applications. With the planned increase in inverter-based resources and the introduction of energy storage, adopting Institute of Electrical and Electronics Engineers (IEEE) Std 1547-2018, including the more advanced performance capabilities for voltage and frequency ride-through, will simplify interconnection as well as help to maintain a safe, reliable grid on Providencia Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Energy Finance Training [Slides]

The Energy 101: Energy Financing Training presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of energy project financing. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Assistance for the Makah Tribe, Washington

The Energy Technology Innovation Partnership Project (ETIPP) worked with the Makah Tribe on strategic energy planning, including scoping future energy needs of relocated facilities, understanding the potential for new energy generation options to support current and future energy demand, and supporting communication and capacity-building goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Electric Grid, Distributed Generation, and Grid Interconnection

This fact sheet is part of the Community Planning for Solar toolkit designed to help Massachusetts municipalities and others proactively plan for solar development in their communities. This fact sheet will walk you through the electricity system, and help you understand how the grid is changing as distributed generation (DG) electricity sources become more common.

14 SOLAR ENERGY↗

Role of Renewable Energy, Storage, and Demand Response in Karnataka's Power Sector Future

Karnataka ranks fourth among Indian states in installed capacity of renewable energy, which accounts for over 50% of its resource mix. The state is positioned to play a leading role in India's energy transition and contribute to meeting national targets for renewable energy thanks, in part, to ambitious state goals to develop Karnataka's abundant zero carbon energy resources and plans to phase out new investments in thermal plants. Power system stakeholders in Karnataka are faced with the challenge of planning a generation portfolio that accounts for the variability of wind and solar resources, meets increasing and shifting electricity demand, and satisfies operational and reliability requirements. The objective of this study is to evaluate least-cost pathways for Karnataka's electric power system through 2050. The capacity expansion model developed for this study identifies power system investment and operational decisions for every year (2020-2050) for all of India, with detailed representation of the state of Karnataka. The study led to five high-level results and provides a framework for recurring planning studies to meet changing system conditions and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Distributed Energy Storage Sizing in Puerto Rico: Leveraging Increased Distributed Generation for Enhanced Resilience

Distributed solar photovoltaic (PV) and battery energy storage systems (BESS) adoption has increased rapidly in Puerto Rico since Hurricane Maria in 2017 as customers seek local resilient energy solutions. To investigate how to best leverage these many distributed PV and BESS systems, in this paper, we introduce a modeling framework that can be used by entities planning resilience investments to provide insights about the sizing and operational needs to achieve desired resilience benefits.

24 POWER TRANSMISSION AND DISTRIBUTION↗