Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system dynamic stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Electromagnetic Transient and Phasor Dynamic Simulations: Implications for Inverter Dominated Systems

The simulation of very high shares of inverter-based resources in power systems has begun to draw into question the validity of phasor domain tools in capturing relevant dynamics. Electromagnetic transient simulators can capture the dynamics of power electronics with substantially smaller time steps, but are computationally expensive. This work contrasts the results of phasor domain and electromagnetic transient tools for simulations on a validated model of the Maui power system operating at very high inverter-based resource shares with near zero voltage forming devices. The results show that the phasor domain tool predicts optimistic stability with fewer voltage forming elements on the network, and loses computational stability before the electromagnetic transient tool. As the electromagnet transient model is of the entire system, and system-wide discrepancies are observed, this case study of a physical power system highlights the potential need for system-wide detailed modeling during periods of very high shares of inverter-based resources and few voltage forming devices.

electromagnetic transient-domain↗

Modified Andronov-Hopf Oscillator-Based Grid-Forming Converter with Emulated Virtual Cable for Enhanced Power Sharing Performance

Nonlinear oscillator-based grid-forming converters offer superior dynamic and steady-state performance, making them an attractive solution for interconnecting renewable resources. This paper proposes a novel modified Andronov-Hopf oscillator to enhance the operating spectrum and facilitate the integration of renewable energy sources. An inner loop controller based on the Lyapunov energy function is implemented to achieve robust stability and performance, while a virtual cable emulation strategy enables seamless parallel operation. Comprehensive modeling and simulation studies validate the effectiveness of the proposed system, demonstrating its capabilities in addressing diverse operating scenarios, including grid faults, renewable energy fluctuations, and parallel operation. The proposed solution exhibits fast transient response, robust stability, and flexible operation, making it a valuable contribution to the field of renewable energy integration. The results of this study can be used to inform the design and implementation of next-generation grid-forming converters, enabling a more sustainable and reliable energy future. Additionally, the proposed system's ability to operate in both grid-connected and islanded modes makes it an ideal candidate for remote and off-grid renewable energy applications. The proposed solution's scalability and modularity also make it suitable for large-scale renewable energy integration. The proposed system is verified through MATLAB/Simulink and PLECS simulations, demonstrating its effectiveness in ensuring robust and efficient operation.

Andronov-Hopf Oscillator (AHO)↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow: Preprint

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires a networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Modeling and Detection of Future Cyber-Enabled DSM Data Attacks

Demand-Side Management (DSM) is an essential tool to ensure power system reliability and stability. In future smart grids, certain portions of a customer’s load usage could be under the automatic control of a cyber-enabled DSM program, which selectively schedules loads as a function of electricity prices to improve power balance and grid stability. In this scenario, the security of DSM cyberinfrastructure will be critical as advanced metering infrastructure and communication systems are susceptible to cyber-attacks. Such attacks, in the form of false data injections, can manipulate customer load profiles and cause metering chaos and energy losses in the grid. The feedback mechanism between load management on the consumer side and dynamic price schemes employed by independent system operators can further exacerbate attacks. To study how this feedback mechanism may worsen attacks in future cyber-enabled DSM programs, we propose a novel mathematical framework for (i) modeling the nonlinear relationship between load management and real-time pricing, (ii) simulating residential load data and prices, (iii) creating cyber-attacks, and (iv) detecting said attacks. In this framework, we first develop time-series forecasts to model load demand and use them as inputs to an elasticity model for the price-demand relationship in the DSM loop. This work then investigates the behavior of such a feedback loop under intentional cyber-attacks. We simulate and examine load-price data under different DSM-participation levels with three types of random additive attacks: ramp, sudden, and point attacks. We conduct two investigations for the detection of DSM attacks. The first studies a supervised learning approach, with various classification models, and the second studies the performance of parametric and nonparametric change point detectors. Results conclude that higher amounts of DSM participation can exacerbate ramp and sudden attacks leading to better detection of such attacks, especially with supervised learning classifiers. We also find that nonparametric detection outperforms parametric for smaller user pools, and random point attacks are the hardest to detect with any method.

97 MATHEMATICS AND COMPUTING↗

Efficient Simulation of Cascading Outages Using an Energy Function-Embedded Quasi-Steady-State Model

Here, this paper proposed an energy function-embedded quasi-steady-state model for efficient simulation of cascading outages on a power grid while addressing transient stability concerns. Compared to quasi-steady-state models, the proposed model incorporates short-term dynamic simulation and an energy function method to efficiently evaluate the transient stability of a power grid together with outage propagation without transient stability simulation. Cascading outage simulation using the proposed model conducts three steps for each disturbance such as a line outage. First, it performs time-domain simulation for a short term to obtain a post-disturbance trajectory. Second, along the trajectory, the system state with the local maximum potential energy is found and used as the initial point to search for a relevant unstable equilibrium by Newton's method. Third, the transient energy margin is estimated based on this unstable equilibrium to predict an out-of-step condition with generators. The proposed energy function-embedded quasi-steady-state model is tested in terms of its accuracy and time performance on an NPCC 140-bus power system and compared to a quasi-steady-state model embedding transient stability simulation.

Guo, Zhenping [Univ. of Tennessee, Knoxville, TN (↗

EXPERIMENTAL STUDIES OF NONLINEAR INTEGRABLE OPTICS

State-of-the-art accelerators at energy and intensity frontiers require increasingly bright and powerful particle beams. In conventional linear lattices, intense beams suffer from collective instabilities, resulting in beam losses and maximum beam intensity limits. This thesis presents experimental studies of a novel lattice design concept, the nonlinear integrable optics (NIO), aimed at enhancing beam stability limits with little to no beam dynamics degradation. Single-particle beam dynamics measurements of two NIO devices, the quasi-integrable octupole system and the fully integrable Danilov-Nagaitsev system, were carried out at the purpose-built Integrable Optics Test Accelerator (IOTA) at Fermilab. Their simulation, hardware design, and commissioning process are presented. Extensive model and analysis algorithm development and benchmarking is described. Electron beam data from two scientific runs is analyzed, yielding frequency and phase space dynamics consisten t with m odels. These results demonstrate viability and advantages of the NIO design, providing the groundwork for proton studies in the strong space-charge regime and future integrable accelerators.

Kuklev, Nikita↗

A Trade-Off Study Between the Primary and Transient Responses of Grid-Forming Inverters

The control parameters of the grid-forming (GFM) inverter-based resources (IBRs) directly impact power system dynamics. The primary control requires the GFM inverter to balance generation and load. It is also preferred that a GFM inverter maintain the terminal frequency after a power system fault. In this paper, we investigate the trade-off between the primary control objective and the transient response. To quantify the transient performance of the GFM inverter, we introduce a new real-time transient stability index (TSI). This index plays a crucial role in our investigation, as it allows us to compare the performance trade-offs of different sets of GFM control parameters.

Lin, Xuheng↗

Designing open quantum systems with known steady states: Davies generators and beyond

We provide a systematic framework for constructing generic models of nonequilibrium quantum dynamics with a target stationary (mixed) state. Our framework identifies (almost) all combinations of Hamiltonian and dissipative dynamics that relax to a steady state of interest, generalizing the Davies’ generator for dissipative relaxation at finite temperature to nonequilibrium dynamics targeting arbitrary stationary states. We focus on Gibbs states of stabilizer Hamiltonians, identifying local Lindbladians compatible therewith by constraining the rates of dissipative and unitary processes. Moreover, given terms in the Lindbladian not compatible with the target state, our formalism identifies the operations – including syndrome measurements and local feedback – one must apply to correct these errors. Our methods also reveal new models of quantum dynamics: for example, we provide a “measurement-induced phase transition” in which measurable two-point functions exhibit critical (power-law) scaling with distance at a critical ratio of the transverse field and rate of measurement and feedback. Time-reversal symmetry – defined naturally within our formalism – can be broken both in effectively classical and intrinsically quantum ways. Our framework provides a systematic starting point for exploring the landscape of dynamical universality classes in open quantum systems, as well as identifying new protocols for quantum error correction.

Guo, Jinkang [Department of Physics and Center for↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Dynamic Model Development of a Wind Power Plant Using Neural Net Method to Forecast Wind Power Output (CRADA Final Report)

This project is intended to model wind power plant based on monitored data at the wind power plant. This project will promote the university research in Renewable Energy area and trains the future highly qualified engineers. The dynamic model will be based on neural net model with the input from the two met towers (12 inputs), and the number of turbines in operation (one input). The overall input will be 13 inputs to drive the simulations. The output power at the point of interconnection will be used to tune the neural net weight coefficients. Two neural net concepts will be investigated (the back propagation neural net and the dynamic recurrent neural net with feedback).

17 WIND ENERGY↗

Dynamic land use implications of rapidly expanding and evolving wind power deployment

Abstract The expansion of wind power poses distinct and varied geographic challenges to a sustainable energy transition. However, current knowledge of its land use impacts and synergies is limited by reliance on static characterizations that overlook the role of turbine technology and plant design in mediating interactions with the environment. Here, we investigate how wind technology development and innovation have shaped landscape interactions with social and ecological systems within the United States and contribute to evolving land area requirements. This work assesses trends in key land use facets of wind power using a holistic set of metrics to establish an evidence base that researchers, technology designers, land use managers, and policymakers can use in envisioning how future wind-intensive energy systems may be jointly optimized for clean energy, social, and environmental objectives. Since 2000, we find dynamic land occupancy patterns and regional trends that are driven by advancing technology and geographic factors. Though most historical U.S. wind deployment has been confined to the temperate grassland biome in the nation’s interior, regional expansion has implicated diverse land use and cover types. A large percentage of the typical wind plant footprint (∼96% to > 99%) is not directly impacted by permanent physical infrastructure, allowing for multiple uses in the spaces between turbines. Surprisingly, turbines are commonly close to built structures. Moreover, rangeland and cropland have supported 93.4% of deployment, highlighting potential synergies with agricultural lands. Despite broadly decreasing capacity densities, offsetting technology improvements have stabilized power densities. Land use intensity, defined as the ratio of direct land usage to lifetime power generation of wind facilities, has also trended downwards. Although continued deployment on disturbed lands, and in close proximity to existing wind facilities and other infrastructure, could minimize the extent of impacts, ambitious decarbonization trajectories may predispose particular biomes to cumulative effects and risks from regional wind power saturation. Increased land-use and sustainability feedback in technology and plant design will be critical to sustainable management of wind power.

17 WIND ENERGY↗

First-Principles Studies on Sc 2 RuZ (Z = Si, Ge, Sn) Inverse Heusler Alloys: Structural, Electronic, and Transport Properties

The continuous demand for efficient, nontoxic, and thermally stable materials for room-temperature energy conversion motivates the exploration of novel thermoelectric systems beyond the traditional magnetic Heusler alloys. While full and half-Heusler compounds, especially Co-, Ni-, and Mn-based systems, have demonstrated promising thermoelectric properties, their typically high operating temperatures and magnetic complexities limit their applicability in ambient thermal management. In this context, we investigate whether Sc-based inverse Heusler alloys can offer a viable nonmagnetic alternative with competitive thermoelectric performance. In this work, we perform a systematic first-principles study of the inverse Heusler compounds Sc 2 RuZ (Z = Si, Ge, Sn), focusing on their structural, electronic, mechanical, and thermodynamic-thermoelectric properties. Density Functional Theory (DFT) was employed to compute optimized lattice structures and band dispersion, while dynamical stability was assessed via phonon calculations. Thermoelectric transport coefficients, including Seebeck coefficient, electrical conductivity, and thermal conductivity, were estimated using the semiclassical Boltzmann transport theory within the constant relaxation time approximation. Our results show that all Sc 2 RuZ compounds are thermodynamically stable semiconductors with indirect band gaps of 0.12–0.16 eV and exhibit high elastic moduli, especially Sc 2 RuSn, which demonstrates superior stiffness and incompressibility. Importantly, all compounds display promising room-temperature thermoelectric characteristics, including high Seebeck coefficients and power factors. These findings reveal that Sc 2 RuZ alloys represent a rare class of stable, nonmagnetic inverse Heusler semiconductors with intrinsic thermoelectric potential at room temperature, unlike many existing Heusler systems optimized for spintronics or high-temperature operation. This work expands the known design space for Heusler-based thermoelectrics and offers a theoretical basis for experimental realization of efficient, low-temperature, nonmagnetic thermoelectric materials.

alloys↗

Adaptive critic design-based reinforcement learning approach in controlling virtual inertia-based grid-connected inverters

In this report, an adaptive critic design (ACD) approach is proposed to control the phase and voltage of a grid-connected virtual synchronous generator (VSG). The penetration of fast responding inertia-less power converters significantly affect the stability of the power system, especially weak systems such as micro grids. The concept of virtual inertia addresses this concern by virtually emulating the behavior of a synchronous generator. However, the conventional VSG is designed based on two conditions: (i) fixed operating point and (ii) inductive grid connections. The performance of VSGs in low-voltage semi-resistive microgrids is far from optimal. To overcome the aforementioned concerns, a heuristic dynamic programing (HDP) approach is proposed to optimally control grid-connected VSGs. The neural-network-based inherence of the HDP enables the proposed technique to adapt to any impedance angle. The HDP controller includes two subnetworks: (i) the action network that controls the system optimally and (ii) the critic network, which evaluates the effectiveness of the action network. The simulation and experimental results are provided to evaluate the effectiveness of the proposed technique. As shown, the HDP-based approach illustrates a better performance in comparison with the conventional PI-based VSG in various operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗