Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Dark-matter-enhanced probe of relic neutrino clustering

We propose heavy decaying dark matter (DM) as a new probe of the cosmic neutrino background (C⁢𝜈⁢B). Heavy DM, with mass ≳ 10 9 GeV, decaying into neutrinos can be a new source of ultrahigh-energy (UHE) neutrinos. Including this contribution along with the measured astrophysical and predicted cosmogenic neutrino fluxes, we study the scattering of UHE neutrinos with the C⁢𝜈⁢B via standard weak interactions mediated by the 𝑍 boson. We solve the complete neutrino transport equation, taking into account both absorption and reinjection effects, to calculate the expected spectrum of UHE neutrino flux at future neutrino telescopes, such as the IceCube-Gen2 radio. We argue that such observations can be used to probe the C⁢𝜈⁢B properties and, in particular, local C⁢𝜈⁢B clustering. We find that, depending on the absolute neutrino mass and the DM mass and lifetime, a local C⁢𝜈⁢B overdensity ≳ 10 6 can be probed at the IceCube-Gen2 radio within ten years of data taking.

Dark matter↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose active scanning probe cantilevers for near-field spectroscopy, scanning tunnel imaging, and atomic-resolution lithography

In this work, we report progress on developing a multipurpose scanning probe cantilever applying gallium nitride nanowires as the probe tip. Gallium nitride nanowires possess high potential as probes due to their straight profile, tunable electrical and optical properties, high Young’s Modulus, durability, and high-yield fabrication process. Their wide bandgap enables them to be pumped to emit ultraviolet pulses which can be used for optical imaging and spectroscopy. They can be doped during growth to be electrically conductive, and their sharp tips obtained during epitaxial growth enable confinement of a high electric field at tip–sample interface. Their sharp tips are obtained during fabrication by their epitaxial growth which eliminates the need for postprocess sharpening that is typically required for standard STM tips. We present results of using gallium nitride nanowires for scanning tunnel microscopy applications of atomic-resolution imaging and lithography, and atomic force microscopy applications of imaging and lithography in vacuum and atmospheric environments.

Engineering↗

Imaging beyond the surface region: Probing hidden materials via atomic force microscopy

Probing material properties at surfaces down to the single-particle scale of atoms and molecules has been achieved, but high-resolution subsurface imaging remains a nanometrology challenge due to electromagnetic and acoustic dispersion and diffraction. The atomically sharp probe used in scanning probe microscopy (SPM) has broken these limits at surfaces. Subsurface imaging is possible under certain physical, chemical, electrical, and thermal gradients present in the material. Of all the SPM techniques, atomic force microscopy has entertained unique opportunities for nondestructive and label-free measurements. Here, we explore the physics of the subsurface imaging problem and the emerging solutions that offer exceptional potential for visualization. We discuss materials science, electronics, biology, polymer and composite sciences, and emerging quantum sensing and quantum bio-imaging applications. The perspectives and prospects of subsurface techniques are presented to stimulate further work toward enabling noninvasive high spatial and spectral resolution investigation of materials including meta- and quantum materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

New Laboratory and Astrophysical Probes of Physics Beyond the Standard Model (Final Technical Report)

The first of these directions centers on new ideas in dark matter detection. As experimental scrutiny narrows the window for new physics at the weak scale, it has become apparent that the solution to the dark matter mystery may not reside there. Theoretical developments such as the hidden sector/valley paradigm have, at the same time, shown that compelling theories of dark matter reside below the weak scale. Searching for dark matter at lower mass scales requires looking beyond the current paradigm of dark matter direct detection based on nuclear recoils. It is the goal of this project to provide new ideas to guide the experimental program looking for light dark matter. I am actively proposing ideas for detecting dark matter as light as a meV, well beyond the current focus of GeV-TeV scale dark matter. Some of the ideas I have proposed, such as superconducting, superfluid, and polar material targets, are actively being developed into experiments. My group will provide the relevant calculations to determine dark matter reach, providing crucial input to experiment on which targets should be developed. We will also provide an effective field theory framework to understand which types of experiments are most sensitive to each interaction type. The second of these directions is on probes of dark matter substructure as a mean to constrain, or observe, models of dark matter. The standard ΛCDM paradigm assumes that the dark matter density perturbations are adiabatic, scale invariant, and produced during inflation. However, many standard models of dark matter will produce modifications of this prediction, such as axion models with symmetry broken below the inflationary scale. Remarkably, we have limited direct measurements of the dark matter clumpiness at mass scales below dwarf galaxies. This allows for the possibility of observing modifications from vanilla ΛCDM due to particle dynamics. In many cases, simulations of dark matter structure in the presence of non-scale invariant fluctu- ations are understudied or completely lacking. I plan to develop both theoretical predictions for small scale structure in models with additional matter power on small scales, as well as observa- tional probes of small scale halos or clumps. One idea I have been recently focused on is pulsar timing, though my group will pursue a variety of lensing and astrometric probes. Lastly, the most risky direction involves spacetime fluctuations from quantum gravity. I showed that if one assumes that metric fluctuations in the Minkowski vacuum, at a surface separating a region in and out of causal contact (which we call a “horizon”), are determined by standard thermodynamic considerations at horizon, these metric fluctuations are large enough to observe in an interferometer with similar sensitivity to LIGO. In a follow-up paper we showed that these assumption holds for the vacuum in AdS/CFT. In future work, I plan to connect this work to recent soft graviton results, to frame this work in a concrete Randall-Sundrum model, and to work out concrete phenomenological predictions from the model. This work unquestionably takes a less trodden path, and works well as part of a well-rounded portfolio of less and more risky ideas. Particle physics is currently at a juncture which requires bold exploration of qualitatively new directions. This proposal outlines some of my plans over the coming years in these directions, leaving room also for surprises.

79 ASTRONOMY AND ASTROPHYSICS↗

Manipulating and Probing Ultrafast Atomic and Molecular Dynamics (Final Report)

This program has focused on the exploration and control of dynamics in atoms, small molecules, clusters, and micro- or nano-structures following ultrafast excitation and/or driven by strong oscillating fields. In our principal experiments, gas phase atoms and molecules were exposed to short pulses of electromagnetic radiation with frequencies ranging from THz into the XUV spectral regions, and with durations from picoseconds to attoseconds. The pulses coherently induce and/or probe dynamics in the electronic, vibrational, and rotational degrees of freedom of the targets. The overarching goal of the various projects has been to exploit strong-field processes and/or implement novel ultrafast techniques for manipulating and probing coherent electronic and nuclear motion. Typically, the relevant system evolution occurs over attosecond to picosecond timescales. In doing so, we have gained a more complete picture of correlated multi-particle dynamics in atoms, molecules, and other complex systems and expanded the toolbox of useful techniques for manipulating and probing those dynamics. Grant funds were primarily used to: (i) pay salaries and fringe benefits for the PI and postdocs and stipends, tuition, and health care costs for graduate students; (ii) cover travel expenses for the PI, postdocs, and students to attend and participate in professional meetings, conferences, and workshops; and (iii) purchase research materials, supplies, and equipment required for experiments. The research resulted in the publication of 24 peer reviewed articles (including 1 in Nature Physics, 2 in Nature Communications, 7 in Physical Review Letters, and 12 in Physical Review A), and 4 PhD dissertations. The specific results from different funding periods are summarized separately in the main report.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding Plant Signaling Via Innovations in Probe Delivery and Imaging

The goal of this project was to develop tools for studying plant processes in living tissues. We wanted a method for introducing probes for studying plant processes such that plants could remain intact and imaged iteratively. Towards this end, we successfully optimized carbon nanofibers that we showed could deliver non-permeable signaling probes/biomolecules to plant cells. These were created on a rigid backing and also successfully transferred to a flexible backing to use with curved plant structures. We also built fiber optic microscopes that permit iterative non-destructive fluorescence or light micrographs and created protocols and devices to stabilize plant organs during imaging. These tools were developed in conjunction with research aimed understanding receptor-mediated peptide trafficking and responses relevant to plant cell growth and defense tradeoff. During this project, we designed and built two fiberoptic fluorescence microscopes; (b) designed, fabricated and validated different nanospike designs for delivering probes to plants, including the feasibility of delivering DNA constructs for expression studies; (c) developed fluorescent peptide probes (active and inactive versions of a secreted receptor ligand called phytosulfokine or PSK) and performed mobility tests after application to plants using microscopy; (d) used appropriate genetic plant backgrounds to facilitate PSK trafficking and response mechanisms; (e) determined the transcriptional changes due to PSK-induced signaling related to growth/defense tradeoff; (f) performed experiments showing the growth/defense tradeoff involves repression of specific defense components in response to PSK. This project also involved the training of two PhD students and five Masters students.

47 OTHER INSTRUMENTATION↗

Integral Field Probe for Mapping of Curved Magnets

The Single Stretched Wire (SSW) method allows highly precise integral field measurements by recording voltage across a tensioned wire mounted to 2-axis linear stages at either end of the magnet aperture. However, traditional SSW probes are not well suited for curved accelerator magnets, which are essential for steering charged particles along arced trajectories in storage rings or beamlines. The tension required to eliminate sag demands a purely straight path, making them incompatible with non-linear magnet geometries. To address this limitation for curved magnets, a modified approach was developed using a segmented, 3D-printed support structure that incorporates a pre-shaped anti-sag curve. Under its own weight and that of the wire bundle, the structure deforms to lie flat while conforming to the curvature of the magnet in the horizontal plane. The optimal geometry of the probe was derived using an iterative process combining FEA simulations in Ansys Mechanical with testing of various carbon fiber-reinforced filaments. The printed and assembled probe was successfully used to measure the SDD-059 magnet at Fermilab, yielding promising results.

Jakopin, Alexander [Northern Illinois U.]↗

Probing the Wind Component of Radio Emission in Luminous High-redshift Quasars

We discuss a probe of the contribution of wind-related shocks to the radio emission in otherwise radio-quiet quasars. Given (1) the nonlinear correlation between UV and X-ray luminosity in quasars, (2) that such a correlation leads to higher likelihood of radiation-line-driven winds in more luminous quasars, and (3) that luminous quasars are more abundant at high redshift, deep radio observations of high-redshift quasars are needed to probe potential contributions from accretion disk winds. We target a sample of 50 z ≃ 1.65 color-selected quasars that span the range of expected accretion disk wind properties as traced by broad C iv emission. 3 GHz observations with the Very Large Array to an rms of ≈10 μJy beam -1 probe to star formation rates of ~400 M ⊙ yr -1 , leading to 22 detections. Supplementing these pointed observations are survey data of 388 sources from the LOFAR Two-meter Sky Survey Data Release 1 that reach comparable depth (for a typical radio spectral index), where 123 sources are detected. These combined observations reveal a radio detection fraction that is a nonlinear function of C iv emission-line properties and suggest that the data may require multiple origins of radio emission in radio-quiet quasars. We find evidence for radio emission from weak jets or coronae in radio-quiet quasars with low Eddington ratios, with either (or both) star formation and accretion disk winds playing an important role in optically luminous quasars and correlated with increasing Eddington ratio. Additional pointed radio observations are needed to fully establish the nature of radio emission in radio-quiet quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Insights into the hydro-mechanical behavior of a decimeter-scale fracture using the mini-SIMFIP probe

ABSTRACT: Understanding hydro-mechanical couplings in fractured rocks is essential for predicting the rock mass response during high-pressure fluid injection, including the stimulation of enhanced geothermal systems. However, fluid-driven fracture dislocations are challenging to measure due to the need for local displacement data at high fluid pressures. In this study, fluid-driven displacement across a decimeter-scale laboratory fracture was investigated using the mini-SIMFIP (step rate injection method for fracture in-situ properties) probe, which is a smaller version of the SIMFIP tool (Guglielmi et al., 2014). The mini-SIMFIP probe is able to resolve the full 3D displacement vector of a fracture. The probe was installed in one of two boreholes across a decimeter-scale saw-cut granite fracture. Two pressure step injection tests were conducted under the same isotropic stress conditions. By varying injection between the boreholes, we estimated the aperture profile across the fracture. The results show a consistent pressure-dependent opening as long as steady-state flow was maintained. At a certain pressure step, steady-state conditions were no longer achievable and the fracture opened rapidly. The pressure-opening relationship diverged between the two tests and indicated a homogenization of the aperture profile and an increase in the non-linearity of the flow regime.

Osten, J↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

For the first time, a digital Mirror Langmuir probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I-V characteristics with a high frequency, high power digital amplifier and field-programmable gate array (FPGA) controller. Measurements taken by the MLP were validated by a low speed I-V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field (f̃ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it towards a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution such as edge plasma, scrape-off layer, and divertor probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for error correction in scanning probe microscopy

Disclosed here is a scanning probe microscope system and method for operating the same for producing scanning probe microscope images at fast scan rates and reducing oscillation artifacts. In some embodiments, an inverse consistent image registration method is used to align forward and backward scan traces for each line of the scanning microscope image. In some embodiments, the aligned forward and backward scan traces are combined using a weighting factor favoring the scan trace with higher smoothness. In some embodiments, the scanning probe microscope image is a potentiometry map and a method is provided to extract from the potentiometry map a conductivity map.

47 OTHER INSTRUMENTATION↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

42 ENGINEERING↗

Advanced radio frequency sensing probe

A radio-frequency probe system with a transmitting or receiving element integrated into a cable assembly is disclosed. In some embodiments a preferred configuration may contain one or more sensing elements integrated into the transmitting or receiving element. In another embodiment, the radio frequency probe comprises an antenna body fixed to a coaxial cable, in which the center conductor of the coaxial cable serves as the transmitting or receiving element. A method for monitoring, transmitting, or detecting one or more parameters using a single radio frequency probe is also disclosed.

Sappok, Alexander↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from a medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

Sampling probe

A system for sampling a surface includes a sampling probe including a housing with a probe end having a sampling fluid opening, a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling fluid opening. The sampling fluid exhaust conduit includes a wall, a sampling fluid exhaust conduit inlet opening for removing sampling fluid from the sampling fluid opening, and a sampling fluid exhaust conduit outlet opening for removing fluid from the sampling fluid exhaust conduit. A sampling fluid analytic conduit is also provided in the sampling probe and has a sampling fluid analytic conduit inlet opening spaced upstream from the sampling fluid exhaust conduit outlet opening, downstream from the sampling fluid exhaust conduit inlet opening, and from the wall of the sampling fluid exhaust conduit. A wash conduit can also be provided. Methods for sampling are also disclosed.

Van Berkel, Gary↗

Function-based probes for environmental microbiome analysis and methods of making and using the same

Probe embodiments for identifying analytes involved in biofuel or bioenergy production, bioremediation, or nutrient cycling as well as methods of making and use are described herein. In some embodiments, probes identifying cellulose degradation and/or sugar transport, lignin or chitin degradation, or peptide or toxin metabolism are included. In some embodiments, probes for identifying analytes in a soil sample are included in the compositions and methods disclosed herein.

Wright, Aaron T.↗