Initial Retrieval Validation from the Joint Airborne IASI Validation Experiment (JAIVEx)

The Joint Airborne IASI Validation Experiment (JAIVEx) was conducted during April 2007 mainly for validation of the Infrared Atmospheric Sounding Interferometer (IASI) on the MetOp satellite, but also included a strong component focusing on validation of the Atmospheric InfraRed Sounder (AIRS) aboard the AQUA satellite. The cross validation of IASI and AIRS is important for the joint use of their data in the global Numerical Weather Prediction process. Initial inter-comparisons of geophysical products have been conducted from different aspects, such as using different measurements from airborne ultraspectral Fourier transform spectrometers (specifically, the NPOESS Airborne Sounder Testbed Interferometer (NAST-I) and the Scanning-High resolution Interferometer Sounder (S-HIS) aboard the NASA WB-57 aircraft), UK Facility for Airborne Atmospheric Measurements (FAAM) BAe146-301 aircraft insitu instruments, dedicated dropsondes, radiosondes, and ground based Raman Lidar. An overview of the JAIVEx retrieval validation plan and some initial results of this field campaign are presented.

Zhou, Daniel K.↗

Provenance in Data Interoperability for Multi-Sensor Intercomparison

As our inventory of Earth science data sets grows, the ability to compare, merge and fuse multiple datasets grows in importance. This requires a deeper data interoperability than we have now. Efforts such as Open Geospatial Consortium and OPeNDAP (Open-source Project for a Network Data Access Protocol) have broken down format barriers to interoperability; the next challenge is the semantic aspects of the data. Consider the issues when satellite data are merged, cross-calibrated, validated, inter-compared and fused. We must match up data sets that are related, yet different in significant ways: the phenomenon being measured, measurement technique, location in space-time or quality of the measurements. If subtle distinctions between similar measurements are not clear to the user, results can be meaningless or lead to an incorrect interpretation of the data. Most of these distinctions trace to how the data came to be: sensors, processing and quality assessment. For example, monthly averages of satellite-based aerosol measurements often show significant discrepancies, which might be due to differences in spatio- temporal aggregation, sampling issues, sensor biases, algorithm differences or calibration issues. Provenance information must be captured in a semantic framework that allows data inter-use tools to incorporate it and aid in the intervention of comparison or merged products. Semantic web technology allows us to encode our knowledge of measurement characteristics, phenomena measured, space-time representation, and data quality attributes in a well-structured, machine-readable ontology and rulesets. An analysis tool can use this knowledge to show users the provenance-related distrintions between two variables, advising on options for further data processing and analysis. An additional problem for workflows distributed across heterogeneous systems is retrieval and transport of provenance. Provenance may be either embedded within the data payload, or transmitted from server to client in an out-of-band mechanism. The out of band mechanism is more flexible in the richness of provenance information that can be accomodated, but it relies on a persistent framework and can be difficult for legacy clients to use. We are prototyping the embedded model, incorporating provenance within metadata objects in the data payload. Thus, it always remains with the data. The downside is a limit to the size of provenance metadata that we can include, an issue that will eventually need resolution to encompass the richness of provenance information required for daata intercomparison and merging.

Lynnes, Chris↗

Changes in the TRMM Version 7 Space/Time Averaged Level 3 Data Products Based on GPROF TMI Swath-Based Precipitation Retrievals

TRMM has three level 3 (space/time averaged) data products that aggregate level 2 TRMM Microwave Imager (TMI) GPROF precipitation retrievals. These three products are TRMM 3A12, which is a monthly accumulation of 2A12 the GPROF swath retrieval product; TRMM 3B31, which is a monthly accumulation of 2A12 and 2B31 the combined retrieval product that uses both Precipitation Radar (PR) and TMI data; and 3G68 and its variants, which provide hourly retrievals for TMI, PR and combined. The 3G68 products are packaged as daily files but provide hourly information at 0.5 deg x 0.5 deg resolution globally, 0.25 deg x 0.25 deg globally, or 0.1 deg x 0.1 deg over Africa, Australia and South America. This paper will present early information of the changes in the v7 TMI GPROF level 2 retrievals that have an impact on the level 3 accumulations. This paper provides an analysis of the effect the 2A12 GPROF changes have on 3G68 products. In addition, it provides a comparison between the TRMM level 3 products that use the TMI GPROF swath retrievals.

Stocker, Erich↗

Limb Correction of RGB Composite Imagery for Improved Interpretation

RGB (Red‐Green‐Blue) imagery, created by integrating several spectral channels into one composite image, is currently used by the operational weather community to aid in quick, real‐time analysis of atmospheric processes. However, the limb effect - a result of an increasing optical path length of the absorbing atmosphere between the satellite and the earth as scan angle increases - interferes with the qualitative interpretation of RGB composites at large scan angles. It also makes the comparison of similar products from multiple satellite sensors difficult. Recent work has indicated that correcting for the limb effect in the basic channel imagery using simple statistical relationships greatly improves the utility of the derived RGB imagery. However, it is hypothesized that the limb correction coefficients vary with respect to latitude, season, cloud cover, and surface albedo. This poster will highlight an improved approach to the limb correction of RGB imagery using varying coefficients. The Joint Center for Satellite and Data Assimilation (JCSDA) Community Radiative Transfer Model (CRTM) was used to simulate top of atmosphere brightness temperatures at varying scan angles for infrared channels corresponding to the Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Suomi NPP Visible Infrared Imaging Radiometer Suite (VIIRS), and Meteosat‐10 Spinning Enhanced Visible and Infrared Imager (SEVIRI) sensors. A subset of European Center for Medium‐Range Weather Forecasts (ECMWF) temperature, specific humidity, and ozone mixing ratio profiles from March 2013 through February 2014 were used as input to the CRTM. The simulated brightness temperatures were used to determine the best fit slope of the linear relationship between the natural log of the cosine of the scan angle and the difference of the simulated brightness temperature at nadir and on the limb. The correction coefficients were then analyzed for variability with respect to latitude, season, cloud cover, and surface type and used to produce improved limb corrected imagery. Applications of the results will be presented.

Elmer, Nicholas↗

Capabilities and Limitations of MISR Aerosol Products in Dust-Laden Regions

Atmospheric mineral dust particles have significant effects on climate and the environment, and despite notable advances in modeling and satellite and ground-based measurements, remain one of the major factors contributing to large uncertainty in aerosol radiative forcing. We examine the Multi-angle Imaging SpectroRadiometer (MISR) 11+ year aerosol data record to demonstrate MISR's unique strengths and assess potential biases of MISR products for dust study applications. In particular, we examine MISR's unique capabilities to 1) distinguish dust aerosol from spherical aerosol types, 2) provide aerosol optical depths over bright desert source regions, and 3) provide high-resolution retrievals of dust plume heights and associated winds. We show examples of regional and global MISR data products in dusty regions together with quantitative evaluations of product accuracies through comparisons with independent data sources, and demonstrate applications of MISR data to dust regional and climatological studies, such as dust property evolution during transport, dust source climatology in relation to climatic factors, and dust source dynamics. The potential use of MISR radiance data to study dust properties is also discussed.

dust aerosol↗

Compositional and Microstructural Evolution of Olivine During Pulsed Laser Irradiation: Insights Based on a FIB/Field-Emission TEM Study

Introduction: The use of pulsed laser irradiation to simulate the short duration, high-energy conditions characteristic of micrometeorite impacts is now an established approach in experimental space weathering studies. The laser generates both melt and vapor deposits that contain nanophase metallic Fe (npFe(sup 0)) grains with size distributions and optical properties similar to those in natural impact-generated melt and vapor deposits. There remains uncertainty, however, about how well lasers simulate the mechanical work and internal (thermal) energy partitioning that occurs in actual impacts. We are currently engaged in making a direct comparison between the products of laser irradiation and experimental/natural hypervelocity impacts. An initial step reported here is to use analytical TEM is to attain a better understanding of how the microstructure and composition of laser deposits evolve over multiple cycles of pulsed laser irradiation. Experimental Methods: We irradiated pressed-powder pellets of San Carlos olivine (Fo(sub 90)) with up to 99 rastered pulses of a GAM ArF excimer laser. The irradiated surface of the sample were characterized by SEM imaging and areas were selected for FIB cross sectioning for TEM study using an FEI Quanta dual-beam electron/focused ion beam instrument. FIB sections were characterized using a JEOL2500SE analytical field-emission scanning transmission electron microscope (FE-STEM) optimized for quantitative element mapping at less than 10 nm spatial resolutions. Results: In the SEM the 99 pulse pressed pellet sample shows a complex, inhomogeneous, distribution of laser-generated material, largely concentrated in narrow gaps and larger depressions between grains. Local concentrations of npFe0 spherules 0.1 to 1 micrometers in size are visible within these deposits in SEM back-scatter images. Fig. 1 shows bright-field STEM images of a FIB cross-section of a one of these deposits that continuously covers the top and sloping side of an olivine grain. The deposit has 3 microstructurally distinct sub-layers composed of silicate glass with varying modal fractions and size distributions of npFe( sup 0) spherules, along with nanocrystalline silicate material. A relatively thin (50-300 nm) topmost surface layer has a high-concentration of npFe0 spherules 5-20 nm in size. Element mapping shows the layer to be enriched in Fe by a factor of 2.5 relative to the olivine substrate, with Mg and Si depleted by 20% and 10% respectively. This is compositionally complementary to the underlying, middle layer of the deposit that is depleted in Fe, enriched in Mg and has a much lower npFe0 concentration. A third layer of nanocrystalline olivine occurs at the substrate interface. Discussion: The FE-STEM results suggest the topmost layer is a vapor deposit, underlain by a thicker microstructurally complex melt-generated layer. The compositional relations suggest the melt layer was partially vaporized, preferentially losing more volatile elements (e.g., Fe). The vaporized material re-condensed to form the thin, npFe(sup 0)-rich surface deposit during or immediately after the scan cycle. Nanocrystalline olivine that grew within the melt layer as it formed and cooled is similar in volume and microstructure to what we have observed in the impact melt lining of a micrometeorite impact crater in olivine. This suggest the time-temperature relations attained in the laser sample may not be too different from a micrometeorite impact. Our TEM observations, however, do not show evidence for the same level of mechanical dam-age (e.g., fracturing) seen around the natural micrometeorite crater.

Christoffersen, R.↗

Compositional and Microstructural Evolution of Olivine Under Multiple-Cycle Pulsed Laser Irradiation as Revealed by FIB/Field-Emission TEM

The use of pulsed laser irradiation to simulate the short duration, high-energy conditions characteristic of micrometeorite impacts is now an established approach in experimental space weathering studies. The laser generates both melt and vapor deposits that contain nanophase metallic Fe (npFe(sup 0)) grains with size distributions and optical properties similar to those in natural impact-generated melt and vapor deposits. There remains uncertainty, however, about how well lasers simulate the mechanical work and internal (thermal) energy partitioning that occurs in actual impacts. We are currently engaged in making a direct comparison between the products of laser irradiation and experimental/natural hypervelocity impacts. An initial step reported here is to use analytical SEM and TEM is to attain a better understanding of how the microstructure and composition of laser deposits evolve over multiple cycles of pulsed laser irradiation.

Christoffersen, R.↗

The CO2 Abundance in Comets C2012 K1 (PanSTARRS), C2012 K5 (LINEAR), and 290P Jager as Measured with Spitzer

Carbon dioxide is one of the most abundant ices present in comets and is therefore important for understanding cometary composition and activity. We present analysis of observations of CO2 and [O I] emission in three comets to measure the CO2 abundance and evaluate the possibility of employing observations of [O I] emission in comets as a proxy for CO2. We obtained NIR imaging sensitive to CO2 of comets C/2012 K1 (PanSTARRS), C/2012 K5 (LINEAR), and 290P/Jager with the IRAC instrument on Spitzer. We acquired observations of [O I] emission in these comets with the ARCES echelle spectrometer mounted on the 3.5-m telescope at Apache Point Observatory and observations of OH with the Swift observatory (PanSTARRS) and with Keck HIRES (Jager). The CO2/H2O ratios derived from the Spitzer images are 12.6 +/- 1.3% (PanSTARRS), 28.9 +/- 3.6% (LINEAR), and 31.3 +/- 4.2% (Jager). These abundances are derived under the assumption that contamination from CO emission is negligible. The CO2 abundance for PanSTARRS is close to the average abundance measured in comets at similar heliocentric distance to date, while the abundances measured for LINEAR and Jager are significantly larger than the average abundance. From the coma morphology observed in PanSTARRS and the assumed gas expansion velocity, we derive a rotation period for the nucleus of about 9.2 h. Comparison of H2O production rates derived from ARCES and Swift data, as well as other observations, suggest the possibility of sublimation from icy grains in the inner coma. We evaluate the possibility that the [O I] emission can be employed as a proxy for CO2 by comparing CO2/H2O ratios inferred from the [O I] lines to those measured directly by Spitzer. We find that for PanSTARRS we can reproduce the observed CO2 abundance to an accuracy of approximately 20%. For LINEAR and Jager, we were only able to obtain upper limits on the CO2 abundance inferred from the [O I] lines. These upper limits are consistent with the CO2 abundances measured by Spitzer.

McKay, Adam J.↗

GEONEX: Challenges in Producing MODIS-Like Land Products from a New Generation of Geostationary Sensors

The new generation geostationary (GEO) remote sensors (GOES-R ABI, Himawari AHI, and FY4 AGRI) provide high frequency (5-15 minute) observations spatially/spectrally similar to MODIS/VIIRS for land monitoring. These new features of GEO satellite sensors make producing MODIS like land products for terrestrial monitoring possible. The NASA Earth Exchange (NEX) team developed the GEONEX pipeline that is containerized, deployable on NASA Pleiades supercomputer as well as public cloud platforms (e.g. AWS). The processing pipeline is designed to take Himawari Standard Data (HSD) and GOES-16 L1b to generate surface reflectance (SR) and other high-level land remote sensing products. In order to produce low-Earth-orbiting (LEO) remote sensing compatible land products, inter-comparison between Himawari AHI and MODIS Terra/Aqua has been conducted in this research work. Comparisons of TOA reflectance and surface reflectance between AHI and Terra/Aqua are presented. Ray-Matching method was used to locate the co-located pixels, where GEO and LEO sensors look at the land target with similar Viewing Zenith Angle (VZA) and Viewing Azimuth Angle (VAA) simultaneously. Here, we address challenges associated with the selection of qualified pixels of similar solar illumination condition and atmosphere path. We used strict criterion to constrain the pixel selection: the time difference between GEO and LEO observations is less than +-2.5 mins, the cosine of VZA difference is less than 1%, and the VAA difference is less than 10 deg. We also discuss the strong radiometric consistency that the new generation GEO sensors along with the popular LEO sensors would benefit the environmental remote sensing community.

Li, Shuang↗

Direct Comparisons Between GPM-DPR and CloudSat Snowfall Retrievals

Two spaceborne radars currently in orbit enable the sampling of snowfall near the surface and throughout the atmospheric column, namely, CloudSat’s Cloud Profiling Radar (CPR) and the Global Precipitation Measurement mission’s Dual-Frequency Precipitation Radar (GPM-DPR). In this paper, a direct comparison of the CPR’s 2C-SNOW-PROFILE (2CSP), the operational GPM-DPR algorithm (2ADPR) and a neural network (NN) retrieval applied to the GPM-DPR data is performed using coincident observations between both radars. Examination of over 3500 profiles within moderate to strong precipitation (Ka band ≥ 18 dBZ) show that the NN retrieval provides the closest retrieval of liquid equivalent precipitation rate R immediately above the melting level to the R retrieved just below the melting layer, agreeing within 5%. Meanwhile, 2CSP retrieves a maximum value of R at −15°C, decreases by 35% just above the melting layer, and is about 50% smaller than the GPM-DPR retrieved R below the melting layer. CPR-measured reflectivity shows median reduction of 2–3 dB from −15° to −2.5°C, likely the reason for the 2CSP retrieval reduction of R . Two case studies from NASA field campaigns [i.e., Olympic Mountains Experiment (OLYMPEX) and Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS)] provide analogs to the type of precipitating systems found in the comparison between retrieval products. For the snowfall events that GPM-DPR can observe, this work suggests that the 2CSP retrieval is likely underestimating the unattenuated reflectivity, resulting in a potential negative, or low, bias in R . Future work should investigate how frequently the underestimated reflectivity profiles occur within the CPR record and quantify its potential effects on global snowfall accumulation estimation.

Atmosphere↗

Comparison of Commercial, State-of-the-Art, Fossil-Based Hydrogen Production Technologies

This presentation provides a deep dive overview of the NETL report publication "Comparison of Commercial, State-of-the-Art, Fossil-Based Hydrogen Production Technologies" released in April 2022. A summary of the study justification, objectives, and approach are presented along with a detailed overview of the major study phases and results.

Lewis, Eric↗

Consistency of Global Modis Aerosol Optical Depths over Ocean on Terra and Aqua Ceres SSF Datasets

Aerosol retrievals over ocean from the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard Terra and Aqua platforms are available from the Clouds and the Earth's Radiant Energy System (CERES) Single Scanner Footprint (SSF) datasets generated at NASA Langley Research Center (LaRC). Two aerosol products are reported side-by-side. The primary M product is generated by sub-setting and remapping the multi-spectral (0.47-2.1 micrometer) MODIS produced oceanic aerosol (MOD04/MYD04 for Terra/Aqua) onto CERES footprints. M*D04 processing uses cloud screening and aerosol algorithms developed by the MODIS science team. The secondary AVHRR-like A product is generated in only two MODIS bands 1 and 6 (on Aqua, bands 1 and 7). The A processing uses the CERES cloud screening algorithm, and NOAA/NESDIS glint identification, and single-channel aerosol retrieval algorithms. The M and A products have been documented elsewhere and preliminarily compared using 2 weeks of global Terra CERES SSF Edition 1A data in which the M product was based on MOD04 collection 3. In this study, the comparisons between the M and A aerosol optical depths (AOD) in MODIS band 1 (0.64 micrometers), tau(sub 1M) and tau(sub 1A) are re-examined using 9 days of global CERES SSF Terra Edition 2A and Aqua Edition 1B data from 13 - 21 October 2002, and extended to include cross-platform comparisons. The M and A products on the new CERES SSF release are generated using the same aerosol algorithms as before, but with different preprocessing and sampling procedures, lending themselves to a simple sensitivity check to non-aerosol factors. Both tau(sub 1M) and tau(sub 1A) generally compare well across platforms. However, the M product shows some differences, which increase with ambient cloud amount and towards the solar side of the orbit. Three types of comparisons conducted in this study - cross-platform, cross-product, and cross-release confirm the previously made observation that the major area for improvement in the current aerosol processing lies in a more formalized and standardized sampling (and most importantly, cloud screening) whereas optimization of the aerosol algorithm is deemed to be an important yet less critical element.

Ignatov, Alexander↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the MODIS Collection 6 Multilayer Cloud Detection Algorithm Through Comparisons with Cloudsat Cloud Profiling Radar and CALIPSO CALIOP Products

Since multilayer cloud scenes are common in the atmosphere and can be an important source of uncertainty in passive satellite sensor cloud retrievals, the MODIS MOD06 and MYD06 standard cloud optical property products include a multilayer cloud detection algorithm to assist with data quality assessment. This paper presents an evaluation of the Aqua MODIS MYD06 Collection 6 multilayer cloud detection algorithm through comparisons with active Cloud Profiling Radar (CPR) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) products that have the ability to provide cloud vertical distributions and directly classify multilayer cloud scenes and layer properties. To compare active sensor products with an imager such as MODIS, it is first necessary to define multilayer clouds in the context of their radiative impact on cloud retrievals. Three main parameters have thus been considered in this evaluation: (1) the maximum separation distance between two cloud layers, (2) the thermodynamic phase of those layers and (3) the upper-layer cloud optical thickness. The impact of including the Pavolonis–Heidinger multilayer cloud detection algorithm, introduced in Collection 6, to assist with multilayer cloud detection has also been assessed. For the year 2008, the MYD06 C6 multilayer cloud detection algorithm identifies roughly 20% of all cloudy pixels as multilayer (decreasing to about 13% if the Pavolonis–Heidinger algorithm output is not used). Evaluation against the merged CPR and CALIOP2B-CLDCLASS-lidar product shows that the MODIS multilayer detection results are quite sensitive to how multilayer clouds are defined in the radar and lidar product and that the algorithm performs better when the optical thickness of the upper cloud layer is greater than about 1.2 with a minimum layer separation distance of 1 km. Finally, we find that filtering the MYD06 cloud optical properties retrievals using the multilayer cloud flag improves aggregated statistics, particularly for ice cloud effective radius.

MODIS↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Side-reaction products identified for photo-nuclear production of 99 Mo

Production of 99 Mo by the 100 Mo (γ, n) 99 Mo reaction through the bremsstrahlung process using an electron accelerator is one of the feasible options currently pursued by several countries. In this work, we report experimental results on identification of side-reaction products after the irradiation of natural and enriched 100 Mo targets. Side-reaction products identified include various Mo, Nb and Zr isotopes. Comparison of experimentally determined reaction production rates with those determined based on theoretical cross-sections will be presented. Moreover, activation products formed due to presence of impurities introduced during the manufacturing of the Mo targets will also be discussed.