Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

Engineered Edge Effect Stress Redistribution in Suspended Thin Film Stacks for Flatness Control

This paper presents the systematic study of edge effect stresses and interaction between thin film stacks to achieve flat suspended thin film structures. Finite element modeling (FEM) was used for rapid analysis of support structures on microshutter array (MSA) shutter blades. The design application aims to flatten the blades to provide ultra-high contrast to optical detectors using MSAs as field masks. This is the first comprehensive study of microscopic surface feature edge effect and film-to-film stress interaction in micro electromechanical systems (MEMS). This study demonstrates flattening of thin film stacks by stress redistribution by induced shear force at the edge of strategically designed reinforcement structures.

Thin Film MEMS↗

NREL's Capabilities in Analytical Sciences Supporting Research and Development (R&D)

NREL researchers perform biomass characterization in dedicated laboratories working with over $5 million in state-of-the-art analytical equipment. A dedicated team of highly skilled analytical chemists have over 100 cumulative years of experience in characterization. They have three specialized laboratories with dedicated sample processing and advanced analytical equipment. Core capabilities include biomass and biochemical characterization and quantification, publicly available laboratory analytical procedures (LAPs), and near-infrared rapid analysis.

analysis↗

Unified Analysis of Aerospace Structures through Implementation of Rapid Tools into a Stress Framework

Rapid structural analysis tools have become an important part of the design cycle for aerospace companies for the last several decades. As these tools have been developed over time, there is often little consideration for shared software infrastructure between the tools, which makes design and analysis cumbersome due to a lack of commonality in input and output data and reporting, as well as poor traceability of results. Under the Rapid Tools task of the Advanced Composites Consortium (ACC), four aerospace tools were recently implemented or enhanced in the HyperSizer stress framework and then evaluated by this consortium of industry and government organizations. The framework provides an automated software environment for executing the rapid tools for analysis and sizing, quantifying margins of safety for thousands of load cases, and generating reports in support of FAA certification. This paper describes the process by which the tools were enhanced or implemented in the stress framework under the ACC project, and the evaluation conducted by industry consortium members.

Craig S Collier↗

Pulsatile instability in rapid directional solidification - Strongly-nonlinear analysis

In the rapid directional solidification of a dilute binary alloy, analysis reveals that, in addition to the cellular mode of Mullins and Sekerka (1964), there is an oscillatory instability. For the model analyzed by Merchant and Davis (1990), the preferred wavenumber is zero; the mode is one of pulsation. Two strongly nonlinear analyses are performed that describe this pulsatile mode. In the first case, nonequilibrium effects that alter solute rejection at the interface are taken asymptotically small. A nonlinear oscillator equation governs the position of the solid-liquid interface at leading order, and amplitude and phase evolution equations are derived for the uniformly pulsating interface. The analysis provides a uniform description of both subcritical and supercritical bifurcation and the transition between the two. In the second case, nonequilibrium effects that alter solute rejection are taken asymptotically large, and a different nonlinear oscillator equation governs the location of the interface to leading order. A similar analysis allows for the derivation of an amplitude evolution equation for the uniformly pulsating interface. In this case, the bifurcation is always supercritical. The results are used to make predictions about the characteristics of solute bands that would be frozen into the solid.

Merchant, G. J.↗

A data analysis method to rapidly characterize gallium concentration in plutonium matrices using LIBS

The processing of actinide samples is a complex and costly endeavor that requires compositional analysis at various stages. Laser-induced breakdown spectroscopy (LIBS) has been used to analyze actinide-containing samples in many nuclear applications including waste management, fuel processing and forensics. The LIBS spectrum obtained from actinide materials are generally extremely complex, exhibiting many thousands of strong emission lines. This makes it difficult to identify other elements within the sample of interest, given the rich and dominant actinide spectrum. Here, in this article, we describe a recent effort to identify and quantify impurities and alloying constituents in plutonium matrices using a hand-held LIBS instrument that is used to rapidly and efficiently measure an emission spectrum from a material sample. We tabulate the emission line positions and intensities of plutonium. We report the development of machine-learning software that can identify gallium and quantify its concentration in plutonium matrices. This work has the potential to provide a rapid and nearly non-destructive technique that allows more confidence in characterizing the composition of materials that are present within complex actinide associated targets. We describe how our LIBS measurements and data analysis methods have successfully quantified the gallium concentration in a variety of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and Methods for Advanced Rapid Imaging and Analysis for Earthquakes

Many embodiments provide a hybrid data processing system (HySDS) of an end-to-end geodetic imaging data system enabling near-real-time science, assessment, response, and rapid recovery. The HySDS may be an operation data processing system that integrates data from many different geodetic data sources and/or sensors, including interferometric synthetic aperture radar (InSAR), GPS, pixel tracking, seismology, and/or modeling, and processes the data to generate actionable high quality science data products. The HySDS may provide for an automated imaging and analysis capabilities that is able to handle the imminent increases in raw data from new and existing geodetic monitoring sensor systems.

Owen, Susan Ethel↗

An Analysis of the Rapidly Rotating Bp star HD 133880

HD 133880 is a rapidly rotating chemically peculiar B-type (Bp) star (nu sin i approx = 103km/s) and is host to one of the strongest magnetic fields of any Ap/Bp star. A member of the Upper Centaurus Lupus association, it is a star with a well-determined age of 16 Myr. 12 new spectra, four of which are polarimetric, obtained from the FEROS, ESPaDOnS and HARPS instruments, provide sufficient material from which to re-evaluate the magnetic field and obtain a first approximation to the atmospheric abundance distributions of He, O, Mg, Si, Ti. Cr, Fe, Ni, Pr and Nd. An abundance analysis was carried out using ZEEMAN, a program which synthesizes spectral line profiles for stars with permeating magnetic fields. The magnetic field structure was characterized by a colinear multipole expansion from the observed variations of the longitudinal and surface fields with rotational phase. Both magnetic hemispheres are clearly visible during the stellar rotation, and thus a three-ring abundance distribution model encompassing both magnetic poles and magnetic equator with equal spans in colatitude was adopted. Using the new magnetic field measurements and optical photometry together with previously published data, we refine the period of HD 133880 to P = 0.877 476 +/- 0.000009 d. Our simple axisymmetric magnetic field model is based on a predominantly quadrupolar component that roughly describes the field variations. Using spectrum synthesis, we derived mean abundances for O, Mg, Si, Ti, Cr, Fe and Pr. All elements; except Mg, are overabundant compared to the Son. Mg appears to be approximately uniform over the stellar surface, while all other elements are more abundant in the negative magnetic hemisphere than in the positive magnetic hemisphere. In contrast to most Ap/Bp stars which show an underabundance in 0, in HD 133880 this element is clearly overabundant compared to the solar abundance ratio. In studying the Ha and Paschen lines in the optical spectra, we could not unambiguously detect information about the magnetosphere of HD 133880. However, radio emission data at both 3 and 6 cm suggest that the magnetospheric plasma is held in rigid rotation with the star by the magnetic field and further supported against collapse by the rapid rotation. Subtle differences in the shapes of the optically thick radio light curves at 3 and 6 cm suggest that the large-scale magnetic field is not fully axisymmetric at large distances from the star.

Bailey, J. D.↗

Trimethyloxonium-mediated methylation strategies for the rapid and simultaneous analysis of chlorinated phenols in various soils by electron impact gas chromatography–mass spectrometry

Abstract The efficient methylation of a panel of five industrial and environmentally-relevant chlorophenols (CPs) employing trimethyloxonium tetrafluoroborate (TMO) for their qualitative detection and identification by electron impact gas chromatography–mass spectrometry (EI-GC–MS) is presented. The protocol’s execution is simple and smoothly converts the phenols into their O-methylated counterparts conveniently at ambient temperature. The efficiency of two versions of the protocol was successfully tested in their ability to simultaneously derivatize five CPs (2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol and triclosan) in six distinct, separate soil matrices (Nebraska EPA standard soil, Virginia Type A soil, Ottawa sand, Baker sand, Silt and Georgia EPA standard soil) when present at low levels (~ 10 μgg −1 ). The first version involves the direct derivatization of the spiked soils with the methylating salt while the second one involves an initial soil extraction step of the CPs followed by methylation. The MDL values for each methylated CP were determined and lower values were found (4.1–13.2 ng . mL −1 ) for both sand matrices (Ottawa and Baker) as well as for the Georgia EPA standard soil, while larger values (8.2–21.8 ng . mL −1 ) were found for the Virginia Type soil, Nebraska EPA standard soil and Silt. The presented protocol offers a safer and more practical alternative to the universally employed diazomethane method and can be readily applicable to matrices other than soils. Furthermore, the protocols described herein may find applicability to the methylation of other analytes bearing acidic protons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and precise analysis for calcium in blood serum

Differential absorption spectrophotometric technique, using murexide, gives a highly precise analysis of calcium in volumes of blood serum as small as 0.01 ml. The method of additions and proper timing allows compensation to be made for fading, variation in type of serum or plasma, and aging of the specimen.

Holtzman, R. B.↗