Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

X-ray diffraction characterization of magnetostriction in Terfenol-D

The magnetostrictive response of a Terfenol-D pellet was measured via a laboratory-based X-ray diffractometer. X-ray diffraction patterns were collected from the pellet sample with and without the presence of an applied magnetic field (~30 mT) generated by placing a large magnet under the pellet. A standard reference material, Silicon 640c, was employed as an internal standard. Magnetostriction values of 323 and 227 ppm Δl/l were determined for the (104) and (110) indexed peaks, respectively, assuming a rhombohedral structure for Terfenol-D. A threshold noise level value of ~20 to 30 ppm Δl/l was suggested based on before/after measurements in the absence of the applied field. No clear evidence of domain wall rotation was detected via changes in relative intensities of diffraction peaks in the presence of the applied magnetic field.

Magnetostriction↗

Isotopic Heterogeneity Imaged in a Uranium Fuel Pellet with Extreme Ultraviolet Laser Ablation and Ionization Time-of-Flight Mass Spectrometry

We use extreme ultraviolet laser ablation and ionization time-of-flight mass spectrometry (EUV TOF) to map uranium isotopic heterogeneity at the nanoscale (=100 nm). Using low-enriched uranium fuel pellets that were made by blending two isotopically distinct feedstocks, we show that EUV TOF can map the 235U/238U content in 100 nm-sized pixels. The two-dimensional (2D) isotope maps reveal U ratio variations in sub-microscale to =1 µm areas of the pellet that had not been fully exposed by microscale or bulk mass spectrometry analyses. Compared to the ratio distribution measured in a homogeneous U reference material, the ratios in the enriched pellet follow a ~3× wider distribution. These results indicate U heterogeneity in the fuel pellet from incomplete blending of the different source materials. EUV TOF results agree well with those obtained on the same enriched pellets by nanoscale secondary ionization mass spectrometry (NanoSIMS), which reveals a comparable U isotope ratio distribution at the same spatial scale. EUV TOF’s ability to assess and map isotopic heterogeneity at the nanoscale makes it a promising tool in fields such as nuclear forensics, geochemistry, and biology that could benefit from uncovering sub-microscale sources of chemical modifications.

Rush, Lydia A.↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Gas-Phase Ion Reactivity of 50 Elements with NO and the Direct Application for 239 Pu in Complex Matrices Using ICP-MS/MS

Understanding the reactivity of metal cations with various reaction gases in ICP-MS/MS is important to determine the best gas to use for a given analyte/interference pair. In this study, nitric oxide (NO) was investigated as the reaction gas following previous experimental designs. The reactions with 50 elements were investigated to examine periodic trends in reactivity, validate theoretical modeling of reaction enthalpies as a method to screen reactant gases, and provide a baseline for potential in-line gas separation methods. ICP-MS/MS studies involving actinides are typically limited to Th, U and Pu, with analyses of Np and Am rarely reported in the literature. To date, only two previous methods have investigated the use of NO in ICP-MS/MS analyses. To showcase the utility of NO, a method was developed to measure 239 Pu in the presence of environmental matrix constituent and other actinides, like what could be expected from post-detonation debris, with no chemical separation prior to analysis. 239 Pu + was reacted to form 239 Pu 16 O + , eliminating interferences derived from the sample matrix by measuring 239 Pu + intensity at m/z = 255 ( 239 Pu 16 O + ). To validate NO for 238 U 1 H + interference removal in environmental matrices, standard reference materials were diluted to 1 mg per gram of solution and spiked to 0.05 pg/g of 239 Pu and 1 µg/g 238 U (Pu/U = 5 x 10 -8 ). Measured 239 Pu concentrations were within 6% of the spiked value. In conclusion, these results demonstrate that reliable 239 Pu measurements can be made at levels relevant to nuclear forensics without the need for extensive chemical matrix separation prior to analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the Quantification of Critical Elements in WTE and Coal Ash via Alkaline Fusion: Superiority of Lithium Metaborate (LiBO 2 )

Ashes generated from coal combustion, as well as waste incineration, can be a potential source of critical elements necessary for the ongoing transition towards electrification and greener energy technologies. For the quantification of critical elements, traditional methods such as acid digestion are time-intensive and can fail to dissolve critical elements in refractory minerals. One potential solution is to adopt alkaline fusion for faster, total digestion. However, the role of flux choice and the subsequent digestion efficiency (DE) is unknown. Here, we report a systematic investigation on the feasibility of alkaline fusion with Lithium Metaborate (LiBO 2 ) and Lithium Tetraborate (Li 2 B 4 O 7 ) as fluxes for the digestion of two standard reference materials (BCR 176R and SRM 1633c). Our findings suggest that LiBO 2 yields higher DE values than Li 2 B 4 O 7 for several critical REEs and volatiles, such as Pb and Cd. Specifically, for REEs in SRM 1633c, the DE values with LiBO 2 are, on average, ~16 percent higher than those with Li 2 B 4 O 7 . Similarly, for Pb and Cd in BCR 176R, the DE values with LiBO 2 are ~20 percent higher than with Li 2 B 4 O 7 . These results suggest that LiBO 2 is a superior flux for rapid ash digestion.

01 COAL, LIGNITE, AND PEAT↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Phosphate-Based Approaches for Dechlorination and Treatment of Salt Waste from Electrochemical Processing of Used Nuclear Fuel: A Perspective on Recent Work

Phosphate-based reagents are being considered by the U.S. Department of Energy (DOE) Office of Nuclear Energy to process halide salt-based nuclear wastes for stabilization prior to disposal. As evidenced by the Experimental Breeder Reactor-II (EBR-II) project, electrochemical processing (pyroprocessing) can be employed to recover uranium and other actinides for reintegration into the nuclear fuel cycle from metallic fuels. The resultant salt-based wastes generated from electrochemical processing of EBR-II fuel contains fission products within a LiCl–KCl eutectic salt that necessitate appropriate disposal. This paper provides an overview of recent efforts to support halide-based salt waste treatment for disposition, as well as a basis for comparison with other related efforts in salt waste treatment through salt partitioning initiatives. The U.S. DOE has selected a phosphate waste form reference material for further investigation and longer-term studies.

electrorefiner↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and characterization of multiphase ceramic designer waste forms

Abstract The long-term performance, or resistance to elemental release, is the defining characteristic of a nuclear waste form. In the case of multiphase ceramic waste forms, correlating the long-term performance of multiphase ceramic waste forms in the environment to accelerated chemical durability testing in the laboratory is non-trivial owing to their complex microstructures. The fabrication method, which in turn affects the microstructure, is further compounding when comparing multiphase ceramic waste forms. In this work, we propose a “designer waste form” prepared via spark plasma sintering to limit interaction between phases and grain growth during consolidation, leading to monolithic high-density waste forms, which can be used as reference materials for comparing the chemical durability of multiphase waste forms. Designer waste forms containing varying amounts of hollandite in the presence of zirconolite and pyrochlore in a fixed ratio were synthesized. The product consistency test (PCT) and vapor hydration test (VHT) were used to assess the leaching behavior. Samples were unaffected by the VHT after 1500 h. As measured by the PCT, the fractional Cs release decreased as the amount of hollandite increased. Elemental release from the zirconolite and pyrochlore phases did not appear to significantly contribute to the elemental release from the hollandite phase in the designer waste forms.

36 MATERIALS SCIENCE↗

ToF-SIMS evaluation of PEG-related mass peaks and applications in PEG detection in cosmetic products

Polyethylene glycols (PEGs) are used in industrial, medical, health care, and personal care applications. The cycling and disposal of synthetic polymers like PEGs pose significant environmental concerns. Detecting and monitoring PEGs in the real world calls for immediate attention. This study unveils the efficacy of time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a reliable approach for precise analysis and identification of reference PEGs and PEGs used in cosmetic products. By comparing SIMS spectra, we show remarkable sensitivity in pinpointing distinctive ion peaks inherent to various PEG compounds. Moreover, the employment of principal component analysis effectively discriminates compositions among different samples. Notably, the application of SIMS two-dimensional image analysis visually portrays the spatial distribution of various PEGs as reference materials. The same is observed in authentic cosmetic products. The application of ToF-SIMS underscores its potential in distinguishing PEGs within intricate environmental context. ToF-SIMS provides an effective solution to studying emerging environmental challenges, offering straightforward sample preparation and superior detection of synthetic organics in mass spectral analysis. These features show that SIMS can serve as a promising alternative for evaluation and assessment of PEGs in terms of the source, emission, and transport of anthropogenic organics.

36 MATERIALS SCIENCE↗

Inference of principal species in caustic aluminate solutions through solid-state spectroscopic characterization

Tetrahedrally coordinated aluminate Al(OH) 4 – and dialuminate Al 2 O(OH) 6 2– anions are considered to be major species in aluminum-rich alkaline solutions. However, their relative abundance remains difficult to spectroscopically quantify due to local structure similarities and poorly understood effects arising from extent of polymerization and counter-cations. To help unravel these relationships in this paper we report detailed characterization of three solid-phase analogues as structurally and compositionally well-defined reference materials. We successfully synthesized a cesium salt of the aluminate monomer, CsAl(OH) 4 ·2H 2 O, for comparison to potassium and rubidium salts of the aluminate dimer, K 2 Al 2 O(OH) 6 , and Rb 2 Al 2 O(OH) 6 , respectively. Single crystal and powder X-ray diffraction methods clearly reveal the structure and purity of these materials for which a combination of 27 Al MAS-NMR, Al K-edge X-ray absorption and Raman/IR spectroscopies was then used to fingerprint the two major tetrahedrally coordinated Al species. The resulting insights into the effect of Al–O–Al bridge formation between aluminate tetrahedra on spectroscopic features may also be generalized to the many materials that are based on this motif.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment among environmental programs in higher education: What Food-Energy-Water Nexus concepts are covered in introductory courses?

Interdisciplinary environmental and sustainability (IES) programs are different from other fields because they focus on a complex integration of humanities, social, and natural sciences concepts centered on the interactions of coupled human and natural systems. The interdisciplinary nature of IES programs does not lend itself to traditional discipline-specific concept inventory frameworks for critically evaluating preconceptions and learning. We discuss the results of the first phase of a research project to develop a next generation concept inventory for evaluating interdisciplinary concepts important for introductory IES courses. Using the Food-Energy-Water (FEW) Nexus (the intersections/interdependencies of food, energy, and water sectors) as our focus, we conducted a content analysis of eight representative college-level introductory environmental course syllabi and course materials (e.g., textbooks, journal articles, print media) to identify common interdisciplinary FEW Nexus concepts taught in introductory IES courses. Results demonstrate that all IES introductory course materials reference the FEW Nexus. Food, energy, and/or water resources as individual elements of the FEW Nexus are frequently described, but connections between these resource systems are included less often. Biology, energy systems, waste and pollution in the natural environment, agriculture, earth sciences and geology, climate change, behavioral social sciences, and economics concepts are most associated with FEW concepts, hinting at commonalities across IES topics that anchor systems thinking. Despite differences in IES programs, there appears to be some alignment between core concepts being taught at the FEW Nexus in introductory courses.

54 ENVIRONMENTAL SCIENCES↗

Determination of fluorine distribution in shark teeth by laser-induced breakdown spectroscopy

Quantifying the chemical composition of fast-growing hard tissues in the environment can shed valuable information in terms of understanding ecosystems both prehistoric and current. Changes in chemical composition can be correlated with environmental conditions and can provide information about the organism's life. Sharks can lose 0.1 to 1.1 teeth/day, depending on species, which offers a unique opportunity to record environmental changes over a short duration of time. Shark teeth contain a biomineral phase that is made up of fluorapatite [Ca 5 (PO 4 ) 3 F], and the F distribution within the tooth can be correlated to tooth hardness. Typically, this is determined by bulk acid digestion, energy-dispersive X-ray spectroscopy (EDS), or wavelength-dispersive spectroscopy. Here we present laser-induced breakdown spectroscopy (LIBS) as an alternative and faster approach for determining F distribution within shark teeth. Using a two-volume laser ablation chamber (TwoVol3) with innovative embedded collection optics for LIBS, shark teeth were investigated from sand tiger (Carcharias Taurus), tiger (Galeocerdo Cuvier), and hammerhead sharks (Sphyrnidae). Fluorine distribution was mapped using the CaF 603 nm band (CaF, Β 2 Σ + → X 2 Σ + ) and quantified using apatite reference materials. In addition, F measurements were cross referenced with EDS analyses to validate the findings. Distributions of F (603 nm), Na (589 nm), and H (656 nm) within the tooth correlate well with the expected biomineral composition and expected tooth hardness. This rapid methodology could transform the current means of determining F distribution, particularly when large sample specimens (350 mm 2 , presented here) and large quantities of specimens are of interest.

36 MATERIALS SCIENCE↗

Shock-compressed silicon: Hugoniot and sound speed up to 2100 GPa

In this work, the high-pressure equation of state and isentropic sound speed of fluid silicon were studied using laser-driven shock waves. Principal Hugoniot measurements to 2100 GPa were performed using impedance matching to an α-quartz reference. Sound speed was determined by time correlating imposed shock-velocity perturbations in both the sample (Si) and reference material (α-quartz). A change in shock velocity versus particle velocity (u s –u p ) slope on the fluid silicon principal Hugoniot was detected at 200 GPa. Density functional theory-based quantum molecular dynamics simulations suggest that an increase in ionic coordination and 50% increase in average ionization is coincident with the experimentally observed change in slope.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗