Development of a Power Electronics-based Testbed for a Flexible Combined Heat and Power System

A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

COMSOL Models and Simulation Results for Closed-Loop Geothermal Systems with Thermal Enhancements

The Closed-Loop Geothermal Working Group and the National Renewable Energy Laboratory (NREL) have studied the performance of disc-shaped and linear thermal enhancements (conductive material introduced around a wellbore) in closed-loop geothermal systems. COMSOL models were developed to investigate the increase in heat production in systems with thermal enhancements compared to those without, across a range of scenarios. This dataset includes two example COMSOL models, a summary of the simulation results, and a link to an accompanying paper. Studied are idealized versions of two thermal enhancement designs: (1) existing or newly created fractures surrounding the wellbore, filled with highly conductive material, and (2) a 'fishbone structure,' where short wellbores are drilled radially outward from the main wellbore and filled with highly conductive material.

15 GEOTHERMAL ENERGY↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oilwell Conversion (Well API 121913310501) to Geothermal Heat Storage Well for Flexible Electricity Storage

Geothermal growth is limited by a lack of geographically dispersed high-temperature thermal resources and high initial upfront investment in characterization and well construction. This project intended to address the challenges of energy supply intermittency and enhance grid resilience, reliability, and energy security by storing energy provided from currently available renewable resources in the subsurface to harvest it a later time during at-peak energy demand. This project intended to improve geothermal adoption, reduce initial project risk, and improve price competitiveness through utilizing existing oil and gas infrastructure such as non-productive wells, non-economic fields, dry holes, and orphaned wells. The project also intended to address the lack of geographically dispersed thermal resources and enhance grid resilience, reliability, and energy security by introducing an economical method for storing energy from currently available renewable resources in the subsurface for usage during at-peak energy demand. During this research, the project furthered the understanding of the feasibility of utilizing abandoned oil and gas wells as geothermal heat storage wells. The project team investigated the heat storage and hydrogeological characteristics of subsurface reservoirs in the Illinois Basin to evaluate their response to heat injection for determining the evolution of temperature profiles and heat losses over time using existing and available data sets. The project team then performed modeling and simulation to evaluate the heat losses of returning fluids during heat extraction. The outputs were used to select an optimal candidate reservoir and location in Southern Illinois. The team designed and performed a small-scale field test in an existing oil well to refine the model and to demonstrate the permitting and regulatory pathways necessary for the conversion of oil and gas assets to geothermal use. The field test also serves as a proof of concept and can guide the procedures for future research and implementation. Additionally, the project team, conducted initial market research and customer discovery to develop a go to market strategy for an Advanced Geothermal Energy Storage (AGES) system. The project team in this research also identified the parameters to be refined in future research, to improve the current go to market strategy economic model. To this end several subject matter experts were also identified to assist in future research with geothermal infrastructure setup, energy storage policy and law, energy storage market demand, potential siting based on demand etc. Future research will involve further sophistication of the site commercial modeling, implementing a larger-scale test, and further refinement of the thermodynamic modeling/simulation process. The output will be lifecycle costs and economics suitable for comparison to alternative approaches from a validated full-scale demonstration for venture capital investment into this technology. The project successfully demonstrated the ability to leverage existing oilfield infrastructure, permits, and land access and leasing agreements, to enable geothermal storage projects to come online faster and cheaper than a greenfield development could. This technology could allow for greater energy independence and security through long-term energy storage solutions. The longer duration allows for greater storage for renewables currently limited by hours-long storage durations of lithium-ion. The AGES system would support the growth of renewable energy farms, and provide greater opportunities for a cleaner energy infrastructure.

15 GEOTHERMAL ENERGY↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Bishop Paiute Single Family Solar Home Project: Phase 4 (Final Technical Report)

The Bishop Paiute Tribe is committed to energy efficiency, renewable energy, and environmental protection and has a vision to install solar energy systems on all buildings on the Reservation where technically feasible. Through completion of the Bishop Paiute Tribe Residential Solar Program – Phase 4, Bishop Paiute Tribe continued its successful model partnering with non-profit solar installer GRID Alternatives to advance its vision and build energy self-sufficiency on the Bishop Paiute Reservation. The Bishop Paiute Tribe Residential Solar Program – Phase IV deployed 67 kW-AC of new clean, renewable energy through grid-tied, net-metered rooftop solar electric systems installed on a total of 20 (one more than the planned 19) existing owner-occupied, single-family homes for low-income families on the Reservation. This represents nearly 14% of the Reservation’s total “unsolarized” homes. These systems were provided at no cost to the homeowners, who will also receive energy efficiency education to further reduce energy consumption and lower electric bills. GRID led a solar installation for three (3) of the homes where Tribal/community members, were given an opportunity in participating in on-the-roof trainings to gain new skills while installing solar for their low-income community members. Subcontractors through GRID Sub Contractor Partnership Program (GRID SPP) led solar installations for seventeen (17) of the homes. Each installation provided paid employment for a solar trainee trainees hired by the SPP subcontractors as entry level solar installers. It is estimated that the installed 67 kW-AC of solar will produce at least 120,000 kWh/year, displacing at least 30-75% of the 20 homes’ total electricity use for a combined system lifetime electricity cost savings for the low-income homeowners of about $\$$500,000. It is further estimated that the installed renewable energy systems installed will prevent greenhouse gases by about 1,000 tons, equivalent to planting approximately 25,000 trees. Following the successful completed installations, it is expected that the Reservation and surrounding communities will benefit from improved air quality via reduced wood stove use for heating. Cumulatively with other initiatives, the project will result in nearly 40% of the Reservation’s solarizable homes being solarized. Overall, the triple impact of the phase 4 of the Bishop Paiute Tribe Residential Solar Program – Phase 4 is: 1) affordable energy for low-income families; 2) on-site clean energy production, 3) hands on training and paid solar installation work for local tribal/community workers. These impacts will support and grow the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the neediest on the Reservation.

14 SOLAR ENERGY↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Airfoil Cooling Schemes to Increase Efficiency in Gas Turbines for Combined Heat and Power Applications

This report describes a three-year interdisciplinary effort funded by the U.S. Department of Energy’s (DOE) Energy Efficiency and Renewable Energy/Advanced Manufacturing Office (EERE/AMO) to promote market penetration of combined heat and power (CHP) technologies. Prior studies have shown the technical potential for CHP in the United States is much larger than the current deployment of CHP systems. A large portion of the technical potential CHP market aligns with small (<20 MWe) gas turbines. CHP systems are an attractive alternative to reduce greenhouse gas (GHG) emissions. For example, CHP systems can reduce GHG emissions by 30–40% relative to a conventional boiler and power configuration. These GHG emission reductions are “avoided emissions” which means no CO 2 separation or sequestration is required. This report describes an effort to use additive manufacturing (AM) technologies and advanced airfoil cooling designs to increase the turbine inlet temperature by 100 °C for small gas turbines typically used in CHP systems. At the beginning of this effort, baseline performance data for small gas turbines was not available, and the potential benefits of cooling system improvements were not quantified in the available literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

Challenges resulting from urban density and climate change for the EU energy transition

Dense urban morphologies further amplify extreme climate events due to the urban heat island phenomenon, rendering cities more vulnerable to extreme climate events. Here we develop a modelling framework using multi-scale climate and energy system models to assess the compound impact of future climate variations and urban densification on renewable energy integration for 18 European cities. We observe a marked change in wind speed and temperature due to the aforementioned compound impact, resulting in a notable increase in both peak and annual energy demand. Therefore, an additional cost of 20–60% will be needed during the energy transition (without technology innovation in building) to guarantee climate resilience. Failure to consider extreme climate events will lower power supply reliability by up to 30%. Here, energy infrastructure in dense urban areas of southern Europe is more vulnerable to the compound impact, necessitating flexibility improvements at the design phase when improving renewable penetration levels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Collaboration to Enable Higher Penetrations of Solar Power Generation Using the Natural Gas Pipeline System for Energy Storage (CRADA CRD-14-00567)

This unique project explored one possible solution for photovoltaic (PV) generation to become a reliable and dispatchable energy resource similar to conventional baseload fossil fuel electricity generation. Solar power generation is a renewable resource that varies naturally from day-to-day as well as seasonally. To use solar power as a baseload generation asset requires a flexible storage system that can recover power on both a daily and seasonal basis. Converting solar power to natural gas (i.e., first to hydrogen and then to methane) and having access to utility-scale storage in the natural gas network has the potential to make solar power generation a baseload asset. This will: 1) Increase the net energy yield from solar resources by increasing the effective capacity factor and maximize the energy produced during the assets’ lifetimes. 2) Improve the economics of energy storage for solar project developers, thereby accelerating the deployment of new solar generation. 3) Reduce the impact of increasing solar penetration on congestion of the electrical transmission system by shifting power delivery in time using the gas pipeline network for long-duration storage. 4) Reduce the impact of increasing solar generation on electrical distribution system control. 5) Offer alternative revenue sources for solar power generation beyond electricity including: hydrogen (H 2 ) production for stationary fuel cells and fuel cell electric vehicles, conversion of carbon dioxide (CO 2 ) to methane (CH 4 ) as a direct drop-in replacement for fossil natural gas use, and transmission as high volumetrically-dense CH 4 for use in transportation, heating, power generation, chemical production or conversion back to H2 at the point of use. Additional work was added to this CRADA in modification 4 having a primary objective to characterize the performance of the electrolyzer, Southern California Gas (SoCalGas) bioreactor and balance of plant to demonstrate production of renewable natural gas (RNG) from renewable H 2 and CO 2 using single-cell, self-replicating organisms. The additional scope of work allowed researchers to ramp up gas flowrates and pressure of the system over the designed range to grow the cells and begin to show the load-following capabilities of this anaerobic gas fermentation process. These activities enabled the research team to predict system performance at much greater scales; namely 10’s of mega-watts (MWs) of electrolyzer nameplate capacity.

14 SOLAR ENERGY↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.